• 제목/요약/키워드: Aerosol dynamics

검색결과 59건 처리시간 0.021초

사이클론 집진장치의 내부온도에 따른 외부 소용돌이와 집진효율의 관계 (Relationship between the Outer Vortex and the Collection Efficiency with respect to Temperatures in the Cyclone Dust Collector)

  • 현대근;장혁상
    • 한국입자에어로졸학회지
    • /
    • 제11권2호
    • /
    • pp.47-55
    • /
    • 2015
  • This study compares the results of collection efficiency of difference gas temperature in cyclone dust collector. The previous researcher's experiment results were used to confirm the reliability of CFD(Computational Fluid Dynamics) model. Based on this verified CFD model, we extended the analysis on the cyclone dust collectors. In CFD study, we used RNG k-epsilon model for analysis of turbulence flow, fluid is air, the velocity at inlet is 10 m/s, the temperature of air is $20^{\circ}C$, $100^{\circ}C$, $200^{\circ}C$, $300^{\circ}C$, $600^{\circ}C$ and $1000^{\circ}C$. As the temperature decreases, the average velocity of outer vortex and collection efficiency is increased, showed the highest collection efficiency at $20^{\circ}C$. It can be inferred smooth flow in cyclone dust collector is difficult because air viscosity increases as temperature increases. The power required at $1000^{\circ}C$ is almost 18 times greater than that of $20^{\circ}C$ to get the similar collection efficiency.

기상 공정에 의한 나노 미립자 제조 (Preparation of Nanoparticles by Gas Phase Processes)

  • 김동주;김교선
    • Korean Chemical Engineering Research
    • /
    • 제45권6호
    • /
    • pp.536-546
    • /
    • 2007
  • 나노 미립자는 부피대비 높은 표면적을 가지고 있기 때문에 벌크 상태에서는 볼 수 없는 여러 흥미로운 성질들을 가지고 있다. 나노 미립자들은 나노 구조체 재료, 산업용 재료 혹은 촉매 재료 등을 제조하는데 사용될 수 있다. 기상공정에 의해 높은 단분산성을 갖는 다양한 크기의 나노 미립자를 제조할 수 있으며 제조된 미립자는 각종 첨단 기능성 재료의 원료로 이용될 수 있다. 본고에서는 기상공정을 통하여 나노 미립자 제조에 이용되는 에어로솔 반응기들을 소개하였으며 각 반응기의 특성을 분석하였고 기상 공정에 의한 미립자 제조에 관련된 최근 흥미 있는 연구들을 소개하도록 하였다.

SCR 시스템의 효율적인 운영을 위한 Soot Blowing 방법에 대한 해석적 연구 (Computational Study on the Soot Blowing Method for Enhancing the Performance of the SCR System)

  • 서문혁;장혁상
    • 한국입자에어로졸학회지
    • /
    • 제8권3호
    • /
    • pp.99-110
    • /
    • 2012
  • In the SCR (selective catalytic reduction) system which is used for controlling the NOx emission from the Diesel engines, the soot deposited on the catalysis causes degradation of the system performance. Numerical study was done to evaluate the performance of soot blower which is proposed as a method for removing the soot on the catalysis. The spray conditions and the effect of the compressed air from the AIG (air inlet gun) were analyzed numerically to evaluate the overall effective method of the soot blowing. The characteristics of the final velocity distribution and velocity waves across the inlet section of the catalysis were evaluated with respect to the geometries of the AIG outlets and pressure conditions. An experimental model was used to validate the results of the numerical calculation that is used for finding the effective removal blowing momentum transfer quantities of soot the inlet section of the catalysis, and it is proposed that the required minimum blowing momentum transfer quantities are over than 0.499 $kg/m{\bullet}t_{eff}$ in the current study.

축산관련차량 이동에 따른 도로의 에어로졸 발생량 분석 (Aerosol Emission from Road by Livestock Transport Vehicle Movement)

  • 서일환;이인복;황현섭;배연정;배승종;문운경
    • 농촌계획
    • /
    • 제19권4호
    • /
    • pp.137-147
    • /
    • 2013
  • Most of livestock houses are concentrated in certain area with mass rearing system resulting in rapid spread of infectious diseases such as HPAI (highly pathogenic avian influenza). The livestock-related vehicles which frequently travel between farms could be a major factor for disease spread by means of transmission of airborne aerosol including pathogens. This study was focused on the quantitative measurement of aerosol concentration by field experiment while vehicles were passing through the road. The TSP (total suspended particle) and PM10 (particle matter) were measured using air sampler with teflon filter installed downward the road with consideration of weather forecast and the direction of road. And aerosol spectrometer and video recorders were also used to measure the real-time distribution of aerosol concentration by its size. The results showed that PM2.5 was not considerable for transmission of airborne aerosol from the livestock-related vehicle. The mass generated from the road during the vehicle movement was measured and calculated to 241.4 ${\mu}g/m^3$ by means of the difference between TSP and PM2.5. The dispersion distance was predicted by 79.6 m from the trend curve.

양돈장의 소모성질병 확산 분석을 위한 현장 모니터링 및 공기유동학적 분석 (Aerodynamic Approaches for Estimation of Waste Disease Spread in Pig Farm through Airborne Contaminants)

  • 서일환;이인복;문운경;권경석
    • 한국농공학회논문집
    • /
    • 제56권1호
    • /
    • pp.41-49
    • /
    • 2014
  • Pig chronic wasting disease, including porcine reproductive and respiratory syndrome (PRRS) and postweaning multisystemic wasting syndrome (PMWS), have made a continuous economic damage in pig farms. Airborne spread of livestock viruses are an important spread factor which is difficult to analyze due to invisible airflow and limitation of measurement. The objective of this study is to analyze airborne disease spread between buildings in the experimental pig farm by means of field experiment and computational fluid dynamics (CFD). The field experiments were conducted to capture airborne virus using air sampler and teflon filter along multi points in the experimental pig farm. The samples were tested in terms of virus detection resulting in positive reaction for PRRS and PCV-2 viruses, which can be a firm evidence of airborne virus spread. The CFD simulation model was developed by considering complex topography, wind conditions, building arrangement, and ventilation systems and was used to analyze airborne virus spread according to different wind conditions. The CFD computed result showed a possibility of airborne virus spread via livestock aerosol from infected pig house to neighboring pig houses according to wind directions. The CFD simulation technique is expected to provide significant data for estimating and making a counterplan against airborne disease spread.

실내환기 방식이 재채기 토출입자의 거동특성에 미치는 영향 (Effect of Ventilation Type on the Trajectory of Coughed Particles in a Hospital Ward)

  • 권순박;송지한;조영민;정우태;박덕신
    • 한국입자에어로졸학회지
    • /
    • 제9권2호
    • /
    • pp.59-67
    • /
    • 2013
  • One of purposes in this study was to confirm the behavior of coughed particles under different ventilation conditions. Three types of ventilation systems were applied for this experiment and the properties of coughed particles were measured using computational fluid dynamics (CFD) in an intensive care unit. The changes of total airborne particles for each case showed different trends according to the ventilation type and time, but the deposited particles were similar in all conditions. Although the time taken for 50% of the particles to be deposited was the fastest in case 2, the portion of deposited particles after 300 seconds was only 5% in all conditions. In case 1, a relatively small number of particles were deposited on the wall, but the particle exhaust and deposition on the occupants were the highest. In case 3, the downward ventilation was applied as that recommended by the US Center for Disease Control and Prevention (CDC) and showed different exhaust efficiencies according to the particle size.

A computational study on the removal of the non-isothermal concentrated fume from the semi-enclosed space

  • Chang, Hyuksang;Seo, Moonhyeok;Lee, Chanhyun
    • Environmental Engineering Research
    • /
    • 제22권2호
    • /
    • pp.216-223
    • /
    • 2017
  • For the prediction of the ventilation rate for removing the non-isothermal concentrated fume from the semi-enclosed space, the computational fluid dynamics (CFD) analysis was done. Securing the proper ventilation conditions in emergency state such as in fire is crucial factor for the protection of the resident in the space. In the analysis for the determining the proper ventilation rate, the experimental study had the limitation for simulating the versatile conditions of fume development. The theoretical and computational method had been chosen as the alternate tool for the experimental analysis. In this study, the CFD analysis was done on the defined model which already had been done the experimental analysis by the previous workers. By comparing the prediction on the plume heights and the ventilation rates by the CFD analysis at, and in the parametric model of $1m^3$ with those of the previous experimental works, the feasibility of the computational analysis was evaluated. For the required ventilation rate analyzed by the CFD analysis was over predicted in 7.1% difference with that of the experimental results depending on the different plume height. With the comparison with the analytical Zukoski model at, the CFD analysis on the ventilation was under predicted in 8.3%. By the verification of the feasibility of the CFD analysis, the extended analysis was done for getting the extra information such as the water vapor distribution and $CO^2$ distribution in the semi-enclosed spaces.

에어로솔의 대륙 층운형 구름 연직발달(Invigoration)에 미치는 영향 분석 (An Analysis of Aerosols Impacts on the Vertical Invigoration of Continental Stratiform Clouds)

  • 김유준;한상옥;이철규;이승수;김병곤
    • 대기
    • /
    • 제23권3호
    • /
    • pp.321-329
    • /
    • 2013
  • This study examines the effect of aerosols on the vertical invigoration of continental stratiform clouds, using a dataset of Atmospheric Radiation Measurement (ARM) Intensive Operational Period (IOP, March 2000) at the Southern Great Plains (SGP) site. To provide further support to our observation-based findings, the weather research and forecasting (WRF) sensitivity simulations with changing cloud condensation nuclei (CCN) concentrations have been carried out for the golden episode over SGP. First, cross correlation between observed aerosol scattering coefficient and cloud liquid water path (LWP) with a 160-minutes lag is the highest of r = 0.83 for the selected episode, which may be attributable to cloud vertical invigoration induced by an increase in aerosol loading. Modeled cloud fractions in a control run are well matched with the observation in the perspective of cloud morphology and lasting period. It is also found through a simple sensitivity with a change in CCN that aerosol invigoration (AIV) effect on stratiform cloud organization is attributable to a change in the cloud microphysics as well as dynamics such as the corresponding modification of cloud number concentrations, drop size, and latent heating rate, etc. This study suggests a possible cloud vertical invigoration even in the continental stratiform clouds due to aerosol enhancement in spite of a limited analysis based on a few observed continental cloud cases.

SCR 시스템 내 암모니아 분사 균일도 개선을 위한 AIG 설계에 관한 해석적 연구 (Computational Study on Design of the AIG for the Enhancement of Ammonia Injection in the SCR System)

  • 서문혁;장혁상
    • 청정기술
    • /
    • 제18권4호
    • /
    • pp.410-418
    • /
    • 2012
  • 선택적 촉매환원(selective catalytic reduction, SCR) 시스템에서 사용되는 환원제의 효용성을 극대화하기 위해 적용되는 암모니아주입관(ammonia injection gun, AIG) 성능은 유량의 분배, 공기분배다기관(air distribution manifold, ADM)의 배치 그리고 노즐의 배열 및 형상 등에 의해 영향을 받는다. 본 연구에서는 전산유체역학(computational fluid dynamics, CFD) 기법을 이용하여 AIG 성능의 지표가 되는 토출 유량 균일도를 통계적인 수치로 표현하여 관련된 설계인자들과 SCR 시스템의 성능 사이의 상관관계를 평가하고자 하였다. 관내 유동에서 일어나는 유체역학적인 현상의 영향으로 AIG에 대한 공급유량이 증가할 때 각 노즐에서의 토출 유량의 균일도는 감소하는 해석결과를 얻었으며 헤더로부터 가까울수록 분지관으로의 유량분배율이 낮아짐과 동시에 헤더에 가까운 노즐일수록 토출유량이 적어지는 현상을 파악하였다. 각 분지관에 대해 유입 면적대비 노즐의 총 면적비가 0.5 미만일 때 토출 유량의 균일도와 분지관의 유량분배가 매우 균일해지는 것으로 파악되었다.

모멘트 방법을 이용한 전기집진기의 집진 효율 (Collection Efficiency of Electrostatic Precipitator using Moment Method)

  • 정창훈;이규원
    • 한국대기환경학회지
    • /
    • 제18권5호
    • /
    • pp.345-353
    • /
    • 2002
  • A study of polydispersed aerosol dynamics by Electrostatic Precipitator (ESP) was carried out. The log-normal particle size distribution was assumed and moment method was considered. In order to apply moment method in Deutsch-Anderson equation, Cunningham slip correction factor and Cochet's charge equation were simplified for certain range of particle size. The three parameters, which explain the particle size distribution, such as total number concentration, geometric mean diameter, and geometric standard deviation were considered to derive the analytic solution. The obtained solution was compared with available numerical results (Bai et al., 1995). The comparison of the numerical and analytic results showed a good agreement.