• Title/Summary/Keyword: Advanced indentation

Search Result 80, Processing Time 0.028 seconds

Studies on the Development of TiAIN/CrN Multi-layered Thin Films by Unbalanced Magnetron Sputtering Process (비대칭 스퍼터링에 의한 TiAIN/CrN 나노 다층 박막의 합성 및 특성 분석에 관한 연구)

  • Kim, Gwang-Seok;Kim, Bom-Sok;Lee, Sang-Yul
    • Journal of the Korean institute of surface engineering
    • /
    • v.38 no.6
    • /
    • pp.207-211
    • /
    • 2005
  • In this work a multi-layered nanostructured TiAIN/CrN superlattice coatings was synthesized using closed-field unbalanced magnetron sputtering method and the relationships between their superlattice period (1), micro-structure, hardness and elastic modulus were investigated. In addition, wear test at $500^{\circ}C$ and oxidation resistance test at $900^{\circ}C$ were performed to investigate high temperature properties of these thin films. The coatings were characterized in terms of microstructure and mechanical properties by transmission electron microscopy (TEM) and nano-indentation test. Results from TEM analysis showed that superlattice periods was inversely proportional to the jig rotation speed. The maximum hardness and elastic modulus of 37 GPa and 375 GPa were observed at superalttice period of 6.1 nm and 4.4 nm, respectively. An higher value of microhardness from TiAIN/CrN thin films than either TiAIN (30 GPa) or CrN (26 GPa) was noted while the elastic modulus was approximately an average of TiAIN and CrN films. These enhancement effects in superlattice films could be attributed to the resistance to dislocation glide across interface between the CrN and TiAIN layers. Much improved plastic deformation resistance ($H^3/E^2$) of 0.36 from TiAIN/CrN coatings was observed, compared with 0.15 and 0.16 from TiAIN and CrN, respectively. Also the wear resistance at $500^{\circ}C$ was largely increased than those of single TiAIN and CrN coatings and TiAIN/CrN coatings showed much reduced weight gain after exposure at $900^{\circ}C$ for 20 hours.

A Study on the Diagnostic Significance of Hepatoscintigram with Colloidal Gold in Parenchymal Liver Disease (간실질(肝實質) 병변(病變)에 대(對)한 간주사(肝走査) (Hepatoscintigram with $^{198}Au$ colloid)의 진단적(診斷的) 가치에 대한 고찰)

  • Shin, Dong-Ho;Lee, Min-Ho;Kim, Mok-Hyun
    • The Korean Journal of Nuclear Medicine
    • /
    • v.16 no.1
    • /
    • pp.63-72
    • /
    • 1982
  • Hepatoscintigram has been a useful diagnostic method for the liver diseases since 1953, but reasonable diagnostic criteria for parenchymal liver diseases are not yet accurately established. For the purpose of searching for more advanced diagnostic criteria for various types of live disease by the liver scan, a retrospective study was made of 272 cases who underwent both hepatoscintigram with 198 Au colloid and liver biopsy in Hanynag University Hospital from Jan., 1978 to Dec., 1981. The results were as follows: 1. Fuzzy margin (irregular indentation of the liver margin) in the hepatoscintigram was noted in 226 cases (97.79%). 2. Of 35 cases with fuzzy margin only, 28 cases (80%) revealed mild parenchymal liver disease, such as acute hepatitis or chronic persistent hepatitis by the liver biopsy. 3. Mottling change (209 cases) was always accompanied by fuzzy margin except only one case, and 31 cases (86.1%) of fuzzy and mottling cases (36 cases) showed mild parenchymal liver disease. 4. Configuration change (193 cases) was usually accompanied with other changes and espicially 104 cases had configuration change with fuzzy and mottling changes. 73 cases (88.44%) of 86 cases with severe configuration change revealed advanced parenchymal liver disease on biopsy. If liver scan showed mild configuration change, we could not decide the type of liver disease only liver scan, and so further studies are needed. 5. Splenic uptake was noted in 34 cases (40.48%) of 84 cases with advanced parenchymal liver disease, and the degree of splenic uptake was for the most part morderate or severe; whereas splenic uptake was noted in 18 cases (16.51%) of the mild parenchymal liver disease (109 cases), and the degree of splenic uptake was largely mild.

  • PDF

Microstructure and Tribological Properties of Ti-Si-C-N Nanocomposite Coatings Prepared by Filtered Vacuum Arc Cathode Deposition

  • Elangovan, T.;Kim, Do-Geun;Lee, Seung-Hun;Kim, Jong-Kuk
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2011.02a
    • /
    • pp.54-54
    • /
    • 2011
  • The demand for low-friction, wear and corrosion resistant components, which operate under severe conditions, has directed attentions to advanced surface engineering technologies. The Filtered Vacuum Arc Cathode Deposition (FVACD) process has demonstrated atomically smooth surface at relatively high deposition rates over large surface areas. Preparation of Ti-Si-C-N nanocomposite coatings on (100) Si and stainless steel substrates with tetramethylsilane (TMS) gas pressures to optimize the film preparation conditions. Ti-S-C-N coatings were characterized using X-ray diffraction, X-ray photoelectron spectroscopy, transmission electron microscopy, nanoindentation, Rockwell C indentation and ball-on-disk wear tests. The XRD results have confirmed phase formation information of TiSiCN coatings, which shows mixing of TiN and TiC structure, corresponding to (111), (200) and (220) planes of TiCN. The chemical composition of the film was investigated by XPS core level spectra. The binding energy of the elements present in the films was estimated using XPS measurements and it shows present of elemental information corresponding to Ti2p, N1s, Si 2p and C1. Film hardness and elastic modulus were measured with a nano-indenter, and film hardness reached 40 GPa. Tribological behaviors of the films were evaluated using a ball-on-disk tribometer, and the films demonstrated properties of low-friction and good wear resistance.

  • PDF

Characterization of Thin Film Materials by Nanoindentation and Scanning Probe Microscopy (나노인덴테이션과 주사탐침현미경을 이용한 박막 재료의 특성평가)

  • Kim, Bong-seob;Yun, Jon-do;Kim, Jong-kuk
    • Korean Journal of Materials Research
    • /
    • v.13 no.9
    • /
    • pp.606-612
    • /
    • 2003
  • Surface and mechanical properties of thin films with submicron thickness was characterized by nanoindentation with Berkovich and Vickers tips, and scanning probe microscopy. Nanoindention was made in a depth range of 15 to 200 nm from the surface by applying tiny force in a range from 150 to $9,000 \mu$N. Stiffness, contact area, hardness, and elastic modulus were determined from the force-displacement curve obtained. Reliability was first tested by using fused quartz, a standard sample. Elastic modulus and hardness values of fused quartz measured were the same as those reported in the literature within two percent of error. Mechanical properties of ITO thin film were characterized in a depth range of 15∼200nm. As indentation depth increased, elastic modulus and hardness decreased by substrate effect. Ion beam deposited DLC thin films were indented in a depth range of 40∼50 nm. The results showed that the DLC thin film using benzene and bias voltage 0∼-50 V has elastic modulus and hardness value of 132 and 18 GPa respectively. Pure DLC thin films showed roughnesses lower than 0.25 nm, but silicon-added DLC thin films showed much higher roughness values, and the wavy surface morphology.

Wear Properties of Silicon Nitride Nano-Ceramics (나노 질화규소 세라믹스의 내마모 특성)

  • Kim, Jae-Hee;Kumar B, Venkata Manoj;Kim, Won-Sik;Hong, Seong-Hyeon
    • Journal of the Korean Ceramic Society
    • /
    • v.46 no.5
    • /
    • pp.505-509
    • /
    • 2009
  • In this study, bulk nano-crystalline $Si_3N_4$ ceramics were fabricated by spark plasma sintering (SPS) and their mechanical properties, in particular wear, were investigated. A wide range of grain sizes, from 80 nm and 250 nm were obtained by varying sintering conditions ($1550^{\circ}C$-5 min to $1650^{\circ}C$-20 min). The elastic modulus of obtained ceramics was ${\sim}250$ GPa and hardness was in the range of $13{\sim}14$ GPa. The indentation fracture toughness increased from $2.58MPa{\cdot}m^{1/2}$ to $3.24MPa{\cdot}m^{1/2}$ with increasing sintering temperature possibly due to the elongated grains. Sliding wear tests revealed at least an order magnitude improvement in wear resistance with grain refinement. Microstructure analysis indicated that nano-$Si_3N_4$ specimens worn mainly through delamination and microcracking, while that of coarser specimens revealed severe wear with grain debonding and fracture.

Effects of Sr Additions on the Interfacial Reaction Layers Formed between Liquid Al-Si-Cu Alloy and Cast Iron

  • Kyoung-Min Min;Je-Sik Shin;Jeong-Min Kim
    • Korean Journal of Materials Research
    • /
    • v.33 no.9
    • /
    • pp.353-359
    • /
    • 2023
  • This study investigated the growth behavior and characteristics of compounds formed at the interface between a liquid Al-Si-Cu alloy and solid cast iron. Through microstructural analyses, it was observed that various AlFe and AlFeSi phases are formed at the interface, and the relative proportion of each phase changes when small amounts of strontium are added to the Al alloy. The results of the microstructural analysis indicate that the primary phases of the interfacial compounds in the Al-Si-Cu base alloy are Al8Fe2Si and Al4.5FeSi. However, in the Sr-added alloys, significant amounts of binary AlFe intermetallic compounds such as Al5Fe2 and Al13Fe4 formed, in addition to the AlFeSi phases. The inclusion of Sr has a slight diminishing effect on the rate at which the interfacial compounds layer thickens during the time the liquid Al alloy is in contact with the cast iron. The study also discusses the nano-indentation hardness and micro-hardness of the interfacial phases.

In-vitro Hertzian Fatigue Behavior of Zirconia/Alumina Composites (지르코니아/알루미나 복합체의 In-vitro Hertzian 피로거동)

  • Lee, Deuk-Yong;Park, Il-Seok;Kim, Dae-Joon;Lee, Se-Jong
    • Journal of the Korean Ceramic Society
    • /
    • v.41 no.1
    • /
    • pp.69-75
    • /
    • 2004
  • The degree of the indentation damage and strength degradation for 3Y-TZP ceramics and (Y,Nb)-TZP/$Al_2O_3$ dental implant composites was investigated under the Hertzian cyclic fatigue. Fatigue tests were conducted at contact loads of 500 to 3000 N and up to $10^6$ cycles in exact in vitro environments. At 500 N, no strength degradation and crack generation was observed up to $5{\times}10^5$ contact cycles. Fatigue properties of 3Y-TZP ceramics was superior to (Y,Nb)-TZP/ㅍ composites due to stress relief caused by the phase transformation from tettagonal to monoclinic phase. As contact load increased, the drastic reduction in strength was found when the damage transition from ring to radial crack occurred. The extent of strength degradation was more pronounced in vitro environments probably due to chemical corrosion of artificial saliva through cracks introduced during large numbers of contacts.

Thermal Stability, Mechanical Properties and Magnetic Properties of Fe-based Amorphous Ribbons with the Addition of Mo and Nb

  • Han, Bo-Kyeong;Jo, Hye-In;Lee, Jin Kyu;Kim, Ki Buem;Yim, Haein
    • Journal of Magnetics
    • /
    • v.18 no.4
    • /
    • pp.395-399
    • /
    • 2013
  • The metallic glass ribbons of $[(Fe_xCo_{1-x})_{0.75}B_{0.2}Si_{0.05}]_{96}Mo_4$ (x = 0, 0.3, 0.6, 0.9 at.%) and $[(Fe_xCo_{1-x})_{0.75}B_{0.2}Si_{0.05}]_{96}Nb_4$ (x = 0, 0.3, 0.6, 0.9 at.%) were obtained by melt spinning with 25-30 ${\mu}m$ thickness. The thermal stability, mechanical properties and magnetic properties of Fe-Co-B-Si based systems were investigated. The values of thermal stability were measured using differential scanning calorimetry (DSC), including glass transition temperature ($T_g$), crystallization temperature ($T_x$) and supercooled liquid region (${\Delta}T_x=T_x-T_g$). These amorphous ribbons were identified as fully amorphous, using X-ray diffraction (XRD). The mechanical properties of Febased samples were measured by nano-indentation. Magnetic properties of the amorphous ribbons were measured by a vibrating sample magnetometer (VSM). The amorphous ribbons of $[(Fe_xCo_{1-x})_{0.75}B_{0.2}Si_{0.05}]_{96}Mo_4$ (x = 0, 0.3, 0.6, 0.9 at.%) and $[(Fe_xCo_{1-x})_{0.75}B_{0.2}Si_{0.05}]_{96}Nb_4$ (x = 0, 0.3, 0.6, 0.9 at.%) exhibited soft magnetic properties with low coercive force ($H_c$) and high saturation magnetization (Ms).

A Case of Complete Remission to Advanced Esophageal Cancer by a Palliative Chemotherapy (고식적 항암화학요법으로 완치가 된 진행성 식도암 환자 1예)

  • Dae Hyun Tak;Hee Seok Moon;Hyun Yong Jeong;Jae Kyu Sung;Sun Hyung Kang
    • Journal of Digestive Cancer Research
    • /
    • v.2 no.2
    • /
    • pp.64-67
    • /
    • 2014
  • Esophageal cancer has a poor prognosis, because the progression rate is faster compared to that of other cancers, Up to 30-40% of cases are inoperable at diagnosis, and most cases occur in the elderly. By this time, surgery has been regarded as the treatment of choice in patients suffering esophageal cancer and recent improvements in surgical techniques and perioperative management have significantly increased the resection rate and reduced the operative mortality. And Although the combination of chemotherapy and radiation therapy has been reported to be an effective treatment for esophageal cancer, most cases show only partial remission. Moreover, radiation therapy alone or chemotherapy alone has limited efficacy. We report a rare case of an 80-year-old man who presented with a chief complaint of dysphasia and was diagnosed with advanced esophageal cancer, with a review of the literature. Considering his advanced age, generally poor performance status, and the risk of fistula development after radiation therapy due to indentation of esophageal cancer into the main bronchus, palliative, rather than therapeutic, chemotherapy was performed, and complete remission was obtained.

  • PDF

Effect of Microstructure on the Environmentally Induced Cracking Behavior of Al-Zn-Mg-Cu-Zr Aluminum Alloy

  • Ghosh, Rahul;Venugopal, A.;Pradeep, PI;krishna, L. Rama;Narayanan, P. Ramesh;Pant, Bhanu;Cherian, Roy M
    • Corrosion Science and Technology
    • /
    • v.17 no.3
    • /
    • pp.101-108
    • /
    • 2018
  • AA7010 is an Al-Zn-Mg-Cu alloy containing Zr, developed as an alternate to traditional AA7075 alloy owing to their high strength combined with better fracture toughness. It is necessary to improve the corrosion resistance and surface properties of the alloy by incorporating plasma electrolytic oxidation (PEO) method. AA7010-T7452 aluminum alloy has been processed through the forging route with multi-stage working operations, and was coated with $10{\mu}m$ thick $Al_2O_3$ ceramic aluminina coating using the plasma electrolytic oxidation (PEO) method. The corrosion, stress corrosion cracking (SCC) and nano-mechanical behaviours were examined by means of potentiodynamic polarization, slow strain rate test (SSRT) and nano-indentation tests. The results indicated that the additional thermomechanical treatment during the forging process caused a fully recrystallized microstructure, which lead to the poor environmental cracking resistance of the alloy in 3.5% NaCl solution, despite the overaging treatment. Although the fabricated PEO coating improved general corrosion resistance, the brittle nature of the coating did not provide any improvement in SCC resistance of the alloy. However, the hardness and elastic modulus of the coating were significantly higher than the base alloy.