• Title/Summary/Keyword: Acute Exposure Guideline Level

Search Result 7, Processing Time 0.022 seconds

Estimation of Temporal Acute Exposure Guideline Levels for Emergency Response - A Brief Case using Formaldehyde - (화학사고 대응을 위한 시간별 급성노출기준 참고치 산정 - 폼알데하이드 사례 -)

  • Kim, Eunchae;Cho, Yong-Sung;Lee, Chung-Soo;Yang, Wonho;Hwang, Seung-Ryul;Park, Jihoon
    • Journal of Environmental Health Sciences
    • /
    • v.47 no.2
    • /
    • pp.166-174
    • /
    • 2021
  • Objectives: This study aimed to provide temporal Acute Exposure Guideline Levels (AEGL) for a hazardous substance as a pilot study. Methods: As one of the substances designated by the Korea Ministry of Environment as requiring preparations for potential accidents, formaldehyde was selected to estimate the AEGLs. The calculation was based on Haber's formula (Cn×t=k) using valid toxicity data (for humans/animals). A total of 96 points of AEGL levels were provided using an interval of five minutes over eight hours. Results: The AEGL-1 and 2 values were constant for the entire exposure duration at 0.9 ppm and 14 ppm, respectively. The values were obtained from clinical/animal tests, and the adaptation effect after a given exposure duration was also considered. AEGL-3 was based on animal toxicity data, and it was estimated from 127 ppm for the initial five minutes to 35 ppm for eight hours. Conclusions: More specific AEGL levels for formaldehyde could be obtained in this study using toxicity data with Haber's formula. Based on this methodology, it would be also possible to estimate AEGL levels that can be used at the scene of a chemical accident for other substances requiring preparation for potential accidents.

Toxic Concentration(T-LOC) Endpoint Distance Study for Fire Brigade Protection in Response to Chemical Accidents (화학사고 초기대응 소방대 보호를 위한 독성농도(T-LOC) 끝점거리 연구)

  • Jong Chan Yun;Chul Hee Cho;Jeong Hun Won
    • Journal of the Korean Society of Safety
    • /
    • v.38 no.6
    • /
    • pp.60-71
    • /
    • 2023
  • The purpose of this study is to propose a quantitative toxicity endpoint distance suitable for the initial response of firefighters by comparing and analyzing the commonly applied toxic level of concern (T-LOC), specifically emergency response planning guidelines (ERPG), acute exposure guideline levels (AEGL), and immediately dangerous to life or health (IDLH). This is to protect the fire brigade, which responds to toxic chemical accidents first during the golden time. Using areal locations of hazardous atmospheres, a damage prediction program, the amount of leakage for both acidic and basic substances, along with the endpoint distance, were analyzed for alternative accident and worst-case accident scenarios. The results showed that the toxicity endpoint distance, serving as a compromise between Level-3 and Level-2 of T-LOC, was longer than ERPG-3 and shorter than ERPG-2 with IDLH, while its values were analyzed in the order of ERPG-2, AEGL-2, IDLH, AEGL-3, and ERPG-3. It is suggested that the application of IDLH in an emergency (red card) and ERPG-2 endpoint distance in a non-emergency (non-red card) can be utilized for the initial response of the fire brigade.

Indoor Exposure and Health Risk of Polycyclic Aromatic Hydrocarbons (PAHs) via Public Facilities PM2.5, Korea (II)

  • Kim, Ho-Hyun;Lee, Geon-Woo;Yang, Ji-Yeon;Jeon, Jun-Min;Lee, Woo-Seok;Lim, Jung-Yun;Lee, Han-Seul;Gwak, Yoon-Kyung;Shin, Dong-Chun;Lim, Young-Wook
    • Asian Journal of Atmospheric Environment
    • /
    • v.8 no.1
    • /
    • pp.35-47
    • /
    • 2014
  • The purpose of the study is to evaluate the pollution level (gaseous and particle phase) in the public facilities for the PAHs, non-regulated materials, forecast the risk level by the health risk assessment (HRA) and propose the guideline level. PAH assessments through sampling of particulate matter of diameter < 2.5 ${\mu}m$ ($PM_{2.5}$). The user and worker exposure scenario for the PAHs consists of 24-hour exposure scenario (WIES) assuming the worst case and the normal exposure scenario (MIES) based on the survey. This study investigated 20 PAH substances selected out of 32 substances known to be carcinogenic or potentially carcinogenic. The risk assessment applies major toxic equivalency factor (TEF) proposed from existing studies and estaimates individual Excess Cancer Risk (ECR). The study assesses the fine dusts ($PM_{2.5}$) and the exposure levels of the gaseous and particle PAH materials for 6 spots in each 8 facility, e.g. underground subway stations, child-care facilities, elderly care facilities, super market, indoor parking lot, terminal waiting room, internet caf$\acute{e}$ (PC-rooms), movie theater. For internet caf$\acute{e}$ (PC-rooms) in particular, that marks the highest $PM_{2.5}$ concentration and the average concentration of 10 spots (2 spots for each cafe) is 73.3 ${\mu}g/m^3$ (range: 6.8-185.2 ${\mu}g/m^3$). The high level of $PM_{2.5}$ seen in internet cafes was likely due to indoor smoking in most cases. For the gaseous PAHs, the detection frequency for 4-5 rings shows high and the elements with 6 rings shows low frequency. For the particle PAHs, the detection frequency for 2-3 rings shows low and the elements with 6 rings show high frequency. As a result, it is investigated that the most important PAHs are the naphthalene, acenaphthene and phenanthrene from the study of Kim et al. (2013) and this annual study. The health risk assessment demonstrates that each facility shows the level of $10^{-6}-10^{-4}$. Considering standards and local source of pollution levels, it is judged that the management standard of the benzo (a)pyrene, one of the PAHs, shall be managed with the range of 0.5-1.2 $ng/m^3$. Smoking and ventilation were considered as the most important PAHs exposure associated with public facility $PM_{2.5}$. This study only estimated for inhalation health risk of PAHs and focused on the associated cancer risk, while multiple measurements would be necessary for public health and policy.

Toxicological Effects of PFOS and PFOA on Earthworm, Eisenia fetida

  • Joung, Ki-Eun;Jo, Eun-Hye;Kim, Hyun-Mi;Choi, Kyung-Hee;Yoon, Jun-Heon
    • Environmental Analysis Health and Toxicology
    • /
    • v.25 no.3
    • /
    • pp.181-186
    • /
    • 2010
  • Perfluorinated Compounds (PFCs) are anthropogenic compounds found in trace amounts in many environmental compartments far from areas of production. Along with the highly persistent nature of PFCs, there are increasing concerns over the potential adverse effects of them on the ecosystems. Most of highly fluorinated compounds degrade into PFOS and PFOA that are very stable compounds hard to break down. So, in this study, we tried to determine the toxicity of PFOS and PFOA in the terrestrial invertebrate. Acute toxicity test using earthworm, Eisenia fetida, was performed according to the OECD test guideline 207 (Earthworm, Acute Toxicity Tests). In the 14 day acute toxicity tests, the highest concentration causing no mortality and the lowest concentration causing 100% mortality of PFOS were 160 and 655 mg/kg (dry weight), respectively. And the highest concentration causing no mortality and the lowest concentration causing 100% mortality were 500 and 1,690 mg/kg (dry weight), respectively in the PFOA-exposure group. 14 day-LC50 values were estimated at the level of 365 and 1,000 mg/kg (dry weight) in the PFOS and PFOA-exposed group. These results indicate that under laboratory conditions PFOS is about 3 times more toxic to earthworms than PFOA. Based on known environmental concentrations of PFOS in the soil of Korea, which occur in the 0.42~0.73 ng/L range, there is no apparent risk to terrestrial invertebrate, earthworms. However, further work is required to investigate long-term effects on these and other terrestrial organisms.

Improvement Plan for Prevention Regulations to Improve Hazardous Material Safety Management

  • Seongju Oh;Jaewook Lee;Hasung Kong
    • International Journal of Advanced Culture Technology
    • /
    • v.11 no.3
    • /
    • pp.346-357
    • /
    • 2023
  • The purpose of this study is to suggest improvement plans for prevention regulations by reflecting the toxicity, fire and explosion effects of hazardous materials factories and surrounding areas using an off-site consequence assessment program. Regarding the effects of the hydrogen cyanide leak accident, which is the 1st petroleum of the 4th class flammable liquid, Areal Locations of Hazardous Atmospheres (ALOHA) program was used to compare and analyze the extent of damage effects for toxicity, overpressure, and radiation. As a result, the toxicity was analyzed to exceed 5km in the area with Acute exposure guideline level (AEGL)-2 concentration or higher, the overpressure was 103m in the range of 1 psi or more, and the radiant heat was analyzed to be 724m in the range of 2kw/m2 or more. Toxicity and radiation affected the area outside the hazardous material storage area, but the overpressure was limited to the inside of the hazardous material storage area. Therefore, we propose to improve the safety management of hazardous materials by conducting a risk assessment for hazardous materials and reflecting the results in internal and external emergency response plans to prepare prevention regulations.

Study on the Consequence Effect Analysis & Process Hazard Review at Gas Release from Hydrogen Fluoride Storage Tank (최근 불산 저장탱크에서의 가스 누출시 공정위험 및 결과영향 분석)

  • Ko, JaeSun
    • Journal of the Society of Disaster Information
    • /
    • v.9 no.4
    • /
    • pp.449-461
    • /
    • 2013
  • As the hydrofluoric acid leak in Gumi-si, Gyeongsangbuk-do or hydrochloric acid leak in Ulsan, Gyeongsangnam-do demonstrated, chemical related accidents are mostly caused by large amounts of volatile toxic substances leaking due to the damages of storage tank or pipe lines of transporter. Safety assessment is the most important concern because such toxic material accidents cause human and material damages to the environment and atmosphere of the surrounding area. Therefore, in this study, a hydrofluoric acid leaked from a storage tank was selected as the study example to simulate the leaked substance diffusing into the atmosphere and result analysis was performed through the numerical Analysis and diffusion simulation of ALOHA(Areal Location of Hazardous Atmospheres). the results of a qualitative evaluation of HAZOP (Hazard Operability)was looked at to find that the flange leak, operation delay due to leakage of the valve and the hose, and toxic gas leak were danger factors. Possibility of fire from temperature, pressure and corrosion, nitrogen supply overpressure and toxic leak from internal corrosion of tank or pipe joints were also found to be high. ALOHA resulting effects were a little different depending on the input data of Dense Gas Model, however, the wind direction and speed, rather than atmospheric stability, played bigger role. Higher wind speed affected the diffusion of contaminant. In term of the diffusion concentration, both liquid and gas leaks resulted in almost the same $LC_{50}$ and ALOHA AEGL-3(Acute Exposure Guidline Level) values. Each scenarios showed almost identical results in ALOHA model. Therefore, a buffer distance of toxic gas can be determined by comparing the numerical analysis and the diffusion concentration to the IDLH(Immediately Dangerous to Life and Health). Such study will help perform the risk assessment of toxic leak more efficiently and be utilized in establishing community emergency response system properly.

Methodology on the Safety Goal Setting of Reactor Operation based on the Radiogenic Excess Cancer Risk in Korea (한국인의 초과 방사선 암 위험도 평가에 근거한 국내원전의 안전목표치 설정 방법론)

  • Chang, Si-Young;Chung, Woon-Kwan
    • Journal of Radiation Protection and Research
    • /
    • v.24 no.3
    • /
    • pp.131-142
    • /
    • 1999
  • By using the Korean demographic data and the modified relative risk projection model given in the Committee on the Biological Effect of Ionizing Radiation (BEIR) report-V under the U.S. National Academy of Science, the radiogenic excess risk in Korean population has been evaluated. On the basis of this risk, a safety goal for the safe operation of domestic nuclear power plants has been further derived in terms of personal dose. The baseline risk of death due to all causes in Korea and the trivial risk level, which the society considers safe, were estimated to be $5.2{\times}10^{-3}$ and $5.2{\times}10^{-6}$, respectively. The radiogenic excess cancer risk in Korea has been estimated to be $5.2{\times}10^{-3}$ for tie case of acute exposure to 0.1 Gy and $3.7{\times}10^{-3}$ for the case of chronic lifetime exposure to 1.0 mGy/y. On the basis of these risks estimate, the resulting safety goal for one year opeation of a reactor was 0.05 mSv, which is quite identical with the ALARA guideline prescribed by the USNRC in the Appendix I, 10CFR50.

  • PDF