• 제목/요약/키워드: Active integrator

검색결과 51건 처리시간 0.022초

뇌방전에 의한 유도전압의 측정에 대한 기초적 연구 (A Basic Study on the Measurement Induced Voltages due to Lightning Discharges)

  • 이복희;조성철;엄주홍;이우철
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 2004년도 춘계학술대회 논문집
    • /
    • pp.559-564
    • /
    • 2004
  • This paper deals with the device for measuring the time-varying magnetic fields and induced voltages caused by lightning discharges. The two magnetic field measuring systems were designed and made. One consists of the loop-type magnetic field sensor with the active integrator operated by a differential amplifier. The other consists of the loop-type magnetic field sensor and Labview software. The loop-type magnetic field sensor detects the time derivative of the magnetic field being measured, and the signal detected is integrated by the Labview software. As a consequence, from the calibration experiments, the frequency bandwidth of the full measuring system ranges from 400 [Hz] to 1 (MHz) and the response sensitivity are 0.98 (mV/nT) and 22 (mV/nT) for the magnetic field sensor of 2 turns and 6 turns, respectively. Also, the results obtained by the two measuring devices well agreed with each other.

  • PDF

전동력설비의 운전에 의해 발생되는 자계의 측정과 해석 (Analysis and Measurement of the Magnetic Fields Cause by Operation of Electromotive Installations)

  • 이복희;길경석
    • 한국조명전기설비학회지:조명전기설비
    • /
    • 제9권2호
    • /
    • pp.58-67
    • /
    • 1995
  • 본 논문은 유도전동기의 운전조작시에 발생되는 자계변화특성에 대하여 기술하였다. 본 측정시스템은 자기적분형 자계센서, 증폭기, 능동형 적분기로 이루어졌으며, 교정실험에 대한 측정계의 주파수대역과 감도는 각각 20[Hz]~0.234[mV/$\mu$T]이다. 유도전동기의 기동과 정상운전중에 발생하는 자계성분을 측정하였으며, 고조파 성분을 고속 푸리에 변환기법으로 분석하였다. 유도전동기의 직입기동시에는 단일성 펄스자계가 강하게 발생하였으며, 이의 피크치는 정상상태의 값보다 5배이상 크게 나타났다. 이러한 긴 과도시간과 강한 자계의 세기는 전동기의 큰 인덕턴스와 동특성에 기인된다. 유도전동기의 정상운전시에는 유도전동기의 극수에 의존하는 기본파에 대한 분조파의 자계성분이 관측되었다. 또한, 자계의 분조파 성분은 전동기의 토크 변동으로 불균일한 회전토크로 인해 생기는 맥동전류와 전압플리커에 의해서 발생하는 것으로 생각된다. 인버터구동형 유도전동기에서는 직입기동에 비하여 많은 고조파 성분이 발생되고 있었으며, 특히 전동기의 구동주파수가 낮을수록 맥동토크에 의한 전류변화로 고조파 성분은 더욱 증가하였다.

  • PDF

Application of LQR for Phase-Locked Loop Control Systems

  • Khumma, Somyos;Benjanarasuth, Taworn;Isarakorn, Don;Ngamwiwit, Jongkol;Wanchana, Somsak;Komine, Noriyuki
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 2004년도 ICCAS
    • /
    • pp.520-523
    • /
    • 2004
  • A phase-locked loop control system designed by using the linear quadratic regulator approach is presented in this paper. The system thus designed is optimal system when system is in locked state and the parameter value of loop filter which is an active PI filter can be obtained easily. By considering the structure of loop filter of phase-locked loop is included in the process to be controlled, a type 1 servo system can be constructed when voltage control oscillator is considered as an integrator. The integral gain of the proposed system obtained by linear quadratic regulator approach can be used as an optimal value to design the parameter of loop filter. The implemented result in controlling the second-order lag pressure process by using the proposed scheme show that the system response is fast with no overshoot and no steady-state error. Furthermore, the experimental results are also shown in term of output disturbance effect rejection, tracking and process parameter changed.

  • PDF

GB 적을 고려한 능동려파회로구성에 관한 연구 (Synthesis of Active Filters Using Operational Amplitiers of Finite GB Product)

  • 이태원;조용현;류제근
    • 대한전자공학회논문지
    • /
    • 제17권4호
    • /
    • pp.45-52
    • /
    • 1980
  • 집적회로화된 연산증폭기의 GB종의 유한성으로 인한 위상오차가 능동여피기의 사용가능주파수를 5 KHz 내외로 한정하고 있는 문제점을 해소하기 위하여 새로운 형태의 적분기를 제안하였다. 이 적분기의 위상오차와 선택도가 정의 적호를 가지고 있어서 Thomas의 biquad회로망내의 Miller 적분기와 대치하면 원래의 부의 위상오차를 보상하여 전체회로망특성을 개선한다. Thoma의 biquad 도로를 본보상법에 의해서 개조한 대역통과여파기의 주파수특성을 측정한바 중심주파수가 20KHz 그리고 Q가 100에 이르기까지 만족할만한 응답을 보여 특성의 개선을 확인할 수 있었다.

  • PDF

電動力設備의 運轉에 의해 發生되는 磁界의 測定과 解析 (Analysis and Measurement of the Magnetic Fields Cause by Operation of Electromotive Installations)

  • 이복희
    • 한국조명전기설비학회지:조명전기설비
    • /
    • 제9권2호
    • /
    • pp.146-146
    • /
    • 1995
  • 본 논문은 유도전동기의 운전조작시에 발생되는 자계변화특성에 대하여 기술하였다. 본 측정시스템은 자기적분형 자계센서, 증폭기, 능동형 적분기로 이루어졌으며, 교정실험에 대한 측정계의 주파수대역과 감도는 각각 20[Hz]∼0.234[mV/μT]이다. 유도전동기의 기동과 정상운전중에 발생하는 자계성분을 측정하였으며, 고조파 성분을 고속 푸리에 변환기법으로 분석하였다. 유도전동기의 직입기동시에는 단일성 펄스자계가 강하게 발생하였으며, 이의 피크치는 정상상태의 값보다 5배이상 크게 나타났다. 이러한 긴 과도시간과 강한 자계의 세기는 전동기의 큰 인덕턴스와 동특성에 기인된다. 유도전동기의 정상운전시에는 유도전동기의 극수에 의존하는 기본파에 대한 분조파의 자계성분이 관측되었다. 또한, 자계의 분조파 성분은 전동기의 토크 변동으로 불균일한 회전토크로 인해 생기는 맥동전류와 전압플리커에 의해서 발생하는 것으로 생각된다. 인버터구동형 유도전동기에서는 직입기동에 비하여 많은 고조파 성분이 발생되고 있었으며, 특히 전동기의 구동주파수가 낮을수록 맥동토크에 의한 전류변화로 고조파 성분은 더욱 증가하였다.

계통연계형 단상 인버터의 ZVRT(Zero Voltage Ride Through)를 위한 PLL 제어 전략 (PLL Control Strategy for ZVRT(Zero Voltage Ride Through) of a Grid-connected Single-phase Inverter)

  • 이태일;이경수
    • 전력전자학회논문지
    • /
    • 제24권3호
    • /
    • pp.169-180
    • /
    • 2019
  • Grid codes for grid-connected inverters are essential considerations for bulk grid systems. In particular, a low-voltage ride-through (LVRT) function, which can contribute to the grid system's stabilization with the occurrence of voltage sag, is required by such inverters. However, when the grid voltage is under zero-voltage condition due to a grid accident, a zero-voltage ride-through (ZVRT) function is required. Grid-connected inverters typically have phase-locked loop (PLL) control to synchronize the phase of the grid voltage with that of the inverter output. In this study, the LVRT regulations of Germany, the United States, and Japan are analyzed. Then, three major PLL methods of grid-connected single-phase inverters, namely, notch filter-PLL, dq-PLL using an active power filter, and second-order generalized integrator-PLL, are reviewed. The proposed PLL method, which controls inverter output under ZVRT condition, is suggested. The proposed PLL operates better than the three major PLL methods under ZVRT condition in the simulation and experimental tests.

루우프형 센서를 이용한 자장측정계 (Magnetic Field Measuring System by using Loop-type Sensor)

  • 이복희;길경석;박동화
    • 센서학회지
    • /
    • 제4권2호
    • /
    • pp.14-21
    • /
    • 1995
  • 본 논문은 전력설비와 뇌방전에 의하여 발생하는 시변자장을 측정할 수 있는 능동성 자장측정계에 대하여 기술하였다. 자장측정계는 루우프형 센서, 차동증폭기로 동작되는 능동성 적분기로 이루어졌다. 시변자장측정계와 교정장치의 이론적 원리 및 설계방법에 대하여 제시하였으며, 교정실험으로부터 주파수대역 $270\;Hz\;{\sim}\;2.3\;MHz$, 응답감도 128 $mV/{\mu}T$를 얻었고, 교정실험계에서 자장센서범위의 자계의 세기는 ${\pm}3\;%$이내로 균일하였다. 적용실험으로는 대전류 발생장치에 의하여 모의 뇌임펄스전류와 진동성 임펄스전류를 발생시켜서 인가전류와 검출자장의 파형을 비교하였으며, 이의 결과는 거의 일치하였고, 편차는 0.5 %이내이었다.

  • PDF

USN/RFID Reader용 저전력 시그마 델타 ADC 변환기 설계에 관한 연구 (Design of Low Power Sigma-delta ADC for USN/RFID Reader)

  • 강이구;한득창;홍승우;이종석;성만영
    • 한국전기전자재료학회논문지
    • /
    • 제19권9호
    • /
    • pp.800-807
    • /
    • 2006
  • To enhance the conversion speed more fast, we separate the determination process of MSB and LSB with the two independent ADC circuits of the Incremental Sigma Delta ADC. After the 1st Incremental Sigma Delta ADC conversion finished, the 2nd Incremental Sigma Delta ADC conversion start while the 1st Incremental Sigma Delta ADC work on the next input. By determining the MSB and the LSB independently, the ADC conversion speed is improved by two times better than the conventional Extended Counting Incremental Sigma Delta ADC. In processing the 2nd Incremental Sigma Delta ADC, the inverting sample/hold circuit inverts the input the 2nd Incremental Sigma Delta ADC, which is the output of switched capacitor integrator within the 1st Incremental Sigma Delta ADC block. The increased active area is relatively small by the added analog circuit, because the digital circuit area is more large than analog. In this paper, a 14 bit Extended Counting Incremental Sigma-Delta ADC is implemented in $0.25{\mu}m$ CMOS process with a single 2.5 V supply voltage. The conversion speed is about 150 Ksamples/sec at a clock rate of 25 MHz. The 1 MSB is 0.02 V. The active area is $0.50\;x\;0.35mm^{2}$. The averaged power consumption is 1.7 mW.

시그마-델타 A/D 컨버터용 디지털 데시메이션 필터 설계 (Design of digital decimation filter for sigma-delta A/D converters)

  • 변산호;류성영;최영길;노형동;남현석;노정진
    • 대한전자공학회논문지SD
    • /
    • 제44권2호
    • /
    • pp.34-45
    • /
    • 2007
  • 오버샘플링(oversampling) 방식의 시그마-델타(sigma-delta) A/D 컨버터에서는 오버샘플링된 신호를 최종 Nyquist rate 으로 낮춰주는 디지털 데시메이션 필터가 필수적이다. 본 논문에서는 면적을 크게 줄이면서 time-to-market의 이점을 가져다주는 고해상도 시그마-델타(sigma-delta) A/D 컨버터용 디지털 데시메이션(decimation) 필터의 Verilog-HDL 설계 및 구현을 보였다. 디지털 데시메이션 필터는 CIC(cascaded integrator-comb) filter와 두 개의 half-band FIR filter로 이루어져 있다. FIR필터에서 곱셈연산의 복잡성을 줄이고 면적을 최소화하기 위해 계수를 CSD(canonical signed digit) 코드로 표현하여 사용하였다. 곱셈 연산은 일반 곱셈기 없이 쉬프트 와 덧셈방식을 이용하여 구현되었다. 3단 데시메이션 필터는 $0.25-{\mu}m$ CMOS 공정으로 제작되었고, 필터의 면적은 $1.36mm^2$ 이며 2.8224 MHz의 클럭 주파수에서 4.4 mW의 파워소모를 보였다. 측정 결과 높은 신호대 잡음 비(SNR)를 요구하는 디지털 오디오용 데시메이션(decimation) 필터의 사양을 충분히 만족시키고 있음을 볼 수 있다.

방사선 펄스의 고안정 계측 및 분석기술 개발 (Development of High Stable Instrumentation and Analytic Techniques for Radioactive Pulses)

  • 길경석;송재용;한주섭;김일권;손원진
    • 한국정보통신학회논문지
    • /
    • 제5권2호
    • /
    • pp.303-308
    • /
    • 2001
  • 본 연구의 목적은 방사선 펄스의 고안정 계측회로 및 분석시스템 개발에 있다. 제안한 시스템은 중성자 및 감마선 검출회로, 프로그래머블 고전압 공급장치 및 DSP로 구성된다. 프로그래머블 고전압 공급장치는 입력전압 5V에서 150V까지 조정할 수 있도록 하였으며 직렬의 전압 안정화 회로를 부가하여 일정한 전압이 유지되도록 함으로써 고전압 공급장치의 전압 변동율은 1.63%이하로 얻을 수 있었다. 방사선 검출회로는 능동성 적분기, 폴-제로 회로, 증폭도 60dB의 3단 증폭회로로 구성되며, 주파순 대역은 37 Hz~300 kHz이다. 또한 파고분포의 계수는 방사선 펄스의 분석에 중요한 자료로 본 연구에서는 A/D 컨버터(12bit 100㎱) 및 고속의 DSP(TMS320C31-60)을 이용하여 PC-기반으로 구현되는 파고분석 시스템을 구성하였다.

  • PDF