• 제목/요약/키워드: Actively Controlled Capillary

검색결과 4건 처리시간 0.022초

Motion Error Compensation Method for Hydrostatic Tables Using Actively Controlled Capillaries

  • Park Chun Hong;Oh Yoon Jin;Hwang Joo Ho;Lee Deug Woo
    • Journal of Mechanical Science and Technology
    • /
    • 제20권1호
    • /
    • pp.51-58
    • /
    • 2006
  • To compensate for the motion errors in hydrostatic tables, a method to actively control the clearance of a bearing corresponding to the amount of error using actively controlled capillaries is introduced in this paper. The design method for an actively controlled capillary that considers the output rate of a piezo actuator and the amount of error that must be corrected is described. The basic characteristics of such a system were tested, such as the maximum controllable range of the error, micro-step response, and available dynamic bandwidth when the capillary was installed in a hydrostatic table. The tests demonstrated that the maximum controllable range was $2.4\;{\mu}m$, the resolution was 27 nm, and the frequency bandwidth was 5.5 Hz. Simultaneous compensation of the linear and angular motion errors using two actively controlled capillaries was also performed for a hydrostatic table driven by a ballscrew and a DC servomotor. An iterative compensation method was applied to improve the compensation characteristics. Experimental results showed that the linear and angular motion errors were improved to $0.12{\mu}m$ and 0.20 arcsec, which were about $1/15^{th}$ and $1/6^{th}$ of the initial motion errors, respectively. These results confirmed that the proposed compensation method improves the motion accuracy of hydrostatic tables very effectively.

유정압안내면 운동오차보정용 능동제어모세관의 기본특성 (Basic Characteristics of an Active Controlled Capillary for Compensating the Error Motion of Hydrostatic Guideways)

  • Song, Y.C.;Park, C.H.;Kim, S.T.
    • 한국정밀공학회지
    • /
    • 제14권8호
    • /
    • pp.130-136
    • /
    • 1997
  • For compensating the error motion of hydrostatic guideways, we introduce a way that the clearance of table is actively controlled corresponding to the amount of error with the variable capillary. The structure and the theoretical design method of active controlled capillary using piezo actuator, named ACC, are proposed in this paper. Basic characteristics such as the maximum controllable range, micro step response and available dynamic bandwidth are tested for confirmation of structural suitability of ACC, and these characteristics are also tested on the table mounted with ACC for verifying the availability. The experimental result showed that by the use of ACC, the error motion within 2.7 .mu. m of a hydrostatic guideway can be compensated with the resolution of 2.7nm, 1/100 contollable range, and the frequency bandwidth of 5.5 Hz. From these results, it is confirmed that the ACC is very effective to improve the motion accuracy of high or ultra precision hydrostatic guideways.

  • PDF

능동제어모세관을 이용한 유정압테이블의 운동정도 향상 (Improvement of Motion Accuracy Using Active Controlled Capillary in Hydrostatic Table)

  • Park, C.H.;Song, Y.C.;Lee, H.S.
    • 한국정밀공학회지
    • /
    • 제14권12호
    • /
    • pp.114-120
    • /
    • 1997
  • For compensating the error motion of hydrostatic tables, we have introduced a way that the clearance of table is controlled corresponding to the amount of eror with the actively controlled variable capillary, named as ACC. In previous paper, through the basic test, it was confirmed that by the use of ACC, the error motion within 2.7$\mu$ m of a hydrostatic table could be compensated with the resolution of 27nm, 1/100 contollable range, and with the frequency bandwidth of 5.5Hz, structurally. In this paper, we performed practical compensation of the linear and angular motion error of hydrostatic table using ACC. For improving the compensated motion accuracy, iterative control method is put into the control system. The experimental results show that by the simultaneous compensation of error, the linear and angular motion error are improved upto 0.25$\mu$ m and 0.4arcsec, which are about 1/10 and 1/3 of the non-compensated motion errors respectively.

  • PDF

능동제어모세관을 이용한 유정압테이블의 운동정도 향상

  • 송영찬;박천홍;김수태
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 1997년도 춘계학술대회 논문집
    • /
    • pp.250-256
    • /
    • 1997
  • For compensating the error motion of hydrostatic tables, we have introduced a way that the clarance of table is actively controlled corresponding to the amount of error with the nariable capillary,anmed as ACC. In previous paper,through the basic test, it was confirmed that by the use of ACC,the error motion within 2.7 .mu.m of a hydrostatic table could be compensated with the resolution of 27nm, 1/100 contollable range, and with the freqency bandwidth of 5.5Hz structurally. In this paper,we performed practital compensation of the linear and angular motion error of hydrostatic table using ACC. For improving the compensated motion accuracy,iterative control method is put into the control system. The experimental results show that by the simultaneous compensation of error,the linear and angular motion error are improved upto 0.25 .mu.m and 0.4arcsec,which are about 1/10 and 1/3 of the non-compensated motion errors respectively.