• Title/Summary/Keyword: Actual Condition of Operation

Search Result 279, Processing Time 0.031 seconds

Development of prediction models of chlorine bulk decay coefficient by rechlorination in water distribution network (상수도 공급과정 중 재염소 투입에 따른 잔류염소농도 수체감소계수 예측모델 개발)

  • Jeong, Bobae;Kim, Kibum;Seo, Jeewon;Koo, Jayong
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.33 no.1
    • /
    • pp.17-29
    • /
    • 2019
  • This study developed prediction models of chlorine bulk decay coefficient by each condition of water quality, measuring chlorine bulk decay coefficients of the water and water quality by water purification processes. The second-reaction order of chlorine were selected as the optimal reaction order of research area because the decay of chlorine was best represented. Chlorine bulk decay coefficients of the water in conventional processes, advanced processes before rechlorination was respectively $5.9072(mg/L)^{-1}d^{-1}$ and $3.3974(mg/L)^{-1}d^{-1}$, and $1.2522(mg/L)^{-1}d^{-1}$ and $1.1998(mg/L)^{-1}d^{-1}$ after rechlorination. As a result, the reduction of organic material concentration during the retention time has greatly changed the chlorine bulk decay coefficient. All the coefficients of determination were higher than 0.8 in the developed models of the chlorine bulk decay coefficient, considering the drawn chlorine bulk decay coefficient and several parameters of water quality and statistically significant. Thus, it was judged that models that could express the actual values, properly were developed. In the meantime, the chlorine bulk decay coefficient was in proportion to the initial residual chlorine concentration and the concentration of rechlorination; however, it may greatly vary depending on rechlorination. Thus, it is judged that it is necessary to set a plan for the management of residual chlorine concentration after experimentally assessing this change, utilizing the methodology proposed in this study in the actual fields. The prediction models in this study would simulate the reduction of residual chlorine concentration according to the conditions of the operation of water purification plants and the introduction of rechlorination facilities, more reasonably considering water purification process and the time of chlorination. In addition, utilizing the prediction models, the reduction of residual chlorine concentration in the supply areas can be predicted, and it is judged that this can be utilized in setting plans for the management of residual chlorine concentration.

A study on Actual Condition and Interfererence of Electromagnetic Fields inside of The Hospital (I) (의료기관내 전자파환경 실태와 그 영향 (I))

  • Lee, Jun-Ha;Shin, Hyun-Jin;Yoo, Heum
    • Progress in Medical Physics
    • /
    • v.8 no.1
    • /
    • pp.53-67
    • /
    • 1997
  • General hospitals have being under the influence of various and specific environment of electromagnetic field. The factors are development of medical electric equipment and device with enlarged functional demands, in high power and multi-frequency. It has all of both faces, EMI(electromagnetic interference) and EMS(electromagnetic susceptibility). In additional, expansion of personal communication system(cellular phone) has many unreliable factor of using time and area, making noise of electromagnetic fields. We studied actual conditions of EMI in the medical site, where is numerous medical equipment, especially central operation room and ICU(intensive care unit), AKR(artificial kidney room : hemo-dialysis unit), etc. The influence, most of medical equipments made electromagnetic nosie has various factors in its band of frequency, harmonics and strength. In the experimental use of electro-surgical unit and cellular phone, noticeable and considerable noise of eletromagnetic fields were measured. All of that can make trouble and errors on the steadiness of bioelectrical devices. In conclusion, It is necessary to reconsiderations of reallocating EMI source vs. EMS factor, and set to definite forbiding area of using cellular phone. For maintenance of steady normal conditions, in spite of existing any other legal standards of safty level, it need considering all of alternative electromagnetic situations on a case-by-case basis.

  • PDF

Study on the Identification of Ship Maneuverability Required for Navigational Officers based on AHP Analysis (AHP 분석 기반 항해사 필요 선박조종성능 식별 연구)

  • Kang, Suk-Young;Ahn, Young-Joong;Yu, Yong-Ung;Lee, Yun-Sok
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.28 no.5
    • /
    • pp.800-808
    • /
    • 2022
  • The International Maritime Organization adopted the interim standards for ship maneuverability in November 1993 for preventing collision of ships at sea and for protecting the marine environment, and based on the accumulated data, in December 2002, the established standards for ship maneuverability were adopted. However, the standards adopted are those at full load, even keel, and at least 90 % of the ship speed at 85 % of the ship's maximum power. Moreover, these standards have limitations in providing information on maneuverability under actual navigational conditions. Therefore, in this study, frequency analysis AHP analysis techniques were studied by consulting navigational officers, captains, and experts, who have significant knowledge on ship maneuverability, utilization of the current standards, and the information necessary for the operation of the actual ship. The results of this study confirmed that the necessary information on maneuverability for the navigational officer operating the vessel is information about the turning circle at a small angle of 5°-10° and z-test information at maneuvering speed, not sea speed. Additionally, in relation to speed control, additional information on deceleration inertia and acceleration inertia is needed than the information on the stopping ability at sea speed and full loaded condition. The derived results are considered to be useful as basic data for preparing guidelines for ship maneuverability necessary for navigational of icers who operate ships.

Study on the Improvement of Gill Nets and Trap Nets Fishing for the Resource Management at the Coastal Area of Yellow Sea -On the Present States of Gill Nets and Trap Nets Fishing and Body Length Distribution of Main Catch at the Coastal Area of Yellow Sea- (서해구 자원관리형 지망ㆍ통발 어구어법 기술개발에 관한 연구 - 서해구 자망ㆍ통발어업의 현황과 주어획물의 체장분포 -)

  • 장호영;조봉곤;박종수;두성균
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.39 no.1
    • /
    • pp.50-55
    • /
    • 2003
  • In order to study on the improvement of gill nets and trap nets fishing for the management of fisheries resource in the coastal area of Yellow Sea, we have investigated the general present condition of those fishing, and the actual fishing operation of gill nets for croaker and trap nets for rock shell which is called the the other trap nets, and then measured the body length of croaker and blue shell caught by their fishing vessels. The results are as follows ; 1. The total number of permission for coastal fishing are 12,944 cases, but the number of operation for coastal fishing are 7,558 cases in the coastal area of Yellow Sea. Among the total number of permission, the gill nets fishing are 5,154 cases with 39.8% but even so the number of operation are 3,724 cases, the trap nets fishing are 1,025 cases with 7.6% but even so the number of operation are 662 cases. On the fishing ratio, the gill nets and trap nets fishing are comparatively higher than the other fishing with 72.3% and 64.6%, respectively. 2. The main fishing period of gill nets for croaker is from the middle of July to early of September, and the main fishing grounds are sandymud bottom of 15-50m in depth around the islands of southern parts of western coastal area, and the fishing operation carry out 1∼2 times per day in flood tide and nets hauling conduct in 1∼2 hours after drifting with current. 3. The distribution range of body length of 139 croakers, which are caught in the gill nets, are 43.0∼120.0㎝ and the mode is 85.0㎝. 4. The main fishing period of trap nets for rock shell which is called the other trap nets is all the year round except the catching period of blue crab from early of September to the middle of October, and the main fishing ground are the sandymud bottom of 10∼20m in depth, and nets hauling conduct in next day after nets casting. 5. The distribution range of maximum carapace of 5,372 rock shells are 4.5∼8.5㎝ and the mode is 7.5㎝.

Risk Factor Analysis for $SaO_2$ Instability after Systemic-pulmonary Shunt (전신-폐 단락술 후 산소포화도의 불안정성의 위험인자 분석)

  • Jung Sung-Ho;Yun Sok-Won;Park Jung-Jun;Seo Dong-Man;Kim Young-Hwue;Ko Jae-Kon;Park In-Sook;Yun Tae-Jin
    • Journal of Chest Surgery
    • /
    • v.38 no.4 s.249
    • /
    • pp.277-283
    • /
    • 2005
  • Arterial oxygen saturation $(SaO_2)$ instability frequently takes place after systemic-pulmonary shunt without shunt occlusion. We analyzed actual incidence and risk factors for $SaO_2$ instability after shunt operations, and possible mechanisms were speculated on. Material and Method: Ninety three patients, who underwent modified Blalock-Taussig shunt from January 1996 to December 2000, were enrolled in this study. Adequacy of shunt was verified in all patients, either by ensuing one ventricle or biventricular repair later on or by appropriate pulmonary artery growth on postoperative angiogram. Age, body weight, hemoglobin level at operation were 3 day to 36 years (median: 1.8 months), 2.5kg to 51kg (median: 4.1kg) and $10.7\~24.3$ gm/dL (median: 15.2 gm/dL) respectively. Preoperative diagnoses were functional single ventricle with pulmonary stenosis or atresia in 39, tetralogy of Fallot in 38 and pulmonary atresia with intact ventricular septum in 16. Pulmonary blood flow (PBF) was maintained pre-operatively by patent ductus or previous shunt in 64 and by forward flow through stenotic right ventricular outflow tract (RVOT) in 29. $SaO_2$ instability was defined as $SaO_2$ less than $50\%$ for more than 1 hour with neither anatomic obstruction of shunt nor respiratory problem. Result: 10 patients $(10.7\%)$ showed $SaO_2$ instability after shunt operation. After shunt occlusion was ruled out by echocardiogram, they received measures to lower pulmonary vascular resistance (PVR), which worked within a few hours in all patients. Risk factors for $SaO_2$ instability included older age at operation (p=0.039), lower preoperative $SaO_2$ (p=0.0001) and emergency operation (p=0.001). PBF through stenotic RVOT showed marginal statistical significance (p=0.065). Conclusion: $SaO_2$ instability occurs frequently after shunt operation, especially in patients with severe hypoxia pre-operatively or unstable clinical condition necessitating emergency operation. Temporary elevation of pulmonary vascular resistance is a possible mechanism in this specific clinical setting.

A Systematic Approach to Port related Problems An Analysis on the Actual Condition of physical Distribution System of Pusan port (항만관련문제의 시스템적 고찰 부산항 물류시스템의 실태분석)

  • Lee Cheol-Yeong;Moon Seong-Hyeok
    • Journal of Korean Port Research
    • /
    • v.2 no.1
    • /
    • pp.7-28
    • /
    • 1988
  • From the viewpoint of physical distribution, the port transport process can be regarded as a system which consists of various subsystems such as navigational aids, quay handling, transfer, storage, information If management, and co-ordination with inland transport. The handling productivity of this system is determined by the production level of the least productive subsystem. So, a productivity analysis on the flow of cargoes through each subsystem should be made in order to achieve efficient port operation. The purpose of this paper is to analyze the productivity of each subsystem in Pusan port, and to bring forward problems and finally to draw up plans for their betterment. Analyzed results on the productivity of each subsystem are as follows, i) It is known that the number of tugs with low HP should be increased by a few, the number of tugs with medium HP is appropriate, and the number of tugs with high HP is in excess of that necessary. ii ) In the case of container cargoes, it is found that the transfer and storage systems in BCTOC have the lowest handling capability, with a rate of $115\%$, leading to bottle-necks in the port transport system, while the handling rate of the storage and quay handling systems in general piers is in excess of the inherent capability. iii) In the case of the principal seaborne cargoes passing through general piers, there is found to be a remarkable bottle-neck in the storage system. In the light of these findings, both the extension of storage capability and the extension of handling productivity are urgently required to meet the needs of port users. Therefore, iv) As a short-term plan, it is proposed that many measures such as the reduction of free time, the efficient application of ODCY, etc must be brought in and v) In the long-trun, even though the handling capability will accommodate an additional 960,000 TEU in 1991, the scheduled completion date of the third development plan of Pusan port, insufficiency of handling facilities in the container terminal is still expected and concrete countermeasures will ultimately have to be taken for the port's harmonious operation. In particular, the problem of co-ordination with inland transport and urban traffic should be seriously examined together in the establishment of the Pusan port development. As a method of solving this, vi) It is suggested that Pusan port (North port) should be converted into an exclusive container ternimal and overall distribution systems to the other ports for treating general cargoes must be established. vii) And finally, it is also proposed that the arrival time (cut-off time) of influx cargoes for exports such as general merchandise and steel product should be limited, with a view to securing cargoes suitable for the operational capability of BCTOC.

  • PDF

A Study on the Nursing Needs and Service Satisfactory of Users in the Post-Partum Care Center (산후조리원을 이용한 산모의 간호요구 및 만족도)

  • Jung, Hyun
    • Women's Health Nursing
    • /
    • v.5 no.2
    • /
    • pp.222-229
    • /
    • 1999
  • These days, as the society has been in the trends of highly industrialized and the family has been downsized, there is remarkably increasing number of women who follow occupation. These changes have made it more difficult for the family to help post-partum mother, which had been performed in side of house. By the help of social believe that during at least 1 month after childbirth professional nursing program is indispensable for both maternity protection and physical-mental recuperation, now many post-partum care centers for post-partum mother have been in operation. Although these post-partum care center have in use for a long time, no study was performed before this study on the same subject. Data were analyzed using by SAS. The results of study are as follow : 1. The general features of the user of the post-partum care center. The predominant band of user's age is extended from 26 to 30. The users are mainly housewives and they are in higher level of incomes and educations. As for the feature of delivery methods, they performed the normal spontaneous vaginal delivery method by 58.0% and the Caesarean operation method by 42.0%. As for the sexuality for babies, 59.3% of infants are male, and 40.7% are female. The highest delivery order of users is first and admission after 1-3days delivery is highest. 2. The results for the investigation into the actual condition of the post-partum care center are as follow : About the main reason for entrance of the post-partum care center was found to be the needs for the better nursing programs for recuperation after childbirth. This demands are also supported by their husbands. The average length of stay in the post-partum care center is 17.6 days and the besides promised expense ; powdered milk, milk-suckers, disposable dippers, skin cares, body shape cares, entrophics, injections. The post-partum have private rooms for mother and infants. Over the half of average expense is 229 million won. They are paying accessory fees the post-partum care center have similar step organization : the nurses, the skin carers, the cleaners. Mostly both ways of feeding powdered milk and breast feeding are in use, and mother's milk is preserved in the night time to be given to infant by nurse in charge. 3. The results of the investigation on users' nursing demand to the post-partum care center and satisfaction are as follow : The ranking order of nursing demand of mothers who used the is that ; infant care demands, environmental demands, emotional and mental care demands, education and training demands. As much as 70% of the respondents have dissatisfaction in nursing program, The ranking order of service satisfaction of mothers who used appears to be higher following order ; satisfaction in infant care demand, satisfaction in physical nursing demand, satisfaction in emotional and mental nursing demand, satisfaction in education and training demand, satisfaction in environment nursing demand. The results of pearson correlation. between nursing demand and service satisfaction of mothers who used are found to be relative noticeable in the level of 0.05. only infant care. The 61.7% of the women who used the post-partum care center. are responding that they will reuse the same post-partum care center again.

  • PDF

Design of Fetal Health Classification Model for Hospital Operation Management (효율적인 병원보건관리를 위한 태아건강분류 모델)

  • Chun, Je-Ran
    • Journal of Digital Convergence
    • /
    • v.19 no.5
    • /
    • pp.263-268
    • /
    • 2021
  • The purpose of this study was to propose a model which is suitable for the actual delivery system by designing a fetal delivery hospital operation management and fetal health classification model. The number of deaths during childbirth is similar to the number of maternal mortality rate of 295,000 as of 2017. Among those numbers, 94% of deaths are preventable in most cases. Therefore, in this paper, we proposed a model that predicts the health condition of the fetus using data like heart rate of fetuses, fetal movements, uterine contractions, etc. that are extracted from the Cardiotocograms(CTG) test using a random forest. If the redundancy of the data is unbalanced, This proposed model guarantees a stable management of the fetal delivery health management system. To secure the accuracy of the fetal delivery health management system, we remove the outlier which embedded in the system, by setting thresholds for the upper and lower standard deviations. In addition, as the proportion of the sequence class uses the health status of fetus, a small number of classes were replicated by data-resampling to balance the classes. We had the 4~5% improvement and as the result we reached the accuracy of 97.75%. It is expected that the developed model will contribute to prevent death and effective fetal health management, also disease prevention by predicting and managing the fetus'deaths and diseases accurately in advance.

Optimization Process Models of CHP and Renewable Energy Hybrid Systems in CES (구역전기 사업시 CHP와 신재생에너지 하이브리드 시스템의 최적공정 모델)

  • Lee, Seung Jun;Kim, Lae Hyun
    • Journal of Energy Engineering
    • /
    • v.26 no.2
    • /
    • pp.99-120
    • /
    • 2017
  • In SS branch of Korea District Heating Corporation, Combined Heat & Power power plant with 99MW capacity and 98Gcal / h capacity is operated as a district electricity business. In this region, it is difficult to operate the generator due to the problem of surplus heat treatment between June and September due to the economic recession and the decrease in demand, so it is urgent to develop an economical energy new business model. In this study, we will develop an optimized operation model by introducing a renewable energy hybrid system based on actual operation data of this site. In particular, among renewable energy sources, fuel cell (Fuel Cell) power generation which can generate heat and electricity at the same time with limited location constraints, photovoltaic power generation which is representative renewable energy, ESS (Energy Storage System). HOMER (Hybrid Optimization of Multiple Energy Resources) program was used to select the optimal model. As a result of the economic analysis, 99MW CHP combined cycle power generation is the most economical in terms of net present cost (NPC), but 99MW CHP in terms of carbon emission trading and renewable energy certificate And 5MW fuel cells, and 521kW of solar power to supply electricity and heat than the supply of electricity and heat by 99MW CHP cogeneration power, it was shown that it is economically up to 247.5 billion won. we confirmed the results of the improvement of the zone electricity business condition by introducing the fuel cell and the renewable energy hybrid system as the optimization process model.

A Study on the integrated management system for tourism complexes based on IoT technology (IoT 기술을 기반으로 한 관광단지 통합관리시스템에 관한 연구)

  • An, Tai-Gi
    • Journal of Industrial Convergence
    • /
    • v.17 no.4
    • /
    • pp.1-8
    • /
    • 2019
  • The purpose of this study is to analyze the actual condition of tourism complex and to apply IoT-based integrated management system to tourism complex to improve the utilization and management of tourism complex. Tourists need various information to take the lead in tourism activities, and all of these necessary information is collected through various routes such as information of the Internet, travel agencies, newspapers, and surrounding experiences. Recently, information provision through the Internet has taken a large part due to the development of information technology, and systems that combine IoT technology are being constructed. This is because the popularization of IoT technology improves the diversity, accessibility and convenience of information and makes it convenient to use. The purpose of this study is to suggest the importance of tourism information service using IoT-based system and future research directions. The previous studies on IoT-based system construction were also reviewed considering the efficiency of IoT technology. In order to solve the problems of tourism complex, this study improved the IoT-based tourism complex operation system and conducted operation management. IoT-based management system is expected to be improved as a tourism complex platform and is expected to be improved by overall management cases and experiences.


(34141) Korea Institute of Science and Technology Information, 245, Daehak-ro, Yuseong-gu, Daejeon
Copyright (C) KISTI. All Rights Reserved.