• Title/Summary/Keyword: Additive Drag

Search Result 15, Processing Time 0.018 seconds

The Effects of Copolymer Additives for Drag Reduction on Turbulent Flow (합성고분자첨가제의 난류마찰저항 감소효과 연구)

  • Kim, N.S.;Kim, C.B.;Kim, I.S.;Choi, H.J.
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.5 no.3
    • /
    • pp.207-216
    • /
    • 1993
  • Experimental investigations have been carried out to find the effect of drag reduction caused by effective polymer additives in turbulent flows. The experiments were undertaken with a test section of 9.8mm pipe diameter and 3500 mm pipe length(L/D=357) in a closed loop, and Copolymer-X and Polyacrylamide(PAAM) were used as polymer additives for comparisons. The tests were carried out under different polymer concentrations, and the temperatures of the flow considered were $26^{\circ}C$, $60^{\circ}C$ at the flow velocity of 5.3 m/s. The rate of drag reduction obtained by Copolymer-X is found to be considerably higher than that of PAAM in turbulent flows. Copolymer-X is also found to be very reliable for mechanical degradation, which has not been the case in any other additives. It is concluded that Copolymer-X is considered to be one of the most effective agents as an additive especially for long time hydraulic transports. It is also found that polymer degradation in more likely at lower polymer concentrations in the turbulent flows.

  • PDF

The Effects of Polymer Degradation on the Drag Reduction in CWM Transport (CWM 관수송의 저항 감소현상에 있어서 고분자첨가제의 퇴화 영향에 관한 연구)

  • 송창환;김종보;김인석;최형진
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.16 no.10
    • /
    • pp.1908-1914
    • /
    • 1992
  • A significant drag reduction in the turbulent flow of CWM(coal Water Mixture) adding minute amounts of high molecular weight polymer additives has been obtained and it was compared with pure CWM.However, the rate of drag reduction could come down with flow time, which is caused by polymer degradation, The rate of drag reduction and polymer degradation is affected by polymer type, concentration, molecular weight, and flow velocity. In the present investigation, these important parameters were evaluated for their influences on polymer degradation in order to find out stable conditions for CWM transportation with time. It was necessary to determine the more effective type of polymer additives to guarantee the optimum conditions for CWM transport. Experiments were undertaken with a test section of pipe diameter 9.8mm and pipe length 3500mm(L/D=357) in a closed loop, and polyacrylamide and polyetylene oxide were utilized as polymer additives. The tests were carried out under the conditions of 200, 400, 700ppm of polymer concentrations. CWM concentrations utilized were 5% and 10% with flow velocities of 4.9m/s and 6.1m/s. Experimental data show that polyehylene oxide degraded faster than polyacrylamide in CWM transport, and polyacryamide is considered to be a more effective candidate as additive for long time-CWM transport. Polymer degradation is also found to be more likely at lower polymer concentrations, at higher flow velocities, and higher CWM concentrations.

A PRESSURE DROP MODEL FOR PWR GRIDS

  • Oh, Dong-Seok;In, Wang-Ki;Bang, Je-Geon;Jung, Youn-Ho;Chun, Tae-Hyun
    • Proceedings of the Korean Nuclear Society Conference
    • /
    • 1998.05a
    • /
    • pp.483-488
    • /
    • 1998
  • A pressure drop model for the PWR grids with and without mixing device is proposed at single phase based on the fluid mechanistic approach. Total pressure loss is expressed in additive way for form and frictional losses. The general friction factor correlations and form drag coefficients available in the open literatures are used to the model. As the results, the model shows better predictions than the existing ones for the non-mixing grids, and reasonable agreements with the available experimental data for mixing grids. Therefore it is concluded that the proposed model for pressure drop can provide sufficiently good approximation for grid optimization and design calculation in advanced grid development.

  • PDF

A Comparison Study on Flow-Friction Characteristic of Polymer Solution and Surfactant as Drag Reduction Additive (고분자물질 및 계면활성제의 유동마찰 저감 특성 비교 연구)

  • Ha, Jae-Sun;Ryu, Jae-Sung;Kim, Seong-Su;Cho, Sung-Hwan;Yoon, Seok-Mann;Eom, Jae-Sik
    • Proceedings of the SAREK Conference
    • /
    • 2009.06a
    • /
    • pp.863-868
    • /
    • 2009
  • The drag reduction(DR) for Betaine+Amin and Xantan Gum as kinds of surfactant and Polyacrylamide as kinds of polymer solution according to the fluid velocity, temperature and surfactant concentration were compared experimentally. For this study, two kinds of experimental apparatus for short time and long time measurement were established. Each experimental appratus was equipped with hot water storage tanks, pumps, testing pipe network, flowmeter, two pressure gauges and data logging system was built for them. Results showed that Betaine+Amin and Xanthan Gum as kinds of surfactant had appeared optimal DR around 200-500 ppm and their DR tended to be decreased when flow velocity increased but Polyacrylamide as kinds of polymer solution showed the opposite trend to be increased when flow velocity increased. The both of them showed above 40% DR in the case of better condition by the short term measurement. But Polyacrylamide as kinds of polymer solution showed more degradation than Betaine+Amin and Xanthan Gum as kinds of surfactant by the long term measurement. As a result, Betaine+Amin and Xanthan Gum as kinds of surfactant showed better materials to use to the district heating system.

  • PDF

A Study on Characteristics of Drag Reduction Additive under High Temperature Range (고온영역에서 계면활성제의 마찰저감 성능 특성에 관한 연구)

  • Cho, Sung-Hwan;Ryu, Jae-Sung;Jung, Sang-Hoon
    • Journal of Energy Engineering
    • /
    • v.19 no.2
    • /
    • pp.116-120
    • /
    • 2010
  • Overall total length of hydraulic pipe to transport the hot water in the domestic district heating network is above 3,000 Km approximately. This long pipe network requires a lots of the transport pumping power by surface friction of fluid. In this study, the drag reduction(DR) of Amin Oxide $C_{18}$ as non-ionic surfactant according to the fluid velocity, temperature and surfactant concentration under the condition of above $80^{\circ}C$ fluid temperature were investigated experimentally. Results showed that new amin oxide $C_{18}$ surfactant had DR of maximum 30% in fluid temperature of $80^{\circ}C$ and had 15% DR in fluid temperature over $100^{\circ}$ under short time test condition. And amine oxide had 155 hours duration time to keep the DR characteristic in the fluid temperature of $80^{\circ}$ and 1000 ppm concentration. But duration time of DR was decreased when fluid temperature increased.