• Title/Summary/Keyword: Advanced Dentistry

Search Result 1,055, Processing Time 0.024 seconds

Cumulative survival rate and associated risk factors of Implantium implants: A 10-year retrospective clinical study

  • Park, Jin-Hong;Kim, Young-Soo;Ryu, Jae-Jun;Shin, Sang-Wan;Lee, Jeong-Yol
    • The Journal of Advanced Prosthodontics
    • /
    • v.9 no.3
    • /
    • pp.195-199
    • /
    • 2017
  • PURPOSE. The objective of this study was to determine the cumulative survival rate (CSR) and associated risk factors of Implantium implants by retrospective clinical study. MATERIALS AND METHODS. Patients who received Implantium implants (Dentium Co., Seoul, Korea) at Korea University Guro Hospital from 2004 to 2011 were included. The period between the first surgery and the last hospital visit until December 2015 was set as the observation period for this study. Clinical and radiographic data were collected from patient records, including all complications observed during the follow-up period. Kaplan-Meier analysis was performed to examine CSR. Multiple Cox proportional hazard model was employed to assess the associations between potential risk factors and CSR. RESULTS. A total of 370 implants were placed in 121 patients (mean age, 56.1 years; range, 19 to 75 years). Of the 370 implants, 13 failed, including 7 implants that were lost before loading. The 10-year cumulative survival rate of implants was 94.8%. The multiple Cox proportional hazard model revealed that significant risk factor of implant failure were smoking and maxillary implant (P<.05). CONCLUSION. The 10-year CSR of Implantium implants was 94.8%. Risk factors of implant failure were smoking and maxillary implant.

A Study on IoT cloud type middleware platform structure for medical light module control (의료용 Light 모듈 제어를 위한 IoT 클라우드형 미들웨어 플랫폼 구조 연구)

  • Lee, Kack-Hee;Lee, Min-Woo;Cha, Jae-Sang
    • The Journal of the Convergence on Culture Technology
    • /
    • v.3 no.4
    • /
    • pp.177-180
    • /
    • 2017
  • Recently, as aging progresses rapidly around the world, studies using light (UV-LED, etc.) as a method which is harmless to the human body and less burden on the treatment are continuously being carried out. Especially, in some fields, it is not used in a limited way but it is advantageous to be used in various medical fields such as dermatology, dentistry, otorhinolaryngology, etc. In many advanced countries, various studies using it have been carried out. However, Are far behind in developed countries. Therefore, in this paper, we propose a technology that can provide good quality services to human patients by effectively controlling light module that can be used for medical use by using IoT crawler-based middleware platform.

The biocompatibility and mechanical properties of plasma sprayed zirconia coated abutment

  • Huang, Zhengfei;Wang, Zhifeng;Yin, Kaifeng;Li, Chuanhua;Guo, Meihua;Lan, Jing
    • The Journal of Advanced Prosthodontics
    • /
    • v.12 no.3
    • /
    • pp.157-166
    • /
    • 2020
  • PURPOSE. The aim of this study was to evaluate the clinical performance and reliability of plasma sprayed nanostructured zirconia (NSZ) coating. MATERIALS AND METHODS. This study consisted of three areas of analysis: (1) Mechanical property: surface roughness of NSZ coating and bond strength between NSZ coating and titanium specimens were measured, and the microstructure of bonding interface was also observed by scanning election microscope (SEM). (2) Biocompatibility: hemolysis tests, cell proliferation tests, and rat subcutaneous implant test were conducted to evaluate the biocompatibility of NSZ coating. (3) Mechanical compatibility: fracture and artificial aging tests were performed to measure the mechanical compatibility of NSZ-coated titanium abutments. RESULTS. In the mechanical study, 400 ㎛ thick NSZ coatings had the highest bond strength (71.22 ± 1.02 MPa), and a compact transition layer could be observed. In addition, NSZ coating showed excellent biocompatibility in both hemolysis tests and cell proliferation tests. In subcutaneous implant test, NSZ-coated plates showed similar inflammation elimination and fibrous tissue formation processes with that of titanium specimens. Regarding fatigue tests, all NSZ-coated abutments survived in the five-year fatigue test and showed sufficient fracture strength (407.65-663.7 N) for incisor teeth. CONCLUSION. In this study, the plasmasprayed NSZ-coated titanium abutments presented sufficient fracture strength and biocompatibility, and it was demonstrated that plasma spray was a reliable method to prepare high-quality zirconia coating.

Application of Nd-YAP laser to the conventional treatment of periodontal and endodontic combined lesions (Nd-YAP laser를 적용한 치주-근관 복합병소의 치료에 대한 고찰)

  • Kang, He-Kyong;Yoon, Ho-Jung
    • The Journal of the Korean dental association
    • /
    • v.47 no.8
    • /
    • pp.479-486
    • /
    • 2009
  • Purpose: The aim of this study was to show the clinical results of combination of Nd-YAP (1340nm) laser therapy with conventional endodontic and periodontal treatment. Materials and Methods: Four patients with chronic advanced periodontitis and endodontic infection were treated with conventional treatment and Nd-YAP laser therapy. Occlusal adjustment and splinting were done for stabilization of the teeth with severe horizontal and vertical mobility. The protocol for periodontal treatment was followed as scaling and root planing, pocket irrigation with 3% $H_2O_2$ and exposure of Nd-YAP laser using 320${\mu}m$ optical fiber with 160mJ/pluse, 30Hz. The other protocol for endodontic treatment was followed as access opening, canal preparation by hand and rotary instrument, canal filling, and exposure of Nd-YAP laser using 200${\mu}m$ optical fiber with 200mJ/pluse, 10Hz and 180mJ/pluse, 5Hz which were used respectively for disinfection and canal filling. The assessments of probing depth, mobility, and radiography were made prior to and after treatment. Result: All of these four clinical cases showed good healing of periodontium, which presented decrease of mobility and pocket depth, and increase of bone regeneration and bone density on the radiography. Conclusion: The bactericidal effect of Nd-YAP laser would provide benefits for improving clinical results that are obtained from conventional therapy.

  • PDF

Comparative evaluation of effects of different surface treatment methods on bond strength between fiber post and composite core

  • Mosharraf, Ramin;Yazdi, Najmeh Baghaei
    • The Journal of Advanced Prosthodontics
    • /
    • v.4 no.2
    • /
    • pp.103-108
    • /
    • 2012
  • PURPOSE. Debonding of a composite resin core of the fiber post often occurs at the interface between these two materials. The aim of this study was to evaluate the effects of different surface treatment methods on bond strength between fiber posts and composite core. MATERIALS AND METHODS. Sixty-four fiber posts were picked in two groups (Hetco and Exacto). Each group was further divided into four subgroups using different surface treatments: 1) silanization; 2) sandblasting; 3) Treatment with 24% $H_2O_2$, and 4) no treatment (control group). A cylindrical plexiglass matrix was placed around the post and filled with the core resin composite. Specimens were stored in 5000 thermal cycles between $5^{\circ}C$ and $55^{\circ}C$. Tensile bond strength (TBS) test and evaluation using stereomicroscope were performed on the specimen and the data were analyzed using two-way ANOVA, Post Hoc Scheffe tests and Fisher's Exact Test (${\alpha}$=.05). RESULTS. There was a significant difference between the effect of different surface treatments on TBS ($P$ <.001) but different brands of post ($P$=.743) and interaction between the brand of post and surface treatment ($P$=.922) had no significant effect on TBS. Both silanization and sandblasting improved the bonding strength of fiber posts to composite resin core, but there were not any significant differences between these groups and control group. CONCLUSION. There was not any significant difference between two brands of fiber posts that had been used in this study. Although silanization and sandblasting can improve the TBS, there was not any significant differences between surface treatments used.

The study of Shear Bond Strength on recasting of non-beryllium non-precious alloy for Porcelain between Metal (베릴륨이 포함되지 않은 도재용착주조관용 비 귀금속 합금의 재사용에 따른 금속과 도재간의 전단결합강도에 관한 연구)

  • Kim, So-Ri;Kim, Woong-Chul;Kim, Hae-Young;Kim, Ji-Hwan
    • Journal of Technologic Dentistry
    • /
    • v.35 no.1
    • /
    • pp.43-48
    • /
    • 2013
  • Purpose: This study aimed to investigate the shear bond strength for non-precious alloy castings without beryllium, which has been used repeatedly for economical reason. Methods: The Schmitz-Schulmeyer test method was used to evaluate the shear bond strength between the non-beryllium Ni-Cr alloy Vera Bond 2V(AlbaDent, Inc. USA) and the Ceramco 3(Dentstply, York, PA, USA) porcelain powder. The maximum loading and shear bond strength were measured. The average shear strength(MPa) was analyzed with the one-way ANOVA and the Tukey's test( =.05). The fracture specimens were examined using Microscope to determine the failure pattern. Results: The mean shear bond strengths(SD) in MPa were group A(100% new metal) control 28.72(3.31); group B(50% new + 50% reused) 27.28(1.13); group C(all reused) 26.61(5.47). Microscope examination showed that group A and B specimens presented mixed failure, and group C specimens showed adhesive failure. Conclusion: In conclusion, forward this non-precious alloy dose not contain beryllium for how should use a more systematic study and for future advanced research is performed giving effect to be considered desirable.

Variation of Axial Tension-Compression Fatigue Characteristics by UNSM on Ti-6Al-4V (Ti-6Al-4V재의 UNSM처리에 의한 축인장압축피로특성변화)

  • Suh, Chang-Min;Cho, Sung-Am;Pyoun, Young-Sik;Suh, Min-Soo
    • Journal of Ocean Engineering and Technology
    • /
    • v.25 no.6
    • /
    • pp.42-48
    • /
    • 2011
  • The present study makes three original contributions to nanoskinned Ti-6Al-4V materials. The nanoskins were fabricated on Ti-6Al-4V material using various surface treatments: deep rolling (DR), laser shot peening (LSP), and ultrasonic nanocrystal surface modification (UNSM). These surface treatments are newly developed techniques and are becoming more popular in industrial fields. A fatigue strength comparison at up to 106 cycles was conducted on these nanoskinned Ti-6Al-4V materials. Fatigue tests were carried out using MTS under axial loading tension-compression fatigue (R = -1, RT, 5 Hz, sinusoidal wave). The analysis of the crack initiation patterns in the nanoskinned Ti-6Al-4V materials found an interior originating crack pattern and surface originating crack type. Microscopic observation was mainly used to investigate the fatigue fractured sites. These surface modification techniques have been widely adopted, primarily because of the robust grade of their mechanical properties. These are mainly the result of the formation of a large-scale, deep, and useful compressive residual stress, the formation of nanocrystals by the severe plastic deformation (SPD) at the subsurface layer, and the increase in surface hardness.

A torque-measuring micromotor provides operator independent measurements marking four different density areas in maxillae

  • Di Stefano, Danilo Alessio;Arosio, Paolo;Piattelli, Adriano;Perrotti, Vittoria;Iezzi, Giovanna
    • The Journal of Advanced Prosthodontics
    • /
    • v.7 no.1
    • /
    • pp.51-55
    • /
    • 2015
  • PURPOSE. Bone density at implant placement site is a key factor to obtain the primary stability of the fixture, which, in turn, is a prognostic factor for osseointegration and long-term success of an implant supported rehabilitation. Recently, an implant motor with a bone density measurement probe has been introduced. The aim of the present study was to test the objectiveness of the bone densities registered by the implant motor regardless of the operator performing them. MATERIALS AND METHODS. A total of 3704 bone density measurements, performed by means of the implant motor, were registered by 39 operators at different implant sites during routine activity. Bone density measurements were grouped according to their distribution across the jaws. Specifically, four different areas were distinguished: a pre-antral (between teeth from first right maxillary premolar to first left maxillary premolar) and a sub-antral (more distally) zone in the maxilla, and an interforaminal (between and including teeth from first left mandibular premolar to first right mandibular premolar) and a retroforaminal (more distally) zone in the lower one. A statistical comparison was performed to check the inter-operators variability of the collected data. RESULTS. The device produced consistent and operator-independent bone density values at each tooth position, showing a reliable bone-density measurement. CONCLUSION. The implant motor demonstrated to be a helpful tool to properly plan implant placement and loading irrespective of the operator using it.

Perceived color shift of ceramics according to the change of illuminating light with spectroradiometer

  • Cha, Hyun-Suk;Yu, Bin;Lee, Yong-Keun
    • The Journal of Advanced Prosthodontics
    • /
    • v.5 no.3
    • /
    • pp.262-269
    • /
    • 2013
  • PURPOSE. Perceived color of ceramics changes by the spectral power distribution of ambient light. This study aimed to quantify the amount of shifts in color and color coordinates of clinically simulated seven all-ceramics due to the switch of three ambient light sources using a human vision simulating spectroradiometer. MATERIALS AND METHODS. CIE color coordinates, such as $L^*$, $a^*$ and $b^*$, of ceramic specimens were measured under three light sources, which simulate the CIE standard illuminant D65 (daylight), A (incandescent lamp), and F9 (fluorescent lamp). Shifts in color and color coordinate by the switch of lights were determined. Influence of the switched light (D65 to A, or D65 to F9), shade of veneer ceramics (A2 or A3), and brand of ceramics on the shifts was analyzed by a three-way ANOVA. RESULTS. Shifts in color and color coordinates were influenced by three factors (P<.05). Color shifts by the switch to A were in the range of 5.9 to 7.7 ${\Delta}E{^*}_{ab}$ units, and those by the switch to F9 were 7.7 to 10.2; all of which were unacceptable (${\Delta}E{^*}_{ab}$ > 5.5). When switched to A, CIE $a^*$ increased (${\Delta}a^*$: 5.6 to 7.6), however, CIE $b^*$ increased (${\Delta}b^*$: 4.9 to 7.8) when switched to F9. CONCLUSION. Clinically simulated ceramics demonstrated clinically unacceptable color shifts according to the switches in ambient lights based on spectroradiometric readings. Therefore, shade matching and compatibility evaluation should be performed considering ambient lighting conditions and should be done under most relevant lighting condition.

Analysis of the characteristics of mouthguards that affect isokinetic muscular ability and anaerobic power

  • Jung, Jae-Kwang;Chae, Woen-Sik;Lee, Kyu-Bok
    • The Journal of Advanced Prosthodontics
    • /
    • v.5 no.4
    • /
    • pp.388-395
    • /
    • 2013
  • PURPOSE. The purpose of this study was to estimate the effects of occlusal stability to identify action mechanisms of mouthguards, known to have a modulatory effect on limb muscle function. MATERIALS AND METHODS. This study included 20 male subjects to perform the isokinetic muscle tests and the Wingate anaerobic power test on both knee joints under five closed-mouth conditions: without or with 4 types of mouthguards with thickness of 2 mm based on premolar area: (1) full-coverage, (2) anterior partial-coverage, (3) right posterior partial-coverage, and (4) left posterior partial-coverage. The obtained results were subjected to One-way ANOVA with repeated measures, followed by post hoc test of the contrast method (${\alpha}$=.05). RESULTS. There was no significant difference between the closed position with and without a full-coverage mouthguard in all variables. However, significant differences were observed between with and without a partial-coverage mouthguard in muscular endurance during extension of the left knee, muscular power and endurance during flexion of the right knee. Additionally, significant differences were found between occlusal states with full- and partial-coverage mouthguards in muscular power and endurance during extension of the left knee. CONCLUSION. These findings indicate the elevation of vertical dimension by 2 mm or the inducement of occlusal stability had little effect on isokinetic muscle strength and anaerobic performance, while uneven distribution of occlusal force might have some positive effects.