• 제목/요약/키워드: Adhesion Test

검색결과 1,108건 처리시간 0.027초

불소수지의 무전해 동도금을 위한 단계적 플라즈마 전처리법에 관한 연구 (Study on Two Step Plasma Treatment for Electroless Cu Plating of Fluoropolymer)

  • 신승한;한성호;김영석
    • 한국표면공학회지
    • /
    • 제38권3호
    • /
    • pp.118-125
    • /
    • 2005
  • Low temperature plasma treatment with different gases and rf powers were performed to improve the adhesion strength between polytetrafluoroethylene(PTFE) and electroless deposited copper. According to the research, $H_2$ plasma having hydrogen radical was more effective in surface polarity modification than $O_2$ plasma due to the defluorination reaction. However, surface roughness of PTFE was more increased with $O_2$ than $H_2$ plasma. PTFE treated with $120W-O_2$ plasma and $250w-H_2$ plasma, consecutively showed rougher surface than single step $250w-H_2$ plasma treated one and more hydrophilic than single step $120W-O_2$ plasma treated one. And it showed 5B tape test grade, which is better adhesion property than 1B or 3B obtained by single step plasma treatment. In addition, adhesion strength between PTFE and Cu deposit is also deeply affected by residual water on its interface.

복합표면처리된 CrN박막의 밀착력에 미치는 스퍼터링 효과에 관한 연구 (Study on the Effect of Sputtering Process on the Adhesion Strength of CrN Films Synthesized by a Duplex Surface Treatment Process)

  • 김명근;김은영;김정택;이상율
    • 한국표면공학회지
    • /
    • 제39권1호
    • /
    • pp.1-8
    • /
    • 2006
  • In this study, effect of sputtering after plasma nitriding and before PVD coating on the microstucture, microhardness, surface roughness and the adhesion strength of CrN thin films were investigated. Experimental results showed that this sputtering process not only removed surface compound layer which formed during a plasma nitriding process but also induced an alteration of the surface of plasma nitrided substrate in terms of microhardness distribution and surface roughness, which in turn affected the adhesion strength of PVD coatings. After sputtering, microhardness distribution showed general decrease and the surface roughness became increased slightly. The critical shear stress measured from the scratch test on the CrN coatings showed an approximately twice increase in the binding strength through the sputtering prior to the coating and this could be attributed to a complete removal of compound layer from the plasma nitrided surface and to an increase in the surface roughness after sputtering.

Ion Beam-based Surface Modification of Polyimide Films for Adhesion Improvement with Deposited Metal Layer

  • Cho, Hwang-Woo;Jung, Chan-Hee;Hwang, In-Tae;Choi, Jae-Hak;Nho, Young-Chang
    • 방사선산업학회지
    • /
    • 제4권4호
    • /
    • pp.335-339
    • /
    • 2010
  • In this study, the surface of polyimide (PI) films was modified using ion implantation to enhance its adhesion to a deposited copper (Cu) layer. The surfaces of the PI films were implanted with 150 keV $Xe^+$ ions at fluences varying from $1{\times}10^{14}$ to $1{\time}10^{16}ions\;cm^{-2}$. The Cu layers were then deposited on the implanted PI. The surface properties of the implanted PI film were investigated based on the contact angle measurements, Fourier transform infrared spectroscopy (FT-IR), X-ray photoelectron spectroscopy (XPS), and atomic force microscopy (AFM). Furthermore, the adhesive strength between the deposited Cu layer and PI film was estimated through a scratch test using a nanoindenter. As a result, the surface environment of the PI film was changed by the ion implantation, which could have a significant effect on the adhesion between the deposited Cu layer and the PI.

식품연포장용 라미네이트 수성 감압점착제의 친환경적 적용에 대한 연구 (Design and Properties of Laminating Waterborne PSA for Eco-friendly Flexible Food Packaging)

  • 이진경;심명식;진인주
    • 접착 및 계면
    • /
    • 제17권2호
    • /
    • pp.49-55
    • /
    • 2016
  • 본 연구는 식품연포장 적층 라미네이트에 주로 사용되는 유성접착제를 대체하기 위해 아크릴 수성화방법을 활용하여 친환경적인 수성 점착제를 설계하였다. 방법으로는 음이온/비이온 그리고 인산에스테르 계면활성제들의 조합과 분자량조절제(chain transfer agent, CTA)의 양을 달리하고, 기능성단량체(functional monomer)의 종류를 달리하였다. 합성된 점착제의 가교 정도와 분자량의 영향을 각각 실험군 8종으로 점착제를 설계 합성하고 조사하였다. 그리고 별도로 분자량이 서로 다른 styrene/alpha-methyl styrene/acrylic acid (SAA) semipolymer 분산제(Mw = 13,000과 Mw = 8,600)를 기존의 계면활성제를 대신하여 사용해 감압점착제(Pressure Sensitive Adhesive, PSA)의 물성을 조사하였다. 합성된 10종의 감압점착제가 유연포장용 기본 물성 규격에 적합한지를 DSC, 입자크기, adhesion, 분자량의 물성 분석으로 평가하였다. 실험 결과 계면활성제는 음이온/비이온 조합으로, CTA는 0.2%로 기능성 단량체는 HEA, GMA를 사용한 점착제 2개의 실험군에서 유연포장에 적용 가능한 분자량과 유연성, 낮은 접착력, 작은 입자의 물성을 확인하였다.

Ar/N2 2단계 플라즈마 처리에 따른 저온 Cu-Cu 직접 접합부의 정량적 계면접착에너지 평가 및 분석 (Effects of Ar/N2 Two-step Plasma Treatment on the Quantitative Interfacial Adhesion Energy of Low-Temperature Cu-Cu Bonding Interface)

  • 최성훈;김가희;서한결;김사라은경;박영배
    • 마이크로전자및패키징학회지
    • /
    • 제28권2호
    • /
    • pp.29-37
    • /
    • 2021
  • 3 차원 패키징을 위한 저온 Cu-Cu직접 접합부의 계면접착에너지를 향상시키기 위해 Cu박막 표면에 대한 Ar/N2 2단계 플라즈마 처리 전, 후 Cu표면 및 접합계면에 대한 화학결합을 X-선 광전자 분광법(X-ray photoelectron spectroscopy)을 통해 정량화한 결과, 2단계 플라즈마 처리로 인해 Cu표면에 Cu4N이 형성되어 Cu산화를 효과적으로 억제하는 것을 확인하였다. 2단계 플라즈마 처리하지 않은 Cu-Cu시편은 표면 산화막의 영향으로 접합이 제대로 되지 않았으나 2단계 플라즈마 처리한 시편은 효과적인 표면 산화방지효과로 인해 양호한 Cu-Cu접합을 형성하였다. Cu-Cu직접접합 계면의 정량적 계면접착에너지를 double cantilever beam 시험방법 및 4점 굽힘(4-point bending, 4-PB) 시험방법을 통해 비교한 결과, 각각 1.63±0.24, 2.33±0.67 J/m2으로 4-PB 시험의 계면접착에너지가 더 크게 측정되었다. 이는 계면파괴역학의 위상각(phase angle)에 따른 계면접착에너지 증가 거동으로 설명할 수 있는데 즉, 4-PB의 계면균열선단 전단응력성분 증가로 인한 계면거칠기의 효과에 기인한 것으로 판단된다.

초고강도강판의 마찰특성에 관한 연구 (Study on the Friction Characteristics of Advanced High Strength Steel Sheet)

  • 김남진;김상헌;정경환;박성호;금영탁
    • 한국소성가공학회:학술대회논문집
    • /
    • 한국소성가공학회 2009년도 추계학술대회 논문집
    • /
    • pp.250-253
    • /
    • 2009
  • In this study, the friction test was performed to find friction characteristics of advanced high strength steel (AHSS) sheets and the multiple regression method was employed to obtain friction models. The friction coefficients associated with the lubricant viscosity, drawing speed, and blank holding pressure are measured. Differently from GA steel sheets, the effects of the lubricant viscosity and pulling speed are a little, which are explained by a theory of adhesion and wear as well as a deformation of friction surface. In addition, the effects of friction parameters are numerically represented by friction regression models.

  • PDF

모재의 재질 및 질화층 형성에 따른 Arc PVD 코팅의 접합특성 평가 (Evaluation of Adhesion Properties of Arc PVD Coatings on Non-Nitrided and Nitrided Various Substrates)

  • 이정민;전성진;고대철;김병민
    • 대한기계학회논문집A
    • /
    • 제30권10호
    • /
    • pp.1179-1186
    • /
    • 2006
  • This paper was designed to assess the adhesive properties of hard coatings on non-nitrided and nitrided various tool steels. Estimations of adhesion were done to scratch test which is mainly used in hard coating. The critical load$(L_c)$ between coating and substrate is defined through analysis of frictional load vs. normal load curve, signals of acoustic emission and optical observations. Coatings employed in this study are TiN, CrN and TiAlN, tools as substrates are STD11, STD61 and SKH51. It was classified to substrates with/without intermediate nitrided layer and hard coatings on substrate were deposited by arc PVD. Results showed that harder substrates and coatings give higher values of critical loads.

접착 면 처리 방법에 따른 이종 압축강도 콘크리트의 접착성능 평가에 관한 실험적 연구 (An Experimental study on bonding performance evaluation of Bi-compressive strength concrete according to surface preparation)

  • 김민성;임희섭;이한승;양원기
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2014년도 춘계 학술논문 발표대회
    • /
    • pp.282-283
    • /
    • 2014
  • An active study on UHPC, which has been recently used in high-rise building and bridges, is in progress. However, research on adhesion strength of normal concrete and UHPC is required to be studied due to the lack of information. In this study, experimental research progress for adhesion strength (shear strength of adhesive surface) evaluation of Bi-compressive strength concretes (UHPC, Normal concrete) is proceeded. First, specimens using glue are produced and surface treatment methods of concrete bonded section are considered. Second, Direct Shear test is applied on concrete bonded section of UHPC (80~180MPa) and Normal Concrete (NC). As a result of this study, it is confirmed that bond strength is deteriorated as the difference of intensity ration of NC and UHPC increases.

  • PDF

역전 유동층에 의한 슬러리아이스 생성에 관한 연구 (A study on formation of slurry ice by the reversing flow)

  • 오철;문성배;최영규
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제30권3호
    • /
    • pp.376-381
    • /
    • 2006
  • This study is experimented to observe an influence of experimental conditions on production characteristics of slurry ice by putting ball into test section to disturb ice adhesion. And at this experiment it used ethylene glycol-water solution and the concentration is 20wt%. The experimental apparatus was constructed of ethylene glycol-water solution and slurry ice storage tank. brine tank, pumps for ethylene glycol-water solution and brine circulating, a mass flow-meter data logger for fluid temperature measuring and a vertical circular tube with two copper tubes as test section. The experiments were carried out under various conditions, with mean velocity of fluid at the entry ranging from 0.07 to 0.13m/s and ball diameter is 10mm, 15mm. Also ball filling rate is 33%, 50%.

역전 유동층 내에서의 슬러리아이스 생성에 관한 실험적 연구 (An experimental study on formation of slurry ice in reversing flow)

  • 최영규;윤석훈;오철
    • 한국마린엔지니어링학회:학술대회논문집
    • /
    • 한국마린엔지니어링학회 2006년도 전기학술대회논문집
    • /
    • pp.49-50
    • /
    • 2006
  • This study experimented to observe an influence of experimental conditions on production characteristics of slurry ice by putting ball into test section to disturb ice adhesion. And at this experiment it used ethylene glycol-water solution and the concentration is 20wt%. The experimental apparatus was constructed of ethylene glycol-water solution and slurry ice storage tank, brine tank. pumps for ethylene glycol-water solution and brine circulating, a mass flow-meter, data logger for fluid temperature measuring and a vertical circular tube with two copper tubes as test section. The experiments were carried out under various conditions, with mean velocity of fluid at the entry ranging from 0.07 to 0.13m/s and ball diameter is 10mm, 15mm. Also ball filling rate is 33%, 50%.

  • PDF