• Title/Summary/Keyword: Actual Measurement

Search Result 1,779, Processing Time 0.033 seconds

A study on the Intake-Balance of Iron Copper and Cobalt of College men in Korea (한국 남자대학생의 Iron, Copper 및 Cobalt 섭취량과 평형에 관한연구)

  • 최인선;장수영;오승호
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.19 no.5
    • /
    • pp.418-428
    • /
    • 1990
  • This study measured each daily intake and excretion of iron copper and cobalt of eight 20-26 years old college men during four weeks by means of analyzing their food intake urine and feces keeping their normal living pattern and maintenance body weight. This study also compared the actual measurement value of iron intake by atomic absorption spectrophoto-meter with the conversion value of it by food table. The results were as follows. Each person's average intake daily was iron 9.19±0.32mg/day, copper 0.56±0.06mg/day and cobalt 1.86±0.18mg/day. Each person's average urinary excretion daily was iron 0.53±0.07mg/day, copper 0.07±0.03mg/day and cobalt 0.13±0.01mg/day. Each person's average fecal excretion daily was iron 1.73±0.14mg/day copper 0.16±0.01mg/day and cobalt 0.46±0.08mg/day. The actual measurement value was 9.19±0.32mg/day and its conversion value 14.07±0.29mg/day : the former was 35% lower than the latter.

  • PDF

A Study on the Model of Training Performance Measurement Specialized to Cyber Security Trainee for Cyber Security Professionals Acquisition (사이버보안 전문인력 획득을 위한 사이버보안 훈련생에 특화된 훈련성과 측정 모델에 관한 연구)

  • Kim, Kihoon;Eom, Jungho
    • Journal of Korea Society of Digital Industry and Information Management
    • /
    • v.12 no.4
    • /
    • pp.59-69
    • /
    • 2016
  • We proposed a specialized model of performance measurement to measure the training performance of the trainees in cyber practical training. Cyber security professionals are cultivating their expertise, skills, and competencies through cyber practical training in specialized education and training institutions. The our proposed process of trainee evaluation is consisted of an evaluation component discovery, evaluation item selection, evaluation index catalog, ratings and criteria decision, and calculation formula. The trainee evaluation is consisted of a formative evaluation during the training and an overall evaluation after finished training. Formative evaluation includes progress evaluation and participation evaluation, and overall evaluation includes practice evaluation and learning evaluation. The evaluation is weighted according to the importance of evaluation type. Because it is evaluated actual skills and abilities, competencies are assigned a high weight, while knowledge and attitudes are assigned a low weight. If cyber security trainees are evaluated by the proposed evaluation model, cyber security professionals can be cultivated by each skill and knowledge level and can be deployed by importance of security task.

A Study on the Distribution Stresses beneath Loaded Ground Surface Area of Double Strata Ground on Soft Clay Layers (연약점토층위 이층지반 지표면 재하시 지중응력 특성연구)

  • Lee, In-Hyung;Lim, Jong-Seok
    • Journal of The Korean Society of Agricultural Engineers
    • /
    • v.47 no.6
    • /
    • pp.47-57
    • /
    • 2005
  • Stress distribution in soils is the very important element to design and to solve the problems of settlement, safety of foundations and trafficability of constructing vehicle in civil engineering. This research presents the comparative estimation of the actual and theoretical measurement on the underground stress of outer layer for each soil after the observation of each top soil layer fur its vertical and horizontal stresses in (1) homogeneous sand ground (2) weak stratum with the sand soil (3) weak stratum with gravel of the soil model, and it also investigates the effect of subsidence of ground by the repeated load. The underground stresses fumed out to be different in the value of theoretical and actual measurement after the trial examination of model. This study has the purpose of suggesting the better construction method of running equipment on weak stratum by comparing the estimated value of trial experiment and theory on underground stress of the weak ground surface area and of raising up the necessity of the continuous research hereafter.

A Study on Earned Value Management System (EVMS) For Project Using ERP System (ERP 시스템을 이용한 프로젝트 EVMS에 관한 연구)

  • Park, Je-Won;Lee, Chang-Ho
    • Journal of the Korea Safety Management & Science
    • /
    • v.12 no.4
    • /
    • pp.145-151
    • /
    • 2010
  • It seems that a primary concern of the project-based company, which provides a large scale product or service over long term period, is to run a successful project through systematic project process control and control costs. One of the typical project control methods is Earned Value Management System(EVMS) which analyses the precess through performance measurement. Even though the EVMS is a highly efficient tool in the managerial aspect, it cannot easily determine the Planned Value(PV), Actual Cost(AC), or Earned Value(EV) due to the indistinct criteria and extensive data. The accurate calculation of AC in particular, is the basic of project management, but most companies record direct personnel expenses or direct expenses only. Since they calculate indirect expenses based on the estimated ratio, it limits the systematic project management that reflects changes in profit and loss of a company. This study introduces a EVMS for project management and its actual case based on EVMS and ERP system which some additional modules are installed for performance measurement. It is expected that this new method enables a company to save time and effort, and also to improve transparency by specifying expense items in detail and to switch quarterly settlement to monthly by reducing the time of calculation.

A Proposal of Unit Hydrograph Using Statistical Analysis in Oedo Stream, Jeju (통계적 기법을 적용한 외도천의 단위유량도 제안)

  • Lee, Jun-Ho;Yang, Sung-Kee;Jung, Woo-Yul
    • Journal of Environmental Science International
    • /
    • v.24 no.4
    • /
    • pp.393-401
    • /
    • 2015
  • Rainfall-runoff model of Jeju Oedo Stream was used to compute the optimal unit hydrograph by HEC-HMS model that reflecting on watershed characteristics. Each rainfall event was comparatively analyzed with the actual flow measurement using Clark, Snyder and SCS synthetic methods for derived unit hydrograph. Subsequently, the null hypothesis was established as p-value for peak flow and peak time of each unit hydrograph by one-way ANOVA(Analysis of variance) was larger than significance level of 0.05. There was no significant difference in peak flow and peak time between different methods of unit hydrograph. As a result of comparing error rate with actual flow measurement data, Clark synthetic unit graph best reflected in Oedo Stream as compared to other methods, and error rate of Clark unit hydrograph was 0.02~1.93% and error rate at peak time was 0~2.74%.

The effect of mandibular position on measurement in spiral tomography (나선형 단층방사선사진촬영에서 하악골 위치가 측정치에 미치는 영향)

  • Jung Yun-Hoa
    • Imaging Science in Dentistry
    • /
    • v.35 no.2
    • /
    • pp.83-86
    • /
    • 2005
  • Purpose : To evaluate the effect of deviation of mandibular positioning, by changing the mandibular plane inclination, on the measured height and width of mandible in spiral conventional tomography. Materials and Methods : By means of the Scanora multifunctional unit, cross-sectional tomograms were taken from two human dried mandibles at the mandibular angulations: -15 degree, -10 degree, -5 degree, and 0 degree. Twenty-eight sites in two dried mandibles were imaged. One examiner measured the bone heights and widths at selected sites on the images and the actual bone heights were recorded. Results : The bone heights at the four mandibular inclinations overestimated real bone heights and the mean difference between actual heights and image heights on 0 degrees was the smallest (P<0.01). The bone widths on -15 degrees were narrowest and there were significant differences between bone widths measured at the four mandibular inclinations (P<0.001). We found statistically significant differences between both bone heights and widths as measured according to the mandibular plane angle for the posterior region (P<0.01). Conclusion : The use of different mandibular positioning may result in discrepancies in heights and widths when measured from the cross-sectional tomographic images. It is suggested that the mandibular positioning may play a significant role in the measurement of mandibular heights and widths.

  • PDF

Passive Ranging Based on Planar Homography in a Monocular Vision System

  • Wu, Xin-mei;Guan, Fang-li;Xu, Ai-jun
    • Journal of Information Processing Systems
    • /
    • v.16 no.1
    • /
    • pp.155-170
    • /
    • 2020
  • Passive ranging is a critical part of machine vision measurement. Most of passive ranging methods based on machine vision use binocular technology which need strict hardware conditions and lack of universality. To measure the distance of an object placed on horizontal plane, we present a passive ranging method based on monocular vision system by smartphone. Experimental results show that given the same abscissas, the ordinatesis of the image points linearly related to their actual imaging angles. According to this principle, we first establish a depth extraction model by assuming a linear function and substituting the actual imaging angles and ordinates of the special conjugate points into the linear function. The vertical distance of the target object to the optical axis is then calculated according to imaging principle of camera, and the passive ranging can be derived by depth and vertical distance to the optical axis of target object. Experimental results show that ranging by this method has a higher accuracy compare with others based on binocular vision system. The mean relative error of the depth measurement is 0.937% when the distance is within 3 m. When it is 3-10 m, the mean relative error is 1.71%. Compared with other methods based on monocular vision system, the method does not need to calibrate before ranging and avoids the error caused by data fitting.

Modeling Alignment Experiment Errors for Improved Computer-Aided Alignment

  • Kim, Yunjong;Yang, Ho-Soon;Song, Jae-Bong;Kim, Sug-Whan;Lee, Yun-Woo
    • Journal of the Optical Society of Korea
    • /
    • v.17 no.6
    • /
    • pp.525-532
    • /
    • 2013
  • Contrary to the academic interests of other existing studies elsewhere, this study deals with how the alignment algorithms such as sensitivity or Differential Wavefront Sampling (DWS) can be better used under effects from field, compensator positioning and environmental errors unavoidable from the shop-floor alignment work. First, the influences of aforementioned errors to the alignment state estimation was investigated with the algorithms. The environmental error was then found to be the dominant factor influencing the alignment state prediction accuracy. Having understood such relationship between the distorted system wavefront caused by the error sources and the alignment state prediction, we used it for simulated and experimental alignment runs for Infrared Optical System (IROS). The difference between trial alignment runs and experiment was quite close, independent of alignment methods; 6 nm rms for sensitivity method and 13 nm rms for DWS. This demonstrates the practical usefulness and importance of the prior error analysis using the alignment algorithms before the actual alignment runs begin. The error analysis methodology, its application to the actual alignment of IROS and their results are described together with their implications.

Analysis of the Causes of Errors in Sound Wave Phase Meter (음파위상측정기의 오차 원인에 대한 분석)

  • Kim, So-Hee;Lee, Ki-Won
    • Journal of Sensor Science and Technology
    • /
    • v.28 no.5
    • /
    • pp.323-328
    • /
    • 2019
  • Recently, a sound wave phase meter (SWPM) that can directly measure the pressure waveform of sound waves in free space has been reported, and the development of educational experimental equipment using this meter is in progress. One of the main advantages of using this meter is that wavelengths can be obtained directly from the crests and troughs of the measured pressure waveforms in space without expensive equipment. However, there are times when the measurement wavelength does not exactly match the actual wavelength value, and the pressure waveform differs from the actual shape. This study was conducted to identify and analyze the causes of such errors occurring in SWPM. As a result, it was found that wavelength errors occur when the propagation direction of sound waves and the measurement direction of SWPM do not coincide. It has also been found that an error in the pressure waveform is generated when the induction and sound wave signal outputs from the SWPM interfere with each other to produce a composite signal. We have shown that we can develop educational experimental equipment by suggesting ways to reduce such errors.

Study of Stray-light Analysis and Suppression Methods for the Spectroscopic System of a Solar-radiation Observer Instrument

  • Zheng, Ru;Liu, Bo;Wang, Lingyun;Gao, Yue;Li, Guangxi;Li, Changyu
    • Current Optics and Photonics
    • /
    • v.5 no.3
    • /
    • pp.220-228
    • /
    • 2021
  • To improve the measurement accuracy of a solar-radiation observer instrument, aiming at the problem of multiorder-stray-light interference caused by the diffraction of the flat-field concave grating in the spectroscopic system, straylight suppression methods for different forms of optical traps are studied. According to the grating surface-scattering distribution-function model, the bidirectional scattering distribution function (BSDF) of a dust-polluted surface and the flat-field concave grating's transition area of the spectroscopic system is calculated, and a Lyot stop with blade baffle is designed to suppress this kind of stray light. For diffraction multiorder stray light, based on the theory of light-energy transmission, a design for precise positioning of the trench optical trap is proposed. The superiority of the method is verified through simulation and actual measurement. The simulation results show that in a spectroscopic system approximately 160 mm × 140 mm × 80 mm in size, the energy of the stray light is reduced by one order of magnitude by means of the trench optical trap and Lyot stop, and the number of beams is reduced from 5664 to 1040. The actual measurements show that the stray-light-suppression efficiency is about 69.4%, which is effective reduction of the amount of stray light.