순환형 신경망을 이용한 적응형 능동소음제어시스템의 성능 향상에 대한 연구 (Research on Performance Improvement of the Adaptive Active Noise Control System Using the Recurrent Neural Network)

  • 한성익;이태오;여대연;이권순
    • 한국정보통신학회논문지
    • /
    • 제14권8호
    • /
    • pp.1759-1766
    • /
    • 2010
  • 순환형 신경망을 이용한 적응형 능동소음 제어시스템의 소음저감 성능을 개선한다. 능동소음제어에 가장 많이 사용되고 있는 FXLMS는 단순하고 계산 부담이 적지만 FIR 선형필터에 기반을 둔 필터링 방법이어서 주 경로 또는 2차 경로의 비선형특성에 취약한 단점이 있다. 본 연구에서는 이러한 비선형 특성과 불확실성에 대해 강인한 특성을 갖는 순환형 신경망 필터링 기법을 개발하여 능동소음 제어시스템의 소음 저감 성능을 개선함을 시뮬레이션을 통해 보인다.

Active Voltage-balancing Control Methods for the Floating Capacitors and DC-link Capacitors of Five-level Active Neutral-Point-Clamped Converter

  • Li, Junjie;Jiang, Jianguo
    • Journal of Power Electronics
    • /
    • 제17권3호
    • /
    • pp.653-663
    • /
    • 2017
  • Multilevel active neutral-point-clamped (ANPC) converter combines the advantages of three-level ANPC converter and multilevel flying capacitor (FC) converter. However, multilevel ANPC converter often suffers from capacitor voltage balancing problems. In order to solve the capacitor voltage balancing problems for five-level ANPC converter, phase-shifted pulse width modulation (PS-PWM) is used, which generally provides natural voltage balancing ability. However, the natural voltage balancing ability depends on the load conditions and converter parameters. In order to eliminate voltage deviations under steady-state and dynamic conditions, the active voltage-balancing control (AVBC) methods of floating capacitors and dc-link capacitors based on PS-PWM are proposed. First, the neutral-point current is regulated to balance the neutral-point voltage by injecting zero-sequence voltage. After that, the duty cycles of the redundant switch combinations are adjusted to balance the floating-capacitor voltages by introducing moderating variables for each of the phases. Finally, the effectiveness of the proposed AVBC methods is verified by experimental results.

Novel Control Method for a Hybrid Active Power Filter with Injection Circuit Using a Hybrid Fuzzy Controller

  • Chau, MinhThuyen;Luo, An;Shuai, Zhikang;Ma, Fujun;Xie, Ning;Chau, VanBao
    • Journal of Power Electronics
    • /
    • 제12권5호
    • /
    • pp.800-812
    • /
    • 2012
  • This paper analyses the mathematical model and control strategies of a Hybrid Active Power Filter with Injection Circuit (IHAPF). The control strategy based on the load harmonic current detection is selected. A novel control method for a IHAPF, which is based on the analyzed control mathematical model, is proposed. It consists of two closed-control loops. The upper closed-control loop consists of a single fuzzy logic controller and the IHAPF model, while the lower closed-control loop is composed of an Adaptive Network based Fuzzy Inference System (ANFIS) controller, a Neural Generalized Predictive (NGP) regulator and the IHAPF model. The purpose of the lower closed-control loop is to improve the performance of the upper closed-control loop. When compared to other control methods, the simulation and experimental results show that the proposed control method has the advantages of a shorter response time, good online control and very effective harmonics reduction.

A hybrid seismic response control to improve performance of a two-span bridge

  • Heo, Gwanghee;Kim, Chunggil;Jeon, Seunggon;Lee, Chinok;Jeon, Joonryong
    • Structural Engineering and Mechanics
    • /
    • 제61권5호
    • /
    • pp.675-684
    • /
    • 2017
  • In this paper, a hybrid seismic response control (HSRC) system was developed to control bridge behavior caused by the seismic load. It was aimed at optimum vibration control, composed of a rubber bearing of passive type and MR-damper of semi-active type. Its mathematical modeling was driven and applied to a bridge model so as to prove its validity. The bridge model was built for the experiment, a two-span bridge of 8.3 meters in length with the HSRC system put up on it. Then, inflicting the EI Centro seismic load on it, shaking table tests were carried out to confirm the system's validity. The experiments were conducted under the basic structure state (without an MR-damper applied) first, and then under the state with an MR-damper applied. It was also done under the basic structure state with a reinforced rubber bearing applied, then the passive on/off state of the HSRC system, and finally the semi-active state where the control algorithm was applied to the system. From the experiments, it was observed that pounding rather increased when the MR-damper alone was applied, and also that the application of the HSRC system effectively prevented it from occurring. That is, the experiments showed that the system successfully mitigated structural behavior by 70% against the basic structure state, and, further, when control algorithm is applied for the operation of the MR-damper, relative displacement was found to be effectively mitigated by 80%. As a result, the HSRC system was proven to be effective in mitigating responses of the two-span bridge under seismic load.

PI and Fuzzy Logic Controller Based 3-Phase 4-Wire Shunt Active Filters for the Mitigation of Current Harmonics with the Id-Iq Control Strategy

  • Mikkili, Suresh;Panda, Anup Kumar
    • Journal of Power Electronics
    • /
    • 제11권6호
    • /
    • pp.914-921
    • /
    • 2011
  • Commencing with incandescent light bulbs, every load today creates harmonics. Unfortunately, these loads vary with respect to their amount of harmonic content and their response to problems caused by harmonics. The prevalent difficulties with harmonics are voltage and current waveform distortions. In addition, Electronic equipment like computers, battery chargers, electronic ballasts, variable frequency drives, and switching mode power supplies generate perilous amounts of harmonics. Issues related to harmonics are of a greater concern to engineers and building designers because they do more than just distort voltage waveforms, they can overheat the building wiring, cause nuisance tripping, overheat transformer units, and cause random end-user equipment failures. Thus power quality is becoming more and more serious with each passing day. As a result, active power filters (APFs) have gained a lot of attention due to their excellent harmonic compensation. However, the performance of the active filters seems to have contradictions with different control techniques. The main objective of this paper is to analyze shunt active filters with fuzzy and pi controllers. To carry out this analysis, active and reactive current methods ($i_d-i_q$) are considered. Extensive simulations were carried out. The simulations were performed under balance, unbalanced and non sinusoidal conditions. The results validate the dynamic behavior of fuzzy logic controllers over PI controllers.

능동 필터 기능을 갖는 무정전전원장치의 정적 스위치 제어 (Static Switch Control of UPS with Active Filter Function)

  • 홍현문;전병석;김종근;이상훈;김재식;민완기
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 2005년도 춘계학술대회논문집
    • /
    • pp.406-408
    • /
    • 2005
  • In this literature, when the utility line is normal, the Off-Line UPS operates as an active power filter to compensate the reactive power from a load, and when the utility line is in outage, the On-Line UPS opuates as in single phase inverter to supply an active and reactive power to the load. An additional static switch in UPS was used to decrease an transient state during these mode changes. And the result shows that the transient state disappeared.

  • PDF

가변 전류형 능동 전력 필터 (The Controllable Current-Source Active Power Filter)

  • 김호진;조한덕;김홍성;최규하;김한성
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1992년도 하계학술대회 논문집 B
    • /
    • pp.1077-1080
    • /
    • 1992
  • In this paper suggested methods for current control in active filter are using the triangular carriers which were composed of independently generated threefold carriers and controllable current source which compensates the harmonics generated independently from the types of the load with instantaneous amplitude adjusting from the maximum magnitude of the compensating currents. And the 2-nd order high pass passive filter connected to the source finally supplies pure sinusoidal waves by suppressing the residual harmonics which cannot removed by the active filter. As the typical load which generates the harmonics, a rectifier was set and the system was also designed by simulations and implementations.

  • PDF

액티브 클램프 기법을 이용한 영전압 스위칭 직렬 공진형 컨버터에 관한 연구 (Study of ZVS-PWM Series Resonant Converter with Active-Clamp Technique)

  • 전희철;김용;정계천;김필수;이은영
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1999년도 하계학술대회 논문집 F
    • /
    • pp.2674-2677
    • /
    • 1999
  • Resonant converters have several salient features such as high efficiency and low noise. Therefore, ZVS-PWM controlled series resonant converter with active-clamp technique is presented. The combination of an active-clamp technique and resonant circuit makes it possible to control the output voltage of the resonant converter with PWM. This new resonant converter was implemented and has achieved a good controllability. In this paper, the normal load characteristics and abnormal voltage increase in the case of the light load are analyzed. As a result, it is clarified that the stray capacitance of the transformer is a cause of the abnormal voltage increase. Then, it is confirmed that the abnormal voltage increase is suppressed by decreasing the duty ratio. ZVS condition is analyzed. The maximum efficiency of 89% is obtained for the output of 10V and 5A.

  • PDF

The Harmonic Current Mitigation of DFIG under Unbalanced Grid Voltage and Non-linear Load Conditions

  • Thinh, Quach Ngoc;Kim, Eel-Hwan
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2011년도 전력전자학술대회
    • /
    • pp.83-84
    • /
    • 2011
  • This paper presents an analysis and a novel strategy for a doubly fed induction generator (DFIG) based wind energy conversion system under unbalanced grid voltage and non-linear load conditions. A proportional-resonant (PR) current controller is applied in both grid side converter (GSC) and rotor side converter (RSC). The RSC is controlled to mitigate the stator active power and the rotor current oscillations at double supply frequency under unbalanced grid voltage while the GSC is controlled to mitigate ripples in the dc-link voltage and compensate harmonic components of the network current. Simulation results using Psim simulation program are presented for a 2 MW DFIG to confirm the effectiveness of the proposed control strategy.

  • PDF

Design and implementation of AMD system for response control in tall buildings

  • Teng, J.;Xing, H.B.;Xiao, Y.Q.;Liu, C.Y.;Li, H.;Ou, J.P.
    • Smart Structures and Systems
    • /
    • 제13권2호
    • /
    • pp.235-255
    • /
    • 2014
  • This paper mainly introduces recently developed technologies pertaining to the design and implementation of Active Mass Damper (AMD) control system on a high-rise building subjected to wind load. Discussions include introduction of real structure and the control system, the establishment of analytical model, the design and optimization of a variety of controllers, the design of time-varying variable gain feedback control strategy for limiting auxiliary mass stroke, and the design and optimization of AMD control devices. The results presented in this paper demonstrate that the proposed AMD control systems can resolve the issues pertaining to insufficient floor stiffness of the building. The control system operates well and has a good sensitivity.