• Title/Summary/Keyword: Adhesive method

Search Result 827, Processing Time 0.031 seconds

Effect of irrigation protocols on smear layer removal, bond strength and nanoleakage of fiber posts using a self-adhesive resin cement

  • Rodrigo Stadler Alessi;Renata Terumi Jitumori ;Bruna Fortes Bittencourt;Giovana Mongruel Gomes ;Joao Carlos Gomes
    • Restorative Dentistry and Endodontics
    • /
    • v.48 no.3
    • /
    • pp.28.1-28.13
    • /
    • 2023
  • Objectives: This study aimed to investigate the effect of the application method of 2% chlorhexidine (CHX) and its influence on the adhesion of fiberglass posts cemented with a self-adhesive resin cement. Materials and Methods: Sixty human mandibular premolars were endodontically treated and divided into 5 groups (n = 12), according to the canal irrigant and its application method: 2 groups with conventional syringe irrigation (CSI)-2.5% sodium hypochlorite (NaOCl) (control) and 2% CHX- and 3 groups with 2% CHX irrigation/activation-by passive ultrasonic irrigation (PUI), Easy Clean file, and XP-Endo Finisher file. Two roots per group were evaluated for smear layer (SL) removal by scanning electron microscopy. For other roots, fiber posts were luted using a self-adhesive resin cement. The roots were sectioned into 6 slices for push-out bond strength (BS) (7/group) and nanoleakage (NL) (3/group). Data from SL removal were submitted to Kruskal-Wallis and Student-Newman-Keuls tests (α = 0.05). Data from BS and NL were evaluated by 2-way analysis of variance and Tukey's test (α = 0.05). Results: For SL removal and BS, the CHX irrigation/activation promoted better values than CSI with CHX (p < 0.05), but it was not significantly different from CSI with NaOCl (p > 0.05). For NL, the lowest values were obtained by the chlorhexidine irrigation/activation groups (p < 0.05). Conclusions: Active 2% CHX irrigation can be used to improve the post space cleaning and adhesion before fiber post cementation with self-adhesive resin cements.

Design parameters on the tensile load bearing capacity of a co-cured lap joint with steel and carbon fiber/epoxy composite adherends (강철재료와 탄소섬유/에폭시 복합재료를 이용한 동시경화 조인트의 인장하중 전달용량에 미치는 설계변수에 관한 연구)

  • 신금철;이정주
    • Proceedings of the Korean Society For Composite Materials Conference
    • /
    • 2001.05a
    • /
    • pp.172-175
    • /
    • 2001
  • The co-cured Joining method, which is regarded as an adhesively bonded Joining method, is an efficient joining technique because both curing and bonding processes for the composite structures can be achieved simultaneously. It requires neither surface treatment onto the composite adherend nor an additional adhesive joining process because the excess resin, which is extracted from composite materials during consolidation, accomplishes the co-cured Joining process. Since the adhesive of the co-cured joint is the same material as the resin of the composite adherend, the analysis and design of the co-cured joint for composite structures are simpler than those of an adhesively bonded joint, which uses an additional adhesive. In this paper, effects of the manufacturing parameters, namely surface roughness, stacking sequence of the composite adherend, and manufacturing pressure in the autoclave during curing process, on the tensile load bearing capacity of the co-cured single lap joint will be experimentally investigated.

  • PDF

Facile Cell Patterning Based on Selectively Patterned Polydimethylsiloxane (PDMS) and Polyelectrolyte Surface (PDMS와 고분자 전해질 표면을 이용한 간편한 세포 패터닝 방법)

  • Jeong, Heon-Ho;Song, Hwan-Moon;Hwang, Ye-Jin;Hwang, Taek-Sung;Lee, Chang-Soo
    • KSBB Journal
    • /
    • v.24 no.6
    • /
    • pp.515-520
    • /
    • 2009
  • This study presented facile method of cell patterning using fabricated PDMS patterns on polyelectrolyte coated surface. This basic principle is the fabrication of functional surface presenting two orthogonal surfaces such as cell adhesive and repellent properties. Cell adhesive surface was firstly fabricated with simple coating of polyelectrolyte multilayer. And then, the desired patterns of PDMS for the prevention of nonspecific binding of cells were transferred onto the previously formed thin film of polyelectrolyte multilayer. Thus, we could prepare novel functional surface simultaneously containing PDMS and polyelectrolyte region. As expected, the PDMS regions showed effective prevention of nonspecific binding of cell and the other region, exposed polyelectrolyte area, provided cell adhesive environment. The height of formed PDMS structure was about 100 nm. Based on this method, cell patterning can be successfully obtained with various pattern shapes and sizes. Therefore, we expect that this simple method will be useful platform technology for the development of cell chip, cell based assay system, and biochip.

A new analytical approach for optimization design of adhesively bonded single-lap joint

  • Elhannani, M.;Madani, K.;Mokhtari, M.;Touzain, S.;Feaugas, X.;Cohendoz, S.
    • Structural Engineering and Mechanics
    • /
    • v.59 no.2
    • /
    • pp.313-326
    • /
    • 2016
  • In this study the three-dimensional nonlinear finite element method was used to analyze the stresses distribution in the adhesive layer used to joint two Aluminum 2024-T3 adherends. We consider in this study the effect of different parameters witch directly affect the values of different stresses. The experimental design method is used to investigate the effects of geometrical parameters of the single lap joint in order to achieve an optimization of the assembly with simple lap joint. As a result, it can be said that both the geometrical modifications of the adhesive and adherends edge have presented a significant effect at the overlap edge thereby causing a decrease in peel and shear stresses. In addition, an analytical model is also given to predict in a simple but effective way the joint strength and its dependence on the geometrical parameters. This approach can help the designers to improve the quality and the durability of the structural adhesive joints.

Comparison between Tissue Adhesive and Suture by Using Modified Hollander Score for Facial Wounds Treated in the Emergency Department (응급실 얼굴 열상 환자에서 Modified Hollander 점수에 의한 조직 접착제 사용과 봉합사를 이용한 봉합 후 결과 비교)

  • Hong, Suk-Ho;Yang, Young-Mo;Lee, Jang-Young;Lee, Won-Suk;Bark, Koung-Nam;Yang, Hee-Bum
    • Journal of Trauma and Injury
    • /
    • v.24 no.2
    • /
    • pp.143-150
    • /
    • 2011
  • Purpose: The object of this study is to compare the patient satisfaction in the view of scarring, cost, and hospital stay between the conventional suture method and a method using Histoacryl$^{(R)}$ (2-N-butylcyanoacrylate) adhesive for treating facial lacerations in the emergency department. Method: This study is a randomized prospective trial, which was conducted from December 2009 to January 2010. The participants include 109 patients who visited the emergency room in Deajon Eulji Medical Center. The ages ranged from 1 to 59 (mean age of 18.7), and all had facial lacerations of less than 3 cm. In order to treat the facial lacerations, an emergency medicine doctor used tissue adhesive (2-N-butylcyanoacrylate, Histoacryl$^{(R)}$) for 41 patients in the experimental group, and a plastic surgeon performed conventional suturing for 68 patients in the control group. The ER-stay and the primary treatment fee were compared in the two groups, and the scarring was evaluated 10 to 11 months from suturing by using the Modified Hollander Method and the 10-cm scaled VAS (visual analogue scale: score 0=no scar, score 10=very severe scar) Result: The ER stay was 76 minutes for the experimental group and 107 minutes for the control group, showing that statistically significantly less time of 31 minutes was taken in the experimental group. The cost of the experimental group was 40000 won (50.1%) more expensive than the control group, with an average cost of 121900 won for the experimental group and 81200 won for the control group. As for scar evaluation, 10.56 months after suturing, the experimental group showed a better result with a score of 2.6 compared to a score of 3.4 in the control group; however, this difference was not statistically significant ($p$ <0.05). As to a detailed evaluation of scar characteristics, the experimental group had a statistically significantly better result in scar elevation, with a score of 0.6 compared to a score of 1.65 for the control group. Conclusion: If appropriate patients are selected, the method using tissue adhesive directly applied by an EM doctor not only decreases ER stay but also creates similar patients satisfaction, with statistically better result in scar elevation, compared to the conventional suture method; thus, ultimately general patient satisfaction is increased.

Solvent-free UV-curable Acrylic Adhesives for 3D printer build sheet (3D 프린터 빌드시트용 무용제 UV 경화형 아크릴 점착제의 제조)

  • Lee, Bae Hwa;Park, Dong Hyup;Kim, Byung Jick
    • Journal of Adhesion and Interface
    • /
    • v.21 no.3
    • /
    • pp.93-100
    • /
    • 2020
  • 3D printing technology enables proper objects to be made through an additive manufacturing method, but resulting in dimension deviation of the product due to contraction phenomenon as cooling melted filament resin injected from high-temperature use environment. In this research, we studied on acrylic adhesives for 3D printer build sheet in order to fabricate high-quality products with a precise shape and to well-mount without distortion. The solvent-free UV-curable acrylic adhesive formulation was designed by adding 4-acryloylmorpholine (ACMO) with high adhesion, toughness, glass transition temperature so that adhesion properties are stable at high temperature and products are easily mounted/detached from the adhesives. The designed formulation was polymerized through two-steps using post-addition of monomers. Using this, the acrylic adhesive was coated to make a film and then analyzed using various experimental techniques. As a result, the fabricated adhesive exhibited high glass transition temperature and there was little gap in peel strength before and after thermal treatment. Moreover, it was confirmed by rheological analysis that this adhesive can provide great bonding/debonding ability without distortion. We demonstrated the fabrication of a rectangular product using a 3D printing method using our acrylic adhesive as a build sheet. Mounting ability and workability were satisfactory and dimension deviation of the product was tiny. Because the product is easily detachable from the acrylic adhesive developed here than conventional build sheets, it is expected that this will provide work convenience to users who use the 3D printer.

Evaluation of Adhesive Strength for Nano-Structured Thin Film by Scanning Acoustic Microscope (초음파 현미경을 이용한 나노 박막의 접합 강도 평가)

  • Park, Tae-Sung;Kwak, Dong-Ryul;Park, Ik-Keun;Miyasaka, Chiaki
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.32 no.4
    • /
    • pp.393-400
    • /
    • 2012
  • In recent years, nano-structured thin film systems are often applied in industries such as MEMS/NEMS device, optical coating, semiconductor or like this. Thin films are used for many and varied purpose to provide resistance to abrasion, erosion, corrosion, or high temperature oxidation and also to provide special magnetic or dielectric properties. Quite a number of articles to evaluate the characterization of thin film structure such as film density, film grain size, film elastic properties, and film/substrate interface condition were reported. Among them, the evaluation of film adhesive to substrate has been of great interest. In this study, we fabricated the polymeric thin film system with different adhesive conditions to evaluate the adhesive condition of the thin film. The nano-structured thin film system was fabricated by spin coating method. And then V(z) curve technique was applied to evaluate adhesive condition of the interface by measuring the surface acoustic wave(SAW) velocity by scanning acoustic microscope(SAM). Furthermore, a nano-scratch technique was applied to the systems to obtain correlations between the velocity of the SAW propagating within the system including the interface and the shear adhesive force. The results show a good correlation between the SAW velocities measured by acoustic spectroscope and the critical load measured by the nano-scratch test. Consequently, V(z) curve method showed potentials for characterizing the adhesive conditions at the interface by acoustic microscope.

Experimental and numerical study on the failure of sandwich T-joints under pull-off loading

  • Nguyen, Khanh-Hung;Park, Yong-Bin;Kweon, Jin-Hwe;Choi, Jin-Ho;Shul, Chang-Won;Yang, Myung-Seog;Jun, Seung-Moon
    • International Journal of Aeronautical and Space Sciences
    • /
    • v.13 no.2
    • /
    • pp.229-237
    • /
    • 2012
  • In this study, the failure mechanism of sandwich-to-laminate T-joints under pull-off loading was investigated by experiment and the finite element method. A total of 26 T-joint specimens were manufactured and tested in order to investigate the effects of both adhesive thickness (0.4, 2.0, and 4.0 mm) and environmental conditions on the failure of the joints. The results showed that failure occurred mainly as intralaminar failure in the first layer of the sandwich face, which was contacted to the paste adhesive. The failure load did not significantly change with increasing adhesive thickness in both RTD (Room Temperature and Dry) and ETW (Elevated Temperature and Wet) conditions. In the case of ETW conditions, however, the failure load increased slightly with an increase in adhesive thickness. The joints tested in ETW conditions had higher failure loads than those tested in RTD conditions. In addition to the experiment, a finite element analysis was also conducted to investigate the failure of the joint. The stress inside the first ply of the sandwich face was of interest because during the experiment, failure always occurred there. The analysis results showed good agreement with the trend of experimental results, except for the case of the smallest adhesive thickness. The highest stress was predicted in the regions where initial failure was observed in the experiment. The maximum stress was almost constant when the adhesive thickness was beyond 2 mm.

Preparation of Pressure Sensitive Adhesive Using Reactive Polyurethane Resin and the Effect of Interfacial Crosslinking on the Adhesion Property (반응성 폴리우레탄 레진을 이용한 Pressure Sensitive Adhesive 제조 및 계면 가교 반응이 점착 물성에 미치는 영향)

  • Shin, Jin Sup;Kim, Ji Heon;Cheong, In Woo;Kim, Jung Hyun
    • Applied Chemistry for Engineering
    • /
    • v.16 no.1
    • /
    • pp.81-85
    • /
    • 2005
  • Pressure sensitive adhesive (PSA) was prepared by semi-batch emulsion polymerization of acryl monomers in the presence of reactive and non-reactive carboxylated polyurethane resin (PUR). Effects of the PUR type, its content, and crosslinker feeding method on the adhesive properties of the PSA was investigated. In this experiment, the PSA prepared with the reactive PUR showed better adhesive property then the PSA with the non-reactive PUR. Especially, peel strength of the PSA, where acetoacetoxy ethyl methacrylate and 1,6-hexane diamine as crosslinkers were introduced, was dramatically enhanced in severe humidity condition due to the interfacial crosslinking.

Adhesive Silicone Gel Sheet for Treatment of Nailbed Injury (손톱바닥 치료를 위한 부착형 실리콘 겔 시트의 유용성)

  • Kim, Eui Sik;Hwang, Jae Ha;Kim, Kwang Seog
    • Archives of Plastic Surgery
    • /
    • v.33 no.1
    • /
    • pp.107-112
    • /
    • 2006
  • If autogenous nail is lost in nail bed injuries, alternative effective nail bed protection material is questionable in postoperative follow up period. The conventional modality with autogenous nail coverage have several disadvantages such as drawback of maintenance, higher chance of loss and complex dressing step (eg. ointment apply for humidification and nail fixation using tape or bandage). So, we have studied the usefulness of adhesive silicone gel sheet for alternative nail bed protection material until the end of nail regeneration. From March 2003 to July 2004, we have experienced 215 traumatic nail bed injuries except fingertip loss. Among these patient, we classified two groups, 30 cases with autogenous nail protection(Group I) and 30 cases with adhesive silicone gel sheet protection(Group II). Mean full nail growth time was 3.6 months in group I and 3.8 months in group II. Mean final nail appearance score(0: poor, 4: excellent) was 3.0 in group I and 3.5 in group II. Adhesive silicone gel sheet protection(Group II) was slightly superior to the autogenous nail protection in final appearance, especially sterile matrix laceration. In conclusion, we believe that adhesive silicone gel sheet application is a simple, acceptable, alternative method for protecting nail bed with loss of autogenous nail. It has a number of advantages compared with autogenous nail such as better humidification, controllable hygiene, less pain, less hospitalization, less frequent visit, less chance of loss, avoiding complex dressing step and more even pressure with adhesiveness, flexibility and durability.