• Title/Summary/Keyword: Aerosol measurement

Search Result 239, Processing Time 0.023 seconds

An Experiment for Surface Reflectance Image Generation of KOMPSAT 3A Image Data by Open Source Implementation (오픈소스 기반 다목적실용위성 3A호 영상자료의 지표면 반사도 영상 제작 실험)

  • Lee, Kiwon;Kim, Kwangseob
    • Korean Journal of Remote Sensing
    • /
    • v.35 no.6_4
    • /
    • pp.1327-1339
    • /
    • 2019
  • Surface reflectance obtained by absolute atmospheric correction from satellite images is useful for scientific land applications and analysis ready data (ARD). For Landsat and Sentinel-2 images, many types of radiometric processing methods have been developed, and these images are supported by most commercial and open-source software. However, in the case of KOMPSAT 3/3A images, there are currently no tools or open source resources for obtaining the reflectance at the top-of-atmosphere (TOA) and top-of-canopy (TOC). In this study, the atmospheric correction module of KOMPSAT 3/3A images is newly implemented to the optical calibration algorithm supported in the Orfeo ToolBox (OTB), a remote sensing open-source tool. This module contains the sensor model and spectral response data of KOMPSAT 3A. Aerosol measurement properties, such as AERONET data, can be used to generate TOC reflectance image. Using this module, an experiment was conducted, and the reflection products for TOA and TOC with and without AERONET data were obtained. This approach can be used for building the ARD database for surface reflection by absolute atmospheric correction derived from KOMPSAT 3/3A satellite images.

Measurement of Dust Concentration in a Mechanically Ventilated Broiler House and Analysis of Dust Generation from Ground Beds (강제환기식 계사의 공기 중 분진 농도 측정 및 바닥재로부터의 분진 발생량 분석)

  • Kwon, Kyeong Seok;Jo, Ye Seul;Lee, In Bok;Ha, Tae Hwan;Hong, Se Woon
    • Journal of The Korean Society of Agricultural Engineers
    • /
    • v.56 no.6
    • /
    • pp.31-43
    • /
    • 2014
  • Confined and mechanically ventilated broiler house has been recently come into wide use to increase productivity and control rearing conditions. However, high dust concentration inside facility can threaten respiratory welfare of farmers and broilers. In Korea, there is no regulation in terms of air quality control inside agricultural facilities and sufficient data is not available. To cope with these, periodic monitoring of inhalable and respirable dust concentration were conducted according to season, broiler's activity and specific events such as shipment work for broilers in mechanically ventilated broiler house. Chamber experiment was also designed to analyze mechanism of dust generation from ground beds according to water contents and surrounding wind environment. Results showed that significant increase of inhalable (p=0.002) and respirable (p=0.03) dust were observed when activity of broilers was high according to entrance of the workers. Even shipment work for matured broilers, high level of dust were observed; inhalable dust was exceeded the threshold limit over maximum 303 % and respirable dust was over maximum 1,550 %, implying that acute respiratory symptoms could be manifested for the workers. From the chamber experiment, critical water contents for interrupting of dust generation were measured; about 45 % for inhalable dust and about 50 % for respirable dust. These results can be a trigger for designing plan of dust control however it still needs consideration of various environmental conditions, hygiene problems, etc.

Development of an Automated and Continuous Analysis System for PM2.5 and Chemical Characterization of the PM2.5 in the Atmosphere at Seoul (자동연속측정시스템 개발 및 이 시스템을 이용한 서울 대기 중 PM2.5의 화학적 조성과 특성에 관한 연구)

  • Lee Bo Kyoung;Kim Young Hoon;Ha Jae Yoon;Lee Dong Soo
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.21 no.4
    • /
    • pp.439-458
    • /
    • 2005
  • An automated analysis system for water soluble constituents in $PM_{2.5}$ has been developed. The system consists of a high capacity multi tube diffusion scrubber (MTDS), a low temperature particle impactor (LTPI), and two ion (anion and cation) chromatography (IC) systems. Atmospheric particles have been collected by passing sample air through a thermostated MTDS followed by a LTPI. This system allows simultaneous measurements of soluble ions in $PM_{2.5}$ at 30 minutes interval. At the air sampling flow rate of 1.0L/min, the detection limits of the overall system are in the order of tens of $ng/m^3$. This system has been successfully used for the measurement of particulate components of Seoul air from April 2003 to January 2004. $SO_4^{2-},\;NO_3^-,\;NH_4^+,\;NO_2^-,\;Cl^-,\;Na^+,\;K^+,\;Ca^{2+},\;and\;Mg^{2+}$ are the major ionic species for $PM_{2.5}$ at Seoul. Among them, $SO_4^{2-},\;NO_3^-\;and\;NH_4^+$ are the most abundant ions, contributed up to $86\%$ of the total and the concentrations were higher than those in any other urban sites in the world except for Chinese cities. There are high pollutant episodes which contribute about $15\~20\%$ of annual average values of the major ions. During the episode, the all parcels were transported from the asian continent and $PM_{2.5}$ were significantly neutralized. This suggests that aged and long range transported pollutants caused the high pollutant episodes. They showed a distinct daily and seasonal variations:they showed a peak in the early morning caused by the night-time accumulation of particulate matters. Atmospheric reactions including gas-to-particle reactions and inter-particle reactions and meteorological parameters including relative humidity and ambient temperature were described with related to the $PM_{2.5}$ 5 concentrations. All of the ionic species showed higher concentrations during the spring than those for summer and winter.

An Analysis of Global Solar Radiation using the GWNU Solar Radiation Model and Automated Total Cloud Cover Instrument in Gangneung Region (강릉 지역에서 자동 전운량 장비와 GWNU 태양 복사 모델을 이용한 지표면 일사량 분석)

  • Park, Hye-In;Zo, Il-Sung;Kim, Bu-Yo;Jee, Joon-Bum;Lee, Kyu-Tae
    • Journal of the Korean earth science society
    • /
    • v.38 no.2
    • /
    • pp.129-140
    • /
    • 2017
  • Global solar radiation was calculated in this research using ground-base measurement data, meteorological satellite data, and GWNU (Gangneung-Wonju National University) solar radiation model. We also analyzed the accuracy of the GWNU model by comparing the observed solar radiation according to the total cloud cover. Our research was based on the global solar radiation of the GWNU radiation site in 2012, observation data such as temperature and pressure, humidity, aerosol, total ozone amount data from the Ozone Monitoring Instrument (OMI) sensor, and Skyview data used for evaluation of cloud mask and total cloud cover. On a clear day when the total cloud cover was 0 tenth, the calculated global solar radiations using the GWNU model had a high correlation coefficient of 0.98 compared with the observed solar radiation, but root mean square error (RMSE) was relatively high, i.e., $36.62Wm^{-2}$. The Skyview equipment was unable to determine the meteorological condition such as thin clouds, mist, and haze. On a cloudy day, regression equations were used for the radiation model to correct the effect of clouds. The correlation coefficient was 0.92, but the RMSE was high, i.e., $99.50Wm^{-2}$. For more accurate analysis, additional analysis of various elements including shielding of the direct radiation component and cloud optical thickness is required. The results of this study can be useful in the area where the global solar radiation is not observed by calculating the global solar radiation per minute or time.

Effects of Additives on the Characteristics of Sodium Borosilicate Thin Film Fabricated by AFD Method (첨가제가 AFD법에 의해 제조된 광소자용 Sodium Borosilicate 박막의 물성에 미치는 영향)

  • Chung, Hyung-Gon;Chun, Young-Yun;Mun, Jong-Ha;Chung, Suck-Jong;Lee, Hyung-Jong
    • Korean Journal of Materials Research
    • /
    • v.8 no.8
    • /
    • pp.693-698
    • /
    • 1998
  • The effects of $AI_{2}$$O_{3}$ and the ratio of $Na_2O/B_2O_3$ on the phase separation and optical properties of sodium borosilicate glass film fabricated by AFD(Aerosol Flame Deposition) were investigated. When AI,O, of 6wt% was added to $66SiO_2-27B_2O_3-7Na_2O$ the clear glass film without any crystallization was produced under air-quenching condition after consolidation. As the amount of $AI_{2}$$O_{3}$ increased from 1.5 to 6.0 wt% the refractive index linearly increased from 1.4610 to 1.4701, and the difference of TE and TM mode causing by residual stress in film increased gradually. However, the difference of TE and TM mode to reveal birefringence could be minimized by annealing below the glass transition temperature after consolidation and air quenching. On the other hand. as the ratio of $Na_2O/B_2O_3$ increased the refractive index and birefringence of glass film tended to increase, but the measurement of their values were not available at over the critical ratio of $Na_2O/B_2O_3$, because of the cloudiness due to crystallization. The phase separation was greatly accelerated with increasing the ratio of $Na_2O/B_2O_3$.

  • PDF

Chemical Composition of Fine Particulate Matter in the Downtown Area of Jeju City (제주시 도심지역 미세먼지의 화학적 조성 특성)

  • Hu, Chul-Goo;Lee, Ki-Ho
    • Journal of Environmental Science International
    • /
    • v.27 no.7
    • /
    • pp.597-610
    • /
    • 2018
  • This study observed particulate matter ($PM_{2.5}$ and $PM_{10}$) in the downtown area of Jeju City, South Korea, to understand the chemical composition of particulates based on an analysis of the water-soluble ionic species contained in the particles. The mass fraction of the ionic species in the sampled $PM_{10}$ and $PM_{2.5}$ was 44.3% and 42.2%, respectively. In contrast, in Daegu City and Suwon City, the mass fraction of the ionic species in $PM_{2.5}$ was higher than that in $PM_{10}$. The chloride depletion percentage of $PM_{10}$ and $PM_{2.5}$ in Jeju City was higher than 61% and 66%, respectively. The contribution of sea-salt to the mass of $PM_{10}$ (5.9%) and $PM_{2.5}$ (2.6%) in Jeju City was similar to that in several coastal regions of South Korea. The mass ratio of $Cl^-$ to $Na^+$ in the downtown area of Jeju City was comparable to that in some coastal regions, such as the Gosan Area of Jeju Island, Deokjeok Island, and Taean City. The mass fraction of sea-salt in $PM_{10}$ and $PM_{2.5}$ was very low, and the concentration of sodium and chloride ions in $PM_{10}$ was not correlated with those in $PM_{2.5}$ ($R^2$ < 0.2), suggesting that the effects of sea-salt on the formation of particulate matter in Jeju City might be insignificant. The relationship between $NH_4{^+}$ and several anions such as $SO_4{^{2-}}$, $NO_3{^-}$, and $Cl^-$, as well as the relationship between the measurement and calculation of ammonium ion concentration, suggested that sea-salts may not react with $H_2SO_4$, and $(NH_4)_2SO_4$ may be a major secondary inorganic aerosol component of $PM_{2.5}$ and $PM_{10}$ in Jeju City.

Effect of Short Term Treatment with Different Dosage of Inhaled Flucatisone Propionate on Basal Cortisol Concentration (단기간 Fluticasone Propionate 투여 용량에 따른 가저 코르티솔 농도의 변화)

  • Kim, Hyun-Jung;Kim, Hyoung-Sik;Lee, Hong;Moon, Sung-Gi;Lim, Seok-Tae;Park, Ji-Hyun;Lee, Heung-Bum;Lee, Yong-Chul;Rhee, Yang-Keun
    • Tuberculosis and Respiratory Diseases
    • /
    • v.44 no.5
    • /
    • pp.1063-1071
    • /
    • 1997
  • Backgroung : The efficacy of oral corticosteroids in the treatment of chronic asthma is undisputed, but their long-term use is associated with adverse side-effects, including supression of the hypothalamic-pituitary adrenal axis function, osteoporosis, weight gain, hypertension and impaired glucose tolerance. The introduction of inhaled corticosteroids in the early 1970's represented a significant therapeutic advance in the management of asthma, since these compounds combined high topical potency with low systemic activity. Fluticasone propionate is a new topically active synthetic glucocorticosteroid that combinds a high degree of efficacy with negligible systemic bioavailability. This study was perfomed to determine the effect of inhaled fluticasone propionate on the adreocortical supression in patients with bronchial asthma or chronic obstructive pulmonary disease. Method : The adrenocortical function was assessed by measurement of plasma cortisol concentration at 8 o'clock in morning and free cortisol in 24 hour urine collection at interval. Absolutely, no steroid was taken during pretreatment period of 10days. There after each subject inhaled fluticasone aerosol, in daily doses of 500 or 1000micrograms for 12days. The dose was delivered by metered dose inhaler(MDI). Results : The serum cortisol and 24hour urinary free cortisol were not decreased during the treatment period in patients with inhaled fluticasone propionate in daily doses of 500 micrograms. In contrast, serum cortisol was significantly decreased on 9th and 12th day(p less than 0.05). And, 24hour urinary free cortisol was also significantly decreased on 3rd and 12th day of treatement period(p less than 0.05) in patients with inhaled fluticasone in daily doses of 1000 micrograms. Conclusion : These results suggested that endogenous cortisol secretion was not supressed after short-term inhalation of fluticasone in daily dose of 500 micrograms, but in daily dose of 1000 micrograms, the endogenous cortisol secretion was supressed.

  • PDF

The Measurement of $^{99m}Tc-DTPA$ Pulmonary Clearance in Normals, Asymptomatic Smokers and Diabetic Patients (정상 성인, 무증상 흡연자, 당뇨병 환자에서 $^{99m}Tc-DTPA$ 폐제거율의 측정)

  • Kim, In-Ju;Kim, Seong-Jang;Kim, Yong-Ki;Kim, Yun-Seong;Lee, Min-Ki;Park, Soon-Kew
    • The Korean Journal of Nuclear Medicine
    • /
    • v.32 no.3
    • /
    • pp.266-275
    • /
    • 1998
  • Purpose: We measured pulmonary epithelial permeability by $^{99m}Tc-DTPA$ radioaerosol clearance in patients with diabetes and correlated with the presence of microangiopathy to understand the pathophysiology of pulmonary microangiopathy and evaluate $^{99m}Tc-DTPA$ radioaerosol clearance as a diagnostic test to assess pulmonary microangiopathy. Materials and Methods: We performed $^{99m}Tc-DTPA$ radioaerosol scan in 10 normal subjects, 10 asymptomatic smokers, 20 diabetic patients without history of smoking (10 with microangiopathy, 10 without microangiopathy). $^{99m}Tc-DTPA$ clearance half-time ($T_{1/2}$) was calculated, then compared with the result of chest radiography and pulmonary function test. Results: Chest radiography and pulmonary function test were normal in all subjects. There were no significant difference of clinical or laboratory characteristics between these groups except age. The diabetic patients with microangiopathy were significantly older (p<0.05). The $T_{1/2}$ of normal subjects and asymptomatic smokers were significantly different ($65.2{\pm}23.7min$ vs $39.6{\pm}9.8min$, p<0.05). For diabetic patients with microangiopathy, the $T_{1/2}$ was $90.5{\pm}46.5min$ and significantly delayed when compared with those of normals and asymptomatic smokers (p<0.05). However, the $T_{1/2}$ of diabetic patients without microangiopathy, $70.0{\pm}12.7min$, was not significantly different from those of normals or asymptomatic smokers (p>0.05). No significant correlation was found between the $T_{1/2}$ and spirometric parameters including DLco, FVC, $FEV_1,\;FEV_1/FVC$ (%) and $FEF_{25-75%}$ in all subjects, and between the $T_{1/2}$ and duration of diabetes ;in diabetic patients. Conclusion: Eventhough the influence of age can't be excluded, delayed $^{99m}Tc-DTPA$ clearance half-time ($T_{1/2}$) in diabetic patients with microangiopathy indicates decreased pulmonary capillary permeability as one of the pathophysiologic results of pulmonary microangiopaththy. Further studies are needed in larger number of age matched control and diabetic patients to evaluate the diagnostic efficacy.

  • PDF

A Study on the Characteristics of PM1.0 Chemical Components Using a Real-time Aerosol Mass Spectrometer (실시간 에어로졸 질량분석기를 이용한 PM1.0의 화학적성분의 특성에 관한 연구)

  • Park, Jinsoo;Choi, Jinsoo;Kim, Hyunjae;Oh, Jun;Sung, Minyoung;Ahn, Joonyoung;Lee, Sangbo;Kim, Jeongho
    • Journal of the Korean Society of Urban Environment
    • /
    • v.18 no.4
    • /
    • pp.485-494
    • /
    • 2018
  • This study aims to identify the characteristics of oxidation and chemical composition of PM in winter season, 2017 at Incheon area. The mean concentration of air pollutants were $46{\pm}22{\mu}g/m^3-PM_{10}$, $29{\pm}18{\mu}g/m^3/-PM_{2.5}$, $5{\pm}3ppb-SO_2$, $0.56{\pm}0.24ppm-CO$, $21{\pm}13ppb-O_3$ and $28{\pm}17ppb-NO_2$, respectively. The dominant ion of the $PM_{1.0}$ chemical component were organic with $3.2{\mu}g/m^3$ and nitrate with $1.9{\mu}g/m^3$. The day and night variation of the $PM_{1.0}$ chemical components was higher in nighttime than those of daytime. The averaged nitrate oxidation rate (SOR) was 0.06 and sulfate oxidation rate was 0.11 during the field campaign. In the high mass loading period, nitrate oxidation rate (NOR) was up to 0.6 and also the nitrate in $PM_{1.0}$ was increased. The averaged ratio of $NO_x/SO_2$ was 8.7 and nitrate/sulfate was 3.1, respectively. In this results, the nitrate component in $PM_{1.0}$ was influenced by NOx from the stationary source as power plant and the mobile source around the measurement site.