• Title/Summary/Keyword: Advanced Spent Fuel Conditioning process Facility

Search Result 21, Processing Time 0.026 seconds

HOT CELL RENOVATION IN THE SPENT FUEL CONDITIONING PROCESS FACILITY AT THE KOREA ATOMIC ENERGY RESEARCH INSTITUTE

  • YU, SEUNG NAM;LEE, JONG KWANG;PARK, BYUNG SUK;CHO, ILJE;KIM, KIHO
    • Nuclear Engineering and Technology
    • /
    • v.47 no.6
    • /
    • pp.776-790
    • /
    • 2015
  • Background: The advanced spent fuel conditioning process facility (ACPF) of the irradiated materials examination facility (IMEF) at the Korea Atomic Energy Research Institute (KAERI) has been renovated to implement a lab scale electrolytic reduction process for pyroprocessing. The interior and exterior structures of the ACPF hot cell have been modified under the current renovation project for the experimentation of the electrolytic reduction process using spent nuclear fuel. The most important aspect of this renovation was the installation of the argon compartment within the hot cell. Method: For the design and system implementation of the argon compartment system, a full-scale mock-up test and a three-dimensional (3D) simulation test were conducted in advance. The remodeling and repairing of the process cell (M8a), the maintenance cell (M8b), the isolation room, and their utilities were also planned through this simulation to accommodate the designed argon compartment system. Results and conclusion: Based on the considered refurbishment workflow, previous equipment in the M8 cell, including vessels and pipes, were removed and disposed of successfully after a zoning smear survey and decontamination, and new equipment with advanced functions and specifications were installed in the hot cell. Finally, the operating area and isolation room were also refurbished to meet the requirements of the improved hot cell facility.

DESIGN AND CONSTRUCTION OF AN ADVANCED SPENT FUEL CONDITIONING PROCESS FACILITY (ACPF)

  • You, Gil-Sung;Choung, Won-Myung;Ku, Jeong-Hoe;Cho, Il-Je;Kook, Dong-Hak;Kwon, Kie-Chan;Lee, Eun-Pyo;Lee, Won-Kyung
    • Nuclear Engineering and Technology
    • /
    • v.41 no.6
    • /
    • pp.859-866
    • /
    • 2009
  • KAERI has worked on the development of an advanced spent fuel conditioning process (ACP) since 1997. A hot cell facility, termed the ACPF, has also been developed. The ACPF consists of two air-sealed hot cells. The results of a safety analysis as part of the license procurement process stipulated by the Korean Government showed that the facility was designed safely. After its construction, an integrated performance test was performed. The results of this test confirmed that the facility satisfies the design requirements.

Development of transportation and storage device for spent nuclear fuel capsules (핫셀에서 사용후핵연료봉 장전 Capsule의 이송 및 저장장치 개발)

  • Hong D.H.;Jung J.H.;Kim K.H.;Park B.S.
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2006.05a
    • /
    • pp.369-370
    • /
    • 2006
  • During demonstrations of a process conditioning spent nuclear fuels, it is necessary to transport and handle Spent fuel road cuts from Post Irradiation Examination facility to Slitting device in The hot cell. the spent fuel pellets which are highly radioactive materials are separated with its clad and are fed into the next conditioning process. For this, a spent fuel rod, 3.5 m long, is cut by 25 cm long which is suitable length for the decladding process. These rod-cuts are packed into the capsule and are moved to the ACPF(Advanced spent nuclear fuel Conditioning Process Facility). In the ACPF, Once the capsule is unloaded in the ACPF, Capsule is taken out one-by-one and installed on the decladding device. In these processes, the crushed spent fuel pellet can be scattered inside the facilities and thus it contaminate the hot cell. In this paper, we developed the specially designed transportation and storage device for spent nuclear fuel capsules.

  • PDF

Development of Transportation Capsule for Spent Nuclear Fuel Rod Cuts (사용후핵연료봉 이송 Capsule의 개발)

  • Hong D.H.;Jin J.H.;Jung J.H.;Kim K.H.;Yoon J.S.
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2005.10a
    • /
    • pp.1055-1058
    • /
    • 2005
  • In the ACPF(Advanced spent nuclear fuel Conditioning Process Facility), the spent fuel pellets which are highly radioactive materials are separated with its clad and are fed into the next conditioning process. For this, at the other facility called PIEF(Post Irradiation Examination Facility) a spent fuel rod, 3.5 m long, is cut by 25 cm long which is suitable length fur the decladding process. These rod-cuts are packed into the capsule and are moved to the ACPF. Once the capsule is unloaded in the ACPF, the rod-cut is taken out one-by-one from the capsule and installed on the decladding device. In these processes, the crushed spent fuel pellet can be scattered inside the facilities and thus it contaminate the hot cell. In this paper, we developed the specially designed capsule which prevents the pellets scattering and remarkably reduces the leading and unloading time of the rod-cuts.

  • PDF

Structural Analysis of Advanced Spent Fuel Conditioning Process Facility (차세대관리 종합공정 실증시설의 구조해석)

  • 구정회;정원명;조일제;국동학;유길성
    • Proceedings of the Korean Radioactive Waste Society Conference
    • /
    • 2003.11a
    • /
    • pp.411-420
    • /
    • 2003
  • An advanced spent fuel conditioning process (ACP) is developing for the safe and effective management of spent fuels which arising from the domestic nuclear power plants. And its demonstration facility is under design. This facility will be prepared by modifying IMEF's reserve hot cell facility which reserved for future usage by considering the characteristics of ACP. This study presents a basic structural architecture design and analysis results of ACP hot cell including modification of the IMEF. The results of this study will be used for the detail design of ACP demonstration facility, and utilized as basic data for the licensing of the ACP facility.

  • PDF

SHIELDING PERFORMANCE OF A NEWLY DESIGNED TRANSPORT CASK IN THE ADVANCED CONDITIONING SPENT FUEL PYROPROCESS FACILITIY

  • Park, Chang-Je;Jeong, Chang-Joon;Min, Deok-Ki;Kang, Hee-Young;Choi, Woo-Seok;Lee, Joo-Chan;Bang, Gyeoung-Sik;Seo, Ki-Seog
    • Nuclear Engineering and Technology
    • /
    • v.40 no.4
    • /
    • pp.319-326
    • /
    • 2008
  • To transport process wastes efficiently from the Advanced Spent Fuel Conditioning Pyro-process Facility (ACPF) at the Korea Atomic Energy Research Institute (KAERI), a new hot cell cask has been designed based on an existing hot cell padirac transport cask, with not only a neutron absorber for improved shielding capability, but also a docking facility for an easy docking system. In the new hot cell cask, two kinds of materials have been considered as shielding materials, polyethylene and resin. To verify the transport compatibility of the waste and spent fuel for the ACPF, neutron and photon shielding calculations were performed using the MCNPX code. The source term was evaluated by the ORIGEN-ARP code system based on spent PWR fuel. From the calculation, it was found that the maximum surface dose rates of the hot cell cask with the two candidates were estimated within the limit (2 mSv/hr).

The MUF of a Pilot-Scaled ACP Facility and Its Sensitivity

  • W. I. Ko;D. Y. Song;Lee, S. Y.;Kim, H. D.;Park, S. W.
    • Proceedings of the Korean Radioactive Waste Society Conference
    • /
    • 2003.11a
    • /
    • pp.401-405
    • /
    • 2003
  • The Advanced Spent Fuel Conditioning Process (ACP) have been developed at the Korea Atomic Energy Research Institute (KAERI) as an alternative for the effective conditioning of spent fuel far long-term storage or/and eventual disposal. This paper addresses the safeguardability of a pilot-scaled ACP facility and its sensitivity analysis. For this, a conceptual process and its material flow are analyzed using experiences from conventional fuel cycles, and measurement methods and their uncertainties are assumed for calculating MUF (Material Uncounted For) standards deviation (SD), We concluded from the preliminary analysis of the MUF SD that the pilot-scaled ACP facility with capacity of 30 MTHM/year can meet the International Atomic Energy Agency (IAEA) safeguards goals.

  • PDF

DEVELOPMENT OF HOT CELL FACILITIES FOR DEMONSTRATION OF ACP

  • You, Gil-Sung;Choung, Won-Myung;Ku, Jeong-Hoe;Cho, Il-Je;Kook, Dong-Hak;Park, Seong-Won
    • Proceedings of the Korean Radioactive Waste Society Conference
    • /
    • 2004.02a
    • /
    • pp.191-204
    • /
    • 2004
  • The research and development of effective management technologies of the spent fuels discharged from power reactors are an important and essential task of KAERI. In resent several years KAERI has focused on a project named "development and demonstration of the Advanced spent fuel Conditioning Process (ACP) in a laboratory scale." The Facility for ACP demonstration consists of two Hot Cells and auxiliary facilities. It is now in the final design stage and will be constructed in 2004. After construction of the facility the ACP equipments will be installed in Hot Cells. The ACP will be demonstrated by some simulated spent fuels first and then by spent fuels.

  • PDF