• 제목/요약/키워드: Aerosol density

검색결과 65건 처리시간 0.023초

산업단지내 미세먼지 및 토양입자의 개별입자 분석 (Aerosol Characterization Study for Individual Particle of PM10, PM2.5 Observed in Industrial Area)

  • 이동현;김용석;서정민;최금찬
    • 한국환경과학회지
    • /
    • 제22권1호
    • /
    • pp.7-15
    • /
    • 2013
  • Aerosol characterization study for individual particle in Busan metropolitan industrial complex was carried out from December 2010 to August 2011. SEM(scanning electron microscope)-EDX(energy dispersive x-ray) analysis was used for the analysis of 600 single particles during the sampling periods to identify non-metallic aerosol particle sources. Average $PM_{10}$ concentration was 65.5 ${\mu}g/m^3$ in summer, 104.1 ${\mu}g/m^3$ in winter during the sample periods. And Average $PM_{2.5}$ concentration was 24.5 ${\mu}g/m^3$ in summer, 64.5 ${\mu}g/m^3$ in winter individually. Particle density, enrichment factor, correlation analysis, principle component analysis were performed based on chemical composition data. Particle density distribution was measured to 2~4 $g/cm^3$, and the density of $PM_{2.5}$ was measured above 3 $g/cm^3$. In general, the elements Si, Ca, Fe and Al concentrations were higher in all samples of individual particles. The non-ferrous elements Zn, Br, Pb, Cu concentrations were higher in summer than in winter. The concentrations were not changed with the seasons because of non-ferrous industry emission pattern.

대용량 입자 발생 장치 개발 및 이를 이용한 항바이러스 공조용 공기필터 제조 (Development of mass aerosol particle generator and fabrication of commercial anti-viral air filter)

  • 박대훈;조윤행;황정호
    • 한국입자에어로졸학회지
    • /
    • 제12권4호
    • /
    • pp.151-159
    • /
    • 2016
  • Since airborne viruses have been known to aggravate indoor air quality, studies on development of anti-viral air filter increase recently. In this study, a mass aerosol particle generator for coating a commercial air filter (over $300{\times}300mm^2$) was built, and evaluated by comparing a commercial particle generator. Then, via this device, a commercial air filter was coated with anti-viral material ($SiO_2-Ag$ nanoparticles in this study), so fabrication of commercial anti-viral air filter was performed and the pressure drop, filtration efficiency, and anti-viral ability of the filter were evaluated against aerosolized bacteriophage MS2 in a continuous air flow condition. The result showed that the particle generation of the new generator was more than about 8.5 times over which of the commercial one. Consequently, $SiO_2-Ag$ particle coating on a filter does not have significant effects on the filtration efficiency and pressure drop with different areas, and the average anti-viral efficiency of the $SiO_2-Ag$ filter was about 92% when the coating areal density was $1.0{\times}10^{12}particles/m^2$.

상온분말분사공정을 이용한 고밀도 폴리머-세라믹 혼합 코팅층 제조 및 에너지 저장 특성 향상 (Fabrication of High Density BZN-PVDF Composite Film by Aerosol Deposition for High Energy Storage Properties)

  • 임지호;김진우;이승희;박춘길;류정호;최두현;정대용
    • 한국재료학회지
    • /
    • 제29권3호
    • /
    • pp.175-182
    • /
    • 2019
  • This study examines paraelectric $Bi_{1.5}Zn_{1.0}Nb_{1.5}O_7$ (BZN), which has no hysteresis and high dielectric strength, for energy density capacitor applications. To increase the breakdown dielectric strength of the BZN film further, poly(vinylidene fluoride) BZN-PVDF composite film is fabricated by aerosol deposition. The volume ratio of each composition is calculated using dielectric constant of each composition, and we find that it was 12:88 vol% (BZN:PVDF). To modulate the structure and dielectric properties of the ferroelectric polymer PVDF, the composite film is heat-treated at $200^{\circ}C$ for 5 and 30 minutes following quenching. The amount of ${\alpha}-phase$ in the PVDF increases with an increasing annealing time, which in turn decreases the dielectric constant and dielectric loss. The breakdown dielectric strength of the BZN film increases by mixing PVDF. However, the breakdown field decreases with an increasing annealing time. The BZN-PVDF composite film has the energy density of $4.9J/cm^3$, which is larger than that of the pure BZN film of $3.6J/cm^3$.

Single Crystal Growth Behavior in High-Density Nano-Sized Aerosol Deposited Films

  • Lim, Ji-Ho;Kim, Seung-Wook;Kim, Samjung;Kang, Eun-Young;Lee, Min Lyul;Samal, Sneha;Jeong, Dae-Yong
    • 한국재료학회지
    • /
    • 제31권9호
    • /
    • pp.488-495
    • /
    • 2021
  • Solid state grain growth (SSCG) is a method of growing large single crystals from seed single crystals by abnormal grain growth in a small-grained matrix. During grain growth, pores are often trapped in the matrix and remain in single crystals. Aerosol deposition (AD) is a method of manufacturing films with almost full density from nano grains by causing high energy collision between substrates and ceramic powders. AD and SSCG are used to grow single crystals with few pores. BaTiO3 films are coated on (100) SrTiO3 seeds by AD. To generate grain growth, BaTiO3 films are heated to 1,300 ℃ and held for 10 h, and entire films are grown as single crystals. The condition of grain growth driving force is ∆Gmax < ∆Gc ≤ ∆Gseed. On the other hand, the condition of grain growth driving force in BaTiO3 AD films heat-treated at 1,100 and 1,200 ℃ is ∆Gc < ∆Gmax, and single crystals are not grown.

PIXE 분석에 의한 대기에어로졸의 원소분석 -표준시료의 작성 및 정량화- (PIXE Analysis of Aerosol Particles - Preparation of Standard Samples and Calibration Test -)

  • 崔琴簒
    • 한국대기환경학회지
    • /
    • 제7권2호
    • /
    • pp.114-118
    • /
    • 1991
  • Particle Induce X-Ray Emission (PIXE) analysis is one of the most useful methods which can determine the elemental concentration of aerosol particles in nano-gram range. The main purpose of this paper is to establish the measurement system and the procedure of PIXE analysis. The standard samples were prepared to calibrate the PIXE analysis by three different techniques. The linear relationships between the peak counts from PIXE spectra and the mass density from RBS spectra were obtained for each standardized element under the applied measurment geometry and conditions. The sensitivity curves for PIXE analysis were determined from these relationships.

  • PDF

에어로졸 증착법[aerosol depostion method]에 의한 $Ba[Ce_{0.9}Y_{0.1}]O_{3-\delta}$ - Ni 수소분리막 제조 ($Ba[Ce_{0.9}Y_{0.1}]O_{3-\delta}$ - Ni Composite Membrane for Hydrogen Separation by Aerosol Deposition Method)

  • 박영수;변명섭;최진섭;김진호;황광택
    • 한국수소및신에너지학회논문집
    • /
    • 제21권2호
    • /
    • pp.117-122
    • /
    • 2010
  • BCY($Ba(Ce_{0.9}Y_{0.1})O_{3-\delta}$) oxide, shows high protonic conductivity at high temperatures, and are referred to as hydrogen separation membrane. For high efficiency of hydrogen separation ($H_2$ flux and selectivity) and low fabrication cost, ultimate thin and dense BCY-Ni layer have to be coated on a porous substrate such as $ZrO_2$. Aerosol depostion (AD) process is a novel technique to grow ceramic film with high density and nano-crystal structure at room-temperature, and would be applied to the fabrication process of AD integration ceramic layer effectively. XRD and SEM measurements were conducted in order to analyze the characteristics of BCY-Ni membrane fabricated by AD process.

Study on the possibility of the aerosol and/or Yellow dust detection in the atmosphere by Ocean Scanning Multispectral Imager(OSMI)

  • Chung, Hyo-Sang;Park, Hye-Sook;Bag, Gyun-Myeong;Yoon, Hong-Joo;Jang, Kwang-Mi
    • 대한원격탐사학회:학술대회논문집
    • /
    • 대한원격탐사학회 1998년도 Proceedings of International Symposium on Remote Sensing
    • /
    • pp.409-414
    • /
    • 1998
  • To examine the detectability of the aerosol and/or Yellow dust from China crossing over the Yellow sea, three works carried out as follows , Firstly, a comparison was made of the visible(VIS), water vapor(WV), and Infrared(IR) images of the GMS-5 and NOAA/AVHRR on the cases of yellow sand event over Korea. Secondly, the spectral radiance and reflectance(%) was observed during the yellow sand phenomena on April, 1998 in Seoul using the GER-2600 spectroradiometer, which observed the reflected radiance from 350 to 2500 nm in the atmosphere. We selected the optimum wavelength for detecting of the yellow sand from this observation, considering the effects of atmospheric absorption. Finally, the atmospheric radiance emerging from the LOWTRAN-7 radiative transfer model was simulated with and without yellow sand, where we used the estimated aerosol column optical depth ($\tau$ 673 nm) in the Meteorological Research Institute and the d'Almeida's statistical atmospheric aerosol radiative characteristics. The image analysis showed that it was very difficult to detect the yellow sand region only by the image processing because the albedo characteristics of the sand vary irregularly according to the density, size, components and depth of the yellow sand clouds. We found that the 670-680 nm band was useful to simulate aerosol characteristics considering the absorption band from the radiance observation. We are now processing the simulation of atmospheric radiance distribution in the range of 400-900 nm. The purpose of this study is to present the preliminary results of the aerosol and/or Yellow dust detectability using the Ocean Scanning Multispectral Imager(OSMI), which will be mounted on KOMPSAT-1 as the ocean color monitoring sensor with the range of 400-900 nm wavelength.

  • PDF

하이브리드 수용모델을 이용한 서울시 PM2.5 오염원의 위치 추적 (Identification of Potential Source Locations of PM2.5 in Seoul using Hybrid-receptor Models)

  • 강병욱;강충민;이학성;선우영
    • 한국대기환경학회지
    • /
    • 제24권6호
    • /
    • pp.662-673
    • /
    • 2008
  • Two hybrid receptor models, potential source contribution function (PSCF) and concentration weighted tracjectory (CWT), were compared for locating $PM_{2.5}$ sources contributing to the atmospheric $PM_{2.5}$ concentrations in Seoul. The source contribution estimates by chemical receptor model (CMB) receptor model were used to identify better source areas, Among the sources, soil, agricultural burning, marine aerosol, coal-fired power plant and Chinese aerosol were only considered for the study because these sources were more likely to be associated with the long-range transport of air pollutant. Both methods are based on combining chemical data with calculated air parcel backward trajectories. However, the PSCF analyses were performed with trajectories above the $75^{th}$ percentile criterion values, while the CWT analyses used all trajectories. This difference resulted in locating of different sources, which might be helpful to interpret locating of $PM_{2.5}$ sources, High possible source areas in source contribution of soil and agricultural burning contributing to the Seoul $PM_{2.5}$ were inland areas of Heibei and Shandong provinces (highest density areas of agricultural production and population) in China. The "Chinese aerosol" was used as a representative source for the $PM_{2.5}$ originated from urban area in China. High possible source areas for the aerosol were the cities in China where are relatively close to the receptor. This result suggests that Chinese aerosol is likely to be a useful tool in studies on source apportionment and identification in Korea.

Development of a Real-time Monitoring Device for Measuring Particulate Matter

  • Kim, Dae Seong;Cho, Young Kuk;Yoon, Young Hun
    • 한국입자에어로졸학회지
    • /
    • 제10권1호
    • /
    • pp.1-8
    • /
    • 2014
  • In this study, we have developed a real-time monitoring device for measuring $PM_{10/2.5/1}$ of ambient aerosol particles. The real-time PM (Particulate Matter) monitor was based on the light scattering method and had 16 channels in particle size. The laboratory and field tests were carried out to evaluate the performance of the PM monitor developed. Arizona Road Dust particles ranging from diameter of 0.1 to $20{\mu}m$ were generated as test particles in the laboratory test. The field test was carried out at the Seoul Meteorological Observatory. We can obtain the particle size and number concentration (particle size distribution) only from the real-time PM monitor developed. Therefore, the average density of aerosol particles was used to obtain the PM data from the particle size distribution. The $PM_{10/2.5/1}$ results of the PM monitor were compared with the data of the Grimm Dust Monitor (Model 1.108) and a beta ray gauge (Thermo Fisher Scientific). As a result, it was shown that the $PM_{10/2.5/1}$ results obtained by the real-time PM monitor agreed well with the data of the reference devices, and overall, the real-time PM monitor could be used as a PM monitoring device for real-time monitoring of the ambient particles.

실시간 에어로졸 측정장비를 이용한 대기 중 입자상 물질의 무게 농도 분포의 추정 (Estimation of Mass Size Distribution of Atmospheric Aerosols Using Real-Time Aerosol Measuring Instruments)

  • 지준호;배귀남
    • 한국입자에어로졸학회지
    • /
    • 제9권2호
    • /
    • pp.39-50
    • /
    • 2013
  • SMPS, APS, ELPI는 실시간으로 대기 중 입자상 물질을 측정할 수 있는 장비로 많은 연구자들에 의해 사용되고 있다. 하지만 측정장비의 특성과 입자 분류 특성에 대한 충분한 이해가 없다면, 단순히 장비에 제공된 소프트웨어의 계산 결과를 여과 없이 그대로 사용할 수밖에 없다. 본 연구에서는 SMPS, APS, ELPI의 측정 메커니즘을 간단히 정리하였고, 전기적 이동도로 입자를 분리하는 SMPS와 공기역학적 거동을 이용하는 APS를 함께 사용하여 입자의 크기분포를 측정할 때 발생할 수 있는 문제점을 고찰하였다. 크기분포 측정결과를 이용해서 무게 농도를 환산하는 과정에서 대기 입자의 입경에 따른 밀도 정보를 제공하는 것이 매우 중요하다는 것을 보였다. 특히, APS 측정결과를 이용하는 경우 무게 농도의 추정 결과가 크게 영향을 받았다. ELPI의 경우 입자 밀도를 정확히 설정하지 않으면 입자의 수 농도에 오차가 크게 발생할 수 있으므로, 정확한 밀도를 설정하는 것이 중요했다. 반면에 ELPI로 대기 중입자상 물질의 무게 농도를 추정하는 경우 밀도가 실제와 다르게 설정되더라도 공기역학적 입경으로 나타내면 총 무게 농도는 수 농도에 비해 상대적으로 영향이 적었다. 향후 SMPS와 APS를 이용하여 시간에 따른 크기 분포 변화와 연간 수 농도와 무게 농도의 변화 추이를 측정하는 연구가 필요하다. 특히, 국내 대기 중입자의 입경에 따른 평균 밀도 혹은 유효 밀도를 측정하여 크기분포와 총 수 농도 혹은 PM2.5나 PM1에 해당하는 무게 농도를 정확하게 계산할 수 있는 데이터 환산 프로그램의 개발도 필요하다. 이와 같은 연구로 시간경과에 따라 변화하는 대기 입자의 오염원에 대한 영향을 규명하는 기초 자료를 얻을 수 있을 것이다.