사용환경온도에 따른 접착이음의 인장전단강도 변화 (Variation of fracture strength of adhesive joint according to the operating temperature)

  • 김재영;이찬주;이상곤;박근환;정병훈;;김병민
    • 한국소성가공학회:학술대회논문집
    • /
    • 한국소성가공학회 2008년도 춘계학술대회 논문집
    • /
    • pp.517-520
    • /
    • 2008
  • Recently, use of adhesive bonding technology is increased to achieve the multi-material design for lightweight structure in automobile industry. In this paper, the fracture strength of adhesive has been studied with the single lap shear test conducted at different temperatures. The joint specimens are made from Al 5052 and SPRC 440 bonded with structural epoxy adhesive. The operating temperature has been considered up to $150[^{\circ}C]$ and the single lap shear test has been conducted with 5mm/min tensile rate. Fracture strength of adhesive bonded joint has been decreased with increase of operating temperature. The fracture strength at the $100[^{\circ}C]$ was shown about half of that at room temperature.

  • PDF

복합레진과 Glass Ionomer Cement수복물에 대한 Bracket의 접착전단강도 (THE SHEAR BOND STRENGTH OF TWO ADHESIVES BONDED TO COMPOSITE RESIN AND GLASS IONOMER CEMENT RESTORATIONS)

  • 한재익;이병태
    • 대한치과교정학회지
    • /
    • 제20권3호
    • /
    • pp.583-591
    • /
    • 1990
  • If the bond strength is sufficient to resist orthodontic force, orthodontic brackets can be bonded to restorations. Orthodontic brackets were bonded to composite resin and glass ionomer cement restorations with no-mix adhesive or glass ionomer cement. The shear bond strength of adhesives bonded to restorations was studied in vitro. Orthodontic brackets were bonded to 10 extracted natural teeth, 40 composite resin restorations and 40 glass ionomer restorations. The surfaces of composite resin restorations were roughened or applied with bonding agent (Scothbond) after surface roughening. The surfaces of glass ionomer cement restorations were conditioned with acid etching or applied with Scotchbond to etched surface. The adhesive was no-mix resin or glass ionomer cement. The shear bond strength was measured. The results were as follows: 1. Orthodontic brackets could be bonded to composite resin restorations effectively as they could be bonded to acid etched enamel with no-mix adhesive. The shear bond strength was sufficient to resist orthodontic force and was not affected by bonding agent greatly. 2. The shear bond strength of no-mix adhesive bonded to acid etched glass ionomer cement restorations was sufficient to resist orthodontic force. However. the fracture risk of glass ionomer cement restorations was increased during debonding. The bonding agent couldn't increase the shear bond strength greatly. 3. The shear bond strength of glass ionomer cement bonded to glass ionomer cement restorations was lower than that of no-mix adhesive. The shear bond strength was sufficient to resist orthodontic force and was greatly decreased by bonding agent. 4. The shear bond strength of glass ionomer cement bonded to composite resin restorations was too low to resist orthodontic force.

  • PDF

EXPERIMENTAL STUDY ON PROBABILITY OF STRENGTH FOR EPOXY ADHESIVE-BONDED METALS

  • Seo, Do-Won;Lim, Jae-Kyoo;Jeon, Yang-Bae;Yoon, Ho-Cheol
    • 대한용접접합학회:학술대회논문집
    • /
    • 대한용접접합학회 2002년도 Proceedings of the International Welding/Joining Conference-Korea
    • /
    • pp.688-693
    • /
    • 2002
  • Adhesive bonding is becoming one of the popular joining techniques in metal industries, since it has some advantages over other techniques such as welding and diffusion bonding, e.g., any dissimilar metals are easily adhesive-bonded together. In this study, the experiments were carried out in order to provide the statistical data with strength evaluation methods: tension, shear and four-point bending tests for thermoplastic epoxy resin based adhesive-bonded metal joints. We should certificate on the probability of the adhesive strength that has the tendency of brittle fracture, the adhesive bonding strength between metals with thermoplastic adhesive has the best probability at four-point bending test. The strength testing method that has higher probability is four-point bending test, shear test and tensile test in order.

  • PDF

고분자 접착제와 금속 피착재의 접착강도에 미치는 피착재 두께의 영향 (Effects of Adherend Thickness on Adhesive Strength between Organic Adhesive and Metal Adherend)

  • 하윤근;심준형;백주환;김민균;조영래
    • 마이크로전자및패키징학회지
    • /
    • 제27권4호
    • /
    • pp.127-133
    • /
    • 2020
  • 고분자 재료인 접착제와 금속 피착재 사이의 정량적인 접착강도 측정은 중요하다. 고분자 재료인 접착제와 금속 피착재 사이의 접착강도 측정 시, 피착재의 종류와 두께 변화가 접착강도에 미치는 영향에 대해 연구하였다. 금속 피착재의 종류로는 알루미늄과 스텐리스강 2종류가 선택되었으며, 접착강도의 측정에는 돌리테스트와 전단시험이 사용되었다. 인장응력 방식의 돌리테스트로 고분자 접착제와 금속 피착재 사이의 접착강도 측정 시, 금속 피착재의 두께 변화는 접착강도의 크기에 거의 영향을 미치지 않았으나, 피착재의 종류에 따라 접착강도는 다르게 나타났다. 반면, 전단시험으로 고분자 접착제와 금속 피착재 사이의 접착강도 측정 시, 금속 피착재의 상대적 두께 변화는 접착강도의 크기에 영향을 주었다. 이유는 전단시험 시 접착부의 모서리 부분에서 발생하는 피착재의 휘어짐 현상은 접착부에 추가적인 인장응력을 발생시켜 접착강도를 낮추는데 기여하기 때문이다. 이 연구의 결과, 돌리테스트는 피착재의 두께가 변해도 접착강도의 변화가 거의 없기 때문에 고분자 접착제와 금속 피착재의 정량적인 접착강도 측정 시 널리 사용될 것으로 예상된다.

접착제 접합 이음부 접합강도 평가에 대한 실험적 연구 (Experimental Study on Evaluation of Bonding Strength of Adhesively Bonded Joints by Adhesive)

  • 강기엽;이제명
    • Journal of Welding and Joining
    • /
    • 제30권6호
    • /
    • pp.62-67
    • /
    • 2012
  • In this study, the bonding strengths of adhesively bonded joints are experimentally investigated. A series of lap-shear tests are conducted using single lap type adhesive joints. In order to analyse the joint fabrication factors that affected the bonding strength, the parametric tests are conducted with various thickness of adhesive, surface roughness and fillet of adhesive. In addition, for the comparative study with the welded joint, lap-shear tests using specimens with 2 welded sides and 4 welded sides are also carried out. The quantitative results of the strength analysis are summarized, and some proposals are made on setting up testing standards for adhesively bonded joints.

AI합금 단순겹치기 접착이음의 인장-전단강도 평가 (The Evaluation of Tensile-shear Strength on the Al-Alloy Single-lap Adhesive Joints)

  • 오승규;유영철;정의섭;이원
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 1997년도 춘계학술대회 논문집
    • /
    • pp.567-571
    • /
    • 1997
  • Recently, automobile industry has led to increasing use of aluminum alloy for weight reduction. Automobile made of aluminum alloy can be given lighter, stronger and a harder surface by anodizing than one made of steel-alloy. In this paper, we investigate the influence of lap length, adherend thickness and adhesive thickness on adhesive strength of single-lap adhesive joints by conducting tensile-shear tests. Single-lap adhesive joints of aluminum was calculated using joint factor by using adhesive length, adherend thickness of specimen.

  • PDF

유지형태와 접착제 종류에 따른 수지 접착형 수복물과 법랑질간의 전단결합강도 및 파절양상에 관한 연구 (A STUDY ON THE SHEAR BOND STRENGTH BETWEEN RESIN-BONDED RETAINERS AND ENAMEL ACCORDING TO THE ADHESIVE RESINS AND RETENTION TYPES)

  • 조미숙;양재호
    • 대한치과보철학회지
    • /
    • 제33권4호
    • /
    • pp.662-684
    • /
    • 1995
  • The purpose of this study was to evaluate the shear bond strength between various resin-bonded retainers and enamel according to the adhesive resins and retention types and observe the bond filure modes with scanning electron microscope(SEM). For this purpose, the followin eight sub-groups were tested in shear bond strength : 1) electrochemically etched group(Verabond) using Panavia EX and Superbond C&B 2) tin-plated group(PG-S) using Panavia EX and Superbond C&B 3) salt-treated group(Verabond) using Panavia EX and Superbond C&B 4) meshtreated group(Verabond) using Panavia EX and Superbond C&B. Thermocycling test was conducted on the condition of 15 second dwell time each in $5^{\circ}C$ and $55^{\circ}C$bath. Shear bond strength was measured by Instron Universal Testing Machine(medel 1125). The obtained results were as follows : 1. After thermocycling, the shear bond strengths of tin-plated group and electrochemically etched group were significantly greater than those of salt-treated group and mesh-treated group. And the shear bond strength of Panavia EX was greater than that of Superbond C&B with salt-treated group and tin-plated group(p<0.05). 2. Before thermocycling, electrochemically etched group using Superbond C&B produced the greatest shear bond strength(p<0.01). 3. The shear bond strength of electrochemically etched group using Superbond C&B was significantly decreased after thermocycling(p<0.01). 4. In observation of bond failure modes before thermocycling, Panavia EX highly exhibited enamel fracture. Tin-plated group using Superbond C&B adhesive failure between metal and resin and electrochemically etched group using Superbond C&B exhibited adhesive failure between enamel and rdsin. 5. In observation of failure modes after thermocycling, Panavia EX exhibited cohesive failure and Superbond C&B exhibited adhesive failure between resin and metal.

  • PDF

Influence of the Adhesive, the Adherend and the Overlap on the Single Lap Shear Strength

  • da Silva, Lucas F.M.;Ramos, J.E.;Figueiredo, M.V.;Strohaecker, T.R.
    • 접착 및 계면
    • /
    • 제7권4호
    • /
    • pp.1-9
    • /
    • 2006
  • The single lap joint is the most studied joint in the literature in terms of both theory and practice. It is easy to manufacture and the lap shear strength is a useful value for strength assessment and quality control. Simple design rules exist such as the one present in standard ASTM 1002 or in a recent paper by Adams and Davies. The main factors that have an influence on the lap shear strength are the type of adhesive, i.e. ductile or brittle, the adherend yield strength and the overlap length. The overlap increases the shear strength almost linearly if the adhesive is sufficiently ductile and the adherend does not yield. For substrates that yield, a plateau is reached for a certain value of overlap corresponding to the yielding of the adherend. For intermediate or brittle adhesives, the analysis is more complex and needs further investigation. In order to quantify the influence of the adhesive, the adherend and the overlap on the lap shear strength, the experimental design technique of Taguchi was used. An experimental matrix of 27 tests was designed and each test was repeated three times. The influence of each variable could be assessed as well as the interactions between them using the statistical software Statview. The results show that the most important variable on the lap shear strength is the overlap length followed by the type of adherend.

  • PDF

Direct Shear Test of Retrofit Anchors Using Deformed Reinforcement and Adhesive

  • Choi, Dong-Uk;Kim, Yong-Gon
    • KCI Concrete Journal
    • /
    • 제12권1호
    • /
    • pp.91-99
    • /
    • 2000
  • A new type of retrof=t anchor bolt that uses deformed reinforcing bars and a commercial adhesive was developed and then an experimental study was carried out to determine the behavior of the anchors in direct shear. The steel-to-concl몫ete interface was tested. Plain concrete slabs with about 20-MPa compressive strength were used for 23 direct shear tests performed Test variables were anchor diameters (D16, D22. and D29) and edge effect. Three different shear tests were completed: simple shear, edge shear where anchors were pulled against the concrete core, and edge shear where anchors were pushed against the concrete cover In the simple and the edge shear tests where the anchors were pulled against the core, the theoretical dowel strength determined by (equation omitted) was achieved but with relatively large displacements. The shear resistances increased with the increasing displacements. In the edge shear test where the anchors were pushrd against the cover, the peak shear strengths signif=cantly lower than the theoretical dowel strength were determined due to cracks developed in concrete when the edge distance was 80 mm. The peak strengths were about 50% of the dowel strength for Dl6 bar. and about 25% or less of the dowel strength for D22 and D29 bars. Test results revealed that the edge shear where the anchor was pushed against the cover controled.

  • PDF

Thermal Cycling에 따른 자가중합 레진의 결합강도에 관한 연구 (THE EFFECTS OF THERMAL CYCLING ON THE BOND STRENGTH OF SELF-CURING RESIN)

  • 조혜원;하점임
    • 대한치과보철학회지
    • /
    • 제35권4호
    • /
    • pp.697-705
    • /
    • 1997
  • The purpose of this study was to evaluate the effects of two metal adhesive primers on the shear bond strengths of self-curing resin to Ni-Cr a]toy and the effects of 1000 thermal cycling on the durability of the bond. The two selected metal adhesive primers were Metal Primer II(G-C corp., Japan) and MR Bond(Tokuyama corp., Japan) and no treatment groups were used as control. All specimens were divided into two groups according to thermal cycling. In the group without thermal cycling, the specimens were stored in water for 24 hours. In the group with thermal cycling, the specimens were thermocycled 1000 times at temperature of $5^{\circ}C\;and\;55^{\circ}C$. Shear bond strengths were measured using the Universal testing machine(Zwick 145641, Germany) with a crosshead speed of 0.5 mm/min. The results were as follows: 1. MR Bond significantly improved the shear bond strength of resin to Ni-Cr alloy before and after thermal cycling. 2. There were no difference in the shear bond strength of resin to Ni-Cr alloy between Metal Primer II treated group and no treatment group. 3. Regardless of the type and the use of adhesive primers, there were tendency of decrease in shear bond strength with 1000 thermal cycling.