• Title/Summary/Keyword: Adhesive method

Search Result 827, Processing Time 0.025 seconds

Characteristics Influencing the Occurrence of Respiratory Medical Device-related Pressure Ulcers in the Pediatric Intensive Care Unit (소아중환자실 환아의 호흡기계 의료장치 관련 욕창 발생 관련 특성)

  • Kim, Hae-kyung;Kim, Younghae;Son, Hyun-Mi
    • Child Health Nursing Research
    • /
    • v.25 no.2
    • /
    • pp.133-142
    • /
    • 2019
  • Purpose: This prospective study was conducted to determine the incidence and related characteristics of respiratory medical device-related pressure ulcers (MDRPU) in children admitted to a pediatric intensive care unit (PICU). Methods: The participants were 184 children who were admitted to the PICU of P University Hospital from April 2016 to January 2017. Data were collected on the occurrence of respiratory MDRPU and characteristics regarding the application of respiratory medical devices. Results: Respiratory MDRPU occurred in 11.9% of participants (58.3%: stage I ulcers, 37.5%: mucosal ulcers). The devices associated with respiratory MDRPU were endotracheal tubes (54.2%), high-flow nasal cannulas (37.5%), and oximetry probes (8.3%). Respiratory MDRPU associated with an endotracheal tube were significant differences according to the site and strength of fixation, the use of a bite block and adhesive tape, skin dryness, and edema. In high-flow nasal cannulas, significant differences were found according to the site of fixation, immobility after fixation, and skin dryness. Conclusion: The occurrence of respiratory MDRPU is significantly affected by the method and strength of fixation, as well as skin dryness and edema. Therefore, appropriate consideration of these factors in nursing care can help prevent respiratory MDRPU.

Analysis on an improved resistance tuning type multi-frequency piezoelectric spherical transducer

  • Qin, Lei;Wang, Jianjun;Liu, Donghuan;Tang, Lihua;Song, Gangbing
    • Smart Structures and Systems
    • /
    • v.24 no.4
    • /
    • pp.435-446
    • /
    • 2019
  • The existing piezoelectric spherical transducers with fixed prescribed dynamic characteristics limit their application in scenarios with multi-frequency or frequency variation requirement. To address this issue, this work proposes an improved design of piezoelectric spherical transducers using the resistance tuning method. Two piezoceramic shells are the functional elements with one for actuation and the other for tuning through the variation of load resistance. The theoretical model of the proposed design is given based on our previous work. The effects of the resistance, the middle surface radius and the thickness of the epoxy adhesive layer on the dynamic characteristics of the transducer are explored by numerical analysis. The numerical results show that the multi-frequency characteristics of the transducer can be obtained by tuning the resistance, and its electromechanical coupling coefficient can be optimized by a matching resistance. The proposed design and derived theoretical solution are validated by comparing with the literature given special examples as well as an experimental study. The present study demonstrates the feasibility of using the proposed design to realize the multi-frequency characteristics, which is helpful to improve the performance of piezoelectric spherical transducers used in underwater acoustic detection, hydrophones, and the spherical smart aggregate (SSA) used in civil structural health monitoring, enhancing their operation at the multiple working frequencies to meet different application requirements.

Imperceptible On-Skin Sensor Devices for Musculoskeletal Monitoring and Rehabilitation (상시 근골격 모니터링과 재활을 위한 온스킨 센서 디바이스 기술)

  • Park, C.W.;Koo, J.B.;Jin, H.;Kim, Y.;Lim, C.;Hong, C.H.;Kim, H.J.
    • Electronics and Telecommunications Trends
    • /
    • v.37 no.2
    • /
    • pp.30-41
    • /
    • 2022
  • As the society is superaging, the number of patients with movement disabilities due to musculoskeletal or nervous system illness is rapidly increasing. To improve public health and reduce medical expenses, it is essential to develop rehabilitation systems that allow patients to resume their daily-life activities. However, the existing musculoskeletal illness diagnosis and rehabilitation method is limited in terms of precision and efficiency because it is based on an empirical diagnosis and prescription without regard for individual characteristics. To overcome these limits, it is critical to design a novel concept of routine rehabilitation therapy device that is capable of inducing musculoskeletal balance by the precise analysis of musculoskeletal usage patterns via the motion and the muscle activity tracking of linked muscles. This study introduces the trend of on-skin sensor device technology for routine musculoskeletal monitoring and therapy. For on-skin rehabilitation systems, skin-adhesive and stretchable motion/posture, electromyography, pressure sensors, small-size and low-power wireless sensor interfaces, and user-friendly rehabilitation contents based on new algorithms are combined.

Study of Pd Target Power Effects on Physical Characteristics of Pd-Doped Carbon Thin Films Using Dual Magnetron Sputtering Method (듀얼 마그네트론 스퍼터링 법으로 제조된 Pd-Doped Carbon 박막의 물리적 특성에서 Pd 타겟 전력의 영향에 대한 연구)

  • Choi, Young-Chul;Park, Yong Seob
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.35 no.5
    • /
    • pp.488-493
    • /
    • 2022
  • Generally, diamond-like carbon films (a-C:H, DLC) have been shown to have a low coefficient of friction, a high hardness and a low wear rate. Pd-doped C thin film was fabricated using a dual magnetron sputtering with two targets of graphite and palladium. Graphite target RF power was fixed and palladium target RF power was varied. The structural, physical, and surface properties of the deposited thin film were investigated, and the correlation among these properties was examined. The doping ratio of Pd increased as the RF power increased, and the surface roughness of the thin film decreased somewhat as the RF power increased. In addition, the hardness value of the thin film increased, and the adhesive strength was improved. It was confirmed that the value of the contact angle indicating the surface energy increases as the RF power increases. It was concluded that the increase in RF power contributed to the improvement of the physical properties of Pd-doped C thin film.

Effect of the composite patch beveling on the reduction of stresses in 2024-T3 Aluminum structure damaged and repaired by composite, hybrid patch repair

  • Belhoucine, A.;Madani, K.
    • Structural Engineering and Mechanics
    • /
    • v.82 no.1
    • /
    • pp.17-30
    • /
    • 2022
  • The use of composite patches for the reduction of stresses at the level of the damaged zone in aeronautical structures has experienced rapid expansion given its advantages over conventional mechanical processes (riveting, bolting, etc.). Initially, The research axes in this field were aimed at choosing suitable mechanical properties for the composite and the adhesive, then to optimize the shape of the composite patch in order to ensure good load transfer and avoid having a debonding at the level of the edges essentially for the case of a repair by single side where the bending moment is present due to the non-symmetry of the structure. Our work falls within this context; the objective is to analyze by the finite element method the fracture behavior of a damaged plate repaired by composite patch. Stress reduction at the edge is accomplished by creating a variable angle chamfer on the composite patch. The effects of the crack length, the laminate sequence and the nature of the patch as well as the use of a hybrid patch were investigated. The results show clearly that a beveled patch reduces the stress concentrations in the damaged area and even at its edges. The hybrid patch also ensures good durability of the repair by optimizing its stacking sequence and the location of the different layers according to the fibers orientations.

Characteristics of Hybrid Protective Materials with CNT Sheet According to Binder Type

  • Jihyun Kwon;Euisang Yoo
    • Elastomers and Composites
    • /
    • v.57 no.4
    • /
    • pp.197-204
    • /
    • 2022
  • Recently, the demand has increased for protective clothing materials capable of shielding the wearer from bullets, fragment bullets, knives, and swords. It is therefore necessary to develop light and soft protective clothing materials with excellent wearability and mobility. To this end, research is being conducted on hybrid design methods for various highly functional materials, such as carbon nanotube (CNT) sheets, which are well known for their low weight and excellent strength. In this study, a hybrid protective material using CNT sheets was developed and its performance was evaluated. The material design incorporated a bonding method that used a binder for interlayer combination between the CNT sheets. Four types of binders were selected according to their characteristics and impregnated within CNT sheets, followed by further combination with aramid fabric to produce the hybrid protective material. After applying the binder, the tensile strength increased significantly, especially with the phenoxy binder, which has rigid characteristics. However, as the molecular weight of the phenoxy binder increased, the adhesive force and strength decreased. On the other hand, when a 25% lightweight-design and high-molecular-weight phenoxy binder were applied, the backface signature (BFS) decreased by 6.2 mm. When the CNT sheet was placed in the middle of the aramid fabric, the BFS was the lowest. In a stab resistance test, the penetration depth was the largest when the CNT sheet was in the middle layer. As the binder was applied, the stab resistance improvement against the P1 blade was most effective.

Preliminary Study for Vision A.I-based Automated Quality Supervision Technique of Exterior Insulation and Finishing System - Focusing on Form Bonding Method - (인공지능 영상인식 기반 외단열 공법 품질감리 자동화 기술 기초연구 - 단열재 습식 부착방법을 중심으로 -)

  • Yoon, Sebeen;Lee, Byoungmin;Lee, Changsu;Kim, Taehoon
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2022.04a
    • /
    • pp.133-134
    • /
    • 2022
  • This study proposed vision artificial intelligence-based automated supervision technology for external insulation and finishing system, and basic research was conducted for it. The automated supervision technology proposed in this study consists of the object detection model (YOLOv5) and the part that derives necessary information based on the object detection result and then determines whether the external insulation-related adhesion regulations are complied with. As a result of a test, the judgement accuracy of the proposed model showed about 70%. The results of this study are expected to contribute to securing the external insulation quality and further contributing to the realization of energy-saving eco-friendly buildings. As further research, it is necessary to develop a technology that can improve the accuracy of the object detection model by supplementing the number of data for model training and determine additional related regulations such as the adhesive area ratio.

  • PDF

Sound Absorption of Natural Fiber Composite from Sugarcane Bagasse and Coffee Silver Skin

  • Wachara KALASEE;Putipong LAKACHAIWORAKUN;Visit EAKVANICH;Panya DANGWILAILUX
    • Journal of the Korean Wood Science and Technology
    • /
    • v.51 no.6
    • /
    • pp.470-480
    • /
    • 2023
  • This study aimed to develop a sound-absorbing composite using sugarcane bagasse (SB) and coffee silver skin (CS) as raw materials. The composite boards were manufactured by bonding the fibers with Melamine Urea-Formaldehyde adhesive, ensuring a consistent thickness of 30 mm. Various densities were employed, namely 380, 450, and 520 kg/m3. The samples were fabricated with different fiber ratios, including SB100%, SB75% with CS25%, and SB50% with CS50%. The sound absorption coefficient (SAC) and noise reduction coefficient (NRC) were measured using the impedance tube method within a frequency range of 63-6,300 Hz. The experimental results revealed that the mixing ratio of CS exerted a notable influence on enhancing the SAC, while the density of the composite board exhibited a significant impact on increasing both the SAC and NRC. Among the densities tested, the optimal value was observed at 520 kg/m3, yielding a SAC value of 0.65 at a frequency of 1,000 Hz and an NRC value of 0.55 for the SB50-CS50 composite plate. These findings underscore the importance of considering the CS mixing ratio and composite board density when aiming to optimize sound absorption properties.

Evaluation of Cumulative and Conditional Antibiotic Release from Vancomycin-Embedded Fibrin Sealant and Its Antibacterial Activity : An In Vitro Study

  • Shin, Dong-Won;Sohn, Moon-Jun;Cho, Chong-Rae;Koo, Hae-won;Yoon, Sang Won
    • Journal of Korean Neurosurgical Society
    • /
    • v.63 no.1
    • /
    • pp.45-55
    • /
    • 2020
  • Objective : Fibrin sealants have been used for hemostasis, sealant for cerebrospinal fluid leakage, and adhesive barrier in neurosurgery. Further, as its clinical use and role of an effective drug delivery vehicle have been proposed. This study was performed to measure antibacterial activity and continuous local antibiotic release from different concentrations of vancomycin-impregnated fibrin sealant in vitro. Methods : Antibacterial activity was investigated by disk diffusion test by measuring the diameter of the growth inhibition zone of bacteria (methicillin-resistant Staphylococcus aureus, ATCC29213) from vancomycin-embedded fibrin sealant disc diluted at five different concentrations (C1-C5; 8.33, 4.167, 0.83, 0.083, and 0.0083 mg/disc, respectively). Continuous and conditioned release of vancomycin concentration (for 2 weeks and for 5 days, respectively) were also measured using high-performance liquid chromatography (HPLC) method. To mimic the physiologic wound conditions with in vitro, conditioned vancomycin release in phosphate buffer solution (PBS) was measured and replaced PBS for five consecutive days, half a day or completely daily. Results : In the disk diffusion test, the mean diameters of bacterial inhibition zone were 2.54±0.07 cm, 2.61±0.12 cm, and 2.13±0.15 cm (C1, C2, and C3 respectively) but 1.67±0.06 cm and 1.23±0.15 cm in C4 and C5, respectively. Continuous elution test elicited the peak release of vancomycin from the fibrin sealant at 48 hours, with continued release until 2 weeks. However, conditioned vancomycin release decreased to half or more on day 2, however, the sustainable release was measured over the therapeutic dose (10-20 ㎍/mL) for 5 days and 4 days in assays of half and total exchange of PBS. Conclusion : This study suggests that fibrin sealant can provide an efficient vehicle for antibiotic drug release in a wide range of neurosurgical procedures and the safe and effective therapeutic dose will be at the concentration embedded of 4.167 mg/disc or more of vancomycin.

The Effect of Surface Treat`ment on Bond Strength of Polycarbonate Bracket (폴리카보네이트 브라켓 부착 시 결합강도 증진을 위한 표면처리 효과)

  • Kim, Seok-Pil;Kim, Nyeon-Kyeong;Lee, Hyun-Jung;Hwang, Hyeon-Shik
    • The korean journal of orthodontics
    • /
    • v.36 no.5
    • /
    • pp.331-338
    • /
    • 2006
  • Objective: The purpose of this study was to evaluate whether the bond strength of polycarbonate brackets can be increased through surface treatment. Methods: One hundred polycarbonate brackets (Alice) were bonded to bovine incisors with light-cured adhesive. The bracket bases were treated with one of three methods; sandblasting, plastic conditioner application, and combined treatment with sandblasting and plastic conditioner. The brackets without any suraace treatment served as the control. The shear bond strength was tested with a universal testing machine, and failure pattern was assessed with the adhesive remnant index. Results: The shear bond strength in all experimental groups was higher than that of the control group (p < 0.001). The group treated with plastic conditioner after sandblasting showed statistically higher shear bond strength than the sandblasting only group to (p < 0.05). The group treated with plastic conditioner after sandblasting showed higher shear bond strength than plastic conditioner only group, but the difference was not statistically significant. Conclusion: The above results suggest that the surface treatments of polycarbonate bracket is mandatory to improve bond strength, and the most effective method is an application of plastic conditioner after sandblasting.