• 제목/요약/키워드: Adhesive disk

검색결과 37건 처리시간 0.023초

미끄럼조건에 따라 TiN 코팅볼과 스틸디스크에 형성되는 산화막이 마찰특성에 미치는 영향 (The Effect of Oxide Layer Formed on TiN Coated Ball and Steel Disk on Friction Characteristics in Various Sliding Conditions)

  • 조정우;이영제
    • Tribology and Lubricants
    • /
    • 제17권6호
    • /
    • pp.459-466
    • /
    • 2001
  • In this study, the effects of oxide layer formed on the contact parts of TiN coated ball and steel disk on friction characteristics in various sliding conditions were investigated. AISI52100 steel ball was used for the substrate of coated ball specimens, which were prepared by depositing TiN coating with 1(m in coating thickness. AISI1045 steel was used for the disk type counter-body. To investigate the effect of oxide layer on the contact parts of two materials, the tests were performed both in air for forming oxide layer on the contact parts and in nitrogen environment to avoid oxidation. From the test results, the frictional characteristic between the two materials was predominated by iron oxide layer that formed on wear tract of counter-body and this layer caused friction transition and high friction. And the adhesive wear occurred from steel disk to TiN coated ball caused the formation of oxide layer on counter parts between the two materials.

관절원판 절제술후 중간삽입물 고정에 피브린 접착제의 응용 (APPLICATION OF FIBRIN ADHESIVE IN DISK REPLACEMENT AFTER MENISCECTOMY)

  • 정훈;김형근;김영수;유기준;안병근
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • 제14권3호
    • /
    • pp.175-184
    • /
    • 1992
  • Meniscectomy is indicated for the internal derangement of disk with perforation and gross morphological changes, nonreactive to conservative treatment procedures. After the meniscectomy, permanent disk replacement can be followed. Variable materials have been introduced for disk replacement. Of them, relatively harder replacing materials should have been fixed with surgical wire only. This poor fixation method provide inadequate retentive force and conclusively can be attributed to postoperative noise, poor prognosis. We tried to use biocompatible fibrin adhesive in order to obtain additional fixation force in the method above mentioned and treated two patients with the late stage of internal derangement of disk In both cases, satisfactory results were obtained.

  • PDF

Ni계 및 Co계 합금 PTA 오버레이용접층의 마모거동에 관한 연구 (Wear Behavior of Plasma Transferred Arc Deposited Layers for Ni - and Co - base Alloy)

  • 윤병현;이창희;김형준
    • Journal of Welding and Joining
    • /
    • 제19권5호
    • /
    • pp.540-547
    • /
    • 2001
  • This study has evaluated the wear behavior of PTA (Plasma Transferred Arc) Inconel 625 and Stellite 6 overlays on Nimonic 80A substrate. Nimonic 80A alloy was also included for comparison. In order to evaluate the wear performance, three-body abrasive wear test and pin-on-disk dry sliding wear test were performed. Microstructural development during the solidification of deposits is also discussed. Wear test results show that the wear rate of Stellite 6 deposit is lower than that of Inconel 625 deposit and Nimonic 80A. The sliding wear resistance of overlay deposits follows a similar trend to the abrasive wear resistance, but for Nimonic 80A. The main wear mechanisms were abrasive wear for Inconel 625 deposit, adhesive wear and delamination for Stellite 6 deposit in pin-on-disk dry sliding wear test and ploughing in three-body abrasive wear test. Cross sectional examinations of the worn surface of pin specimens after pin-on-disk dry sliding wear test implies that the plastic deformation near worn surface has occurred during the wear testing.

  • PDF

착생에 따른 담쟁이덩굴 흡착근 표피조직의 변화 (Epidermal Changes of the Adhesive Disks During Wall Attachment in Parthenocissus tricuspidata)

  • 김정하;김인선
    • Applied Microscopy
    • /
    • 제37권2호
    • /
    • pp.83-91
    • /
    • 2007
  • 식물체는 기관에 따라 조직 및 세포의 종류와 배열이 분화 초기단계에 이미 정해져 특징적인 형태를 갖게 되나 여러 요인에 의해 변형되기도 한다. 줄기에 덩굴손이 변형되어 부정근인 흡착근을 형성하는 담쟁이덩굴은 벽면 등의 피착면에 착생하는 식물로 이들의 흡착근은 특징적인 구조를 지닌다. 본 연구에서는 착생에 따른 담쟁이덩굴의 흡착근 표피조직의 분화양상을 전자현미경적으로 추적하여 연구하였다. 흡착근은 분화 초기에 경정단 분열조직으로부터 포에 둘러싸여 발달한다. 초기의 어린 흡착근은 곤봉형으로 상 하피 구별이 되지 않으나 활발히 생장하는 흡착근은 구형으로 상 하피가 뚜렷이 분화된다. 최외층의 표피는 장방형의 세포로 구성되며 이들 표피세포는 세포벽에 얇은 각피층을 지닌다. 착생 전 흡착근은 볼록한 평철형이 되고 표피세포내 액포에는 전자밀도가 매우 높은 물질이 다량 축적된다. 착생 직전 및 직후 흡착근의 상 하피조직은 빠르게 변형되어 액포에 축적된 물질이 분비되면서 피착면에 더욱 밀착되고 수분이 소실된 흡착근은 세포사멸의 과정을 거친다. 이 시기 하피조직에서의 변화는 상피조직에 비해 급격히 일어나며, 분비물질은 벽면에 강력히 흡착되어 착생의 기능을 수행하게 된다. 특히 착생을 전후로 급격한 하피조직의 변화가 일어나 흡착근 하피조직의 외곽면이 먼저 피착면에 접촉하고 전자밀도가 높은 물질이 분비되어 오목한 상태를 유지하던 중앙부위도 물질이 분비되면서 흡착근 전체가 부착되게 된다. 즉, 전자밀도가 높은 물질의 분비와 수분소실에 의한 흡착근의 피착면으로의 밀착 등이 담쟁이덩굴 흡착근의 착생에 매우 중요한 역할을 하는 것으로 추정된다. 매년 이와 같은 방법으로 흡착근은 분화 초기단계에서부터 노화에 이르기까지 여러 단계를 거치며 신속한 형태적, 구조적 변화를 수반하면서 강력한 착생기능을 수행하게 된다.토끼 면역항체를 선모충유충 조직항원에 반응시켰을 때 충체의 표피와 기저층 그리고 EIM 및 stichocyte의 ${\alpha}_0\;{\alpha}_1$ 과립에 황금입자가 표지되었다. 따라서 1일 동안 배설되는 분비배설항원은 선모충 유충의 표피와 stichocyte의 ${\alpha}_0\;{\alpha}_1$ 과립에서 유도되는 반면에 3일 동안 배설되는 분비배설항원은 표피와 stichocyte의 ${\alpha}_0$ 과립에서 유도되고, 선모충유충 감염후 1주, 4주에 실험쥐에서 형성되는 감염항체는 선모충의 표피와 기저층 그리고 EIM에서 분비되는 항원에 의하여 생성된다. 이상의 결과로 선모충의 분비배설항원과 감염항원은 선모충 유충의 표피와 EIM및 stichocyte의 ${\alpha}_0\;{\alpha}_1$ 과립에서 유도되며 이들은 45 kDa 단백을 포함하고 있는 것으로 생각된다.성하고 있는 세포들에는 세포질이 어두운 세포와 밝은 세포가 있었으며, 세포질내에는 전자밀도가 높은 분비과립이 관찰되었다. 전체적인 특징은 눈물샘분비세포 중 장액세포의 것과 비슷하였으나, 과립의 크기는 작았다. 분비관을 구성하는 세포들 사이에도 연접복합체가 매우 잘 발달되어 있었다. 샘포에서 사이관으로 이행되는 곳에서도 샘포세포와 사이관세포 사이에서도 연접복합체가 관찰되었다. 분비관세포의 분비과립 가운데는 중심부분에 전자밀도가 더 높은 중심을 가진 다른 모양의 과립이 관찰되기도 하였다. 의해 사망한 환자는 없었다. 결 론: 자궁경부암 환자에 항암화학요법과 동시에 외부 방사선조사와 고선량률의 강내조사를 시행한 결과 독성이 심하지 않고 국소제어율과 단기 생존율이 양호하여 안전하고 효율적인 치료방법으로 생각된다. 그러나 장기 생존율과

합착방법(合着方法)에 따른 복합(複合)레진 인레이의 변연폐쇄효과(邊緣閉鎖效果) (THE MARGINAL SEALING EFFECT OF COMPOSITE RESIN INLAYS ACCORDING TO THE LUTING TECHNIQUES)

  • 문영덕;조규징
    • Restorative Dentistry and Endodontics
    • /
    • 제16권1호
    • /
    • pp.121-132
    • /
    • 1991
  • The purpose of the study was to evaluate the marginal sealing effect of composite resin inlays according to the luting techniques and compare them to the conventional direct resin filling technique. 90 cavities of class V were prepared on the buccal surface of 90 extracted molar teeth, which were divided into four groups. Cavities of control group were directly filled with Scotchbond 2 and P - 50, and those of composite resin inlay groups were luted with one of the followings: Adhesive bond followed by Adhesive cement, All bond followed by Adhesive cement, Fuji - ionomer type L All the specimens were immersed in India ink dye solution for 7 days at $37^{\circ}C$ incubator after thermocycling between $5^{\circ}C$ and $60^{\circ}C$ and longitudinally sectioned with diamond disk inot two parts All the specimens were observed at the occlusal and gingival margins and statistical analysis was performed. The results were as follows: 1. Groups filled with composite resin inlay showed less marginal leakage than the group directly filled(p<0.01). 2. There was no significant difference in marginal leakage between composite resin inlay groups luted with Adhesive bond followed by Adhesive cement and the group luted with All bond followed by Adhesive cement(p>0.05). 3. At occlusal margins, Composite resin inlay group luted with Adhesive bond followed by Adhesive cement showed less marginal leakage than the group luted with Fuii ionomer type I(p<0.01). At gingival margins, composite resin inlay group luted with All bond followed by Adhesive cement showed less marignal leakage than the group luted with Fuji ionomer type I(P<0.01).

  • PDF

Friction transition diagram considering the effects of oxide layer formed on contact parts of TiN coated steel ball

  • Cho, C.W.;Lim, J.S.;Lee, Y.Z.
    • 한국윤활학회:학술대회논문집
    • /
    • 한국윤활학회 2002년도 proceedings of the second asia international conference on tribology
    • /
    • pp.179-180
    • /
    • 2002
  • In this study. the friction transition diagram based on the effect of oxide layer formation on contact surface between TiN coated steel ball and uncoated steel disk was constructed. From the diagram. it can be seen that as the contact load increases. the contact number of cycle at the beginning of oxide layer formation decreases linearly and as the coating thickness increases and the surface roughness of steel disk increases under same contact load. that increases. For the coated ball specimen, a AISI 52100 steel ball was used and AISI 1045 steel was used for the disk counter part.

  • PDF

유한요소 해석을 이용한 현장 콘크리트 부착강도 측정조건 (Measurement Conditions of Concrete Pull-off Test in Field from Finite Element Analysis)

  • 김성환;정원경;권혁;김현오;이봉학
    • 산업기술연구
    • /
    • 제22권A호
    • /
    • pp.185-192
    • /
    • 2002
  • The performance of old and the new concrete construction depends upon bond strength between old and the new concrete. Current adhesive and strength measurement method ignores the effect of stress concentration from shape of specimens. Therefore, this research calculates stress concentration coefficient as the ratio of drilling depth to drilling diameter($h_s/D$), the ratio of overlay thickness to drilling diameter($h_0/D$), the ratio of steel disk thickness to drilling diameter(t/D), the ratio of overlay elastic modulus to substrate modulus($E_1/E_0$), the distance from core to corner border(L_$_{corner}$) and the distance between cores(L_$_{coic}$) vary. The finite element method is adapted to analysis The results from 'the F.E.M analysis are as follows. The stress concentration effects can be minimized when the ratio of drilling depth to drilling diameter($h_s/D$) is 0.20~0.25, the elastic modulus ratio($E_1/E_0$) is 06~1.0, and the ratio of steel disk thickness to drilling diameter(t/D) is 3.0. The overlay thickness, the distance from specimens to corner border(L_$_{corner}$), the distance between cores(L_$_{coic}$) almost do not affect to the stress concentration.

  • PDF

치경부 마모증 수복시 상아질 접착제가 변연누출에 미치는 영향 (THE EFFECT OF DENTIN BONDING AGENTS ON MARGINAL LEAKAGE FOLLOWING RESTORATION ON THE CERVICAL ABRASION)

  • 구본욱;손호현
    • Restorative Dentistry and Endodontics
    • /
    • 제12권2호
    • /
    • pp.55-63
    • /
    • 1987
  • The purpose of this study is to evaluate the effect of dentin bonding agents on marginal leakage. V-shaped cavities were prepared on the faciocervical area of 140 extracted human teeth. In Groups of twenty cavities, they were restored as follow: Group 1 with enamel bonding resin and Silux, Group 2 Scotchbond and Silux, Group 3 enamel bonding resin and Heliomolar, Group 4 Dentin Adhesit and Heliomolar, Group 5 enamel bonding resin and Durafill, Group 6 Dentin Adhesive and Durafill, Group 7 Chembond. All specimens were thermocycled alternatively at $4^{\circ}C$ and $60^{\circ}C$ of 2% methylene blue dye solution, and sectioned faciolingually with diamond disk under water spray. The sectioned specimens observed with stereo microscope. Following results were obtained: 1. The groups filled with Scotchbond-Silux or Dentin Adhesit-Heliomolar had appeared lesser marginal leakage compared with the groups with enamel bonding resin-Silux or enamel bonding resin-Helimolar. 2. The group filled with Dentin Adhesive-Durafill did not show the reduction of the marginal leakage compared with the group with enamel bonding resin-Durafill. 3. There was significant difference among the four dentin bonding agents. Scotchbond showed the greatest marginal sealing ability, and Dentin Adhesit was the next. The marginal sealing ability of Dentin Adhesive was the worst.

  • PDF

Power 서보 실린더의 피스톤 헤드용 AlBC의 마멸 특성 (Wear Characteristics of AlBC for Piston Head of Power Servo Cylinder)

  • 조연상;박흥식
    • Tribology and Lubricants
    • /
    • 제27권2호
    • /
    • pp.65-70
    • /
    • 2011
  • The power servo cylinder for driving accurately turbine stop valve of an atomic power plant is necessary to do turn-over owing to a leakage of oil and a structure problem, especially, it of a power plant be in demand a high quality standard depends entirely on import. There are much problem that the AlBC be to used as a material of piston head in cylinder are caused by wear. Therefore, it is necessary to examine friction characteristics of it. In this study, wear test experiments was carried out with AlBC and SCM440, using reciprocating friction tester of pin on disk. This result was shown that the wear mechanism of AlBC on working condition is adhesive wear and the maximum temperature of infra redray thermal image of frictional surface show over 2 mm from contact surface of pin and disk.