• 제목/요약/키워드: Adhesive patterns

검색결과 111건 처리시간 0.024초

원자현미경을 이용한 생체물질의 접착력 측정기술 개발 (Novel measuring technique for biological adhesion forces using AFM)

  • 김성주;문원규;전종협
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2005년도 춘계학술대회 논문집
    • /
    • pp.641-644
    • /
    • 2005
  • The study on the interaction forces of some biological materials is important to understanding biological phenomena and their application to practical purpose. This paper introduces a measuring technique for biological adhesive forces using the AFM(Atomic Force Microscope). Since no standardized thesis on adhesive forces exist, the adhesive forces is defined as adhesive forces against a hardened surface of biological materials. To grant the results are meaningful, which is based on the understanding the surface characteristics of biological materials using the AFM, a nominal value of average adhesive force per unit area should be measured. Therefore the modified AFM probe with small micro glass bead was proposed so that it can guarantee the required contact area for measuring the average adhesive forces. A pyrex glass substrate with circular patterns, which was fabricated by micromachining technique, is introduced in order to controll the contact area. The two types of mussel adhesive proteins, Celltak and recombinant-MGFP5, were tested by the proposed measuring method. The test results show that the adhesive force of the mussel adhesive proteins can be reliably measured by use of this method.

  • PDF

타액에 오염된 상아질에 대한 콤포머의 접합양상 (THE ADHESIVE PATTERNS OF COMPOMER TO SALIVA-CONTAMINATED DENTIN)

  • 조영곤;김병태;이석종
    • Restorative Dentistry and Endodontics
    • /
    • 제25권4호
    • /
    • pp.575-586
    • /
    • 2000
  • In this study, adaptation of compomer to saliva contaminated dentin was evaluated with scanning electron microscope(SEM) and confocal laser scanning microscope(CLSM). For the SEM study, the occulusal surfaces of thirty two molar teeth were grounded to exposure dentin surfaces. The specimen were randomly assigned to control and three experimental groups with four samples in each group. In control group, Dyract and F-2000 compomer were bonded on the specimens according to the manufactures direction. Experimental groups were subdivided into three groups. They were contaminated with saliva on dentin surfaces ; Experimental group 1 : Saliva was dried with compressed air. Experimental group 2 : Saliva was rinsed with air-water spray and dried. Experimental group 3 : After polymerization of an adhesive, they were contaminated with saliva, and then saliva was rinsed with air-water spray and dried. Dyract and F-2000 compomer were bonded on saliva-treated dentin surfaces. The interfaces between dentin and compomer were observed with SEM. For the CLSM study, Class V cavities were prepared in buccal and ligual surfacess of thirty two molars. The specimens were divided into control and experimental groups. Class V cavities in experimental group were contaminated with saliva and those surfaces in each experimental groups received the same treatments as for the SEM study. Cavities were applied Prime & Bond 2.1 and F-2000 compomer primer/adhesive that were mixed with fluorescein, and then were filled with Dyract and F-2000 compomer. Specimens were embedded in transparent acrylic resin and sectioned buccolingual1y with diamond wheel saw, and then mounted on cover slide for CLSM study. The interface between cavity and compomer was observed by fluoresence imaging with a CLSM. The results were as follows : 1. In SEM exammination of Dyract group, control group, experimental group 2, 3 showed close adaptation to dentin and hybrid layer of $3{\sim}4{\mu}m$ diameter. Interfacial gap between compomer and dentin in experimental group 1 was wider than in control group. 2. In SEM examination of F-2000 group, adaptation to dentin of control group was closer than Dytact control group, but hybrid-like layer was not observed. Interfacial gap between compomer and dentin in experimental group 1 was wider than in Dyract experimental group 1. 3. In dissolution specimens of Dyract and F-2000 group, resin tags penetrated through dentinal tubules in control group and experimental group 1 and 3, but the penetration of resin tag was irregular and partial in experimental group 1. 4. In CLSM exammination of Dyract and F-2000 group, adhesive patterns of control and experimental groups showed same as in SEM. This result suggests the treatment methods, rinsing & drying, repeating all adhesive procedures, will produce good effect on adaptation of compomer to dentin if the dentin surface or polymerized adhesive is contaminated by saliva.

  • PDF

Self-etching Primer를 이용한 교정용 브라켓 부착시 전단결합강도와 파절양상에 관한 비교연구 (A comparative study on bond strength and adhesive failure pattern in bracket bonding with self-etching primer)

  • 김유경;이진우;차경석
    • 대한치과교정학회지
    • /
    • 제34권4호
    • /
    • pp.325-332
    • /
    • 2004
  • 본 연구의 목적은 산부식과 전처리 과정을 결합하여 접착 단계를 단순화시킨 self-etching primer의 임상적인 유용성 을 판단하고자, self-etching primer로 브라켓을 접착하는 방법과 기존의 $37\%$ 인산으로 부식하여 접착하는 방법을 사용하여, 광중합시 사용되는 광원 및 브라켓 종류에 따른 전단결합강도와 접착파절양상에 관하여 비교 연구하는 것이다. 사람의 상하악 소구치를 포매하여 만든 시편을 부식 및 전처리 방법에 따라 각각 $37\%$ 인산으로 산부식 후 Transbond XT primer를 사용하여 접착한 군과 Transbond Plus self-etching primer를 사용하여 접착한 군으로, 광원 종류에 따라 가시광선과 plasma arc light을 이용하여 중합한 군으로 나누었고, 브라켓 종류에 따라 금속브라켓과 세라믹 브라켓을 사용하여 접착한 군으로 분류하여 각 군간의 전단결합강도와 접착파절양상을 관찰하여 다음과 같은 결과를 얻었다. 1. 광원과 브라켓 종류가 동일한 조건일 때, self-etching primer를 사용하여 접착한 군과 XT primer를 사용하여 접착한 군간의 전단결합강도는 통계적으로 유의한 차가 없었다. 2. 금속브라켓을 접착한 경우, 광원과 부식 및 전처리 방법에 따른 전단결합강도는 통계적으로 유의한 차가 없었다. 3. Self-etching primer와 XT primer를 사용하여 접착한 군 모두에서 세라믹 브라켓을 사용하여 접착한 군의 전단결합 강도는 금속브라켓을 사용하여 접착한 군보다 통계적으로 유의하게 컸다(p<0.001). 4. 접착제 잔류지수는 self-etching primer를 사용하여 접착한 군과 XT primer를 사용하여 접착한 군에서 통계적인 유의한 차가 없었으며, 세라믹 브라켓을 사용하여 접착한 군에서 금속브라켓을 사용하여 접착한 군보다 유의하게 커서, 법랑질-레진 접착 계면 부위의 파절이 더 많은 것으로 나타났다. 이상의 결과로 미루어 보아 Transbond Plus self-etching primer를 사용하여 브라켓을 접착하는 것은 적절한 결합강도를 얻으면서도 사용이 간편하고 시술 시간을 단축시킬 수 있으므로 임상적으로 유용할 것으로 판단된다.

단면형상에 따른 단일겹치기 이음의 피로 및 정적 토크 전달특성에 관한 실험적 연구 (Effect of the Cross Sectional Shapes on the Static and Fatigue Torque Transmission Capabilities of Adhesive Single Lap Joints)

  • 최진경;이대길
    • 대한기계학회논문집
    • /
    • 제18권4호
    • /
    • pp.835-845
    • /
    • 1994
  • In this paper, the effects of the adhesive thickness and adherend roughness on the static and fatigue strengths of the adhesively bonded circular single lap joints has been investigated by an experimental method. The stacking sequence effect of the composite adherend on the static and fatigue strength and the fracture patterns of the adhesive failure were also observed. Since the circular single lap joint fails catastrophically beyond the static strength of fatigue limit, the tubular polygonal adhesively bonded joints such as triangular, tetragonal, pentagonal, hexagonal as well as elliptical joints were manufactured in order to give partial mechanical characteristics to the adhesively bonded tubular joints. These joints were tested both in static and fatigue modes. From the experimental investigations, it was found that the fatigue strength of the circular adhesively bonded joints was much dependent on the arithmetical average surface roughness of the adherends and the polygonal adhesively bonded joints had better fatigue strength characteristics than the circular adhesively bonded joints.

A STUDY ON THE ADHESION OF A SOFT LINER CONTAINING 4-META TO THE BASE METAL ALLOY AND ITS VISCOELASTIC PROPERTY

  • Park Hyun-Joo;Kim Chang-Whe;Kim Yung-Soo
    • 대한치과보철학회지
    • /
    • 제41권6호
    • /
    • pp.732-746
    • /
    • 2003
  • Statement of problem. Soft lining materials, also referred to as tissue conditioning materials, tissue heating materials, relining materials, soft liners or tissue conditioners, were first introduced to dentistry by a plastic manufacturer in 1959. Since the introduction of the materials to the dental field, their material properties have been continually improved through the effort of many researchers. Soft lining materials have become widely accepted, particularly by prosthodontists, because of their numerous clinical advantages and ease of manipulation. Unfortunately, few reports have been issued upon the topic of increasing the bond strength between the base metal alloy used in cast denture bases and PMMA soft liner modified with 4-META, nor upon the pattern of debonding and material change in wet environment like a intra oral situation. Purpose. The purposes of this study were comparing the bond strength between base metal alloy used for the cast denture bases and PMMA soft liner modified with 4-META, and describing the pattern of debonding and material property change in wet environment like the intraoral situation. Material and Methods. This study consisted of four experiments: 1. The in vitro measurement of shear bond strength of the adhesive soft liner. 2. The in vitro measurement of shear bond strength of the adhesive soft liner after 2 weeks of aging. 3. A comparison of debonding patterns. 4. An evaluation the Relation time of modified soft liner. The soft liner used in this study was commercially available as Coe-soft (GC America.IL.,USA), which is provided in forms of powder and liquid. This is a PMMA soft liner commonly used in dental clinics. The metal primer used in this study was 4-META containing primer packed in Meta fast denture base resin (Sun Medical Co., Osaka, Japan). The specimens were formed in a single lap joint desist which is useful for evaluating the apparent shear bond strength of adhesively bonded metal plate by tensile loading. Using the $20{\times}20mm$ transparent grid, percent area of adhesive soft liner remaining on the shear area was calculated to classify the debonding patterns. To evaluate the change of the initial flow of the modified adhesive soft liner, the gelation time was measured with an oscillating rheometer (Haake RS150W/ TC50, Haake Co., Germany). It was a stress control and parallel plate type with the diameter of 35mm. Conclusion. Within the conditions and limitations of this study, the following conclusions were drawn as follows. 1. There was significant increase of bond strength in the 5% 4-META, 10% 4-META containing groups and in the primer coated groups versus the control group(P<0.05). 2. After 2 weeks of aging, no significant increase in bond strength was found except for the group containing 10% 4-META (P<0.05). 3. The gelation times of the modified soft liner were 9.3 minutes for the 5% 4-META containing liner and 11.5 minutes for the 10% 4-META liner. 4. The debonding patterns of the 4-META containing group after 2 weeks of aging were similar to those of immediaely after preparation, but the debonding pattern of the primer group showed more adhesive failure after 2 weeks of aging.

PDMS와 고분자 전해질 표면을 이용한 간편한 세포 패터닝 방법 (Facile Cell Patterning Based on Selectively Patterned Polydimethylsiloxane (PDMS) and Polyelectrolyte Surface)

  • 정헌호;송환문;황예진;황택성;이창수
    • KSBB Journal
    • /
    • 제24권6호
    • /
    • pp.515-520
    • /
    • 2009
  • This study presented facile method of cell patterning using fabricated PDMS patterns on polyelectrolyte coated surface. This basic principle is the fabrication of functional surface presenting two orthogonal surfaces such as cell adhesive and repellent properties. Cell adhesive surface was firstly fabricated with simple coating of polyelectrolyte multilayer. And then, the desired patterns of PDMS for the prevention of nonspecific binding of cells were transferred onto the previously formed thin film of polyelectrolyte multilayer. Thus, we could prepare novel functional surface simultaneously containing PDMS and polyelectrolyte region. As expected, the PDMS regions showed effective prevention of nonspecific binding of cell and the other region, exposed polyelectrolyte area, provided cell adhesive environment. The height of formed PDMS structure was about 100 nm. Based on this method, cell patterning can be successfully obtained with various pattern shapes and sizes. Therefore, we expect that this simple method will be useful platform technology for the development of cell chip, cell based assay system, and biochip.

Evaluation of Patterns and Binding Forces of Tablets in Dissolution Processes

  • Kim, Jung-Woo
    • Journal of Pharmaceutical Investigation
    • /
    • 제15권2호
    • /
    • pp.45-52
    • /
    • 1985
  • For the model tablets using mannitol and Avicel PH 101 as excipients, the patterns of disintegration and dissolution from the differences of physical properties were investigated. It was found that the patterns in the dissolution and binding forces in the interaction of materials by estimates of solid-solid or liquid surface free energy due to cohesive or adhesive properties of materials, and solid surface free energy in binding forces of tablet should be considered as an important factor in dissolution processes.

  • PDF

알루미늄-에폭시-알루미늄 접착판에서 에폭시 두께 검사를 위한 유도초음파 수치시뮬레이션 (Numerical Simulation of Guided Ultrasonic Waves for Inspecting Epoxy Thickness in Aluminum-Epoxy-Aluminum Adhesive Plates)

  • 이주원;나원배
    • 한국해양공학회지
    • /
    • 제23권6호
    • /
    • pp.117-123
    • /
    • 2009
  • This paper presents a numerical simulation of guided ultrasonic waves propagating in aluminum-epoxy-aluminum adhesive plates. In particular, this study investigated the effect of the epoxy thickness on the dispersive patterns, such as the phase velocity and group velocity of guided ultrasonic waves. In addition to investigating the dispersive curves, a numerical simulation using the pulse-echo method was carried out. This simulation showed that the degree of sensitivity of the epoxy thickness is dependent on the curvature of the phase and group dispersion curves, the maximum amplitude of the received time signals, and the peak frequency of the real components of the Fourier transform. Then, the linear relations between the epoxy thickness and the received and transformed signals were constructed to estimate the epoxy thickness.

이종골 이식시 Fibrin adhesive의 사용이 골 재생에 미치는 영향에 관한 조직병리학적 연구 (A Histo-Pathological Study of Effect on Bone Regeneration with Fibrin Adhesive)

  • 고영우;임성빈;정진형;이종헌
    • Journal of Periodontal and Implant Science
    • /
    • 제33권1호
    • /
    • pp.91-102
    • /
    • 2003
  • Several effective treatment methods and materials have been developed for the treatment of furcation involvement. Currently, the combination of guided tissue regeneration (GTR) and bone grafts is the most commonly prescribed method of treating furcation involved defects. But because these cases often present with poor accessibility, placement of the membrane may be difficult and consequently, clinically impractical. In this study, the alveolar bone healing patterns of adult beagle dogs presenting with alveolar bone destruction treated by one of two methods - treatment using solely bone allografts (BBP(R)), or treatment using bone allografts (BBP(R)) stabilized by a fibrin adhesive - were comp ared. The effects of the fibrin adhesive on the initial stabilization of the newly formed bone, subsequent regeneration of bone, and the feasibility of the clinical application of the fibrin adhesive were analyzed. The results of the study were as follows: 1. Clinical signs of inflammation at the 4-8 week interval were not observed: but signs of mild inflammation were histologically observed at the 4-week interval. 2. Allografts stabilized by fibrin adhesive showed good bone formation, whereas defects treated with only the allograft material showed incomplete alveolar bone regeneration. 3. Allografts stabilized by fibrin adhesive showed a decrease in the amount old bone with a concurrent increase in the formation of new lamellar bone four weeks post-op, whereas defects treated with only the allograft material showed no new lamellar bone formation at the same interval. 4. In detects treated with only the allograft material, the defective area was filled with connective tissue 8-weeks post-op, whereas fibrin adhesive stabilized allografts showed viable connections between the original bone and the newly formed bone, in addition to neovascularization 8-weeks post-op. The results of this study show that concurrent use of fibrin adhesive materials can stabilize the allograft material and aid in new bone formation Although the stability of fibrin adhesives fall short of the results achievable by GTR membranes, in cases presenting with poor accessibility that contraindicate the use of membranes, fibrin adhesive materials provide a viable and effective alternative to graft stabilization and new bone formation.