• Title/Summary/Keyword: Advanced-pressure driven analysis

Search Result 8, Processing Time 0.018 seconds

Analysis of Macroscopic Spray Characteristics of Diesel Injectors with Three Different Needle Driving Type in Common Rail Direct Injection System (3가지 니들구동방식별 CRDi 디젤엔진용 고압 인젝터의 거시적 분무특성 비교해석)

  • Lee, Jin-Wook;Min, Kyoung-Doug
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.30 no.3
    • /
    • pp.351-358
    • /
    • 2006
  • The capability of high pressure injection with small fuel quantify at all engine operating conditions is one of the main feature in common rail fuel injection system, which is used in small and light-duty Diesel engine. The key parameter for the better atomized fuel sprays and multiple injections of this common rail fuel injection control, that can be freely selected irrespective of the engine speed and load is the mechanism controlling the needle energizing and movement in high pressure Diesel injector. In the electro-hydraulic injector, the injection nozzle is being opened and closed by movement of the injector's needle which is balanced by pressure between the nozzle seat and the needle control chamber. This study describes the macroscopic spray structure characteristics of the common rail Diesel injectors with different electric driving method i.e. the solenoid-driven and piezo-driven type. The macroscopic spray characteristics such as spray tip speed. spray tip penetration and spray cone angle were investigated by the high speed spray, which is measured by the back diffusion light illumination method with optical system for the high speed temporal photography in a constant volume chamber pressurized by nitrogen gas. As the results, the prototype piezo-driven injector system was designed and fabricated for the first time in domestic case and the effect of injector's needle response driven by different drive type was compared between the solenoid and piezo-driven injector It was found therefore. that the piezo-driven injector showed faster needle response and had better needle control capability by altering the electric input value than the solenoid-driven injector.

Numerical Analysis for Improving Passing Flow Rate Quantity abound a Radiator (라디에이터 통과풍량 확보를 위한 수치적 검토)

  • 김은필;강상훈
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.25 no.2
    • /
    • pp.304-310
    • /
    • 2001
  • This paper describes the analysis of flow field using a projection finite element method. The projection scheme with a pressure correction is presented for the analysis of an incompressible Navier-Stokes flow. The projection scheme is analyzed numerically and applied to the well-known bench marking problems such as lid driven cavity. Finally, the projection scheme is applied to a flow through the automobiles front. In the automobiles cooling system, the flow through its front is very important to a cooling performance. The results show that the flow quantity increases by locating the position of bumper to the further front position of a car. And, the improvement on the suction part below a bumper achieves the more passing flow quantity. The attachment of an air dam increases passing flow quantity causing the pressure rise to the front part and the pressure drop beneath a car.

  • PDF

An application of the A-PDA model and the water supply performance index for the temporal and spatial evaluation of the performance of emergency water supply plans via interconnections (비상시 용수 연계공급 성능의 시·공간적 평가를 위한 A-PDA 모형 및 공급성능지표의 적용)

  • Oak, SueYeun;Kim, SuRi;Jun, Hwandon
    • Journal of Korea Water Resources Association
    • /
    • v.51 no.11
    • /
    • pp.977-987
    • /
    • 2018
  • The purpose of the water distribution system is gradually changing to increase the flexibility for responding to various abnormal situations. In addition, it is essential to improve resilience through preparing emergency plans against water supply failure. The most efficient way is emergency interconnections which supply water from interconnected adjacent blocks. To operate successful interconnections, it is essential to evaluate the supply performance in spatial and temporal aspects. The spatial and temporal aspects are dominated by its interconnected pipes and interconnected reservoirs respectively. In this study, an emergency interconnection scenario where problem occurred in reservoir 1 at 0:00hr in A city, Korea. An Advanced-Pressure Driven Analysis model was used to simulate the volume and inflow volume of the interconnected reservoirs. Based on the hydraulic analysis results, a multi-dimensional evaluation of the supply performance was conducted by applying possible water supply range indicator (PWSRI) and possible water supply temporal indicator (PWSTI) which are based on fuzzy membership functions. As a result, it was possible to evaluate the supply performance on the sides of consumers in spatio-temporal aspects and to review whether established plans mitigate the damage as intended. It is expected to be used for decision making on structural and non-structural emergency plan to improve the performance of an emergency interconnection.

Friction Torque Analysis of a Hydraulic Motor-Load System using Proportional Control Valve (비례제어밸브를 이용한 유압모터 부하계의 마찰토크 해석)

  • Yu, Hwan-Shin;Park, Hyung-Bae
    • Journal of Advanced Navigation Technology
    • /
    • v.14 no.5
    • /
    • pp.760-766
    • /
    • 2010
  • In this paper, The static friction torque and viscous friction torque including hydraulic motor-load system driven by hydraulic proportional control valve analysis. The basic experimental was performed toward characteristic in pressure and flow rate in hydraulic system energy. The variable of friction torque was experiment on brake pressure variable using pneumatic brake system. The analysis of nonlinear friction and linear friction was perform ed toward friction characteristic of hydraulic system.

Study on the Improvement of Output Fluctuation from Generator Driven by Large Size-Low Speed Diesel Engine (대형저속 디젤엔진 구동 발전기의 출력변동 개선에 관한 연구)

  • 김영주;전효중;이돈출;이충기
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.16 no.5
    • /
    • pp.6-16
    • /
    • 1992
  • Since world-wide oil shock on 1970s, many large size-low speed diesel engines, instead of steam turbines, are used for the industrial electric power generating plants due to their economic advantage of low specific fuel consumption. But it is very important to control their electric power fluctuation problems for the purpose of smooth parallel operation with existing power plants. In this paper the fluctuation problem of KEPCO Nam-cheju No.1 generator driven by diesel ngine(B & W 7K 60MC, 13931x138.5RPM) is investigated with analysis of torsional vibration of which 4th harmonic component is related to its power fluctuation. The problem can be improved by modification of cylinder arrangement and flywheel position in reverse sequence, equalizing the combustion gas pressure of all cylinder and installation of torsional vibration damper enlarged 30%(Je=7287Kg.m$^{2}$) and high quality balancing of generator rotor.

  • PDF

Accelerated Monte Carlo analysis of flow-based system reliability through artificial neural network-based surrogate models

  • Yoon, Sungsik;Lee, Young-Joo;Jung, Hyung-Jo
    • Smart Structures and Systems
    • /
    • v.26 no.2
    • /
    • pp.175-184
    • /
    • 2020
  • Conventional Monte Carlo simulation-based methods for seismic risk assessment of water networks often require excessive computational time costs due to the hydraulic analysis. In this study, an Artificial Neural Network-based surrogate model was proposed to efficiently evaluate the flow-based system reliability of water distribution networks. The surrogate model was constructed with appropriate training parameters through trial-and-error procedures. Furthermore, a deep neural network with hidden layers and neurons was composed for the high-dimensional network. For network training, the input of the neural network was defined as the damage states of the k-dimensional network facilities, and the output was defined as the network system performance. To generate training data, random sampling was performed between earthquake magnitudes of 5.0 and 7.5, and hydraulic analyses were conducted to evaluate network performance. For a hydraulic simulation, EPANET-based MATLAB code was developed, and a pressure-driven analysis approach was adopted to represent an unsteady-state network. To demonstrate the constructed surrogate model, the actual water distribution network of A-city, South Korea, was adopted, and the network map was reconstructed from the geographic information system data. The surrogate model was able to predict network performance within a 3% relative error at trained epicenters in drastically reduced time. In addition, the accuracy of the surrogate model was estimated to within 3% relative error (5% for network performance lower than 0.2) at different epicenters to verify the robustness of the epicenter location. Therefore, it is concluded that ANN-based surrogate model can be utilized as an alternative model for efficient seismic risk assessment to within 5% of relative error.

The Comparative Analysis of the Internal Control According to Economic Changes in Korean Companies

  • Park, Cheol-Soo
    • Journal of Information Technology Applications and Management
    • /
    • v.21 no.3
    • /
    • pp.119-133
    • /
    • 2014
  • Prior to the 2000s, internal control had not been among the high priority issues in the management's agenda. Since then, however, it has become one of the hottest issues, and has received a significant attention as the means of improving the transparency, sustainability, and competitiveness of a company. The objectives of this paper are to examine if there has been any noticeable changes in the level of internal controls of Korean companies before and after the 2010, and to analyze the underlying drivers and issues thereto. Accounting manipulation and moral hazard were among the factors to cause the Korean financial crisis in 1997 and 2008. Since then, the capital market has had a strong pressure on Korean companies to enhance the transparency of management and accounting while the government has made the laws, requirements, and recommendations to alleviate the moral hazard problems of management and enhance the accounting transparency. Both market and government have driven companies to put more priority on the reliability of financial reporting and the compliance of applicable laws and regulations. Thereby, the market and governmental forces has led companies to enhance the level of internal controls which contribute to the reliability of financial reporting and the compliance The pressure on companies to enhance the level of internal controls may be different across industries. The capital market and government experiencing the severe financial crisis in 1997 and 2008 put even more pressure on financial companies such as banks to upgrade the reliability of financial reporting and the compliance of regulations to the global level than on non-financial companies. A survey is performed on the changes in the level of internal controls of 54 major companies consisting of 10 financial and 44 non-financial companies in Korea. The survey results show that the average level of internal controls of Korean companies has noticeably improved and that the change in the level of control environment factor is higher than that of IT control factor. The analysis on the industry differences shows that financial companies increased the level of control environment factor more than non-financial companies did while non-financial companies upgraded the level of IT control factor more than financial companies did relatively. Among internal control categories, the most improved area since the economic crisis is "Risk Assessment." The global best practices for risk management have been developed primarily in the financial industry and then spread to other industries. The general level of control practices of Korean companies has been improving significantly, but still appears below the global advanced practices.

A study on lubrication characteristics between piston ring and cylinder bore of bent-axis type piston pump for vehicle (차량용 사축식 피스톤 펌프의 피스톤 링과 실린더 보어간의 윤활특성에 관한 연구)

  • Jung, Jae-Youn;Cho, Ihn-Sung;Song, Kyu-Keun;Baek, Il-Hyun;Oh, Seok-Hyung;Jung, Seok-Hoon;Jeong, Yong-Wook
    • Tribology and Lubricants
    • /
    • v.23 no.5
    • /
    • pp.201-206
    • /
    • 2007
  • The bent-axis type piston pump which is driven by the piston rod works on the way that the piston rod drives the cylinder block, so the taper angle of the piston rod and the swivel angle between the cylinder block and the shaft are very important design factors. If the above factors cannot satisfy the conditions of optimum design, the friction loss between the cylinder bore and the piston increases, and the pump can even fail to work under conditions of severe friction and wear. Since the piston reciprocates in the cylinder bore with high velocity, and at the same time it rotates on its own axis and revolves on the center of the cylinder block, the decrease of the volume efficiency generated on account of the leakage between the cylinder bore and the piston. Therefore, to prevent this case, the piston ring is designed at the end of the piston, and the friction characteristics between the piston ring and the cylinder bore are in need of research due to its great influence on the performance of piston pump. Thus, in this paper, the elastic hydraulic oil's lubrication analyses of the film thickness, the pressure distribution, and the friction force, and so on, have been performed, and the lubrication characteristics between the piston ring and the cylinder bore are explored by the results of the numerical analysis, and it is contributed to realize the higher efficiency and the more advanced performance of the bent-axis type piston pump.