• Title/Summary/Keyword: Aeration tank

Search Result 143, Processing Time 0.024 seconds

Characteristics of Sludge Bulking Caused by Low Dissolved Oxygen in Aeration Tank for Paper Mill Wastewater Treatment (포기조의 낮은 용존산소로 인한 제지폐수의 슬러지 팽화특성)

  • Kwak, Dong-Heui;Yoo, Seung-Joon;Park, Jong-Chun
    • Journal of Korean Society on Water Environment
    • /
    • v.24 no.4
    • /
    • pp.458-464
    • /
    • 2008
  • Bulking phenomena and scum formation are common problem in suspended growth system like the activated sludge plants for wastewater treatment. Apart from wastewater composition, operating conditions, such as mechanical stress by insufficient oxygen supply, are often decisive for the occurrence of a bulking or scumming problem. There were the comparative aeration tanks in terms of sludge bulking caused by the difference of mechanical aeration facilities in the wastewater treatment plant of N paper mill company. In this study the cause of bulking was investigated through not only the biological isolation and identification but also a series of operational data consideration. On the basis of the investigation results for bulking cause, the operational criteria on dissolved oxygen concentration was derived to decrease the bulking problem.

Fuzzy algorithm of Automatic control for dissolved oxygen in Activated sludge aeration tank (활성슬러지 폐수처리장 폭기조 DO제어를 위한 퍼지 제어 알고리즘 연구)

  • 손건태;김성덕;고주형
    • Journal of Environmental Science International
    • /
    • v.8 no.4
    • /
    • pp.533-538
    • /
    • 1999
  • Fuzzy algorithm of automatic control for dissolved oxygen(DO) concentration in the aeration tank of an activated sludge process is proposed. Among variables repirometry and air flowrate are selected as significant input factors and the relationship with DO is estimated using a multiple regression model. The DO concentration and the amount of repirometry are fuzzified and the fuzzy rule base are determined. Using the fuzzy algorithm, the change of amount of air flowrate are determined and the change of amount of DO is derived.

  • PDF

Isolation and Charaterization of Dye-Degrading Microorganisms for Treatment of Chromaticity Contained in Industrial Dyeing Wastewater (염색공단폐수의 색도처리를 위한 염료분해 균주의 분리와 특성)

  • Kim, Jung Tae;Park, Guen Tae;Lee, Geon;Kang, Kyeong Hwan;Kim, Joong Kyun;Lee, Sang Joon
    • Journal of Environmental Science International
    • /
    • v.23 no.1
    • /
    • pp.129-142
    • /
    • 2014
  • To treat chromaticity contained in effluents of dyeing wastewater efficiently, potent dye-degrading microorganisms were isolated from influent water, aeration- tank sludge, recycle water and settling-tank sludge located in leather and dyeing treatment plant. Six potent strains were finally isolated and identified as Comamonas testosteroni, Methylobacteriaceae bacterium, Stenotrophomonas sp., Kluyveromyces fragilis, Ascomycetes sp. and Basidiomycetes sp. When Basidiomycetes sp. was inoculated into ME medium containing basal mixed-dyes, 93% of color was removed after 8 days incubation. In the same experiment, the 1:1 mixed culture of Basidiomycetes sp. and photosynthetic bacterium exhibited 88% of color removal; however, it showed better color removal for single-color dyes. The aeration-tank and settling-tank samples revealed higher color removal (95-96%) for black dyes. The settling-tank sample also revealed higher color removal on basal mixed-dyes, which resulted in 90% color removal after 6-h incubation. From the above results, it is expected to achieve a higher color removal using the mixed microorganisms that were isolated from aeration-tank and settling-tank samples.

Effect of Agitation and Aeration Rate on Nicotiana tabacum Suspension Cell Culture in Bioreactors (Bioreactor를 이용한 담배세포 현탁배양에서 교반형태와 통기량이 미치는 영향)

  • Lee, Sang-Yun;Kim, Dong-Il
    • KSBB Journal
    • /
    • v.14 no.5
    • /
    • pp.534-538
    • /
    • 1999
  • For the optimization of operating conditions for plant cell suspension culture in bioreactors, effects of bioreactor types, various kinds of impellers, and aeration rates were examined using Nicotiana tabacum cells as a model system. Stirred tank bioreactor and airlift bioreactor were used for the comparison of bioreactor type. Growth rates in both bioreactors were lower than in shake flasks. In terms of final cell concentration, stirred tank bioreactor supported a little bit better growth compared to airlift bioreactor. Impeller type did not affect cell growth significantly, but it was apparent that cell size index decreased in the case of using hollowed paddle impeller. When the aeration rate was maintained at 0.3 vvm, cell growth was the best. At above 1.0 vvm, growth inhibition as well a browning was noticed. In addition, it was found that cell size index reduced proportionally to the increased of aeration rate.

  • PDF

Evaluation of Diagnosis-based Control Strategy for NH4-N and NOX-N Removal of a Full-scale Wastewater Treatment Process (하수처리시설의 질산화 진단기반 제어 방법의 개발 및 실규모 플랜트 적용을 통한 평가)

  • Kim, Yejin;Kim, Hyosoo
    • Journal of Environmental Science International
    • /
    • v.27 no.6
    • /
    • pp.447-456
    • /
    • 2018
  • In this research, the target process was a modified type of a conventional aeration tank with four different influent feeding points and alternated aeration to obtain nitrogen removal. For more accurate switching of influent feeding, the process was operated under a designed control strategy based on monitoring of $NH_4-N$ and $NO_X-N$ concentrations in the tank. However, the strategy did have some limitations. For example, it was not sensitive to detecting the end of each reaction when losing the balance between nitrification and denitrification of each opposite part of biological tank. To overcome the limitations of the existing control strategy, a diagnosis-based control strategy was suggested in this research using the diagnosis results classified as normal (N), ammonia accumulation (AA) and nitrate accumulation (NA). Using the pre-designed rules for control actions, the aeration and volume of the aerated part of the reactor could be increased or decreased at a fixed mode time. In simulations of the suggested diagnosis-based control strategy, the $NH_4-N$ and $NO_X-N$ removal rates in the reactor were maintained at higher levels than those of the existing control strategy.

Sedimentation and EPS Production by the Change of Dissolved Oxygen Concentration for the Aeration Tank to treat Wastewater with Bacillus sp. (바실러스 미생물을 이용한 하수처리에서 포기조의 DO농도 변화에 따른 EPS 물질생성과 슬러지 침강성에 관한 연구)

  • Lee, Sang-Ho;Son, Han-Hyung
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.8 no.3
    • /
    • pp.627-631
    • /
    • 2007
  • The factors affecting on sludge sedimentation are reported as F/M ratio, ingredient, composition of influent substrate, dissolved oxygen concentration, temperature, pH, filamentous bacteria and SRT. Aeration tank applying Bacillus sp. has an important role for maintaining the dominant microorganism species to make steady progress for spore growth affecting sedimentation. This research aims to investigate the affecting factor for the sedimentation in B3 system and RABC system with aeration tank applying tapered aeration. Extracellular polymeric substances(EPS), protein and carbohydrate can be produced for the extreme condition, that is down to 0.2 mg/L of dissolved oxygen in the aeration tank. This research found out the relation between the sedimentation and the EPS production, especially the ratio of protein/carbohydrate. The spore of Bacillus sp. was formed at the low DO then microorganisms produced EPS. The results showed that the production of EPS was 109.95 mgEPS/gSS at 1.6 mg/L of DO, however it was 131.77 mgEPS/gSS at 0.5 mg/L of DO. The sedimentation was affected by protein content in EPS and the ratio of protein and carbohydrate. The settleability of sludge was not affected by the ratio of protein/carbohydrate in B3 process, meanwhile settleability was affected by the ratio of it in RABC process, respectively.

  • PDF

Performance of Airlift Pumps for Water Circulation and Aeration (물 순환 및 에어레이션용 에어리프트 펌프의 성능)

  • OH Se-Kyung
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.25 no.6
    • /
    • pp.529-537
    • /
    • 1992
  • Airlift pumps were tested to evaluate their pumping and aeration capacities. The pumps were 34.5 inch long made of 2, 3, 4 and 6 inch nominal diameter PVC pipes. An one hp air blower was used to supply the air. The air-flow rate was measured by an anemometer type air-flow meter and air pressure was level changes in a water tank from which water was pumped. Aeration by the pumps was tested by the standard aeration test method with the center of pump outlet positioned 3 inches above water surface. Oxygen concentrations in water were measured to determine aeration rate. As pumping head increased by water level draw-down in the tank water flow decreased while air flow increased. The reduction rate of water flow was higher with 4 and 6-inch pumps. Small pumps showed very minor changes in the reduction. Aeration rates were similar among 3, 4, and 6 inch pumps. With one hp air blower 6-inch pump at the minimum pumping head achieved the best performance in terms of water circulation.

  • PDF

Improvement of treatment efficiency for sanitary treatment facilities by process modifications (분뇨처리장의 공정개선에 의한 처리효율 향상에 관한 연구)

  • Lee, Chan Won;Kim, Seung Hyeon;Kim, Chang Su;Mun, Seong Won;Jeon, Hong Pyo;Yun, Jong Seop
    • Journal of Environmental Science International
    • /
    • v.13 no.6
    • /
    • pp.571-579
    • /
    • 2004
  • There is a need to improve the efficiency of the existing sanitary treatment facilities, because the effluent standard becomes more stricter and septic sludge increased. Thus, operating processes of sanitary treatment system in M city changed with installation of additional facilities. Process modifications were as follows: Dilution water was added to the next process after primary aeration tank. Some secondary sedimentation sludge was recycled to primary aerator so that most of the organics were stabilized in primary aeration tank under automatic control of dissolved oxygen. The line of effluent from dewatering process flowing to the activated sludge tank was changed to the primary aerator. The primary sedimentation sludge line was linked to a thickener. Polymer was added to the activated sludge tank. The effluent of primary aerator and aerobic digester was recycled from the 5th to the 1st sector. As consequencies of above process modifications, the improvement of removal efficiency was achieved as BOD 54%, COD 42%, SS 61%, T-N 39%, and T-P 12%, respectively.

Removal Characteristic of Nitrogenous Compounds According to the Combination of Feeding Ratio between the Supernatant of Precipitation Tank and Raw Domestic Wastewater (침전조 상등액과 유입하수의 유량대비에 따른 하수 내 질소 화합물 제거특성)

  • Park, Sang Min;Park, Jin Hee
    • Journal of the Korea Organic Resources Recycling Association
    • /
    • v.13 no.4
    • /
    • pp.128-135
    • /
    • 2005
  • This study was done to improve the effectiveness of nitrification and denitrification using the aeration-anoxic combination method using CFSTR(continuous-flow stirred-tank reactor) attached with an anoxic reactor filled with a media. In order to calculate the concentration of nitric acid within the aeration tank proportional to the anoxic rate within the reactor, supernatant within the inflow and precipitation tanks were influxed into the anoxic reactor. The rate of nitrogen removal was calculated using the concentration of inflow and flow of returned supernatant. From the results of this experiment, the carbon source needed in the anoxic reactor came from the inflow so that anoxification was achieved completely using the inflow source without the introduction of an external carbon source. However, as the ratio of nitric acid becomes large in inflow and nitric acid flow, the carbon source within the input source decreases so that the concentration of carbon source is important.

  • PDF

Distribution and Characteristics of Culturable Airborne Bacteria and Fungi in Municipal Wastewater Treatment Plants (하수처리시설에서 배양 가능한 공기중 미생물의 분포 및 특성)

  • Park, Kyo-Nam;Koh, Ji-Yun;Jeong, Choon-Soo;Kim, Jong-Seol
    • Korean Journal of Microbiology
    • /
    • v.47 no.1
    • /
    • pp.38-49
    • /
    • 2011
  • Bioaerosols generated from wastewater treatment plants may create health risks for plant workers and nearby residents. To determine the levels of culturable airborne bacteria and fungi in bioaerosols, samples were seasonally collected above and near the aeration tanks of one feces-urine and three sewage treatment plants in Ulsan, Korea with an impaction-type sampler. In the feces-urine treatment plant, concentrations of heterotrophic bacteria were between $1.3({\pm}0.2){\times}10^3$ and $2.6({\pm}1.2){\times}10^4$ MPN/$m^3$ above the aeration tank and between $1.7({\pm}1.0){\times}10^2$ and $7.2({\pm}2.2){\times}10^3$ MPN/$m^3$ near the aeration tank. Coliform bacteria were detected both above and near the aeration tank. In cases of sewage treatment plant, the numbers of heterotrophic bacteria ranged from $1.9({\pm}1.2){\times}10^1$ to $1.8({\pm}1.2){\times}10^4$ MPN/$m^3$ above the aeration tank and from $5.0({\pm}2.8){\times}10^0$ to $6.6({\pm}2.0){\times}10^3$ MPN/$m^3$ near the aeration tank. At reference sites, the concentrations of heterotrophs in ambient air were measured between $7.0{\times}10^0$ and $2.7{\times}10^1$ MPN/$m^3$. When we isolated and tentatively identified heterotrophic bacteria, Pseudomonas luteola was the most dominant species in bioaerosols from wastewater treatment plants, whereas the most abundant one in reference samples was Micrococcus sp. When we measured fungal concentrations in bioaerosols, they were rather similar regardless of sampling locations and seasons, and such genera as Cladosporium, Alternaria, and Penicillium were commonly identified.