• Title/Summary/Keyword: Adhesive method

Search Result 827, Processing Time 0.033 seconds

Effects of Mixing Ratio of Urea and Mlelamine on Formaldehyde Emission and Bonding Properties of Plywoods Manufactured with Urea-Melamine Formaldehyde Adhesives (요소-멜라민 공축합 수지의 요소와 멜라민 혼합비율이 합판의 포름알데히드 방출과 접착성에 미치는 영향)

  • Park, Heon;Kang, Eun-Chang;Min, Kyeong-Heui
    • Journal of the Korea Furniture Society
    • /
    • v.11 no.1
    • /
    • pp.53-59
    • /
    • 2000
  • This study was to measure formaldehyde emission and bonding strength of plywoods manufactured with urea-melamine formaldehyde adhesives, which were made from three different mixing ratios of urea and melamine, and with four different formaldehyde/urea-melamine molar ratios of 1.0,1.1,1.2 and 1.4. The results were as follows 1. Amount of formaldehyde emission was the lowest at the first method of molar ratio(F/(M+U)) 1.0. Amounts of formaldehyde emission of experimental manufactured adhesives were lower than that of commercial adhesive. 2. Bonding strength of dry specimen was the highest at the first method of molar ratio(F/(M+U)) 1.4. Dry bonding strength of molar ratio(F/(M+U)) 1.4 was similar to commercial adhesive. 3. Bonding strength of wet specimen was the highest at the second method of molar ratio(F/(M+U)) 1.4. Bonding strength of wet specimen used by the third method of molar ratio(F/(M+U)) 1.4 was almost equal to commercial adhesive.

  • PDF

A Study on Properties of UV-Curing Silver Paste by Dispersing Agent Characteristic (분산제 특성에 따른 UV 경화형 Ag Paste의 물성 연구)

  • Son, Min-Jeong;Nam, Su-Yong;Kim, Sung-Bin
    • Journal of the Korean Graphic Arts Communication Society
    • /
    • v.30 no.2
    • /
    • pp.59-68
    • /
    • 2012
  • As one of the eletronic device industries has been developed by using a recent printing method, the consumption of Ag paste has been on the rise as well. The printing method has simple processes in comparison with other methods. Also it enables to be large-scaled and to lower price ranges. If UV curing system would be applied to the printing method, energy consumption and dangerousness from curing system can be minimized in a short period of time so that its method can be more eco-friendly. This study conducted an experiment in order to make UV curing Ag paste which is feasible to implement micro patterns with different dispersing agents. The purpose of the study is to analysis the suitable printability for micro pattern and to test dispersibility, hardening properties, conductivity and adhesive stength by measuring viscosity, TI(thixotropy index), G', G", $tan{\delta}$(G"/G') after making paste. We have experimented with four dispersing agents. After We did an analysis of characteristic of rheology, conductivity and adhesive stength, etc, We confirmed that the paste added FP 3060 has excellent dispersibility, conductivity and adhesive stength. If the paste has excellent dispersibility, we will expect that micro pattern is made by that.

A Debonding Detection Technique for FRP/Rubber Interface by Ultrasonic Phase Reversal (초음파 위상 반전에 의한 FRP/고무 접착 계면의 미접착 결함 검출 연구)

  • Kim, Dong-Ryun;Lim, Soo-Yong;Chung, Sang-Ki
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.13 no.2
    • /
    • pp.9-16
    • /
    • 2009
  • The object of this study is to develop new examination technique for detecting debond in adhesive interface of different kinds of materials. Ultrasonic signal was modeled by theoretically analyzing ultrasonic propagation phenomenon of the adhesive interface and debonding interface. The test method using the phase reversal of the debonding interface applied to the FRP/Rubber test block. Aluminum/Rubber test block with the flat bottom hole was manufactured to evaluate quantitatively the minimum detection ability of defects. The pulse echo reflection method and the phase reversal method were mutually compared and it was estimated that the phase reversal method could detect the debond on the basis of the theoretically predicted ultrasonic signal and ultrasonic test data.

Material Parameters Identification of Adhesive in Layered Plates Using Moiré Interferomety and Optimization Technique (무아레 간섭계 측정과 최적화 기법을 이용한 적층판의 접착제 물성치 규명)

  • Joo, Jin-Won;Kim, Han-Jun;Lee, Woo-Hyuk;Kim, Jin-Young;Choi, Joo-Ho
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.31 no.11
    • /
    • pp.1100-1107
    • /
    • 2007
  • In this study, a method to characterize material properties of adhesive that is used in a layered plates bonding process is developed by combined evaluation of experiment, simulation and optimization technique. A small bonded specimens of rectangular plate are prepared to this end, and put into a thermal loading conditions. $Moir{\acute{e}}$ interferomety is used to measure submicron displacements occurred during the process. The elevated temperature is chosen as control factors. FE analysis with constant values for the adhesive materials is also carried out to simulate the experiment. Significant differences are observed from the two results, in which the simulation predicts the monotonic increase of the bending displacement whereas the measurement shows decrease of the displacement at above $75^{\circ}C$. In order to minimize the difference of the two, material parameters of the adhesive at a number of different temperatures are posed as unknowns to be determined, and optimization is conducted. As a result, optimum material parameters are found that excellently matches the simulation and experiment, which are decreased with respect to the temperature.

A Study for Selection and Field Applicability of Asphalt Precast Pothole Repair Materials (아스팔트 프리캐스트 포트홀 보수재료의 선정과 현장 적용성에 관한 연구)

  • Kim, Jincheol;Bae, Sungho;Lee, Jinho;Yang, Jaebong;Kim, Jiwon
    • International Journal of Highway Engineering
    • /
    • v.16 no.4
    • /
    • pp.21-33
    • /
    • 2014
  • PURPOSES: The purpose of this study was to break away from the workforce method using cold-mix asphalt mixtures and has a constant quality and has develop repair materials of pre-production asphalt-precast types. METHODS: The selection of the repair material was determined as the results obtained through physical properties of materials and the field applicability. In case of repair materials, values obtained through Marshall stability test & the dynamic stability test & retained stability test as well as the site conditions was considered. In case of adhesive, test results were obtained through examination of the bond strength(tensile, shear) and the field applicability of the adhesive was examined through combined specimens to simulate field applications. RESULTS : According to the results of laboratory tests, in the case of repair materials, Marshall stability and dynamic stability, retained stability of cold-mix reaction type asphalt mixture is the highest. In the case of adhesive, two-component epoxy-urea has a very high bonding strength(tensile, shear) was most excellent. According to the results of field tests, when epoxy-urea was excellent workability. Also, the repair body through actual mock-up test did not occur large deformation and fracture after 12 months. CONCLUSIONS : A suitable repair material is cold-mix reaction type mixture of asphalt-precast, a suitable adhesive is a two-component epoxy-urea.

A Study on the Adhesive Condition of the Nonwoven Fabrics in Sewing of the Leather (피혁봉재에 있어서 부직포 접착심지의 접착방법에 관한 연구)

  • Kim Young Ja
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.5 no.2
    • /
    • pp.35-40
    • /
    • 1981
  • This study aims at finding appropriate adhesive conditions with special regard the material of 'fusible padding cloth inter ling' was frequently used for leather. As for leather material, pig suede, sheep suede were selected and drum dyed, cow split, napa have also been used. Mixed spinning non-woven fabric (polyester $50\%$, nylon $50\%$) were used as for padding cloth. Experimental appearance has been observed under the following adhesive conditions: Temperature of press were devided four levers; $120^{\circ}C$, $130^{\circ}C$, $140^{\circ}C$, $150^{\circ}C$, respectively. Adhesive time has been limited 5, 10, 15 second each. And the pressure has been conditioned as $0.2kg/cm^2$ continuously. After all this experiment, it was discovered that the material which had long contact with low temperature conditions has similar adhesive power to material that has short contact with high temperature conditions. There is a great difference according to the leather's dying process, the finishing method of the cloth, and the part of leather surface. The best condition for suede are $140^{\circ}C$, $150^{\circ}C$, at 10 seconds. and for D/D, NAPA, $130^{\circ}C$, at 10 seconds. Although the conditions of $150^{\circ}C$, at 15 seconds was possible for split, the process time can be shortened according to the increase of temperature.

  • PDF

Comprehensive Wear Study on Powder Metallurgical Steels for the Plastics Industry, Especially Injection Moulding Machines

  • Gornik, Christian;Perko, Jochen
    • Proceedings of the Korean Powder Metallurgy Institute Conference
    • /
    • 2006.09a
    • /
    • pp.399-400
    • /
    • 2006
  • M390 microclean(R) of $B{\ddot{o}}hler$ Edelstahl is a powder metallurgical plastic mould steel with a high level of corrosion and wear resistance and therefore often used in the plastics processing industry. But as a consequence of rapidly advancing developments in the plastics processing industry the required level of wear resistance of tool steels in this field is constantly rising. For that reason a new PM tool steel with higher hardness values and an increased amount of primary carbides has been developed to improve the resistance against abrasive and adhesive wear. The wear resistance of both steels against adhesive situations for components of the plastification unit of injection moulding machines has been tested with a novel method. In case of processing polyolefins with an injection moulding machine it was found that there is adhesive wear between the check-ring and the flights of the screw tip of the non-return valve under certain circumstances. The temperature in that region was measured with an infrared temperature sensor. The existence of significant peaks of that signal was used as an indicator for an adhesive wear situation.

  • PDF

Evaluation of Failure Mode and Strength on Baking Time of Adhesive for Hybrid Joining (접착제 경화시점에 따른 하이브리드 접합 파단모드 및 접합강도 평가)

  • Choi, Chul-Young;Saha, Dulal Chandra;Choi, Won-Ho;Kim, Jun-Ki;Kim, Jong-Hoon;Park, Yeong-Do
    • Journal of Welding and Joining
    • /
    • v.29 no.6
    • /
    • pp.49-55
    • /
    • 2011
  • With the development of pre-painted steel sheets for automotive body application, a new joining method is required such as hybrid joining with combination of adhesive bonding and mechanical joining. The objective of this study is to investigate the effect of pre- and post-baking of adhesive bonding on failure mode and strength of hybrid joining of automotive steel sheets. Experiments show that the hybrid joining exhibits better bonding strength and displacement than conventional adhesive joining and mechanical fastening each. Comparison of pre- and post-baked hybrid joining results suggested that baking at $160^{\circ}C$ after mechanical joining was found to have higher joining properties than pre-baking condition. The prebaking condition changed its fracture mode from interfacial to button fracture. The changes in fracture mode with post-baking of hybrid joining was attributed to variation in neck thickness and undercut of joint.

A Histo-Pathological Study of Effect on Bone Regeneration with Fibrin Adhesive (이종골 이식시 Fibrin adhesive의 사용이 골 재생에 미치는 영향에 관한 조직병리학적 연구)

  • Ko, Young-Woo;Lim, Sung-Bin;Chung, Chin-Hyung;Lee, Chong-Heon
    • Journal of Periodontal and Implant Science
    • /
    • v.33 no.1
    • /
    • pp.91-102
    • /
    • 2003
  • Several effective treatment methods and materials have been developed for the treatment of furcation involvement. Currently, the combination of guided tissue regeneration (GTR) and bone grafts is the most commonly prescribed method of treating furcation involved defects. But because these cases often present with poor accessibility, placement of the membrane may be difficult and consequently, clinically impractical. In this study, the alveolar bone healing patterns of adult beagle dogs presenting with alveolar bone destruction treated by one of two methods - treatment using solely bone allografts (BBP(R)), or treatment using bone allografts (BBP(R)) stabilized by a fibrin adhesive - were comp ared. The effects of the fibrin adhesive on the initial stabilization of the newly formed bone, subsequent regeneration of bone, and the feasibility of the clinical application of the fibrin adhesive were analyzed. The results of the study were as follows: 1. Clinical signs of inflammation at the 4-8 week interval were not observed: but signs of mild inflammation were histologically observed at the 4-week interval. 2. Allografts stabilized by fibrin adhesive showed good bone formation, whereas defects treated with only the allograft material showed incomplete alveolar bone regeneration. 3. Allografts stabilized by fibrin adhesive showed a decrease in the amount old bone with a concurrent increase in the formation of new lamellar bone four weeks post-op, whereas defects treated with only the allograft material showed no new lamellar bone formation at the same interval. 4. In detects treated with only the allograft material, the defective area was filled with connective tissue 8-weeks post-op, whereas fibrin adhesive stabilized allografts showed viable connections between the original bone and the newly formed bone, in addition to neovascularization 8-weeks post-op. The results of this study show that concurrent use of fibrin adhesive materials can stabilize the allograft material and aid in new bone formation Although the stability of fibrin adhesives fall short of the results achievable by GTR membranes, in cases presenting with poor accessibility that contraindicate the use of membranes, fibrin adhesive materials provide a viable and effective alternative to graft stabilization and new bone formation.

A STUDY ON THE ADHESIVE BOND STRENGTH OF COMPOSITE RESIN TO Au-Ag-Cu-Pd ALLOY (Au-Ag-Cu-Pd합금과 복합레진간의 접착결합강도에 관한 연구)

  • Seol Young-Hoon;Jung Chang-Mo;Jeon Young-Chan
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.32 no.3
    • /
    • pp.378-395
    • /
    • 1994
  • The purpose of this study was to investigate the effect of various metal surface treatments and adhesive systems on the flexural bond strength of composite resin to Au-Ag-Cu-Pd alloy. The specimens were divided into nine groups by the combinations of surface treatment methods and adhesive systems. The types of surface treatment in this study were alumina blasting only, alumina blasting-Sn plating, alumina blasting-heating and three kinds of adhesive system used in this study were Silicoater system(Heraeus Kulzer GmbH,Germany), Superbond C & B(Sun Medical Co.,Ltd.,Japan) and Cesead opaque primer(Kurary Co.,Ltd.,Japan). After surface treatments and adhesive systems were applied, each specimen was built up with Dentacolor composite resin (Heraeus Kulzer GmbH,Germany). Four-point flexural bond strength was measured by Instron universal testing machine (Model 4301,U.S.A.) and modes of failure were observed by SEM(JEOL,SSM-840A,Japan). The obtained results were as follows: 1. The group that was bonded with Superbond C & B after alumina blasting-heating shelved the highest bond strength with significant difference among the groups, except the group with Cesead opaque primer after alumina blasting-Sn plating(P<0.05). 2. In the groups bonded with Cesead opaque primer, there was significant difference only in the bond strength between the alumina blasting-Sn plating group and alumina blasting group, where the former showed a higher bond strength(P<0.05). 3. In the groups bonded with Silicoater system, there were no significant differences in bond strength regardless of the surface treatment method(P<0.05). 4. In SEM evaluation, the groups of high bond strength, especially bonded with Superbond C & B after alumina blasting-heating and Cesead opaque primer after alumina blasting-Sn plating, revealed mainly cohesive-adhesive failure, whereas the others showed the tendency of adhesive failure.

  • PDF