• 제목/요약/키워드: Aeration tank

검색결과 144건 처리시간 0.02초

활성오니처리 장해의 규명과 그 제어에 관한 연구 (A Study on the Explanation of Activated Sludge Treatment Hindrance and its Control)

  • 최택열
    • 한국환경보건학회지
    • /
    • 제20권2호
    • /
    • pp.28-38
    • /
    • 1994
  • New problems have been recently posed on the abnormal foaming (Scum) in an aeration tank and the sludge flotation in a final sedimentation tank during the activated sludge process. However, the activities of the causing bacteria, Nocardia-amarae in an aeration tank have not been searched out at all. Therefore, in this article the activities of Nocardia-amarae in an aeration tank have been closely examined by means of the changes of (F/M) ratio, SRT and inflowing substrate using continuous type and fed-batch type. Summarized results of experiments are as follows. 1. Regrading continuous culture when synthetic wastewater was used substrate neither the increase in the number of Nocardia-amarae in the aeration tank nor the Occurrence of Scum was observed. 2. In the case of fed-batch culture, Nocardia-amarae in the aeration tank increased due to the partial change in substrate and the effect of SRT was significant. 3. Once the scum was formed and the quantity of added Nocardia-amarae and substrate were not changed, the effect of STR was not significant.

  • PDF

담체설치가 고질소함유 양돈폐수의 호기발효에 미치는 영향 (Effects of Artificial Filaments Equipped in the Aeration Tank of Aerobic Fermentation System on the Removal Efficiency of Nitrogen of Swine Wastewater Containing High Nitrogen)

  • 손경호;이상락;안정제;권윤정;정태영
    • 한국축산시설환경학회지
    • /
    • 제6권2호
    • /
    • pp.65-72
    • /
    • 2000
  • This study was conducted to investigate the effects of artificial filaments equipped in the aeration tank of aerobic·fermentation system on the removal efficiency of swine wastes which were fermented an aerobically and thus containing high nitrogen. Two aerobic fermentation system each consist4s of 4 tanks ; storage tank, 1st and 2nd aeration tank and settling tank were run before and one or three weeks after equipment of artificial filament in the aeration tanks. Total solids concentration tended to increase by aerobic fermentation in all running periods. However, decreased(P<0.05) total nitrogen concentration was shown three weeks after the equipment of artificial filament. Ammonia nitrogen concentration also largely decreased(p<0.05) in both running periods of one and three weeks after equipment of artificial filaments. These results suggest that the artificial filaments may improve the removal efficiency of nitrogen in swine wastewater containing high nitrogen during aerobic fermentation.

  • PDF

식품폐수 처리 단계별 미생물 대사지문 (Metabolic Fingerprinting of Food Wastewater Treatment System)

  • 유기환;이상현;이동근
    • 한국환경보건학회지
    • /
    • 제34권4호
    • /
    • pp.327-332
    • /
    • 2008
  • To determine structure and activities of microbial communities in a food wastewater treatment system, biofilm of RABC (rotating activated Bacillus contactor) and samples of aeration tanks were analyzed. Heterotrophic bacterial concentrations were similar between biofilm and stage 1 aeration tank and decreased 2-log at stage 3 aeration tank as dissolved oxygen decreased, however portions of Bacillus groups were increased at stage 3 aeration tank. It was revealed by quantitative and qualitative analysis of metabolic fingerprinting patterns of Biolog GN2 plate that RABC represented much higher activities and a different microbial community structure compared to aeration tanks. Metabolic fingerprinting showed the carbon sources that isolated Bacillus groups could or could not use, were used similarly meaning that not only Bacillus groups but also other microbial groups would contribute to the treatment of wastewater.

Development and Field Assessment of DO Control System in an Aeration Tank for Automation of Sewage Treatment Plant

  • Jung, In-Chul;Kim, Dae-Yong;Junq, Byung-Gil
    • 한국환경과학회지
    • /
    • 제18권6호
    • /
    • pp.603-608
    • /
    • 2009
  • Activated sludge sewage treatment processes are difficult to be controlled because of their complex and nonlinear behaviour, however, the control of the dissolved oxygen level in the reactors plays an important role in the operation of the facility. For this reason, this study is designed to present a system which accurately measures DO, MLSS, pH and ORP in the aeration tank to alleviate situations above and provide the automatization of a sewage treatment plant (STP) using new DO control system. The automatic control systems must be guaranteed the accuracy. Therefore, the proposed automatic DO control system in this study could be commercial applications in the aeration tanks by means of operating cost analysis and user-friendly for operation and maintenance. We could get accurate data from the lab tank which has water quality checker because there was no vortex and air bubble during the measurement process. Improvement of confidence in the lab tank enabled effective and automatic operation of sewage treatment plants so that operation costs and manpower could be saved. If this result is put in place in every sewage treatment plant nationwide for practical purposes, it is estimated to cost 18.5 million dollars in installing the lab tank and to save 9.8 million dollars in management cost a year, except for cost saved by automation.

점감포기에 의한 바실러스 특성을 이용한 폐수의 유기물질 및 질소, 인 처리에 관한 연구 (Removal of organic Carbon, Nitrogen and Phosphorus in Wastewater based on tapered Aeration with Bacillus sp.)

  • 김판수;이상호
    • 한국산학기술학회논문지
    • /
    • 제8권4호
    • /
    • pp.861-866
    • /
    • 2007
  • 본 연구는 하 폐수 중의 유기물뿐만 아니라 질소, 인을 생물학적으로 제거하기 위하여 Bacillus sp. 미생물을 사용하였다. Bacillus sp. 미생물이 생존하기에 알맞지 않은 상황에서는 포자를 형성하고, 증식과 포자화를 반복하면서 우점화되는 특성을 발현시키기 위해 점감포기를 실시하였다. 반응기 용존산소 농도는 포기조 1단; $1.2{\sim}l.5mg/L$, 포기조 2단; $0.3{\sim}$0.5mg/L, 포기조 3단 ; 0.2mg/L이하로 유지하였다. 또한 공정내 미생물의 유실을 방지하고 미생물이 고농도 상태로 유지 가능한 부착성장의 한 공법인 RBC에 끈상 나선형 미생물 접촉재를 설치한 반응기를 이용하였다. 식종한 Bacillus sp.가 적응하는 기간에서의 유입유량은 173 L/d, 내부반송율 200%, 슬러지반송율 100%로 운전을 하였으며, 방류수질을 기준으로 단계적으로 유입유량을 증가시켰다. 정상상태에서 유입유량은 346 L/d이고, 내부반송율과 슬러지 반송율은 각각 50%로 결정하여 실험을 수행하였고, 원수는 Glucose 1,800 mg/L. $NH_4Cl\;500mg/L,\;KH_2PO_4\;5mg/L$를 혼합한 인공폐수를 제조하여 공정에 주입하였고, 그 결과 각각 미생물이 폐수에 적응하는 단계인 Period 1에서는 각 수질 분석 항목의 농도가 점차적으로 감소하는 경향을 보였으며. 정상상태라고 판단한 Period 2에서는 최종적으로 유입수에 대한 유출수의 제거율은 각각 TCODCr 94%. BOD 87%, T-N 85%, T-P 89%의 결과를 나타내었다.

  • PDF

활성슬러지공정에서 구리의 거동에 관한 연구 (A Study on the Cu2+ Behavior in Activated Sludge Process)

  • 박진도;이학성
    • 한국환경과학회지
    • /
    • 제19권9호
    • /
    • pp.1119-1127
    • /
    • 2010
  • The behavior of copper throughout the whole process of wastewater treatment plant that uses the activated sludge process to treat the wastewater of petrochemical industry that contains low concentration of copper was investigated. Total inflow rate of wastewater that flows into the aeration tank was $697\;m^3$/day with 0.369 mg/L of copper concentration, that is, total copper influx was 257.2 g/day. The ranges of copper concentrations of the influent to the aeration tank and effluent from the one were 0.315 ~ 0.398 mg/L and 0.159 ~ 0.192 mg/L, respectively. The average removal rate of copper in the aeration tank was 50.8 %. The bioconcentration factor (BCF) of copper by microbes in the aeration tank was 3,320. The accumulated removal rate of copper throughout the activated sludge process was 71.3%, showing a high removal ratio by physical and chemical reactions in addition to biosorption by microbes. The concentration of copper in the solid dehydrated by filter press ranged from 74.8 mg/kg to 77.2 mg/kg and the concentration of copper by elution test of waste was 2.690 ~ 2.920 mg/L. It was judged that the copper concentration in dehydrated solid by bioconcentration could be managed with the control of that in the influent.

하수처리장 폭기조의 용존산소농도 모니터링 대표지점 선정에 관한 연구 (A study on the determination of a representative location for monitoring the dissolved oxygen concentration in a aeration tank of sewage treatment plant)

  • 방석용;범봉수;김진한
    • 상하수도학회지
    • /
    • 제33권5호
    • /
    • pp.389-394
    • /
    • 2019
  • In order to determine the location of average concentration and distribution status of dissolved oxygen in the rectangular aeration tank of the sewage treatment plant was analyzed and the difference of dissolved oxygen concentration was remarkable at each location. Compared with the computational fluid dynamics analysis, it was found that the results were consistent with the measurement results by showing the difference of dissolved oxygen concentration between the locations. Based on the measured data, the representative location of dissolved oxygen in aeration tank was selected by using statistical analysis method and the representative location was expressed in three-dimensional coordinates(LWH : 25%, 50%, 33%) from flow direction and left wall. Also the difference between the dissolved oxygen concentration at the actual measurement location and the average concentration value of the entire aeration tank was founded, and the equations for calibrating the automatic measurement data considering the actual measurement location were calculated.

소규모 농가용 가축 뇨.오수 정화조 개선에 관한 연구 (Improvement of Septic Tank for Piggery Wastewater Treatment of Small Pig Farm)

  • 전병수;곽정훈;김태일;유용희;양창범;김형호;한정대
    • 한국축산시설환경학회지
    • /
    • 제5권3호
    • /
    • pp.175-180
    • /
    • 1999
  • This study was carried out to improve septic tank for piggery wastewater treatment of small pig farm. Septic tank were consisted of screen tank, aeration tank with two steps, settling tank, and filtering tank. Aeration tanks were filled with ALC of ø4~5cm. All operation steps were performed by timer from influent to effluent. Septic tank decreased BOD by 94.7% from 4,298.3mg/$\ell$ to 226.3mg/$\ell$ and also decreased SS by 92.4%, from 2,231.3mg/$\ell$ to 161.0mg/$\ell$, respectively.

BIO-CLOD를 이용한 고도처리공정에서의 영양염류 제거 (Nutrient Removal in an Advanced Treatment Process using BIO-CLOD)

  • 박완철;이미애;성일화
    • 한국환경보건학회지
    • /
    • 제40권4호
    • /
    • pp.322-329
    • /
    • 2014
  • Objectives: The purpose of this study was to investigate the effect of BIO-CLOD on advanced wastewater treatment for enhanced removal efficiency and meeting the stringent discharge water requirements of wastewater treatment plants. Methods: Two experimental apparatuses consisting of anaerobic, anoxic and aeration tanks were operated. One included a BIO-CLOD cultivation tank. Organic and nutrient parameters and removal efficiency were analyzed by pH, BOD, CODcr, SS, T-N and T-P. Results: The average removal efficiencies of BOD, COD and SS from the apparatus with BIO-CLOD tank installation were 95.5%, 88.6% and 92.9%, respectively, and these were higher than the results from the apparatus without BIO-CLOD. The average TP removal efficiency with BIO-CLOD tank marked 56.0%, higher than the 47.3% from the apparatus without one. BIO-CLOD showed a higher performance for TN removal at 49.6%, compared to the result without BIO-CLOD of 34.3% Conclusion: By reaction with BIO-CLOD, ammonia removal was effective in the aeration tank, as was phosphorus release in the anaerobic tank. Phosphorus luxury uptake and nitrification in aeration tank proceeded smoothly. The application of BIO-CLOD can improve the decrease of odor and settleability of activated sludge in a wastewater treatment plant, as well as increase the removal efficiency of organic and nutrient materials in water.

물 부족국가에서 활용가능한 정화조의 최적모형 개발 (Development of Optimal Septic Tank in the Countries of Water Shortages)

  • 임봉수;경해룡
    • 한국물환경학회지
    • /
    • 제31권4호
    • /
    • pp.418-427
    • /
    • 2015
  • This study was carried out to evaluate the performance of a lab-scale novel septic tank system for improving the conventional septic tank in the developing countries of water shortages. The lab-scale novel septic tank system consists of sepetic tank, aeration tank with HBC-ring, and sand filter. Optimum HRT was reguired about 1.5days to get a total COD removal efficiency of 90%, COD, BOD and SS removal efficiency was about 70%, 60%, and 85% in sepetic tank only. The structure of sepetic tank with two stages results in the high removal efficiency of organic matter. When sepetic tank, aeration tank, and sand filter were more than HRT 1.5days, 18hrs, and 12hrs, respectively, final effluent was less than 20 mg/L of BOD, 14 mg/L of SS, so that there is a high potential of its use for reusing water in flush toilet. There is no significant effect of HRT change on nutrient removal. Total nitrogen removal efficiency was about 40%, final effluent was 30~40 mg/L of TN, total phosphorus removal efficiency was about 11~25%, final effluent was 9~12 mg/L of TP. Because there is very small amounts of organic nitrogen and phosphorus in effluent, it was possible to reuse water for agricultural use.