Dosimetric Comparison between Varian Halcyon Analytical Anisotropic Algorithm and Acuros XB Algorithm for Planning of RapidArc Radiotherapy of Cervical Carcinoma

  • Mbewe, Jonathan;Shiba, Sakhele
    • 한국의학물리학회지:의학물리
    • /
    • 제32권4호
    • /
    • pp.130-136
    • /
    • 2021
  • Purpose: The Halcyon radiotherapy platform at Groote Schuur Hospital was delivered with a factory-configured analytical anisotropic algorithm (AAA) beam model for dose calculation. In a recent system upgrade, the Acuros XB (AXB) algorithm was installed. Both algorithms adopt fundamentally different approaches to dose calculation. This study aimed to compare the dose distributions of cervical carcinoma RapidArc plans calculated using both algorithms. Methods: A total of 15 plans previously calculated using the AAA were retrieved and recalculated using the AXB algorithm. Comparisons were performed using the planning target volume (PTV) maximum (max) and minimum (min) doses, D95%, D98%, D50%, D2%, homogeneity index (HI), and conformity index (CI). The mean and max doses and D2% were compared for the bladder, bowel, and femoral heads. Results: The AAA calculated slightly higher targets, D98%, D95%, D50%, and CI, than the AXB algorithm (44.49 Gy vs. 44.32 Gy, P=0.129; 44.87 Gy vs. 44.70 Gy, P=0.089; 46.00 Gy vs. 45.98 Gy, P=0.154; and 0.51 vs. 0.50, P=0.200, respectively). For target min dose, D2%, max dose, and HI, the AAA scored lower than the AXB algorithm (41.24 Gy vs. 41.30 Gy, P=0.902; 47.34 Gy vs. 47.75 Gy, P<0.001; 48.62 Gy vs. 50.14 Gy, P<0.001; and 0.06 vs. 0.07, P=0.002, respectively). For bladder, bowel, and left and right femurs, the AAA calculated higher mean and max doses. Conclusions: Statistically significant differences were observed for PTV D2%, max dose, HI, and bowel max dose (P>0.05).

비편평화여과기 빔을 이용한 폐 정위절제방사선치료를 위한 AAA와 Acuros XB 계산 알고리즘의 치료계획 비교 (Comparison of Anisotropic Analytic Algorithm Plan and Acuros XB Plan for Lung Stereotactic Ablative Radiotherapy Using Flattening Filter-Free Beams)

  • 정진범;엄근용;김인아;김재성;이정우;홍세미;김연래;박병문;강상원;서태석
    • 한국의학물리학회지:의학물리
    • /
    • 제25권4호
    • /
    • pp.210-217
    • /
    • 2014
  • 이 연구는 비편평화여과기(flattening filter-free, FFF) 빔을 이용한 폐 정위절제방사선치료(stereotactic ablative radiotherapy, SABR)에 대하여 서로 다른 선량계산 알고리즘의 선량적 효과를 조사하였다. SABR를 받은 10명의 폐암 환자를 대상으로하여 평가하였다. 모든 치료계획은 Eclipse 치료계획시스템의 Acuros XB (AXB) 알고리즘을 이용하여 수립되었다. 다른 선량계산 알고리즘과 비교를 위하여, 추가적으로 anisotropic analytic algorithm (AAA) 알고리즘을 적용한 치료계획을 재 수립하였다. 두 알고리즘 평가를 위해서, 치료표적과 손상위험장기의 선량체적히스토그램(dose-volume histogrim, DVH)를 분석하였다. 그리고 기술적 인자로써 계산시간과 총 MU 값을 평가하였다. DVH 비교분석을 통해, PTV의 최대선량은 AXB이 AAA 보다 5.2% 높았으며 최소선량은 4.4% 낮게 나타났다. PTV의 $V_{105%}$에서 7.06%까지 큰 차이를 나타났다. 폐의 최대선량은 AXB 치료계획에서 약간 크게 나타났다. 동측성 폐에 5, 10과 20 Gy 선량이 조사되는 체적은 AAA 보다 AXB에서 더 크게 나타났으나 대측성 폐에 대해서는 거의 비슷하게 나타났다. 척수와 심장에서 최대선량의 차이도 크지 않았다. 계산시간의 경우, AXB가 AAA보다 13.7% 정도 소요시간이 적었고 MU 값은 AXB에서 3.47% 더 많았다. 이 연구의 결과들은 회전조절치료 기법을 포함하여 FFF 빔이 적용된 폐 SABR 치료계획에서 AXB 알고리즘은 선량계산의 정확성과 계산시간의 감소의 장점을 제공할 수 있을 것이다.

Dosimetric Validation of the Acuros XB Advanced Dose Calculation Algorithm for Volumetric Modulated Arc Therapy Plans

  • Park, So-Yeon;Park, Jong Min;Choi, Chang Heon;Chun, Minsoo;Kim, Jung-in
    • 한국의학물리학회지:의학물리
    • /
    • 제27권4호
    • /
    • pp.180-188
    • /
    • 2016
  • Acuros XB advanced dose calculation algorithm (AXB, Varian Medical Systems, Palo Alto, CA) has been released recently and provided the advantages of speed and accuracy for dose calculation. For clinical use, it is important to investigate the dosimetric performance of AXB compared to the calculation algorithm of the previous version, Anisotropic Analytical Algorithm (AAA, Varian Medical Systems, Palo Alto, CA). Ten volumetric modulated arc therapy (VMAT) plans for each of the following cases were included: head and neck (H&N), prostate, spine, and lung. The spine and lung cases were treated with stereotactic body radiation therapy (SBRT) technique. For all cases, the dose distributions were calculated using AAA and two dose reporting modes in AXB (dose-to-water, $AXB_w$, and dose-to-medium, $AXB_m$) with same plan parameters. For dosimetric evaluation, the dose-volumetric parameters were calculated for each planning target volume (PTV) and interested normal organs. The differences between AAA and AXB were statistically calculated with paired t-test. As a general trend, $AXB_w$ and $AXB_m$ showed dose underestimation as compared with AAA, which did not exceed within -3.5% and -4.5%, respectively. The maximum dose of PTV calculated by $AXB_w$ and $AXB_m$ was tended to be overestimated with the relative dose difference ranged from 1.6% to 4.6% for all cases. The absolute mean values of the relative dose differences were $1.1{\pm}1.2%$ and $2.0{\pm}1.2%$ when comparing between AAA and $AXB_w$, and AAA and $AXB_m$, respectively. For almost dose-volumetric parameters of PTV, the relative dose differences are statistically significant while there are no statistical significance for normal tissues. Both $AXB_w$ and $AXB_m$ was tended to underestimate dose for PTV and normal tissues compared to AAA. For analyzing two dose reporting modes in AXB, the dose distribution calculated by $AXB_w$ was similar to those of AAA when comparing the dose distributions between AAA and $AXB_m$.

폐암 SBRT에서 호흡동조 VMAT의 정확성 분석을 위한 새로운 4D 팬텀 모델 개발 (Development of New 4D Phantom Model in Respiratory Gated Volumetric Modulated Arc Therapy for Lung SBRT)

  • 윤경준;곽정원;조병철;송시열;이상욱;안승도;남상희
    • 한국의학물리학회지:의학물리
    • /
    • 제25권2호
    • /
    • pp.100-109
    • /
    • 2014
  • 정위신체방사선치료(SBRT)에서 환자의 호흡에 대한 정확한 치료위치의 확보는 필수적으로 고려되어야 하며 그 정확성에 관련하여 많은 연구들이 진행되어왔다. 본 연구에서는 실제 호흡에 의한 움직임과 실제 환자 폐의 형태를 고려한 팬텀실험으로 실제 치료에서 일어나는 임상적 상황을 모사함으로 호흡 동조 부피적조절회전 방사선치료(Volumeric Modulated Arc Therapy, VMAT) 기법을 이용한 폐부 SBRT의 정확성을 분석하는 방법을 제시하고자 하였다. SBRT을 받은 폐암 환자의 CT 영상을 기반으로 3D 프린터를 이용하여 치료부위와 유사하게 폐 팬텀을 제작하였고 환자 호흡과 동일하게 움직임을 재현할 수 있도록 $QUASAR^{TM}$ 호흡 동조 구동 팬텀(Modus Medical Devices, London, Canada)에 장착하여 호흡동조 VMAT에서의 2차원 선량 분포를 평가할 수 있는 시스템을 구축하였다. 폐 팬텀은 종양부위를 중심으로 2등분하여 EBT3 필름을 삽입하고 선량분포를 측정할 수 있도록 제작되었다. 비균질 조건에서의 선량계산의 정확성을 확인하기 위하여 균질한 플라스틱 팬텀과 제작된 비균질 폐 팬텀에서 Analytical Anisotropic Algorithm (AAA)와 AcurosXB (AXB) 두가지 알고리즘으로 선량계산을 하여 비교, 분석하였다. 움직임에 대한 치료의 정확성을 평가하기 위하여 호흡동조와 비 호흡동조의 경우, 그리고 움직임이 없는 조건에서 선량분포를 취득하여 치료계획 선량에 대한 감마지표를 분석하였다. 치료부위 GTV에서의 CT number는 실제 환자의 경우 78 HU를 나타내었고 모사된 폐 팬텀의 경우 92 HU를 나타내었다. 팬텀 내 폐 조직부분은 3D프린터로 적층하는 과정에서 격자구조의 형태를 이용하여 구현하였다. 측정된 필름선량은 AAA 알고리즘을 이용한 치료계획 선량에 대하여 움직이는 팬텀에서 호흡동조의 유무에 따라 3%/3 mm 감마지표 조건하에서 각각 88%와 78%의 감마합격률을 나타내었으며, 움직임이 없는 경우 95% 이상의 감마합격률을 보였다. AXB 알고리즘을 적용하였을 경우에는 모든 경우에서 98% 이상의 합격률을 나타내었다. 균질한 플라스틱 팬텀에 대하여 측정하였을 때 두가지 선량계산 알고리즘을 포함한 모든 조건에서 99% 이상의 감마합격률을 나타내었다. 선택된 환자의 호흡 진폭이 비교적 작고 inhale보다는 exhale에 더 오래 머무르는 호흡패턴 때문에 3%/3 mm 감마 기준에서는 호흡에 따른 차이가 거의 나타나지 않은 것으로 이해되었다. 선량계산의 정확성에서는 AAA 알고리즘을 적용하였을 때보다 AXB 알고리즘을 적용하였을 때가 균질과 비균질 환경에서의 선량 분포에 따른 감마 합격률의 차이가 적게 나타남을 확인 할 수 있었다. 본 논문에서는 환자와 유사하게 제작된 폐 팬텀에 실제 환자 호흡 패턴을 연동함으로 새로운 4D 치료선량 분포 검증 방법을 제시하였고 보다 사실적인 선량분포를 반영한 개별 환자 치료의 정확성 검증이 가능할 것으로 평가되었다.

The Accuracy of the Calculated Dose for a Cardiac Implantable Electronic Device

  • Sung, Jiwon;Son, Jaeman;Park, Jong Min;Kim, Jung-in;Choi, Chang Heon
    • 한국의학물리학회지:의학물리
    • /
    • 제30권4호
    • /
    • pp.150-154
    • /
    • 2019
  • The objective of this study is to monitor the radiation doses delivered to a cardiac implantable electronic device (CIED) by comparing the absorbed doses calculated by a commercial treatment planning system (TPS) to those measured by an in vivo dosimeter. Accurate monitoring of the radiation absorbed by a CIED during radiotherapy is necessary to prevent damage to the device. We conducted this study on three patients, who had the CIED inserted and were to be treated with radiotherapy. Treatment plans were generated using the Eclipse system, with a progressive resolution photon optimizer algorithm and the Acuros XB dose calculation algorithm. Measurements were performed on the patients using optically stimulated luminescence detectors placed on the skin, near the CIED. The results showed that the calculated doses from the TPS were up to 5 times lower than the measured doses. Therefore, it is recommended that in vivo dosimetry be conducted during radiotherapy for CIED patients to prevent damage to the CIED.

Feasibility Study of Mobius3D for Patient-Specific Quality Assurance in the Volumetric Modulated Arc Therapy

  • Lee, Chang Yeol;Kim, Woo Chul;Kim, Hun Jeong;Lee, Jeongshim;Huh, Hyun Do
    • 한국의학물리학회지:의학물리
    • /
    • 제30권4호
    • /
    • pp.120-127
    • /
    • 2019
  • Purpose: This study was designed to evaluate the dosimetric performance of Mobius3D by comparison with an aSi-based electronic portal imaging device (EPID) and Octavius 4D, which are conventionally used for patient-specific prescription dose verification. Methods: The study was conducted using nine patients who were treated by volumetric modulated arc therapy. To evaluate the feasibility of Mobius3D for prescription dose verification, we compared the QA results of Mobius3D to an aSi-based EPID and the Octavius 4D dose verification methods. The first was the comparison of the Mobius3D verification phantom dose, and the second was to gamma index analysis. Results: The percentage differences between the calculated point dose and measurements from a PTW31010 ion chamber were 1.6%±1.3%, 2.0%±0.8%, and 1.2%±1.2%, using collapsed cone convolution, an analytical anisotropic algorithm, and the AcurosXB algorithm respectively. The average difference was found to be 1.6%±0.3%. Additionally, in the case of using the PTW31014 ion chamber, the corresponding results were 2.0%±1.4%, 2.4%±2.1%, and 1.6%±2.5%, showing an average agreement within 2.0%±0.3%. Considering all the criteria, the Mobius3D result showed that the percentage dose difference from the EPID was within 0.46%±0.34% on average, and the percentage dose difference from Octavius 4D was within 3.14%±2.85% on average. Conclusions: We conclude that Mobius3D can be used interchangeably with phantom-based dosimetry systems, which are commonly used as patient-specific prescription dose verification tools, especially under the conditions of 3%/3 mm and 95% pass rate.

Small sized lung SBRT 치료시 폐 실질 조직에서의 계획선량 전달 정확성 평가 (Evaluation of beam delivery accuracy for Small sized lung SBRT in low density lung tissue)

  • 오혜경;손상준;박장필;이제희
    • 대한방사선치료학회지
    • /
    • 제31권1호
    • /
    • pp.7-15
    • /
    • 2019
  • 목 적: 본 연구에서는 lung SBRT가 적용되는 작은 계획 표적 용적(PTV)에 처방 선량이 정확히 전달되는지 실험을 통하여 알아보고자 한다. 치료계획 시스템에서 계산된 선량분포와 실험을 통하여 필름에 측정된 선량분포를 비교 분석하여 정확성을 평가해보고, 폐 실질 조직 내에서 계획 표적 용적의 margin 유용성 평가를 하고자 한다. 대상 및 방법: CT 촬영으로 얻은 Rando phantom 3D 영상의 우측 폐에 직경 2, 3, 4, 5 cm인 가상의 구 표적을 만들어 계획 표적 용적에 처방선량의 95 %가 전달될 수 있도록 6MV-FFF VMAT Arc 2개로 치료계획을 수립하였으며, Eclipse TPS와 동일한 위치에서 선량 비교하기 위해서, 필름을 가상 표적의 회전중심점에 횡단면 방향으로 삽입하고 방사선을 조사하였다. Dose profile을 Eclipse에서 획득하고, 측정값과 계산값을 비교하기 위해 Center point에서의 절대 선량값을 계산하였으며, off-axis 선량 분포를 얻어 RMSE, Coverage ratio 등 비교 인자를 통해 상대 선량 및 선량분포를 비교 분석하였다. 결 과: 직경 2, 3, 4, 5 cm 크기별로 center point에서의 %difference 값은 직경 2 cm에서 -4.65 %로 가장 차이가 큰 값을 보였고, 직경 5 cm일 때 -1.46 %로 가장 차이가 작은 값을 보였다. RMSE값은 직경 2 cm일 때 3.43으로 가장 큰 값을 보였고. 직경 5 cm일 때 2.85로써 가장 작은 값을 보였다. 표적 커버리지를 비교하기 위해 처방선량 95 %가 들어가는 용적의 길이($D_{95}$)를 구하였고, 직경 2 cm일 때, TPS와 필름에서 각각 2.02 cm, 1.86 cm로 커버리지 비율이 92 %로 나타났고 가장 큰 차이를 보였다. 또한 계획 표적 용적 100% 이내에 들어가는 평균선량($D_{mean}$)을 비교했을 때, 직경 2 cm 인 경우 측정 평균선량이 95.72 %로 가장 낮은 값을 보였다. 결 론: 본 연구에서는 실험을 통하여 작은 계획 표적 용적에 처방 선량이 충분히 전달되는지 알아보았다. 실험 결과 모든 비교 인자에서 직경 2 cm인 용적이 가장 큰 차이를 보였다. 이는 표적 용적 중심에서의 선량 감소가 주요인이라 판단된다. 따라서 선량계산 시스템에서 저밀도 조직 내의 작은 용적 치료 계획시 2 mm 이상의 마진(margin)을 더 두거나, 치료 계획 최적화(optimization)시 최대선량을 제한하지 않는 방법으로 표적 내 중심 선량을 높일 수 있을 것이라 사료된다.

비인두암 Vertical MLC VMAT plan 유용성 평가 (Evaluating efficiency of Vertical MLC VMAT plan for naso-pharyngeal carcinoma)

  • 채승훈;손상준;이제희
    • 대한방사선치료학회지
    • /
    • 제33권
    • /
    • pp.127-135
    • /
    • 2021
  • 목 적 : 비인두암 VMAT 치료 시 콜리메이터 각도 273°와 350°를 사용한 2회전 치료계획(Vertical MLC VMAT plan, 이하 VMV plan)과 콜리메이터 각도 20°와 340°를 사용한 2회전 치료계획(Complemental MLC VMAT plan, 이하 CMV plan)과의 비교 분석을 통해 유용성을 평가해 보고자 한다. 대상 및 방법 : 본원에서 VMAT 치료를 받은 비인두암 환자 30명을 대상으로 하였다. 전산화치료계획은 Eclipse, PO, AcurosXB 알고리즘을 이용하였으며, 치료기는 Vital-beam을 사용하였다. 치료계획은 갠트리 회전반경이 각각 360°인 두 개의 회전(Arc)을 6MV를 이용하여 생성하고, 콜리메이터 각도 변화에 의한 영향을 확인하기 위해 273°와 350°로 설정한 VMV plan과 20°와 340°로 설정한 CMV plan을 수립하였다. 선량용적 히스토그램에서 확인 및 산출된 계획표적용적(PTV)과 결정장기(OAR)들의 선량지표들과 변조복잡성지수(MCSv), MU, 치료시간에 대해 기술통계 및 대응표본 t-검정을 실시하였다. 그리고 대상별로 두 치료계획의 MCSv의 차이와 각각의 평가지표들의 차이 간 상관관계가 있는지 확인하기 위해 피어슨의 상관관계 분석을 실시하였다. 결 과 : PTV 평가 지표의 경우, VMV Plan에서 PTV_67.5의 CI가 3.76% 개선되었으며, OAR의 경우 척수(-14.05%)와 뇌 줄기(-9.34%)의 선량감소 효과가 두드러지게 나타났다. 그리고 귀밑샘들(왼쪽 : -5.38%, 오른쪽 : -5.97%)과, 시각기관들(왼쪽 시신경 : -4.88%, 오른쪽 시신경 : -5.80%, 시신경교차 : -6.12%, 왼쪽 수정체 : -6.12%, 오른쪽 수정체 : -5.26%), 청각기관(왼쪽 : -11.74%, 오른쪽 : -12.31%)과 갑상샘(-2.02%)에서의 선량감소효과도 확인할 수가 있었다. 또한 MCSv가 VMV Plan에서 5.31% 높게 나왔으며, MU의 경우에 6.11% 낮은 것으로 나타났다. 그리고 두 치료계획의 MCSv의 차이는 PTV_54의 CI(r=-0.55)의 차이, PTV_48의 CI(r=-0.43)의 차이와 유의한 음(-)의 상관관계를 보였고, 척수(r=0.40), 뇌줄기(r=0.34), 양쪽 침샘들(왼쪽 : r=0.36, 오른쪽 : r=0.37)의 차이와 양(+)의 상관관계를 보였다. 이는 VMV plan의 moluation 복잡성이 CMV plan에 비해 상대적으로 높아 질 때, PTV_54, 48의 CI 개선 및 척수, 뇌줄기, 양쪽침샘들의 선량 감소 효과가 커지는 것을 의미하며, 이러한 분석결과들을 바탕으로 VMV plan의 modulation에 대한 효율성이 CMV plan 보다 크다는 것을 확인할 수 있었다. (위 모든 값에 대해 유의수준은 p<.05) 결 론 : VMV Plan은 CMV plan과 비교하여 MLC가 더 효율적으로 modulation할 수 있도록 함으로써, 치료계획의 질을 향상 시키는데 도움이 될 것이라 사료된다.