• 제목/요약/키워드: Active faults

검색결과 107건 처리시간 0.027초

해상풍력 연계용 HVDC의 DC전압 안정화를 위한 DC Link의 발전기측 컨버터 제어 전략 (Output Control of Wind Farm Side Converter from DC Link for DC Voltage Stabilization with HVDC)

  • 이형진;강병욱;허재선;김재철
    • 전기학회논문지
    • /
    • 제65권9호
    • /
    • pp.1479-1485
    • /
    • 2016
  • This paper presents DC voltage recovery time improvement method in DC link of High Voltage Direct Current (HVDC) with offshore wind farm. The wind farm should be satisfied Low Voltage Ride Through(LVRT) control strategy when grid faults occur. The LVRT control strategy indicates actions which have to be executed according to the voltage dip ratio and the fault duration. However, The LVRT control strategy makes between wind farm and power system through DC Link voltage when grid fault occurs. The de-loading scheme is one of the method to control the DC voltage. But de-loading scheme need to long DC voltage recovery time. Thus, this paper proposes an improved de-loading scheme and we analysis DC voltage and active power reference through a simulation.

Structural damage distribution induced by Wenchuan Earthquake on 12th May, 2008

  • Jia, Junfeng;Song, Nianhua;Xu, Zigang;He, Zizhao;Bai, Yulei
    • Earthquakes and Structures
    • /
    • 제9권1호
    • /
    • pp.93-109
    • /
    • 2015
  • Based on the reconnaissance of buildings in Dujiangyan City during 2008 Wenchuan earthquake, China, structural damage characteristics and the spatial distribution of structural damage are investigated, and the possible reasons for the extraordinary features are discussed with consideration of the influence of urban historical evolution and spatial variation of earthquake motions. Firstly, the urban plan and typical characteristics of structural seismic damage are briefly presented and summarized. Spatial distribution of structural damage is then comparatively analyzed by classifying all surveyed buildings in accordance with different construction age, considering the influence of seismic design code on urban buildings. Finally, the influences of evolution of seismic design code, topographic condition, local site and distance from fault rupture on spatial distribution of structural damage are comprehensively discussed. It is concluded that spatial variation of earthquake motions, resulting from topography, local site effect and fault rupture, are very important factor leading to the extraordinary spatial distribution of building damage except the evolution of seismic design codes. It is necessary that the spatial distribution of earthquake motions should be considered in seismic design of structures located in complicated topography area and near active faults.

Necessity and adequacy of near-source factors for seismically isolated buildings

  • Saifullah, Muhammad Khalid;Alhan, Cenk
    • Earthquakes and Structures
    • /
    • 제12권1호
    • /
    • pp.91-108
    • /
    • 2017
  • Superstructures and isolation systems of seismically isolated buildings located close to active faults may observe increased seismic demands resulting from long-period and high-amplitude velocity and displacement pulses existent in near-fault ground motions as their fundamental periods may be close to or coincident with these near-fault pulse periods. In order to take these effects into account, the 1997 Uniform Building Code (UBC97) has specified near-source factors that scale up the design spectrum depending on the closest distance to the fault, the soil type at the site, and the properties of the seismic source. Although UBC97 has been superseded by the 2015 International Building Code in the U.S.A., UBC97 near-source factors are still frequently referred in the design of seismically isolated buildings around the world. Therefore it is deemed necessary and thus set as the aim of this study to assess the necessity and the adequacy of near-source factors for seismically isolated buildings. Benchmark buildings of different heights with isolation systems of different properties are used in comparing seismic responses obtained via time history analyses using a large number of historical earthquakes with those obtained from spectral analyses using the amplified spectrums established through UBC97 near-source factors. Results show that near-source factors are necessary but inadequate for superstructure responses and somewhat unconservative for base displacement response.

The geomorphic characteristics of Bulguksa-region and the earthquake resistant structure of the Bulguksa-Temple

  • Hwang, Sang-Ill
    • 한국제4기학회지
    • /
    • 제22권2호
    • /
    • pp.1-5
    • /
    • 2008
  • Some reverse fault lines pass through the alluvial fans and west hill slope of Bulguksa mountains including Mt. Toham in the directions of N-S and NW-SE. The study area is known as relatively unstable, because of active faults. Assuming the record of earthquake in the Samguksagi, the architects in the construction of the Bulguksa temple should have recognized the possibility of breakdown from the earthquakes and the need for an unique structure against at that time. Against earthquakes, Greavee technique, a stonework construction technique following woothe one and use of Chushouok (Dongtleouok or Chumchaouok) were applied for the construction of Bulguksa temple. By designing the foundation stone with hole, a structure is prevented from motiff Ction that pillarsakdcede from a foundation stone in spite of horizontal load of earthquake while woot construction isaktrong frame at earthquake. The Bulguksa-temple isausually evaluated to be a beautiful architecture from the appeaultces like the weight balltced structure with unique decoration. ampressive architectures are beautiful in balance and harmony coming from the important and specific rolls in its own way by each part of whole structure. This beauty comes from the science.

  • PDF

Lock-In Thermography Based NDT of Parts for the Automotive Industry

  • Bohm, Stefan;Hellmanns, Mark;Backes, Andreas;Dilger, Klaus
    • 접착 및 계면
    • /
    • 제7권4호
    • /
    • pp.10-12
    • /
    • 2006
  • The successful use of adhesively bonded parts depends on the defect-free bond of the components. Therefore it is necessary to detect relevant faults and defects in an early state of the production. A 100% test should be pursued, but especially at complicated structures the detection of defects is not easy. Possible testing methods, which show a high potential for the NDT of adhesively bonded parts, are thermography based NDT methods. At present mainly two different procedures of active thermography are being used: Pulse and Lock-In Thermography. With pulse thermography the examined material is warmed up with a short energy pulse (light, eddy current or ultrasonic pulse) and the heat response is recorded after a certain time. The result is an infrared image which indicates material defects in different depths. This paper presents a variety of images showing the capability of Lock-In Thermography to image subsurface defects. Several examples of adhesives joints qualify the ultrasonic Lock-In-Thermography for the in-process quality control for adhesive bonded components.

  • PDF

Seismicity and seismic hazard assessment for greater Tehran region using Gumbel first asymptotic distribution

  • Bastami, Morteza;Kowsari, Milad
    • Structural Engineering and Mechanics
    • /
    • 제49권3호
    • /
    • pp.355-372
    • /
    • 2014
  • Considering the history of severe earthquakes and the presence of active faults in the greater Tehran region, the possibility of a destructive earthquake occurring is high and seismic hazard analysis is crucial. Gumbel distributions are commonly-used statistical distributions in earthquake engineering and seismology. Their main advantage is their basis on the largest earthquake magnitudes selected from an equal-time predefined set. In this study, the first asymptotic distribution of extremes is used to estimate seismicity parameters and peak ground acceleration (PGA). By assuming a Poisson distribution for the earthquakes, after estimation of seismicity parameters, the mean return period and the probable maximum magnitude within a given time interval are obtained. A maximum probable magnitude of 7.0 has a mean return period of 100 years in this region. For a return period of 475 years, the PGA in the greater Tehran region is estimated to be 0.39g to 0.42g, depending on local site conditions. This value is greater than that of the Iranian Code for Seismic Design of Buildings, indicating that a revision of the code is necessary.

The Design of Fault Tolerant Dual System and Real Time Fault Detection for Countdown Time Generating System

  • Kim, Jeong-Seok;Han, Yoo-Soo
    • 한국컴퓨터정보학회논문지
    • /
    • 제21권10호
    • /
    • pp.125-133
    • /
    • 2016
  • In this paper, we propose a real-time fault monitoring and dual system design of the countdown time-generating system, which is the main component of the mission control system. The countdown time-generating system produces a countdown signal that is distributed to mission control system devices. The stability of the countdown signal is essential for the main launch-related devices because they perform reserved functions based on the countdown time information received from the countdown time-generating system. Therefore, a reliable and fault-tolerant design is required for the countdown time-generating system. To ensure system reliability, component devices should be redundant and faults should be monitored in real time to manage the device changeover from Active mode to Standby mode upon fault detection. In addition, designing different methods for mode changeover based on fault classification is necessary for appropriate changeover. This study presents a real-time fault monitoring and changeover system, which is based on the dual system design of countdown time-generating devices, as well as experiment on real-time fault monitoring and changeover based on fault inputs.

A Fast and Robust Grid Synchronization Algorithm of a Three-phase Converters under Unbalanced and Distorted Utility Voltages

  • Kim, Kwang-Seob;Hyun, Dong-Seok;Kim, Rae-Yong
    • Journal of Electrical Engineering and Technology
    • /
    • 제12권3호
    • /
    • pp.1101-1107
    • /
    • 2017
  • In this paper, a robust and fast grid synchronization method of a three-phase power converter is proposed. The amplitude and phase information of grid voltages are essential for power converters to be properly connected into the utility. The phase-lock-loop in synchronous reference frame has been widely adopted for the three-phase converter system since it shows a satisfactory performance under balanced grid voltages. However, power converters often operate under abnormal grid conditions, i.e. unbalanced by grid faults and frequency variations, and thus a proper active and reactive power control cannot be guaranteed. The proposed method adopts a second order generalized integrator in synchronous reference frame to detect positive sequence components under unbalanced grid voltages. The proposed method has a fast and robust performance due to its higher gain and frequency adaptive capability. Simulation and experimental results show the verification of the proposed synchronization algorithm and the effectiveness to detect positive sequence voltage.

RF 집적회로의 시간영역 테스팅을 위한 사양기반 구간고장모델링 (Band Fault Modelling Based on specification for the Time Domain Test of RFIC)

  • 김강철;한석붕
    • 한국정보통신학회논문지
    • /
    • 제12권2호
    • /
    • pp.299-308
    • /
    • 2008
  • 본 논문에서는 RF 집적회로의 설계사양을 시간영역에서 테스팅이 가능한 구간고장모델링 기법을 제안한다. 먼저 구간고장모델을 정의하였고, 정상동작구간을 결정하여 구간고장모델이 될 수 있는 조건을 증명하였다. 그리고 구간고장모델 조건을 5.25 GHz 저잡음 증폭기에 적용하여 능동소자와 수동소자의 강고장과 파라메트릭 고장의 검출이 가능한 9개의 구간고장모델을 모의실험에 의하여 구하였다. 본 논문에서 얻어진 구간고장모델을 기반으로 출력에 나타나는 출력파형의 변화를 시간영역에서 관찰하여 설계사양 테스팅을 수행할 수 있으므로 RF 집적회로의 테스팅 시간과 비용을 줄일 수 있다.

Attenuation of High-Frequency Lg Waves around the Yangsan Fault area, the Southeast Korea

  • 정태웅;이기화
    • 지구물리
    • /
    • 제5권1호
    • /
    • pp.1-8
    • /
    • 2002
  • 한반도 남동지역에서의 Lg 감쇠 연구는 산업 지역에 놓인 활성단층으로 여겨지는 양산단층의 존재로 매우 중요하다. 두 관측점법에 의한 Lg 감쇠를 해석한 결과, 0.87 - 10 Hz 구간이 $${\gamma}=(0.009±0.0005)\;f^{0.06+0.03}$$이다. ${\gamma}$값에서 변환된 ${Q_{Lg}}^{-1}$값은 동일한 지역에서 측정된 S파의 값보다 매우 높고, 10Hz 가까운 영역에서는 세계에서도 가장 높은 수준이 검출되었다. 이 높은 값은 동해에 의한 Lg 차단 효과이거나, 조사지역의 지각두께 변화와 연관이 된 것으로 보인다.

  • PDF