• Title/Summary/Keyword: Aerosol Model

Search Result 309, Processing Time 0.025 seconds

DISPERSION OF AN AEROSOL BOLUS IN THE ALVEOLAR DUCT (폐포가 달린 도관 내에서의 입자의 분산)

  • Lee DongYoub;Lee JinWon
    • Proceedings of the KSME Conference
    • /
    • 2002.08a
    • /
    • pp.697-698
    • /
    • 2002
  • The dispersion of an aerosol bolus in acinus is analyzed numerically. Model geometry is a straight duct surrounded by an axisymmetric semicircular annulus which is expanding or contracting with breathing. Unsteady Wavier-Stokes equation is solved by CFX-F3D, an FVM commercial code and the trajectory of massless particle Is computed by Lagrangian method. For steady flow with no wall motion, mean velocity of aerosol bolus in alveolated duct is a little smaller than that in straight duct and dispersion in alveolated duct is comparable with the dispersion in straight tube. For expanding duct mean velocity of aerosol bolus approaches half of that in straight tube and effective diffusivity is smaller than that of straight tube. For contracting duct mean velocity of aerosol bolus becomes slightly larger than that in straight tube and effective diffusivity is comparable with the case of straight tube.

  • PDF

Attenuation of the Atmospheric Aerosol Transmissivity due to Air Pollution (대기오염에 의한 대기투과도 감쇠에 대한 연구)

  • Kim, Yoo-Keun;Lee, Hwa-Woon;Lee, Yong-Seob
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.11 no.E
    • /
    • pp.23-29
    • /
    • 1995
  • Relationship between atmospheric aerosol transmissivity and air pollution was analyzed using observed data in a large industrial city, Pusan, Korea. The atmospheric aerosol transmissivity predicted by method of present study in Pusan was assessed by the method of Yamamoto et al.(1968) in order to set up an empirical model to predict the transmissivity using the various meteorological parameters and air pollution. As a result, good correlation between these tow method re observed. Thus, it is possible to conclude that the parameterization of air pollution suggested by this study is another method to give reliable estimate of atmospheric aerosol transmissivity and direct solar irradiance in Pusan.

  • PDF

Aerosol Generation Mechanism for Cutting Fluid in Turning (선삭에서 절삭유 미립화 생성 메카니즘)

  • 박성호;고태조;김희술
    • Proceedings of the Korean Society of Machine Tool Engineers Conference
    • /
    • 2001.10a
    • /
    • pp.179-184
    • /
    • 2001
  • The mechanism of the aerosol generation consists of spin-off, splash, and evaporation/condensation. Most researchers showed some theoretical model for predicting the particulate size and generation rate without cutting in turning operation. These models were based on the spin-off mechanism and verified good for modeling the process. However, in real machining, the cutting tool destructs the spin-off process, and the majority of the mist is due to splash. In this paper, we show some experimental evidence the aerosol generation mechanism should be explained with splash model as well as spin-off.

  • PDF

Experimental Verification of Aerosol Generation Mechanism for Cutting Fluid in Turning (선삭에서 절삭유 미립화 생성 메카니즘의 실험적 검증)

  • 고태조;오명석;박성호;김희술
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.19 no.12
    • /
    • pp.93-99
    • /
    • 2002
  • The mechanism of the aerosol generation generally consists of spin-off, splash, and evaporation/condensation. Most researchers showed some theoretical model for predicting the particulate size and generation rate without real cutting in turning operation. These models were based on the spin-off mechanism, and verified good for modeling the process. However, in real machining, the cutting tool destroys the spin-off process, and the majority of the mist is due to splash. In this paper, we show some experimental evidence that the aerosol generation mechanism in real machining should be explained with splash model as well as spin-off.

A Theoretical Study on Wet Scavenging of Atmospheric Aerosols by Rain Drops (대기에어로졸 입자의 이론적 강수세정에 관한 연구)

  • 박정호;최금찬
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.15 no.1
    • /
    • pp.1-11
    • /
    • 1999
  • In this work, a theoretical model has been formulated which allows the study of the scavenging efficiencies of aerosol particles by the rain drops. Aerosol particles are scavenged by the simultaneous brownian diffusion, interception and inertial impaction force. In addition the calculations based on the collision efficiency model are carried out for the collision of aerosol particles with diameter range 0.01~30 $mu extrm{m}$ and rain drops with diameter 0.02$\times$$2^{n/3}$(n=1, 2, …, 17)cm. The results indicate that: (1) the below-cloud scavenging affects mainly the coarse particles (>3 ${\mu}{\textrm}{m}$), the fine particles remaining almost unchanged; (2) the scavenging efficiencies by below-cloud in the heavy rain (rain intensity, 10 mm/hr) surpass the efficiency found in the drizzle rain (rain intensity, 1 mm/hr).

  • PDF

Effects of Aerosolized Sanitizers of Different Droplet Sizes on Foodborne Pathogen Reduction

  • Kim, Young-Ho;Jo, Young-Jun;Kim, Yun-Ji;Koo, Min-Seon;Lee, Jong-Kyung;Oh, Se-Wook
    • Food Science and Biotechnology
    • /
    • v.17 no.3
    • /
    • pp.664-668
    • /
    • 2008
  • The diffusivity of aerosol sanitizers may be determined by the weight and droplet size of the aerosol. To test the effects of droplet size, 2 types of aerosol sanitizers were prepared using different ultrasonic nebulizer frequencies (1.6 and 2.4 MHz) and their reduction activities were determined against Escherichia coli O157:H7, Listeria monocytogenes, and Salmonella typhimurium. A sodium hypochlorite aerosol was treated for 10, 30, or 60 min in a model aerosol cabinet. When the aerosol prepared by nebulizing at 1.6 MHz was treated for 30 min, a 0.2 log reduction was observed in E. coli O157:H7 and 0.3 log reductions were exhibited in L. monocytogenes and S. typhimurium, respectively. After 60 min, the 3 pathogens were reduced by 1.7, 0.6, and 0.8 log units, respectively. However, when the aerosol prepared by nubulizing at 2.4 MHz was treated, the microbes presented 1.6, 0.5, and 0.6 log reductions at 30 min, and 1.8, 0.9, and 1.1 log reductions at 60 min of treatment, respectively.

Design and Performance Evaluation of a Faraday Cage and an Aerosol Charger (패러데이 케이지와 에어로졸 하전기의 설계 및 성능평가)

  • Ji, Jun-Ho;Bae, Kwi-Nam;Hwang, Jung-Ho
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.28 no.3
    • /
    • pp.315-323
    • /
    • 2004
  • An electrical cascade impactor is a multi-stage impaction device to separate airborne particles into aerodynamic size classes using particle charging and electrical detection techniques. A Faraday cage and an aerosol charger, which are basic components of the electrical cascade impactor, were designed and evaluated in this study. The low-level current response of the Faraday cage was investigated with changing particle size and air flow rate by using sodium chloride (NaCl) particles. The response of the prototype Faraday cage was very similar to that of a commercial aerosol electrometer (TSI model 3068) within ${\pm}$5% for singly-charged particles. The response linearity of the prototype Faraday cage could be extended up to flow rate of 30 L/min. For the performance evaluation of the aerosol charger the monodisperse liquid dioctyl sebacate (DOS) particles, with diameters of 0.1∼0.8$\mu\textrm{m}$, were generated using spraying from an atomizer followed by evaporation-condensation process. Typical performance parameters of the aerosol charger such as P$.$n, wall loss, and elementary charges per particle were evaluated. The performance of the prototype aerosol charger was found to be close to that of the aerosol charger used in an electrical low pressure impactor (ELPI, Dekati).

Investigation of the Optical and Cloud Forming Properties of Pollution, Biomass Burning, and Mineral Dust Aerosol

  • Lee Yong-Seop
    • Proceedings of the Korea Air Pollution Research Association Conference
    • /
    • 2006.04a
    • /
    • pp.55-56
    • /
    • 2006
  • This thesis describes the use of measured aerosol size distributions and size-resolved hygroscopic growth to examine the physical and chemical properties of several particle classes. The primary objective of this work was to investigate the optical and cloud forming properties of a range of ambient aerosol types measured in a number of different locations. The tool used for most of these analyses is a differential mobility analyzer / tandem differential mobility analyzer (DMA / TDMA) system developed in our research group. To collect the data described in two of the chapters of this thesis, an aircraft-based version of the DMA / TDMA was deployed to Japan and California. The data described in two other chapters were conveniently collected during a period when the aerosol of interest came to us. The unique aspect of this analysis is the use of these data to isolate the size distributions of distinct aerosol types in order to quantify their optical and cloud forming properties. I used collected data during the Asian Aerosol Characterization Experiment (ACE-Asia) to examine the composition and homogeneity of a complex aerosol generated in the deserts and urban regions of China and other Asian countries. An aircraft-based tandem differential mobility analyzer was used for the first time during this campaign to examine the size-resolved hygroscopic properties of particles having diameters between 40 and 586 nm. Asian Dust Above Monterey (ADAM-2003) study was designed both to evaluate the degree to which models can predict the long-range transport of Asian dust, and to examine the physical and optical properties of that aged dust upon reaching the California coast. Aerosol size distributions and hygroscopic growth are measured in College Station, TX to investigate the cloud nucleating and optical properties of a biomass burning aerosol generated from fires on the Yucatan Peninsula. Measured aerosol size distributions and size-resolved hygroscopicity and volatility were used to infer critical supersaturation distributions of the distinct particle types that were observed during this period. The predicted CCN concentrations were used in a cloud model to determine the impact of the different aerosol types on the expected cloud droplet concentration. RH-dependent aerosol extinction coefficients are calculated at a wavelength of 550 nm.

  • PDF

Advanced Forecasting Approach to Improve Uncertainty of Solar Irradiance Associated with Aerosol Direct Effects

  • Kim, Dong Hyeok;Yoo, Jung Woo;Lee, Hwa Woon;Park, Soon Young;Kim, Hyun Goo
    • Journal of Environmental Science International
    • /
    • v.26 no.10
    • /
    • pp.1167-1180
    • /
    • 2017
  • Numerical Weather Prediction (NWP) models such as the Weather Research and Forecasting (WRF) model are essential for forecasting one-day-ahead solar irradiance. In order to evaluate the performance of the WRF in forecasting solar irradiance over the Korean Peninsula, we compared WRF prediction data from 2008 to 2010 corresponding to weather observation data (OBS) from the Korean Meteorological Administration (KMA). The WRF model showed poor performance at polluted regions such as Seoul and Suwon where the relative Root Mean Square Error (rRMSE) is over 30%. Predictions by the WRF model alone had a large amount of potential error because of the lack of actual aerosol radiative feedbacks. For the purpose of reducing this error induced by atmospheric particles, i.e., aerosols, the WRF model was coupled with the Community Multiscale Air Quality (CMAQ) model. The coupled system makes it possible to estimate the radiative feedbacks of aerosols on the solar irradiance. As a result, the solar irradiance estimated by the coupled system showed a strong dependence on both the aerosol spatial distributions and the associated optical properties. In the NF (No Feedback) case, which refers to the WRF-only stimulated system without aerosol feedbacks, the GHI was overestimated by $50-200W\;m^{-2}$ compared with OBS derived values at each site. In the YF (Yes Feedback) case, in contrast, which refers to the WRF-CMAQ two-way coupled system, the rRMSE was significantly improved by 3.1-3.7% at Suwon and Seoul where the Particulate Matter (PM) concentrations, specifically, those related to the $PM_{10}$ size fraction, were over $100{\mu}g\;m^{-3}$. Thus, the coupled system showed promise for acquiring more accurate solar irradiance forecasts.

Comparison Study of the TSI Aerodynamic Particle Sizer 3321, Grimm Aerosol Spectrometer 1.109 and HCT Particle Sensor 3030 for PM2.5 measurement (TSI Aerodynamic Particle Sizer 3321, Grimm Aerosol Spectrometer 1.109, HCT Particle Sensor 3030을 이용한 PM2.5 측정결과 비교)

  • Kim, Du-Yong;Chung, Hyuck;Park, Jae-Hong;Hyun, Jun-Ho;Hwang, Jungho
    • Particle and aerosol research
    • /
    • v.8 no.1
    • /
    • pp.9-15
    • /
    • 2012
  • Three different commercial particle counters were used to measure the PM2.5 particles in this study. An Aerosol Spectrometer (AS) 1.109 model of Grimm and a Particle Sensor (PS) 3030 model of HCT were compared with an Aerodynamic Particle Sizer (APS) 3321 model of TSI. The responses of these instruments were compared for four sizes ($1.0{\mu}m$, $1.5{\mu}m$, $2.0{\mu}m$ and $2.5{\mu}m$) of polystyrene latex (PSL) particles and indoor air particles of the office room. The mode diameter, particle size distribution and total particle number concentration of PSL particles were measured by each instrument. In the office room, the total particle number concentration was measured for 25 minutes. In results of particle size distribution and mode diameter, the APS 3321 (52 size-channels) was more accurate than the AS 1.109 (31 size-channels) and PS-3030 (10-szie channels) since the APS has more number of size-channels than the other instruments. However, AS 1.109 and PS-3030 provided similar results of total particle number concentration to those from the APS 3321. In results of office room test, there were no significant difference from each instrument similar to results of PSL test.