• Title/Summary/Keyword: Advanced Diverse Protection System

Search Result 8, Processing Time 0.021 seconds

FAULT-TOLERANT DESIGN FOR ADVANCED DIVERSE PROTECTION SYSTEM

  • Oh, Yang Gyun;Jeong, Kin Kwon;Lee, Chang Jae;Lee, Yoon Hee;Baek, Seung Min;Lee, Sang Jeong
    • Nuclear Engineering and Technology
    • /
    • v.45 no.6
    • /
    • pp.795-802
    • /
    • 2013
  • For the improvement of APR1400 Diverse Protection System (DPS) design, the Advanced DPS (ADPS) has recently been developed to enhance the fault tolerance capability of the system. Major fault masking features of the ADPS compared with the APR1400 DPS are the changes to the channel configuration and reactor trip actuation equipment. To minimize the fault occurrences within the ADPS, and to mitigate the consequences of common-cause failures (CCF) within the safety I&C systems, several fault avoidance design features have been applied in the ADPS. The fault avoidance design features include the changes to the system software classification, communication methods, equipment platform, MMI equipment, etc. In addition, the fault detection, location, containment, and recovery processes have been incorporated in the ADPS design. Therefore, it is expected that the ADPS can provide an enhanced fault tolerance capability against the possible faults within the system and its input/output equipment, and the CCF of safety systems.

The effect of temperature and relative humidity on concrete slab specimens with impressed current cathodic protection system

  • Jeong, Jin-A;Jin, Chung-Kuk
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.37 no.3
    • /
    • pp.260-265
    • /
    • 2013
  • Impressed current cathodic protection (ICCP) system is one of the most promising corrosion protection methods. The Effect of ICCP system can be changed at diverse conditions. Particularly, temperature and relative humidity plays a crucial role in CP (Cathodic Protection) effect. Thus, in this study, the influence of temperature and relative humidity on concrete specimens was investigated. Specimens were concrete slab type with a base of $400mm{\times}400mm$ and height of 70mm. To enhance the effect of CP system, seawater was used as an electrolyte. Used anode for ICCP system was mixed metal oxide (MMO) titanium. Test factors were natural potential, CP potential, CP current, and 4-hour depolarization potential. From this study, it could be confirm that CP potential and current were highly influenced by temperature and relative humidity.

A Study on the Fire Safety of High-rise Apartments Based on Fire Door Switch and Automatic Fire Extinguishing System

  • Zhang, ZeChen;Kong, Ha-Sung
    • International Journal of Advanced Culture Technology
    • /
    • v.9 no.4
    • /
    • pp.424-430
    • /
    • 2021
  • The purpose of this study is to analyse the characteristics and spreading laws of parameters such as fire smoke, concentration of CO, visibility, and temperature at fire scene in high-rise residential buildings under the different conditions of fire doors and automatic fire extinguishing systems. Using Pyrosim to simulate diverse fire scenes in a high-rise apartment with corridors, to analyze the changes in those parameters. The results show that when a fire occurs, closing the fire-fighting corridor will increase the smoke temperature and concentration of CO in the stairwell, and reduce the height and visibility of the smoke layer; the automatic fire extinguishing system effectively suppresses the increase in the temperature of the fire smoke and the sedimentation of the smoke layer. Reasonable setting and operation of the automatic fire extinguishing system could effectively inhibit the spread of fire. Although closing fire corridor can slow down the direct upward spread of smoke through the corridor, it will force the fire smoke into the stairwell, which will seriously affect evacuation through the stairs. Therefore, in order to reduce risks, it is forbidden to close the fire doors of the firefighting corridor and stacking combustible materials in the corridor, Also, intensifying inspections and ensuring the normal operation of the automatic fire extinguishing system are indispensable. Based on the research results, the significance of installing fire-fighting facilities in the construction of high-rise apartments was discussed and proved.

A Study on Biomass Utilization Strategies of Hokkaido Prefecture in Japan (일본 북해도지역 바이오매스 이용에 관한 사례 연구)

  • Yook, Hye-Young;Lee, Myung-Gyu
    • Journal of the Korea Organic Resources Recycling Association
    • /
    • v.17 no.2
    • /
    • pp.37-50
    • /
    • 2009
  • This study was carried out to investigate the integrated biomass strategies for utilization and application characteristics in Hokkaido prefecture, japan. From the results, to achieve a successful operation of biomass recycling facilities, it previously needs the effective byproduct supplying construction system for field demander as well as the advanced environmental technology introduction. Especially, the value-promotion recycling technology were requested as follows; (1) production of functional solid composting for protection soil acidification, (2) the addition of soil microorganism to the production of liquid fermentation fertilizer, (3) construction of diverse energy supply system, (4) mixed organic material fermentation process concerning on heavy metal concentration, (5) introduction of incentive garbage collection system for contaminants prevention.

Study of the Introduction on the Aviation Safety Data Protection System (항공안전데이터 보호제도 도입 방안 연구)

  • Kim, Eun-jung
    • The Korean Journal of Air & Space Law and Policy
    • /
    • v.33 no.1
    • /
    • pp.81-120
    • /
    • 2018
  • To promote the aviation safety reporting system that is operated to enhance aviation safety and to utilize related information, it should first be preceded by standards for non-punishment and data protection. It is because the purpose of collection and analysis of aviation safety related data through the aviation safety reporting system is to prevent recurrence of accidents by investigating their causes through collection and analysis of diverse types of information related to aviation safety. Both mandatory and voluntary reporting systems are in operation for aviation safety under the current Aviation Safety Act. It is said that they were introduced to survey causes for accidents and to prevent recurrences. In fact, however, it is hard to expect active implementation of the reporting system for aviation safety unless the reporters are firstly exempted from punishment. Therefore, the system should be improved so that it can satisfy its purpose and the purposes of data collection concerning aviation safety through examination of the purposes of the reporting system. One of the matters that needs to be considered to promote the reporting system should be the scope of aviation safety hindrances presupposed under the current institution. The voluntary aviation safety reporting system differs from the systems of ICAO or the key advanced countries, including the USA and the UK as it limits the target accidents subject to reporting to minor aviation safety hindrances only. That being said, improvements should be made by requiring mandatory reporting of aviation safety hindrances based on their severity while recognizing a greater variety of aviation safety concerns like international standards. Safety actions and sharing of information based on collection and analysis of diverse data related to aviation safety will greatly contribute to enhance aviation safety as the purposes of the reporting system are to explore causes for accidents and to prevent their recurrences. What is most important in this regard is strict data protection and non-punishment principles; compliance with them should be secured. We can hardly expect the successful operation of the system unless the reporter is exempted from punishment and the relevant data is protected as promotion of voluntary reporting is an essential factor for enhancing the safety culture. Otherwise, the current system may induce hiding of relevant facts or data to evade punishment. It is true that the regulation for enhancing safety tends to have limitations or blind spots; nevertheless, it should still be enforced strictly and completely. Technological progresses and mistakes of operators appear in different forms based on individual cases. The consequential damages may amount to a truly severe level. Therefore, we have studied and suggested to the methods of activiation and amendments on the aviation safety reporting system, which is referred for one of the proactive safety management systems. The proposed improvement of the reporting system and introduction of non-punishment for collection of aviation safety data for deploying a preemptive prevention system would serve as the backbone for enhancing aviation safety in Korea.

Brief history of Korean national forest inventory and academic usage

  • Park, Byung Bae;Han, Si Ho;Rahman, Afroja;Choi, Byeong Am;Im, Young Suk;Bang, Hong Seok;So, Soon Jin;Koo, Kyung Mo;Park, Dae Yeon;Kim, Se Bin;Shin, Man Yong
    • Korean Journal of Agricultural Science
    • /
    • v.43 no.3
    • /
    • pp.299-319
    • /
    • 2016
  • The National Forest Inventory (NFI) is important for providing fundamental data for basic forest planning and the establishment of forest policies for the purpose of implementing sustainable forest management. The purpose of this study is to present the development of Korea's NFI including legal basis, sampling design, and measured variables and to review the usage of NFI data. The survey methods and forestry statistics among the Unites States, Canada, Japan, China, and European countries were briefly compared. Total 140 publications utilizing NFI data between 2008 and 2015 were categorized with 15 subjects. Korea has conducted the NFI 6 times since 1971, but only the $6^{th}$ NFI is comparable with the fifth, the previous NFI, because the permanent sampling plots have been shared between the periods. The Korean Forestry Statistics contains only half as many variables as that of advanced countries in Forestry. More researches were needed to improve consistent measurement of diverse variables through implementation of advanced technologies. Additional data for Forest Health Monitoring since the NFI $6^{th}$ must be under quality control which will be an essential part of the inventories for providing the chronological change of forest health.

농식품안전 정책방향

  • Jo, Jang-Yong
    • 한국환경농학회:학술대회논문집
    • /
    • 2009.07a
    • /
    • pp.3-18
    • /
    • 2009
  • It is difficult for consumers to satisfy high safety request with post-management method such as inspection and surveillance, as various changes in-and-out of the country associated with food safety. In terms of food safety problems related to foods, it is crucial to recognize public health and consumer protection and construct pre-preventive Food Control System. A joint committee, FAO/WHO made the following consultations to the National Food Safety System. ${\circ}$ Approach entirely from farm to table ${\circ}$ Get ready for Risk Analysis System ${\circ}$ Secure transparency ${\circ}$ Establish the optimal policy by evaluating the effect of regulation When it comes to summarizing the consultation, it would be accumulated as two key words; "Efficiency" and "Credibility". Whereas the problem of efficiency focuses on precaution rather than post-management, it requires policy option to maximize consumer's benefit by evaluating the cost for the Food Safety Management and its benefit. Also, analyzing risk's character and amount, demanding an optimal means, and introducing scientific analysis system put much value on the stakeholder's communications are procedure's security which can satisfy both "Efficiency" and "Credibility" simultaneously. Especially, it is emphasized here that Risk Assessment need to be separated from Risk Management. This action is a valid means of credibility security throughout improving transparency. A number of nations and organizations have reformed the method of food management passing through reflection and examination of the prior National Food Safety Management since BSE occurred in Britain, 1996. FSA; Food Standard Agency, AFFSA, EFSA, BfR, and FSC are Risk Assessment Organization functionally separated from Risk Management Organization, JECFA, JMCFA, JMPR, JEMRA in Codex charge Risk Assessment internationally. In case of advanced countries excluding several those such as The U.S. and so forth, though these Risk Assessment Organizations are either separated functionally within Risk Management Organization or operated as apart organ, common factors are in which it has independence as Science Base. While securing independence of Risk Assessment Function, it is a tendency Risk Management should be functionally unified into efficiency as well. Though Germany constructs integral Risk Management System of diverse ways according to social and political conditions of each country such as GFOCP, DVFA, SNFA, CFIS and AQIS, there is a key word in the center, "Securing efficiency of Food Safety Management". However our nation has a representative plural;diversified system with The U.S., we took a step forward for unification as empowering policy's generalization;adjustment and Risk Assessment Function by means of enacting the "Food Safety Fundamental Law" in 2008 and establishing the "Food Safety Policy Commission" with private and governmental sectors in the Prime Minister's office. Even though the unification of Risk Management hereby increased, there is the lack of strengthening function of Risk Assessment and securing independence. It needs to be required for the professional committee in Food Safety Policy Commission to develop as a exclusive office of Risk Assessment by separating from a policy decision. Administrative Branches should reinforce feeble functions such as fundamental investigation;research for carrying out Risk Assessment with securing efficiency throughout reassessment of prior Risk Management Means.

  • PDF