• Title/Summary/Keyword: Aerosol measurement

Search Result 239, Processing Time 0.021 seconds

Review on the Recent PM2.5 Studies in China (최근 중국의 초미세먼지 오염 연구 동향)

  • Kim, Yumi;Kim, Jin Young;Lee, Seung-Bok;Moon, Kil-Choo;Bae, Gwi-Nam
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.31 no.5
    • /
    • pp.411-429
    • /
    • 2015
  • The Korea Ministry of Environment has established an air quality standard for $PM_{2.5}$ in 2012 and it is effective from January 2015. In this study, we review various aspects of $PM_{2.5}$ in China, including its measurement, modeling, source apportionment, and health effect, and suggest future research directions for $PM_{2.5}$ studies in Korea. Measurements studies for $PM_{2.5}$ have examined organic marker compounds and $^{14}C$ as well as inorganic aerosols for distinguishing sources. Modeling results supported that the control of $PM_{2.5}$ pollution in big city needs effective cooperation between city and its surrounding regions. The major $PM_{2.5}$ sources in China have been identified to be secondary sulfur, motor vehicle emissions, coal combustion, dust, biomass burning, and industrial sources, however, they have seasonal dependency. Especially, the severe haze pollution event during January 2013 over eastern and northern China was driven to a large extent by secondary aerosol formation. Short-term exposure to $PM_{2.5}$ is strongly associated with the increased risk of morbidity and mortality from cardiovascular and respiratory diseases, as well as total non-accidental mortality. Considered previous $PM_{2.5}$ studies in China, analysis of specific organic species using online measurement, chamber experiment for secondary aerosol formation mechanism, and development of parameterizing this process in the model are needed to elucidate factors governing the abundance and composition of $PM_{2.5}$ in Korea.

Numerical and experimental study on the pressure dorp of axial-flow cyclone in the air handling unit (공기조화기 장착용 축상유입식 싸이클론의 압력손실에 대한 수치해석 및 실험적 연구)

  • Kwon, Soon-Bark;Park, Duck-Shin;Cho, Youngmin;Kim, Se-Young;Kim, Myeoung-Joon;Kim, Hojoong;Kim, Taesung
    • Particle and aerosol research
    • /
    • v.5 no.2
    • /
    • pp.37-43
    • /
    • 2009
  • Particulate matter (PM) is one of the major indoor air pollutants especially in the subway station in Korea. In order to remove PM in the subway station, several kinds of PM removal system such as roll-filter, auto-washable air filter, demister, and electrostatic precipitator are used in the air handling unit (AHU) of subway stations. However, those systems are prone to operation and maintenance problems since the filter-regeneration unit consisting of electrical or water jet parts might malfunction due to the high load of particulates unless the filter medium is periodically replaced. In this study, the use of axial-flow cyclone was proposed for particulate filter unit in the AHU for its low operation and maintenance cost. Novel shape of axial-flow cyclone was designed by using computational fluid dynamics (CFD). The shape of vortex vane was optimized in terms of pressure drop and tangential velocity. In addition, CFD analysis was validated experimentally through the pressure drop measurement of mock-up model. We found that pressure drop and tangential velocity of fluid through the axia-flow cyclone was significantly affected by the rotating degree of vortex vane and the numerical prediction of pressure drop agreed well with experimental measurement.

  • PDF

Comparison of Ground-Based Particulate Matter Observations in the Seodaemun-gu District, Seoul (서울 서대문구 지상 미세먼지 관측 비교)

  • Koo, Ja-Ho;Lee, Seoyoung;Kim, Minseok;Park, Joonghee;Jeon, Soo Ahn;Noh, Hyunsuk;Kim, Jhoon;Lee, Yun Gon
    • Atmosphere
    • /
    • v.28 no.4
    • /
    • pp.469-477
    • /
    • 2018
  • We performed the comparison of observed $PM_{10}$ and $PM_{2.5}$ at both the Yonsei University and the AIRKOREA site in the same Seodaemun-gu district, Seoul from March to December 2016. Generally, the moderate correlations between two sites were found for both $PM_{10}$ and $PM_{2.5}$, but monthly difference was somewhat occurred, implying that the measurement situation is not equally maintained even in a closely located area. Particularly correlations became weaker in June and July, which seems the impact of rainy conditions. Correlations between two stations were higher for $PM_{10}$ compared to $PM_{2.5}$, probably indicating the spatially larger difference of fine mode particle. Monthly mean variation was similar between two sites showing a maximum in March and minimum in August. Diurnal variation was somewhat different: morning peak at Yonsei University but evening peak at the Seodaemun-gu AIRKOREA site, reflecting the difference of local air condition. We also compared the extent of $PM_{10}$ and $PM_{2.5}$ according to the local wind speed and direction. In general, the level of particulate matter was high when the wind is blowing from the northwestern area with low wind speed, meaning the high accumulation effect of transported air particles. Findings of this study can be usefully considered for the investigation about the discrepancy of aerosol measurement in a local scale.

Measurement of Cloud Velocity and Altitude Using Lidar's Range Detection and Digital Image Correlation

  • Park, Nak-Gyu;Baik, Sung-Hoon;Park, Seung-Kyu;Kim, Dong-Lyul;Kim, Duk-Hyeon;Choi, In-Young
    • Journal of the Optical Society of Korea
    • /
    • v.18 no.5
    • /
    • pp.605-610
    • /
    • 2014
  • Clouds play an important role in climate change, in the prediction of local weather, and also in aviation safety when instrument assisted flying is unavailable. Presently, various ground-based instruments used for the measurements of the cloud base height or velocity. Lidar techniques are powerful and have many applications in climate studies, including the clouds' temperature measurement, the aerosol particle properties, etc. Otherwise, it is very circumscribed in cloud velocity measurements because there is no Doppler effect if the clouds move in the perpendicular direction to the laser beam path of Doppler lidar. In this paper, we present a method for the measurement of cloud velocity using lidar's range detection and DIC (Digital Image Correlation) system to overcome the disadvantage of Doppler lidar. The lidar system acquires the distance to the cloud, and the cloud images are tracked using the developed fast correlation algorithm of DIC. We acquired the velocities of clouds using the calculated distance and DIC algorithm. The measurement values had a linear distribution.

Ozone Monitoring in the Lower Tropospheric Atmosphere by LIDAR System (라이다 시스템을 이용한 하층 대류권 오존농도 측정)

  • 최성철;차형기;김덕현;김영상
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.17 no.5
    • /
    • pp.385-393
    • /
    • 2001
  • We have developed a Differential Absortion LIDAR (DIAL) method for the measurement of lower tropospheric ozone concentration. We used two laser beams from quadrupled Nd:YAG (266 nm) for the resonance wavelength and dye lasers (299.5 nm) for non -resonance wavelength. Aerosol extinction coefficients in the lower troposphere was computed by both Klett and Slope methods. To correct the SIN (Signal -Induced Noise) effect caused by photo detector, we subtracted a new-fitted baseline on the background part of a LIDAR signal, after the subtraction of the DC level. This is because SIN can be treated as an exponentially decaying tail. Using theme results, ozone profiles were obtained approximately 2km at daytime and 3km at nighttime. We compared the results derided by the Slope method with those measured by UV spectrometer. The computed results are in mostly good agreement with experimental results. In the measurement of the vertical layer, we observed the variation of the ozone profiles around the top mixed layer.

  • PDF

Spatial Distribution of Air Pollution Level inside Roadway Tunnels in Urban Area (도시 자동차도로 터널 내부의 대기오염도 공간분포 특징)

  • Park, Bo-Eun;Lee, Seung-Bok;Lee, Dong-Hun;Lee, Seung Jae;Woo, Dae-Kwang;Choi, Jae-Hyun;Jin, Hyoun-Cher;Bae, Gwi-Nam;Yun, Seong-Taek
    • Particle and aerosol research
    • /
    • v.8 no.1
    • /
    • pp.17-28
    • /
    • 2012
  • Air pollution levels of gases and aerosol particles inside the Jeongneung and Hongjimun tunnels of the Naebu express way in Seoul were investigated through on-road measurement using a mobile emission laboratory (MEL) on February 8, 2011. The concentrations of $NO_x$, $CO_2$, number concentration of particles ranging 21-560 nm, and surface area of particles deposited on a human lung almost linearly increased with increasing distance from the tunnel entrance, and decreased rapidly before the tunnel exit. This trend was observed regardless of tunnel length and driving directions, which thought to be caused by semi-transverse ventilation facilities of the tunnels. The concentration increments per 1-m distance for $NO_x$, $CO_2$, deposited particle surface area, and number of particles ranging 21-560 nm were 0.61~0.80 ppb, 0.16~0.21 ppm, $0.20{\sim}0.29{\mu}m^2/cm^3$, and 117~192 particles/$cm^3$, respectively. Average pollution levels inside the two tunnels for $CO_2$, deposited particle surface area, and number of particles >5.6 nm ranged 681~748 ppm, $246{\sim}381{\mu}m^2/cm^3$, and $2.4{\sim}6.7{\times}10^5$ particles/$cm^3$, respectively. In case of $NO_x$, the maximum concentration exceeded 1 ppm. These pollution levels inside the tunnels are much higher than those at urban background sites. This result can be utilized as basic data to evaluate the effectiveness of present ventilation system for reducing the pollution level caused by vehicles inside the tunnels.

Analysis on Electric Field Based on Three Dimensional Atmospheric Electric Field Apparatus

  • Xing, Hong-yan;He, Gui-xian;Ji, Xin-yuan
    • Journal of Electrical Engineering and Technology
    • /
    • v.13 no.4
    • /
    • pp.1697-1704
    • /
    • 2018
  • As a key component of lighting location system (LLS) for lightning warning, the atmospheric electric field measuring is required to have high accuracy. The Conventional methods of the existent electric field measurement meter can only detect the vertical component of the atmospheric electric field, which cannot acquire the realistic electric field in the thunderstorm. This paper proposed a three dimensional (3D) electric field system for atmospheric electric field measurement, which is capable of three orthogonal directions in X, Y, Z, measuring. By analyzing the relationship between the electric field and the relative permittivity of ground surface, the permittivity is calculated, and an efficiency 3D measurement model is derived. On this basis, a three-dimensional electric field sensor and a permittivity sensor are adopted to detect the spatial electric field. Moreover, the elevation and azimuth of the detected target are calculated, which reveal the location information of the target. Experimental results show that the proposed 3D electric field meter has satisfactory sensitivity to the three components of electric field. Additionally, several observation results in the fair and thunderstorm weather have been presented.

Investigation of SO2 Effect on TOMS O3 Retrieval from OMI Measurement in China (OMI 위성센서를 이용한 중국 지역에서 TOMS 오존 산출에 대한 이산화황의 영향 조사 연구)

  • Choi, Wonei;Hong, Hyunkee;Kim, Daewon;Ryu, Jae-Yong;Lee, Hanlim
    • Korean Journal of Remote Sensing
    • /
    • v.32 no.6
    • /
    • pp.629-637
    • /
    • 2016
  • In this present study, we identified the $SO_2$ effect on $O_3$ retrieval from the Ozone Monitoring Instrument (OMI) measurement over Chinese Industrial region from 2005 through 2007. The Planetary boundary layer (PBL) $SO_2$ data measured by OMI sensor is used in this present study. OMI-Total Ozone Mapping Spectrometer (TOMS) total $O_3$ is compared with OMI-Differential Optical Absorption Spectrometer (DOAS) total $O_3$ in various $SO_2$ condition in PBL. The difference between OMI-TOMS and OMI-DOAS total $O_3$ (T-D) shows dependency on $SO_2$ (R (Correlation coefficient) = 0.36). Since aerosol has been reported to cause uncertainty of both OMI-TOMS and OMI-DOAS total $O_3$ retrieval, the aerosol effect on relationship between PBL $SO_2$ and T-D is investigated with changing Aerosol Optical Depth (AOD). There is negligible aerosol effect on the relationship showing similar slope ($1.83{\leq}slope{\leq}2.36$) between PBL $SO_2$ and T-D in various AOD conditions. We also found that the rate of change in T-D per 1.0 DU change in PBL, middle troposphere (TRM), and upper troposphere and stratosphere (STL) are 1.6 DU, 3.9 DU and 4.9 DU, respectively. It shows that the altitude where $SO_2$ exist can affect the value of T-D, which could be due to reduced absolute radiance sensitivity in the boundary layer at 317.5 nm which is used to retrieve OMI-TOMS ozone in boundary layer.

Comparison of OC and EC Measurement Results Determined by Thermal-optical Analysis Protocols (열광학적 분석 프로토콜에 의한 유기탄소와 원소탄소 측정값 비교)

  • Kim, Hyosun;Jung, Jinsang;Lee, Jinhong;Lee, Sangil
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.31 no.5
    • /
    • pp.449-460
    • /
    • 2015
  • Carbonaceous aerosol is generally classified into OC (organic carbon) and EC (elemental carbon) by thermal optical analysis. Both NIOSH (National institute of occupational safety and health) with high temperature (HighT) and IMPROVE-A (Interagency monitoring of protected visual environments) with low temperature (LowT) protocols are widely used. In this study, both protocols were applied for ambient $PM_{2.5}$ samples (Daejeon, Korea) in order to underpin differences in OC and EC measurements. An excellent agreement between NIOSH and IMPROVE-A protocol was observed for TC (total carbon). However, significant differences between OC and EC appeared and the differences were larger for EC than OC. The main differences between two protocols are temperature profile and charring correction method. For the same charring correction method, HighT_OC was 10% higher than LowT_ OC, while HighT_EC was 15% and 33% lower than LowT_EC for TOT (thermal-optical transmittance) and TOR (thermal-optical reflectance), respectively. This difference may be caused by the temperature of OC4 in He step and possibly difference in POC (pryorilized OC) formation. For the same temperature profile, OC by TOT was about 26% higher than that by TOR. In contrast, EC by TOT was about 50% lower than that by TOR. POC was also dependent on both temperature profile and the charring correction method, showing much distinctive differences for the charring correction method (i.e., POC by TOT to POC by TOR ratio is about 2). This difference might be caused by different characteristics between transmittance and reflectance for monitoring POC formation within filters. Results from this study showed that OC and EC depends on applied analysis protocol as shown other studies. Because of the nature of the thermal optical analysis, it may not be possible to have an absolute standard analysis protocol that is applicable for any ambient $PM_{2.5}$. Nevertheless, in order to provide consistent measurement results for scientists and policy makers, future studies should focus on developing a harmonized standard analysis protocol that is suitable for a specific air domain and minimizes variations in OC and EC measurement results. In addition, future elaborate studies are required to find and understand the causes of the differences.

Measurement and analysis of PM10 and PM2.5 from chimneys of coal-fired power plants using a light scattering method (광산란법을 이용한 국내 석탄화력발전소 굴뚝에서 배출되는 PM10, PM2.5 측정 및 분석)

  • Shin, Dongho;Kim, Younghun;Hong, Kee-Jung;Lee, Gunhee;Park, Inyong;Kim, Hak-Joon;Kim, Yong-Jin;Han, Bangwoo;Hwang, Jungho
    • Particle and aerosol research
    • /
    • v.16 no.4
    • /
    • pp.131-140
    • /
    • 2020
  • Air pollutants emitted from chimneys of coal-fired power plants are considered to be a major source of fine particulate matter in the atmosphere. In order to manage fine particle in the chimney of a coal-fired power plant, it is necessary to know the concentration of fine particle emitted in real time, but the current system is difficult. In this study, a real-time measurement system for chimney fine particle was developed, and measurements were performed on six coal-fired power plants. Through the measurements, the mass concentration distribution according to the particle size could be secured. All six chimneys showed bimodal distribution, and the count median diameters of each mode were 0.5 and 1.1 ㎛. In addition, it was compared with the gravimetric measurement method, and it was determined that the relative accuracy for PM10 was within 20%, and the value measured using the developed measuring instrument was reliable. Finally, three power plants were continuously measured for one month, and as a result of comparing the concentration of PM10 according to the amount of power generation, it was confirmed that the PM10 discharged from the chimney increased in the form of an exponential function according to the amount of power generation.