• 제목/요약/키워드: Active control

검색결과 6,351건 처리시간 0.031초

능동 공기 베어링에 의한 로터계 동기진동의 PID제어 (PID Control of a Synchronous Rotor System Vibration with Active Air Bearing)

  • 권대규;이영춘;이성철
    • 한국정밀공학회지
    • /
    • 제18권8호
    • /
    • pp.32-39
    • /
    • 2001
  • This paper presents the synchronous vibration control of a rotor system using an Active Air Bearing(AAB). In order to suppress the synchronous vibration, it is necessary to actively control the air film pressure or the air film thickness. In this study, active pads are used to control the air film thickness. Active pads are supported by the pivots containing piezoelectric actuators and their radial positions can be actively controlled by applying voltage to the actuators. Disturbances and various kinds of external force can cause the shaft vibration as well as the change of the air film thickness. The dynamic behaviors of a rotary system supported by two tilting-pad gas bearings and its active stabilization using the tilting-pads as actuators are investigated numerically. The PID controller is applied to the tilting-pad gas bearing system with three pads, two of which contain piezoelectric actuators. To test the vapidity of the theoretical method, the performance of this control method is evaluated through experiments. The experimental results show the effectiveness of the control system for suppressing the unbalanced response of the rigid modes.

  • PDF

슬괵근 단축 유무에 따른 요통환자에 대한 능동적 움직임 조절 검사의 타당도 연구 (The Study of Validity in Active Movement Control test for Low Back Pain Patients with or without Hamstring Shortening)

  • 오세준;최종덕
    • 대한물리의학회지
    • /
    • 제7권4호
    • /
    • pp.443-450
    • /
    • 2012
  • PURPOSE: This study was investigated to find the validity of active movement control test for low back pain patients with or without hamstring shortening. METHODS: The subjects of this study were 28 subjects and all of them agreed to participate in the study. All subjects were classified according to 4groups. Group1 was no LBP, no hamstring shortening. Group2 was no LBP, hamstring shortening. Group3 was LBP, no hamstring shortening. Group4 was LBP, hamstring shortening. We measured to see their low back pain and hamstring shortening with VAS, Goniometer for active movement control test. We analyzed the data using Cochran Q test and crosstabulation for agreement index. RESULTS: The results of this study were as follows : 1) Low back pain had effect on active movement control by Group1 and Group2. 2) Hamstring had effect on active movement control by Group1 and Group2 3)Low back pain with or without hamstring shortening had effect on active movement control by Group4 CONCLUSION: According the results of this study, active movement control test were significantly influenced on low back pain and hamstring interaction.

전자기력을 이용한 능동제진

  • 손규태;유원희;박영필
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2001년도 추계학술대회 논문집
    • /
    • pp.179-183
    • /
    • 2001
  • Vibration isolation of mechanical systems, in general is achieved through either passive or active vibration control system. Although passive vibration isolators offer simple and reliable means to protect mechanical system from vibration environment, passive vibration isolator has inherent performance limitation. Whereas, active vibration isolator provide significantly superior vibration-isolation performance. Recently, many studied and applications are carried out in this field. In this study, vibration-isolation characteristics of active vibration control system using electromagnetic force actuator are investigated. Some control algorithms. Optimal Feedforward are used for active vibration isolation. Form the experimental results of each control algorithms, active vibration isolation characteristics are investigated.

승차감 향상을 위한 자동차 현가장치의 반능동제어에 관한 연구 (Semi-active control of a vehicle suspension for the ride quality improvement)

  • 박호;오재응
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 1990년도 한국자동제어학술회의논문집(국내학술편); KOEX, Seoul; 26-27 Oct. 1990
    • /
    • pp.783-788
    • /
    • 1990
  • Computer simulation is carried out for passive, active, and semi-active suspension system. Each RMS and frequency response to road profile input is calculated for comparison and evaluation of the performance. The vibration analysis and active control of the quarter model of a vehicle suspension is studied in order to evaluate the alternative control laws. This paper derives an optimal closed-loop feedback law for the semi-active suspension that justifies the clipped optimal approach.

  • PDF

Improvement in Active Power Control Methods for a Wind Farm Based on Modified Wind Turbine Control in Danish Grid Codes

  • Sim, JunBo;Song, Il-Keun;Lee, Yongseung;Lee, Hak-Ju;Choi, Yun-Hyuk
    • Journal of Electrical Engineering and Technology
    • /
    • 제13권4호
    • /
    • pp.1438-1449
    • /
    • 2018
  • The importance of power system stability has been emphasized with an increase of wind energy penetration in the power system. Accordingly, the guarantee on various control capabilities, including active and reactive power control of wind farms, was regarded as the most important aspect for the connection to the grid. To control the wind farm active power, the wind farm controller was introduced. The wind farm controller decides the power set points for each wind turbine generating unit and each wind turbine generating unit controls its power according to the set points from the wind farm controller. Therefore, co-relationship between wind farm controller and wind turbine controllers are significantly important. This paper proposes some control methods of wind farm active power control based on modified wind turbine control for power system stability and structures to connect wind turbine controllers to wind farm controller. Besides, this paper contributes to development of control algorithm considering not only electrical components but also mechanical components. The proposed contributions were verified by full simulation including power electronics and turbulent wind speed. The scenario refers to the active power control regulations of the Eltra and Elkraft system in Denmark.

Flyback Converter Active Balancing BMS 적용 유·무에 따른 리튬폴리머 이차전지 가용시간 분석 (Analysis of Operating Time of Li-polymer Secondary Cell with or Without Flyback Converter Active Balancing BMS)

  • 김영필;최철형;고석철;김시경
    • 전기학회논문지
    • /
    • 제66권5호
    • /
    • pp.786-791
    • /
    • 2017
  • In this paper, the run time of Li-polymer secondary cell with and without Active Balancing BMS is analyzed. The Active Balancing System using Flyback Converter with two-way power control facility, his designed for optimal characteristics of balancing. The run time of Li-polymer secondary cell is drastically increased employing the Flyback Convert Active Balancing BMS. The run time performance of Li-polymer secondary cell with or without Flyback Converter Active Balancing BMS is analyzed with the discharging and charging experiment of Li-polymer secondary cell.

Active tendon control of suspension bridges: Study on the active cables configuration

  • Tian, Zhui;Mokrani, Bilal;Alaluf, David;Jiang, Jun;Preumont, Andre
    • Smart Structures and Systems
    • /
    • 제19권5호
    • /
    • pp.463-472
    • /
    • 2017
  • In a previous study, the potential of damping suspension bridges with active stay cables has been evaluated on a numerical model of a suspension bridge, and demonstrated experimentally on a laboratory mockup. In this paper, we extend our study to explore two different configurations of the active stay-cables: one classical configuration, corresponding to attaching the active stay-cables between the top of the pylons and the deck (configuration I) and, another configuration, consisting of attaching the stay-cables between the base of the pylons and the catenary (configuration II). The analysis confirmed that both configurations are effective with a slight superiority of the second configuration. The study is conducted numerically and experimentally on a suspension bridge mock-up, by considering two types of active stay-cables. The experimental results confirmed the numerical predictions, and demonstrated the effectiveness of the second configuration.

Effective vibration control of multimodal structures with low power requirement

  • Loukil, Thamina;Ichchou, Mohamed;Bareille, Olivier;Haddar, Mohamed
    • Smart Structures and Systems
    • /
    • 제13권3호
    • /
    • pp.435-451
    • /
    • 2014
  • In this paper, we investigate the vibration control of multimodal structures and present an efficient control law that requires less energy supply than active strategies. This strategy is called modal global semi-active control and is designed to work as effectively as the active control and consume less power which represents its major limitation. The proposed law is based on an energetic management of the optimal law such that the controller follows this latter only if there is sufficient energy which will be extracted directly from the system vibrations itself. The control algorithm is presented and validated for a cantilever beam structure subjected to external perturbations. Comparisons between the proposed law performances and those obtained by independent modal space control (IMSC) and semi-active control schemes are offered.

Seismic response control of buildings with force saturation constraints

  • Ubertini, Filippo;Materazzi, A. Luigi
    • Smart Structures and Systems
    • /
    • 제12권2호
    • /
    • pp.157-179
    • /
    • 2013
  • We present an approach, based on the state dependent Riccati equation, for designing non-collocated seismic response control strategies for buildings accounting for physical constraints, with particular attention to force saturation. We consider both cases of active control using general actuators and semi-active control using magnetorheological dampers. The formulation includes multi control devices, acceleration feedback and time delay compensation. In the active case, the proposed approach is a generalization of the classic linear quadratic regulator, while, in the semi-active case, it represents a novel generalization of the well-established modified clipped optimal approach. As discussed in the paper, the main advantage of the proposed approach with respect to existing strategies is that it allows to naturally handle a broad class of non-linearities as well as different types of control constraints, not limited to force saturation but also including, for instance, displacement limitations. Numerical results on a typical building benchmark problem demonstrate that these additional features are achieved with essentially the same control effectiveness of existing saturation control strategies.

Chaotic particle swarm optimization in optimal active control of shear buildings

  • Gharebaghi, Saeed Asil;Zangooeia, Ehsan
    • Structural Engineering and Mechanics
    • /
    • 제61권3호
    • /
    • pp.347-357
    • /
    • 2017
  • The applications of active control is being more popular nowadays. Several control algorithms have been developed to determine optimum control force. In this paper, a Chaotic Particle Swarm Optimization (CPSO) technique, based on Logistic map, is used to compute the optimum control force of active tendon system. A chaotic exploration is used to search the solution space for optimum control force. The response control of Multi-Degree of Freedom (MDOF) shear buildings, equipped with active tendons, is introduced as an optimization problem, based on Instantaneous Optimal Active Control algorithm. Three MDOFs are simulated in this paper. Two examples out of three, which have been previously controlled using Lattice type Probabilistic Neural Network (LPNN) and Block Pulse Functions (BPFs), are taken from prior works in order to compare the efficiency of the current method. In the present study, a maximum allowable value of control force is added to the original problem. Later, a twenty-story shear building, as the third and more realistic example, is considered and controlled. Besides, the required Central Processing Unit (CPU) time of CPSO control algorithm is investigated. Although the CPU time of LPNN and BPFs methods of prior works is not available, the results show that a full state measurement is necessary, especially when there are more than three control devices. The results show that CPSO algorithm has a good performance, especially in the presence of the cut-off limit of tendon force; therefore, can widely be used in the field of optimum active control of actual buildings.