• Title/Summary/Keyword: Adsorbent column

Search Result 88, Processing Time 0.023 seconds

Multicomponent analysis of metabolites of low volatility in biological fluids by field ionization mass spectrometry

  • Kim, Kyoung-Rae;Anbar, Michael
    • Archives of Pharmacal Research
    • /
    • v.7 no.1
    • /
    • pp.23-31
    • /
    • 1984
  • An improved mass spectrometric method for multicomponent analysis of metabolites in urine, well-suited for clinical biochemistry, is described. The method involves solvent elution of the metabolites from an adsorbent and the concentration of the eluate on a microadsorption column. This is administered by a direct inlet probe into the ionizing source of field ionization mass spectrometry (FIMS), which yield a molecular weight profile of the metabolites. The procedure provides rapidly (within one hour) reproducible profiles from a small volume of urine. The optimization of the sampling technique and the reproducibility are discussed.

  • PDF

Separation of Freon-12 and Air Mixture by Adsorption Process (흡착공정을 이용한 프레온-12와 공기혼합가스의 분리)

  • 강석호;이태진;안희관;김윤갑
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.9 no.1
    • /
    • pp.101-106
    • /
    • 1993
  • In order to separate the Freon-12 and air mixture$(CF_2Cl_2/Air=0.1/99.9 vol.%)$ by pressure swing adsorption (PSA), the breakthrough curve was experimentally observed in a fixed bed adsorption column. A single adsorber was packed with various adsorbents such as, the activated carbon(S-AC, W-AC) and the molecular sieve(MS-5A, MS-13X). The order of appearance of breakthrough curve is MS-5A > MS-13X > W-AC > S-AC. The activated carbon was found to be more effective adsorbent for separating Freon-12 from the mixture than the molecular sieve was. From the experimental data obtained by the separation of Freon-12 gas out of the air stream in the steady-state PSA process cycle, whose size is the same one of column used for the breakthrough curve observation, it has been confirmed that Freon-rich gas could be obtained from the purge step of PSA and Freon-free air could be obtained from the adsorption step of PSA cycle.

  • PDF

Breakthrough Characteristics for Lithium Ions Adsorption in Fixed-bed Column Packed with Activated Carbon by Modified with Nitric Acid (질산으로 개질한 활성탄을 충전한 고정층에서 리튬이온 흡착시의 파과특성)

  • Kam, Sang-Kyu;You, Hae-Na;Lee, Min-Gyu
    • Journal of Environmental Science International
    • /
    • v.23 no.6
    • /
    • pp.1143-1149
    • /
    • 2014
  • The adsorption experiments of lithium ions were conducted in the fixed bed column packed with activated carbon modified with nitric acid. Effect of inlet concentration, bed hight and flow rate on the removal of lithium ions was investigated. The experimental results showed that the removal and the adsorption capacity of lithium ions increased with increasing inlet concentration, and decreased with increasing flow rate. When the bed height increased, the removal and the adsorption capacity increased. The breakthrough curves gave a good fit to Bohart-Adams model. Adsorption capacity and breakthrough time calculated from Bohart-Adams model, these results were remarkably consistent with the experimental values. The adsorption capacity was not changed in the case of 3 times repetitive use of adsorbent.

Removal of Heavy Metals, Cd(II) and Pb(II) Ions in water by Sargassum Herneri (괭생이 모자반에 의한 수중 중금속 Cd(II), Pb(II) 이온의 제거)

  • Park, Kwang-Ha;Park, Mi-A;Jang, Hoon;Kim, Eun-Kyung;Kim, Young-Ha
    • Analytical Science and Technology
    • /
    • v.12 no.3
    • /
    • pp.196-202
    • /
    • 1999
  • Brown algae, Sargassum horneri, was used as an adsorbent to remove heavy metal Cd(II) and Pb(II) ions. Sargassum horneri picked in East Coast was formulated into the grain with the size of 40-60 mesh after wind dry. Batch method was used in order to investigate the adsorption rate by measuring the adsorption amounts with shaking time. In the column method, the adsorption amounts were measured by flowing metal solutions into the algae-packed column at the rate of 1 ml/min. Adsorption amounts in both batch method and column method were in the following order : pH 10.5>7.0>3.5. It was found that Pb(II) was more adsorbed on the algae grain than Cd(II). It was also revealed that the adsorption amounts reached the maximum within 5 minutes irrespective of pH condition in the batch method. It was concluded that the batch method was more effective than the column method in terms of recovery rate.

  • PDF

Sorption and Leaching Studies of Fenitrothion and Tebuconazole in Granular Activated Carbon and Charcoal (Fenitrothion과 Tebuconazole의 입상 활성탄 및 차콜에 의한 흡착과 용탈에 관한 연구)

  • Lee, Dong-Ik;Chun, So-Ul;Joo, Young-Kyoo
    • Asian Journal of Turfgrass Science
    • /
    • v.20 no.1
    • /
    • pp.47-55
    • /
    • 2006
  • Golf course community has always been concerned about water quality regarding to pesticide and fertilizer managements. This study conducted to investigate sorption and leaching behavior of common pesticides used for golf course in granular activated carbon I (GAC 1), granular activated carbon II(GAC II), and charcoal. We used batch study to investigate the influence of concentrations of Smithion and Folicur and particle sizes of GAC I, GAC II, and charcoal on sorption. Also, column study was used to investigate the leaching effect of Smithion in GAC I and charcoal. We found that sorption of Smithion and Folicur were higher in less $45{\mu}m$ of particle size for GAC I, GAC II, and charcoal compared to $1.7{\sim}2.0mm$ size, and the sorption of Smithion and Folicur in less $45{\mu}m$ of particle size ranged from 90 to 99%. In the column study, there was no difference in leaching effect between GAC I and charcoal. Overall, we found that charcoal might offer a cost effective adsorbent as a pesticides in leachate.

Development of On-Line Measurement System for Adsorption Process (흡착공정용 온라인 측정시스템의 개발)

  • Kim, Byoung Chul;Lee, Ki Sung;Yamamoto, Takuji;Kim, Young Han
    • Korean Chemical Engineering Research
    • /
    • v.47 no.3
    • /
    • pp.321-326
    • /
    • 2009
  • A simple measuring device is proposed, and its performance is examined in an adsorption process separating a gas mixture. The sensor is made of a quartz crystal resonator and solid adsorbent to detect the target component. Micro-particle carbon cryogel(MCC) is utilized as the adsorbent, and the gas mixture of air and i-butane are separated in a column containing bamboo activated carbon. Two devices are placed at the inlet and outlet of the column. The measurements are compared with those of GC outcome to prove the measurements are effective. The experimentally proved system is simple and capable to be implemented in an in-line system with on-line measurement.

Hydrogels with diffusion-facilitated porous network for improved adsorption performance

  • Pei, Yan-yan;Guo, Dong-mei;An, Qing-da;Xiao, Zuo-yi;Zhai, Shang-ru;Zhai, Bin
    • Korean Journal of Chemical Engineering
    • /
    • v.35 no.12
    • /
    • pp.2384-2393
    • /
    • 2018
  • Porous alginate-based hydrogel beads (porous ABH) have been prepared through a facile and sustainable template-assisted method using nano-calcium carbonate and nano-$CaCO_3$ as pore-directing agent for the efficient capture of methylene blue (MB). The materials were characterized by various techniques. The sorption capacities of ABH towards MB were compared with pure sodium alginate (ABH-1:0) in batch and fixed-bed column adsorption studies. The obtained adsorbent (ABH-1:3) has a higher BET surface area and a smaller average pore diameter. The maximum adsorption capacity of ABH-1:3 obtained from Langmuir model was as high as $1,426.0mg\;g^{-1}$. The kinetics strictly followed pseudo-second order rate equation and the adsorption reaction was effectively facilitated, approximately 50 minutes to achieve adsorption equilibrium, which was significantly shorter than that of ABH-1:0. The thermodynamic parameters revealed that the adsorption was spontaneous and exothermic. Thomas model fitted well with the breakthrough curves and could describe the dynamic behavior of the column. More significantly, the uptake capacity of ABH-1:3 was still higher than 75% of the maximum adsorption capacity even after ten cycles, indicating that this novel adsorbent can be a promising adsorptive material for removal of MB from aqueous solution under batch and continuous systems.

Removal of Manganese(II) from Aqueous Solution Using Manganese Coated Media (망간코팅 여재를 이용한 수용액상의 망간 제거연구)

  • Kim, Seok-Jun;Kim, Won-Gee;Lee, Seung-Mok;Yang, Jae-Kyu
    • Journal of Korean Society on Water Environment
    • /
    • v.26 no.3
    • /
    • pp.454-459
    • /
    • 2010
  • This study investigated the applicability of manganese coated media such as manganese coated sand (MCS), manganese coated sericite (MCSe) and manganese coated starfish material calcined at $550^{\circ}C$ (MCSf) to remove Mn(II) in synthetic wastewater. Manganese coated media prepared at different pH was applied in the treatment of soluble Mn(II) in batch and column experiments at various Mn(II) concentrations. The amount of Mn coated on three different media was approximately 800~1100 mg/kg. From the stability test, negligible dissolution of Mn was observed above pH 3.0. In batch test, more than 40% of Mn(II) was removed by all sand media at various manganese concentrations. In order to see the effect of additional oxidant for the removal of Mn(II), 4 mg/L of hypochlorite was added in Mn(II) solution during column experiment. Breakthrough of Mn(II) was greatly retarded in the presence of hypochlorite in all column reactors packed with different media. Among the manganese coated media, MCSf prepared at pH 4 indicated the highest removal capacity. The removal efficiency of Mn(II) was also increased in the multi-layer system (0.5 g of MCS, MCSe, and MCSf each).

Anodic Stripping Differential Pulse Voltammetric Determination of Trace Amounts of Lead after Preconcentration of Its Complex with 2-(5-Bromo-2-pyridylazo)-5-diethylaminophenol onto Natural Analcime Zeolite by Column Method

  • Taher, Mohammad Ali;Mostafavi, Ali;Afzali, Darush;Rezaeipour, Ebrahim
    • Bulletin of the Korean Chemical Society
    • /
    • v.25 no.8
    • /
    • pp.1125-1129
    • /
    • 2004
  • This work assesses the potential of natural Analcime Zeolite as an adsorbent for preconcentration of lead (II) traces. Lead is quantitatively retained on 2-(5-bromo-2-pyridylazo)-5-diethylaminophenol by column method with Analcime in the pH range of 5-6.5 and 2 mL $min^{?1}$ flow rate. Lead was removed from the column with 10.0 mL of 4 M hydrochloric acid and was determined by anodic stripping differential pulse voltammetry. 0.5ppb detection limit was obtained and linear dynamic range was 3 to $1.2{\times}10^5$ ppb in final solution with correlation coefficient of 0.999 and relative standard deviation of ${\pm}$ 1.2% (for eight replicate determination of 2.5 ${\mu}g\;mL^{?1}$ of lead). Various parameters such as the effect of pH, flow rate, instrumental conditions and interferences of some ions on the determination of lead have been studied in detail for optimization of conditions. The method was successfully applied for determination of lead in various samples.

Investigation of Cryogenic Breakthrough Curve Measurement System at 77 K for Hydrogen Isotopologue Separation (수소 동위원소 분리를 위한 77 K 극저온 파과 곡선 측정 시스템 제작)

  • Kim, Suhwan;Oh, Hyunchul
    • Korean Journal of Materials Research
    • /
    • v.32 no.1
    • /
    • pp.36-43
    • /
    • 2022
  • Breakthrough analysis has widely been explored for the dynamic separation of gaseous mixtures in porous materials. In general, breakthrough experiments measure the components of a flowing gas when a gaseous mixture is injected into a column filled with an adsorbent material. In this paper, we report on the design and fabrication of a breakthrough curve measurement device to study the dynamic adsorptive separation of hydrogen isotopologues in porous materials. Using the designed system, an experiment was conducted involving a 1:1 mixture of hydrogen and deuterium passed through a column filled with zeolite 13X (1 g). At room temperature, both hydrogen and deuterium were adsorbed in negligible amounts; however, at a temperature of 77 K, deuterium was preferentially adsorbed over hydrogen. The selectivity was different from that in the existing literature due to the different sample shapes, measurement methods, and column structures, but was at a similar level to that of cryogenic distillation (1.5).