• Title/Summary/Keyword: Adhesive disc

Search Result 40, Processing Time 0.028 seconds

A CONFOCAL MICROSCOPIC STUDY ON DENTINAL INFILTRATION OF ONE-BOTTLE ADHESIVE SYSTEMS AND SELF-ETCHING PRIMING SYSTEM BONDED TO CLASS V CAVITIES (제 5급 와동에서의 단일용기 상아질 접착제와 자가 산부식 접착제의 상아질에 대한 침투도 평가)

  • Kim, Hyung-Su;Park, Sung-Ho
    • Restorative Dentistry and Endodontics
    • /
    • v.27 no.3
    • /
    • pp.257-269
    • /
    • 2002
  • Objective : The purpose of this study was to evaluate the resin infiltration into dentin of one-bottle adhesive systems and self-etching primer bonded to Class V cavities using confocal laser scanning microscope(CLSM). Material and Methods : Forty Class V cavities were prepared from freshly extracted caries-free Human teeth. These teeth were divided into two groups based on the presence of cervical abrasion: Group I, cervical abrasion : Group II, wedge-shaped cavity preparation. Resin-dentin interfaces were produced with two one-bottle dentin bonding systems-ONE COAT BOND(OCB; Coltene$^R$) and Syntac$^R$SPrint$^{TM}$(SS; VIVADENT)-, one self-etching priming system-CLEARFIL$^{TM}$ SE BOND (SB : KURARAY)- and one multi-step dentin bonding system-Scotchbond$^{TM}$Multi-Purpose (SBMP, 3M Dental Products)-as control according to manufacturers' instructions. Cavities were restored with Spectrum$^{R}$(Dentsply). Specimens were immersed in saline for 24 hours and sectioned longitudinally with a low-speed diamond disc. The resin-dentin interfaces were microscopically observed using CLSM. The quality of resin-infiltrated dentin layers were evaluated by five dentists using 0~4 scale. Results : Confocal laser scanning microscopal investigations using primer labeled with rhodamine B showed that the penetration of the primer occurred along the cavity margins. Statistical analysis using one-way ANOVA followed by Duncan's Multiple Range test revealed that the primer penetration of the group 2(wedge-shaped cavity preparation) was more effective than group 1(cervical abrasion) and that of the gingival interfaces was more effective than the occlusal interfaces. In the one-bottle dentin bonding systems, the resin penetration score of OCB was compatible to SBMP, but those of SS and self-etching priming system, SB were lower than SBMP.

Orthodontic bracket bonding to glazed full-contour zirconia

  • Kwak, Ji-Young;Jung, Hyo-Kyung;Choi, Il-Kyung;Kwon, Tae-Yub
    • Restorative Dentistry and Endodontics
    • /
    • v.41 no.2
    • /
    • pp.106-113
    • /
    • 2016
  • Objectives: This study evaluated the effects of different surface conditioning methods on the bond strength of orthodontic brackets to glazed full-zirconia surfaces. Materials and Methods: Glazed zirconia (except for the control, Zirkonzahn Prettau) disc surfaces were pre-treated: PO (control), polishing; BR, bur roughening; PP, cleaning with a prophy cup and pumice; HF, hydrofluoric acid etching; AA, air abrasion with aluminum oxide; CJ, CoJet-Sand. The surfaces were examined using profilometry, scanning electron microscopy, and electron dispersive spectroscopy. A zirconia primer (Z-Prime Plus, Z) or a silane primer (Monobond-S, S) was then applied to the surfaces, yielding 7 groups (PO-Z, BR-Z, PP-S, HF-S, AA-S, AA-Z, and CJ-S). Metal bracket-bonded specimens were stored in water for 24 hr at $37^{\circ}C$, and thermocycled for 1,000 cycles. Their bond strengths were measured using the wire loop method (n = 10). Results: Except for BR, the surface pre-treatments failed to expose the zirconia substructure. A significant difference in bond strengths was found between AA-Z ($4.60{\pm}1.08MPa$) and all other groups ($13.38{\pm}2.57-15.78{\pm}2.39MPa$, p < 0.05). For AA-Z, most of the adhesive remained on the bracket. Conclusions: For bracket bonding to glazed zirconia, a simple application of silane to the cleaned surface is recommended. A zirconia primer should be used only when the zirconia substructure is definitely exposed.

Influence of inorganic composition and filler particle morphology on the mechanical properties of self-adhesive resin cements

  • Marina Rodrigues Santi ;Rodrigo Barros Esteves Lins;Beatriz Ometto Sahadi;Giovanna Correa Denucci;Gabriela Soffner ;Luis Roberto Marcondes Martins
    • Restorative Dentistry and Endodontics
    • /
    • v.47 no.3
    • /
    • pp.32.1-32.11
    • /
    • 2022
  • Objectives: This study aimed to evaluate the influence of inorganic composition and filler particle morphology on the mechanical properties of different self-adhesive resin cements (SARCs). Materials and Methods: Three SARCs including RelyX Unicem-2 (RUN), Maxcem Elite (MAX), and Calibra Universal (CAL) were tested. Rectangular bar-shaped specimens were prepared for flexural strength (FS) and flexural modulus (FM) and determined by a 3-point bending test. The Knoop microhardness (KHN) and top/bottom microhardness ratio (%KHN) were conducted on the top and bottom faces of disc-shaped samples. Sorption (Wsp) and solubility (Wsl) were evaluated after 24 hours of water immersion. Filler morphology was analyzed by scanning electron microscopy and X-ray energy dispersive spectroscopy (EDS). FS, FM, %KHN, Wsp, Wsl, and EDS results were submitted to 1-way analysis of variance and Tukey's post-hoc test, and KHN also to paired t-test (α = 0.05). Results: SARC-CAL presented the highest FS value, and SARC-RUN presented the highest FM. SARC-MAX and RUN showed the lowest Wsp and Wsl values. KHN values decreased from top to bottom and the SARCs did not differ statistically. Also, all resin cements presented carbon, aluminum, and silica in their composition. SARC-MAX and RUN showed irregular and splintered particles while CAL presented small and regular size particles. Conclusions: A higher mechanical strength can be achieved by a reduced spread in grit size and the filler morphology can influence the KHN, as well as photoinitiators in the composition. Wsp and Wsl can be correlated with ions diffusion of inorganic particles.

Encystation of Giardia lamblia by High Bile and Alkaline pH and Its Ultrastructural Changes during Encystation

  • Yong, Tai-Soon;Yang, Hye-Won;Im, Kyung-Il;Park, Soon-Jung
    • Journal of Microbiology and Biotechnology
    • /
    • v.10 no.3
    • /
    • pp.429-433
    • /
    • 2000
  • Giardia lamblia, a human pathogen causing outbreaks of diarrhea, recently became a focus of great concerns in the fields of both medical and environmental microbioloty. To develop the experimental tools to study giardiasis, encystation, one of the major processes in its life cycle, was reconstituted by inducing an axenic culture of a flagellated form of G. lamblia into a cyst from under high concentration of bile and alkaline pH condition. The successful induction was confirmed by Northern analysis of resulting increased expression of the CWPl gene encoding the cyst wall protein 1. An examination of the encystation process with SEM (scanning electron microscopy) and TEM (transmission electron microscopy) revealed that the trophozoite, a flagellate with a bilateral symmetry, was transformed to a cyst form with an oval-shape and defined filamentous wall. The encystation was found to cause a disappearance of the flagella and an invagination of the adhesive disc. An extensive formation of rER (rough endoplasmic reticulum) was observed after 24h of induction, indication an active synthesis and export of proteins during this process. The vital staining of the invitro-induced systs showed that most cysts maintained their viability.

  • PDF

The Dry Sliding Wear Properties of $SiC_w$ and $SiC_p$ Reinforced Bronze Matrix Composites (무윤활 미끄럼 마찰하에서 SiC 휘스커 및 입자강화 청동기지 복합재의 마모특성)

  • 이상로;허무영
    • Tribology and Lubricants
    • /
    • v.9 no.2
    • /
    • pp.49-55
    • /
    • 1993
  • The dry sliding wear properties of the sintered Cu-10 wt%Sn bronze alloys reinforced with $SiC_w$ and $SiC_p$ were investigated by a pin-on-disc wear testing machine. The worn surfaces and the cross sections of the wear specimens and the wear debris were observed by SEM to study the effect of the variation of the ceramic phase contents in the composite and the wear condition on the wear behaviors. The wear of bronze matrix was dominated by the adhesive wear. The transition from mild to severe wear was found in the bronze matrix specimens at the applied load higher than 20N where the surface delamination caused the severe wear. The addition of $SiC_w$ and $SiC_p$ reinforcements in the romposites was proved to reduce the wear rate by the matrix strengthening at the applied load higher than 20N. SiC whiskers having a large length to diameter ratio which hold the deformed matrix were effective to hinder the crack propagation near the worn surface. Thus the maximum wear resistance was obtained in the composite reinforced by $SiC_w$ at the higher applied load.

High Temperature Wear of STD 61 Tool Steels Sliding Against Al-9%Si Coated Steels Used for Hot Press Forming (STD 61 공구강과 상대재인 핫 프레스 가공용 Al-9%Si 코팅강의 고온 미끄럼 마모)

  • Choi, Byung-Young;Kim, Hong-Ki
    • Korean Journal of Metals and Materials
    • /
    • v.47 no.10
    • /
    • pp.667-674
    • /
    • 2009
  • High temperature wear of STD 61 tool steels sliding against the Al-9%Si coated steels used for hot press forming has been studied in comparison with that of the tool steels sliding against the uncoated steels. Wear tests have been performed using a pin-on-disc configuration under an applied normal load of 50N for 20 min with heating the coated and uncoated steels up to 800$^{\circ}C$. It was found on the worn surface of the STD 61 tool steels sliding against the Al-9%Si coated steels that the formation of the glazed layers containing Al transferred from the coated tribopair may contribute to a reduction of the coefficient of friction, and detachment in part occur due to delamination wear, resulting in higher specific wear rate. On the other hand the Fe-oxide wear debris entrapped on the softer surface of the uncoated steels can act as a tribosurface, leading to decreased adhesive wear of the STD 61 tool steels, resulting in a lower specific wear rate.

EFFECT OF MICROLEAKAGE OF A SELF-ETCHING PRIMER ADHESIVE ACCORDING TO TYPES OF CUTTING INSTRUMENTS (삭제기구가 자가 산부식 접착제의 미세누출에 미치는 영향)

  • Kim, Yong-Hee;Park, Jae-Gu;Cho, Young-Gon
    • Restorative Dentistry and Endodontics
    • /
    • v.32 no.4
    • /
    • pp.327-334
    • /
    • 2007
  • The purpose of this study was to evaluate the effect of burs on microleakage of Class V resin restorations when a self-etching primer adhesive was used. Forty Class V cavities were prepared with four different cutting burs on extracted third molars, and divided into one of four equal groups (n = 10); Group 1-plain cut carbide bur (no. 245), Group 2-cross cut carbide bur (no. 557), Group 3-fine diamond bur (TF-21F), Group 4-standard diamond bur (EX-41). The occlusal and gingival margin of cavities was located in enamel and dentin, respectively. Cavities were treated with Clearfil SE Bond and restored with Clearfil AP-X. Specimens were thermocycled, immersed in a 2% methylene blue solution for 24 hours, and bisected longitudinally. They were observed leakages at enamel and dentinal margins. Data were analyzed using Mann-Whitney and Wilcoxon signed ranked test. The results of this study were as follows; 1. At enamel margin, microleakage of group 4 was statistically higher than those of group 1, 2 and 3 (p < 0.01). 2. At dentinal margin, microleakage of group 4 was statistically higher than group 3 (p < 0.01), but group 1 and 2 were not statistically different with group 3 and 4. 3. Enamel microleakage was statistically higher than dentinal microleakage in group 1, 2 and 3 (p < 0.05), but statistical difference between the microleakage of enamel and dentinal margin was not in Group 4. In conclusion, the use of coarse diamond bur showed high microleakage at both enamel and dentinal margin when Clearfil SE Bond was used in class V cavity.

ATTACHMENT AND PROLIFERATION OF HUMAN GINGIVAL FIBROBLASTS ON THE IMPLANT ABUTMENT MATERIALS (임플랜트 지대주 재료에 대한 치은 섬유아세포의 반응)

  • Lim Hyun-Pil;Kim Sun-Hun;Park Sang-Won;Yang Hong-So;Vang Mong-Sook;Park Ha-Ok
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.44 no.1
    • /
    • pp.112-123
    • /
    • 2006
  • Purpose: The biocompatibility and bio-adhesive property of a dental implant abutment are important for proper soft tissue healing and maintenance of osseointegration of implant. However, studies of soft tissue healing and mucosal attachment of various materials of implant abutment other than titanium are still needed. In this study, cell attachment, proliferation, cytotoxicity of human gingival fibroblast for ceramic, gold alloy, Ni-Cr alloy and, commercially available pure titanium as a control were evaluated, using MTS and scanning electron microscopy. Materials and Methods: Specimen was designed to disc, 4mm diameter and 1mm thickness, made of ceramic, gold alloy, Ni-Cr alloy and commercially available pure titanium. Primary culture of human gingival fibroblasts were grown in Dulbecco's modified Eagle's medium with 10% fetal bovine serum and 1% antibiotics. Cells were inoculated in the multiwell plates placed the specimen disc. Cell Titer 96 AQucous One Solution Cell Proliferation Assay were done after 1hour 3hours, 24hours, 3days, 5days of incubation. The discs were processed for scanning electron micrography to evaluate cell attachment and morphologic change. Results: The results were obtained as fellows. 1. The ceramic showed high cell attachment and proliferation and low cytotoxicity, which is as much bioadhesive and biocompatible as titanium. 2. The gold alloy represented limited proliferation of human gingival fibroblast and the highest cytotoxicity among tested materials (p<0.05). 3. The Ni-Cr alloy limited the proliferaion of the human gingival fibroblast compared to titanium(p<0.05) but cytotoxicity on the bottom of well was not so considerable, compared to titanium. 4. On the scanning electron micrographs , the ceramic showed good attachment and proliferation of human gingival fibroblast, which was similar to titanium. But gold alloy and Ni-Cr alloy showed the shrinkage of gingival fibroblast both after 24 hours and 3 days. On 5th day, small amount of the human gingival fibroblast proliferation was observed on the Ni-Cr alloy, while the shrinkage of gingival fibroblast was still observed on the gold alloy. Conclusions: These results suggest that the ceramic abutment is as biocompatible as titanium to make proper mucosal seal. The gold alloy has a high cytotoxicity to limit proliferation of gingival fibroblast, which suggest limited use on the anterior tooth where soft tissue healing is recommeded.

Three New Records of Actiniaria (Anthozoa: Zoantharia) from Korea (한국산 해변말미잘목 (산호충강: 말미잘아강)의 3미기록종)

  • Song Jun-Im;Cha Ha-Rim
    • Animal Systematics, Evolution and Diversity
    • /
    • v.20 no.2
    • /
    • pp.201-214
    • /
    • 2004
  • Some actiniarians were collected from the coasts of Jejudo and Baekdo Islands in Korean waters from 1971 to 2004. They are identified into three species within three families, which are newly recorded to Korean actiniarian fauna: Halcampella maxima Hertwig, 1888 within the tribe Athenaria, and also Aulactinia coccinea (Verrill, 1866) and Stichodactyla tapetum (Ehrenberg, 1834) within the tribe Thenaria. They are described in detail with figures and tables together with the distribution and size of cnidae. In preserved specimens, mature oocytes of H. maxima were observed in winter. Also oocytes and sperm sacs of S. tapetum were surveyed at separate individuals in summer. The unique feature of A. coccinea is a body wall with simple adhesive verrucae extended from margin to limbus in longitudinal rows. In the genus Stichodactyla, the smallest species, S. tapetum is distinguished from S. haddoni by short bulbous tentacles, less than 1.0 mm long, densely packed on the oral disc and also conical marginal ones, 1.5-2.0 mm long. As a result of this study, the Korean actiniarian fauna consists of four athenarian and 23 thenarian species in suborder Nynantheae

Surgical Treatment of Heart Disease: II. Acquired Heart Disease I: Valve Replacement (심장질환의 외과적 요법에 관한 연구: II.후천성 심장질환, 1. 판막대치 이식수술)

  • Lee, Yung-Kyoon;Seo, Gyeong-Pil
    • Journal of Chest Surgery
    • /
    • v.10 no.2
    • /
    • pp.315-326
    • /
    • 1977
  • From 1958 to October 1977, 294 cases of acquired heart disease were operated. There were 68 cases of pericardium, 3 trauma, 2 foreign body, one cardiac thrombus, 3 atrial myxoma, 2 left atrial and 1 right atrial, 2 Budd-Chiari syndrome, and 214 valvular heart disease. Out of 214 cases of valve operation 73 valves were replaced in 64 patients. Male to female ratio was 1.46: 1. The youngest age was 14 years in male and 18 in female. The oldest was 54 years in male and 52 in female. Fifty-five cases of single valve were replaced, consisting of 47 mitral and 8 aortic valves. There were 9 double valve replacement cases which consist of 7 mitral and aortic and 2 mitral .and tricuspid valves. Six varieties of prosthetic valves, 3 ball and 3 disc types and 3 kinds of xenograft tissue valves were utilized. Beall, BjSrk-Shiley and Starr-Edwards prosthetic valves and Hancock valves were used mainly. For single valve 34. 5% and for double valve replacement 44% mortality were noted. There were 23 operative deaths out of 64 patients, over all mortality rate of 36.9%. Mortality for mitral valve replacement was 29.5%. But in recent 12 consecutive cases one death occurred, showing 8.3% mortality. In earlier days thrombocyte anti-adhesive drug dipyramidole-persantin-aspirin and/or SP 54 were adminstered. But in recent cases after heparinization, coumadin and Persantin were prescribed routinely.

  • PDF