• Title/Summary/Keyword: Adsorption Control system

Search Result 77, Processing Time 0.023 seconds

Experimental Verification of Adsorption Rate Feedback Control Strategy for Automotive Urea-SCR DeNOX System (실차 실험을 통한 승용 디젤엔진의 Urea-SCR을 위한 암모니아 흡장률 피드백 제어 분사전략 검증)

  • Shin, Byeonguk;Park, Jooyoung;Lee, Seang Wock;Kang, Yeonsik
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.41 no.6
    • /
    • pp.397-407
    • /
    • 2017
  • In this study, a SCR system is employed to selectively reduce $NO_X$, which is a major cause of environmental pollution and issues in diesel engines. In particular, this paper focuses on the combination of feedforward injection strategies, depending on the NO/$NO_X$ ratio, and feedback injection control, using $NH_3$ coverage ratio, based on a SCR model. A 2.2 L passenger diesel engine, which is equipped with a diesel oxidation catalyst (DOC) and a diesel particle filter (DPF), was used in the experiments. The developed control algorithm is implemented on a real-time computer with injection control algorithm. By analyzing the $NO_X$ emission measurement, the performance of the proposed injection control algorithm is verified.

Effects of Soil Texture, Irrigation System, and Soil Ameliorators on the Cadmium Adsorption in Soil and Uptake in Rice Plant (토양의 카드뮴흡착과 수도체 카드뮴흡수에 미치는 토성, 물관리 및 개량제 효과)

  • Jung, Goo-Bok;Kim, Kyu-Sik;Lee, Jong-Sik;Kwon, Soon-Ik
    • Korean Journal of Environmental Agriculture
    • /
    • v.19 no.2
    • /
    • pp.128-133
    • /
    • 2000
  • This study was conducted to investigate the adsorptive characteristics with cadmium in different levels of organic matter and lime in soil. And in order to identify the effect of soil ameliorators on cadmium uptake in rice plants, compost and lime were treated. Plants were grown at two soil textures(sandy loam and clay loam) with irrigation water containing $0.01\;mg\;L^{-1}$ of cadmium and treatments of two irrigation systems(intermittent irrigation and continuous submersion). The adsorption capacity of cadmium by soil was increased in proportion to initial concentration of solution, and it was higher at clay soil compared to loamy soil. The adsorption rate of cadmium by soil was increased with increasing the concentration of organic matter and lime in soil, highly increased at the both organic matter and lime treatment. Soil pH was negatively correlated with the cadmium contents of the both shoot and brown rice while Eh was positively correlated with those. In the harvest season, cadmium contents in the both leaves and brown rice were lower in the clay sail plots than sandy soil plots, and the continuous submersion plots were lower than intermittent irrigation plots. Cadmium uptake was highly reduced at the compost and lime mixture plot compared to other treatments among the continuous submersion plots. The cadmium content of shoot was positively correlated with that of brown rice in the harvest season.

  • PDF

Recent Progress in Air-Conditioning and Refrigeration Research : A Review of Papers Published in the Korean Journal of Air-Conditioning and Refrigeration Engineering in 2015 (설비공학회 분야의 최근 연구 동향 : 2015년 학회지 논문에 대한 종합적 고찰)

  • Lee, Dae-Young;Kim, Sa Ryang;Kim, Hyun-Jung;Kim, Dong-Seon;Park, Jun-Seok;Ihm, Pyeong Chan
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.28 no.6
    • /
    • pp.256-268
    • /
    • 2016
  • This article reviews the papers published in the Korean Journal of Air-Conditioning and Refrigeration Engineering during 2015. It is intended to understand the status of current research in the areas of heating, cooling, ventilation, sanitation, and indoor environments of buildings and plant facilities. Conclusions are as follows. (1) The research works on the thermal and fluid engineering were carried out in the areas of flow, heat and mass transfer, cooling and heating, and air-conditioning, the renewable energy system and the flow inside building rooms. Research issues dealing with air-conditioning machines and fire and exhausting smoke were reduced. CFD seems to be spreading to more research areas. (2) Research works on heat transfer area were carried out in the categories of heat transfer characteristics, pool boiling and condensing heat transfer and industrial heat exchangers. Researches on heat transfer characteristics included the economic analysis of GHG emission, micro channel heat exchanger, effect of rib angle on thermal performance, the airside performance of fin-and-tube heat exchangers, theoretical analysis of a rotary heat exchanger, heat exchanger in a cryogenic environment, the performance of a cross-flow-type, indirect evaporative cooler made of paper/plastic film. In the area of pool boiling and condensing, the bubble jet loop heat pipe was studied. In the area of industrial heat exchangers, researches were performed on fin-tube heat exchanger, KSTAR PFC and vacuum vessel at baking phase, the performance of small-sized dehumidification rotor, design of gas-injection port of an asymmetric scroll compressor, effect of slot discharge-angle change on exhaust efficiency of range hood system with air curtain. (3) In the field of refrigeration, various studies were carried in the categories of refrigeration cycle, alternative refrigeration/energy system, system control. In the refrigeration cycle category, a cold-climate heat pump system, $CO_2$ cascade systems, ejector cycles and a PCM-based continuous heating system were investigated. In the alternative refrigeration/energy system category, a polymer adsorption heat pump, an alcohol absorption heat pump and a desiccant-based hybrid refrigeration system were investigated. In the system control category, turbo-refrigerator capacity controls and an absorption chiller fault diagnostics were investigated. (4) In building mechanical system research fields, eighteen studies were reported for achieving effective design of the mechanical systems, and also for maximizing the energy efficiency of buildings. The topics of the studies included energy performance, HVAC system, ventilation, and renewable energies, piping in the buildings. Proposed designs, performance tests using numerical methods and experiments provide useful information and key data which can improve the energy efficiency of the buildings. (5) The field of architectural environment was mostly focused on indoor environment and building energy. The main researches of indoor environment were related to the user and location awareness technology applied dimming lighting control system, the lighting performance evaluation for light-shelves, the improvement evaluation of air quality through analysis of ventilation efficiency and the evaluation of airtightness of sliding and LS window systems. The subjects of building energy were worked on the energy saving estimation of existing buildings, the developing model to predict heating energy usage in domestic city area and the performance evaluation of cooling applied with economizer control. The studies were also performed related to the experimental measurement of weight variation and thermal conductivity in polyurethane foam, the development of flame spread prevention system for sandwich panels, the utilization of heat from waste-incineration facility in large-scale horticultural facilities.

A Study on the Influence of Automatic Control System on the Production of Chemical Propylene (자동제어 시스템이 케미칼 프로플린 생산에 미치는 영향 연구)

  • Lee, Oh Sick;Leem, Choon Seong
    • Journal of Convergence for Information Technology
    • /
    • v.9 no.2
    • /
    • pp.34-42
    • /
    • 2019
  • In this study, we analyzed the effects of the automatic control system on the reactor operation. The Propyrene Reactor process is complex and typically is inefficient and costly due to the lack of productivity. In this study, a research model was presented with the aim of supplementing obstacles to enhance operational efficiency and increase productivity. The configuration of the existing processes was analyzed to complement the hardware and software systems with original models. The composition of the facility is applied to eight reactor units producing 600,000 ton/year propylene per year. As a result of applying the research model, efficiency of operation was increased, and production volume increased from 90 to 95%, along with 91% Reliability. Future studies will present a research model to improve productivity by 100 percent. In addition, we will study the stability and productivity improvement of PSA (Pressure Swing Adsorption) systems, which are the hydrogen production process of propylene by-products.

Performance Evaluation of a Double Layer Biofilter System to Control Urban Road Runoff (I) - System Design - (이중층 토양 여과시설을 이용한 도로 강우 유출수 처리성능 평가 (I) - 시설 설계인자 결정을 중심으로 -)

  • Cho, Kang Woo;Kim, Tae Gyun;Lee, Byung Ha;Lee, Seul Bi;Song, Kyung Guen;Ahn, Kyu Hong
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.23 no.5
    • /
    • pp.599-608
    • /
    • 2009
  • This manuscript covers the results of field investigation and lab-scale experiments to design a double-layered biofilter system to control urban storm runoff. The biofilter system consisted of a coarse soil layer (CSL) for filtration and fine soil layer (FSL) for adsorption and biological degradation. The variations of flow rate and water quality of runoff from a local expressway were monitored for seven storm events. Laboratory column experiments were performed using seven kinds of soil and mulch to maximize pollutants removal. The site mean concentration (SMC) of storm runoff from the drainage area (runoff coefficient: 0.92) was measured to be 203 mg/L for SS, 307 mg/L for $TCOD_{Cr}$, 12.3 mg/L for TN, 7.3 mg/L for ${NH_4}^+-N$, and 0.79 mg/L for TP, respectively. This study employed a new design concept, to cover the maximum rainfall intensity with one month recurrence interval. Effective storms for last ten years (1998-2007) in seoul suggested the design rainfull intensity to be 8.8 mm/hr Single layer soil column showed the maximum removal rate of pollutants load when the uniformity coefficient of CSL was 1.58 and the silt/clay contents of FSL was virtually 7%. The removal efficiency during operation of double layer soil column was 98% for SS and turbidity, 75% for TCODCr, 56% for ${NH_4}^+-N$, 87% for TP, and 73-91% for heavy metals. The hydraulic conductivity of the soil column, 0.023 cm/sec, suggested that the surface area of the biofilter system should be about 1% of the drainage area to treat the rainfall intensity of one month recurrence interval.

Development of Unmanned Cleaning Robot for Photovoltaic Panels (태양광발전시설 무인 유지보수 로봇 개발)

  • Lee, Hyungyu;Lee, Sang Soon
    • Journal of the Semiconductor & Display Technology
    • /
    • v.18 no.3
    • /
    • pp.144-149
    • /
    • 2019
  • This paper describes the results of a study on the unmanned maintenance robot that simultaneously performs the cleaning and inspection of the photovoltaic panels. The robot has a special adsorptive device, an infrared sensor, a vacuum level sensor and a camera. The robot uses two SSC (Sliding Suction Cup) adsorptive devices to move up and down the slope. First, the forces generated when the robot moves up the slope are mechanically analyzed, and the required design and control of the adsorption system are suggested. The robot was designed and manufactured to operate stably by using the presented results. Next, the normal force between the panel and the wheel was measured to confirm that the robot was manufactured and operated as intended, and the robot motion was tested on the inclined panel. It has been proven that robots are well designed and built to clean and inspect sloped panels.

Analysis of Volatile Organic Compounds in Water by Modified Injection Mode for Purge & Trap-GC/MS Method (Purge & Trap-GC/MS 분석법의 주입방식 개선에 의한 물 중의 휘발성 유기물 분석)

  • Jeon, Chi Wan;Lee, Sang Hak;Eum, Chul Hun
    • Journal of the Korean Chemical Society
    • /
    • v.39 no.8
    • /
    • pp.635-642
    • /
    • 1995
  • Improved sample introduction system has been investigated for the determination of volatile organic compounds in water using a purge & trap preconcentration apparatus and a capillary gas chromatography/mass spectrometry. The present limitations associated with the moisture control module and cryorefocusing system suggested by EPA were discussed. To solve the problems such as improper separation of peaks due to the adsorption of water and contamination of purge & trap system, a more efficient connection system between the purge & trap apparatus and the gas chromatograph was introduced and the optimum operational conditions were suggested. A carbopack B/carboxen 1000 and 1001 trap was used for the purge & trap procedure and a custom made crosslinked dimethyldiphenylpolysiloxane capillary column was used for the separation of compounds. Accuracy and precision of the method suggested in this report were examined and the method detection limit of each compound was proposed for the simultaneous determination of 54 volatile organic compounds in water.

  • PDF

Correlation between Corrosion Rate and Red Water on Application of Corrosion Inhibitor in Drinking Water Distribution System (배급수 계통에서 부식억제제 적용에 따른 부식과 적수와의 상관관계)

  • Woo, Dal-Sik;Ku, Sung-Eun;Lee, Byung-Doo;Kim, Ju-Hwan;Moon, Kwang-Soon
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.19 no.1
    • /
    • pp.68-77
    • /
    • 2005
  • This study was performed to evaluate the application of corrosion inhibitor and to examine the correlation between corrosion rate and red water in a series of batch tests and a test using auto corrosion monitoring system at A water treatment plant in Gyeonggido. The corrosion study in the auto corrosion monitoring system indicated that Fe concentration decreased by 30~50% and corrosion rate also reduced remarkably with corrosion inhibitor at $1.8mg\;PO_4/L$. After addition of corrosion inhibitor, it was indicated the effective adsorption of the inhibitor on the surface of the pipe line forming a protective film. The corrosion rate increases with the increase in Fe concentration. With $1.8mg\;PO_4/L$ of corrosion inhibitor, the corrosion rate decreased remarkably. Fe concentration had correlation to not only red water problems but also the corrosion rate that actually dissolved into the water, primarily due to the deposition of oxidized iron or other compounds as a scale, which serves as a large reservoir of corrosion by-product. Therefore, corrosion rate can be estimated by Fe concentration. For these reasons, an effective corrosion inhibitor is also an effective red water control reagent. The effect of the corrosion inhibition can last for some time even the application the corrosion inhibitor is discontinued. For the cost effective and efficient corrosion control, the concentration and timing of corrosion inhibitor addition must be determined properly.

In Vitro Stability of Liposomes Containing Newly Synthesized Glycolipid (신규 합성 당지질 함유 리포솜의 In Vitro 안정성)

  • Song, Chung-Kil;Jung, Soon-Hwa;Seong, Ha-Soo;Cho, Sun-Hang;Shin, Byung-Cheol
    • Journal of the Korean Chemical Society
    • /
    • v.51 no.1
    • /
    • pp.43-50
    • /
    • 2007
  • Liposomes having particle size from several tens to hundreds nanometers are efficient carriers for injectable drug delivery. Enhancement of liposome stability in bloodstream has been studied because of its relatively short circulation time and fast clearance from human body by reticuloendothelial system (RES) in blood vessel. In this study, new disaccharide-1,2-distearoyl-sn-glycero-3-phosphoethanolamine (DSPE) derivatives in which lactose or sucrose as the disaccharide molecule was conjugated covalently to DSPE were synthesized. Liposomes of which surface had disaccharide molecules were prepared by incorporating the disaccharide-DSPE into liposomes as one of their lipid components. Particle size of the prepared liposomes was approximately 100 nm. The liposomes of which surface were modified with the disaccharide-DSPE showed -25 mV of zeta potential value due to the presence of hydroxyl groups on their surface, while the unmodified control liposomes showed -10 mV of zeta potential value. Loading efficiency of model drug, doxorubicin, into liposomes was about 90%. Stability of the disaccharide-modified liposomes in vitro was evaluated by monitoring the amount of protein adsorption and particle size of the liposomes in serum. Disaccharide-modified liposomes were more stable in serum than unmodified control liposomes or polyethyleneglycol (PEG)-modified liposomes due to less adsorption of serum protein and hence less increase of their particle size. The liposomes of which surface was modified with disaccharide-DSPE conjugate can be used as long-circulating carriers for drugs having high toxicity or short half-life time due to their enhanced stability in blood circulatory system.

Dyeing Behavior of Silk/CDP Mixed Filament with a Cationic Dye (캐티온염료를 이용한 Silk/Cationic Dyeable Polyester 혼합사의 염색거동)

  • Choe, Jong-Mun;Gwon, Hae-Yong;Park, Yeong-Hwan
    • Journal of Sericultural and Entomological Science
    • /
    • v.37 no.2
    • /
    • pp.154-160
    • /
    • 1995
  • Dyeing behavior of Silk/Cationic dyeable polyester(CDP) mixed filament was investigated by using a cationic dye. The effect of pH, temperature and additives such as carrier, levelling agent and salt were examined for each silk and CDP component of mixed filament in order to find out the optimum dyeing condition. Based on these results, the dyeing behavior was investigated for Silk/CDP mixed filaments concering various dyeing parameters. The dye adsorption was significantly changed on the dyeing temperature, carrier addition and pH of the dyebath. Specially, the dye migration phynomena were observed for a mixed filament, showing that the dyes initially observed on the surface of silk fiber migrate to the CDP component during a dyeing process. The dyeing of Silk/CDP mixed filaments accompanied by dye migration and as a result, dye adsorption can be developed only for a CDP component. Therefore, the control of dyeing temperature is most important for a Silk/CDP mixed filament, in order that both silk and CDP component are able to be dyed by a cationic dye simultaneously in one bath/one dye system.

  • PDF