• 제목/요약/키워드: Active and reactive power

검색결과 446건 처리시간 0.032초

농형유도 풍력발전기의 성능개선을 위한 에너지 저장장치의 동작특성 분석 (Operational Analysis of Energy Storage System to Improve Performance of Wind Power System with Induction Generator)

  • 심명보;한병문
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2009년도 제40회 하계학술대회
    • /
    • pp.1045_1046
    • /
    • 2009
  • This paper presents an active and reactive power compensator for the wind power system with squirrel-cage induction generator. The developed system is able to continuously compensate the active and reactive power. The 3-phase inverter operates for the compensation of reactive power, while the DC/DC converter with super-capacitors operates for the compensation of active power. The proposed compensator can be expected that developed system may be used to compensated the abrupt power variation due to sudden change of wind speed or sudden power-drop by tower effect. It can be also applied for the distributed generation and the Micro-Grid.

  • PDF

유무효전력설비의 적소투입을 통한 전력손실개선 (System Loss Improvement through Proper Location of Active and Reactive Power Apparatus)

  • 이상중
    • 조명전기설비학회논문지
    • /
    • 제14권3호
    • /
    • pp.77-80
    • /
    • 2000
  • 본 논문은 有無效 섣둡jJ設觸의 投貴위치와 그 용향을 적정화하여 동일한 설비투자량에 대하여 전력손실을 최소화하는 방안에 대하여 설명하였다. 유효 및 무효전릭의 미소증분에 대한 손실의 변화를 나타내는 모선의 손실감도를 소개하고 전력송실을 최대한 개선하기 워한 유무효전력 설비의 투자지표로 이용하였다. 각 모선에 주어지는 투자지표의 우선순위에 따라 유효 및 무효전력설비가 투자되어 전력손실을 최소화한다.

  • PDF

Multi-Function Distributed Generation with Active Power Filter and Reactive Power Compensator

  • Huang, Shengli;Luo, Jianguo
    • Journal of Power Electronics
    • /
    • 제18권6호
    • /
    • pp.1855-1865
    • /
    • 2018
  • This paper presents a control strategy for voltage-controlled multi-function distributed generation (DG) combined with an active power filter (APF) and a reactive power compensator. The control strategy is based on droop control. As a result of local nonlinear loads, the voltages of the point of common coupling (PCC) and the currents injecting into the grid by the DG are distorted. The power quality of the PCC voltage can be enhanced by using PCC harmonic compensation. In addition, with the PCC harmonic compensation, the DG offers a low-impedance path for harmonic currents. Therefore, the DG absorbs most of the harmonic currents generated by local loads, and the total harmonic distortion (THD) of the grid connected current is dramatically reduced. Furthermore, by regulating the reactive power of the DG, the magnitude of the PCC voltage can be maintained at its nominal value. The performance of the DG with the proposed control strategy is analyzed by bode diagrams. Finally, simulation and experimental results verify the proposed control strategy.

무효전력 제어에 의한 PCC전압 보상을 갖는 삼상 병렬형 능동전력필터 (A Three-Phase Parallel Active Power Filter Operating with PCC Voltage Compensation by Controlling Reactive Power)

  • 이우철;현동석;이택기
    • 대한전기학회논문지:전기기기및에너지변환시스템부문B
    • /
    • 제49권3호
    • /
    • pp.211-218
    • /
    • 2000
  • The performance and dynamic characteristics of three-phase active power filter with PCC voltage compensation is presented and analyzed in this paper. The characteristics of parallel active filter are discussed when they are applied to nonlinear loads with current source and voltage source type, the characteristics of voltage compensator and comparison of two functions are discussed. The proposed scheme in this paper employs a PWM voltage-source inverter and has two operation modes. First, it operates as a conventional active filter with reactive power compensation while PCC voltage is in a certain range. Second, is operates as a voltage compensator while PCC voltage is out of range. Finally, the validity of this scheme is investigated through analysis of simulation and experimental results for a prototype active power filter system rated at 10KVA.

  • PDF

싸이리스터 컨버터부하에 적용되는 병렬형 능동필터의 적정용량산정 (Capacity Requirement Estimation of Shunt Active Power Filter for Thyristor Converter Load)

  • 박노중;정승기
    • 대한전기학회논문지:전기기기및에너지변환시스템부문B
    • /
    • 제48권12호
    • /
    • pp.715-726
    • /
    • 1999
  • This paper estimates the capacity of shunt type active power filters(APF) for harmonic/reactive power compensation with a thyristor converter load. The base capacity requirement of APF is defined for idealized converter load current waveform and the effect of commutation overlap on the APF capacity is examined. The APF capacity required for reactive power compensation in addition to the harmonic elimination is estimated to give maximum achievable power factor for various operating condition of the partially-loaded thyristor converter. The method of current limit of APF is introduced, and it is shown that the APF capacity can be considerably reduced by deliberately limiting the peak current while maintaining the filtering performance to meet the level std 519 regulation.

  • PDF

대용량 고전압 부하의 무효전력 및 고조파 보상을 위한 낮은 DC 전압을 갖는 새로운 능동 파워 필터 (New active power filter with low DC voltage for compensation of reactive power and harmonics of high power/voltage load)

  • 정구호;조규형
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 1998년도 전력전자학술대회 논문집
    • /
    • pp.291-294
    • /
    • 1998
  • This paper presents a new active power filter with low DC voltage for compensating reactive power and harmonics of three-phase high power/voltage harmonic producing load. It has a structure of converter connected in series with power factor correction capacitor. Appropriate size and number of filter capacitor are determined by an equation and applied to simulation of 10kvar 6-pulse SCR rectifier.

  • PDF

배전용 정지형 보상기의 상태관측기를 이용한 순시 유효/무효전력 보상 (Instantaneous Active/Reactive Power Compensation of Distribution Static Compensator using State Observer)

  • 김형수;최종우
    • 전기학회논문지
    • /
    • 제57권8호
    • /
    • pp.1377-1382
    • /
    • 2008
  • DSTATCOM(distribution static compensator) is one of the custom power devices, and protects a distribution line from unbalanced and harmonic current caused by non-linear and unbalanced loads. Researches about DSTATCOM are mainly divided two parts, one is the calculation of compensation current and the other part is the current control. Conventional researches use a LPF(low pass filter) to eliminate ripple component at the calculation of compensation current. But this method has a problem that LPF's characteristics restrict the compensation performance of instantaneous active and reactive power. This paper proposes a calculation of compensation current using state observer that can be a counterproposal of conventional methods using LPF. Improved performance of instantaneous active and reactive power compensation was shown by experiments.

Proposing a New Method for Calculating Reactive Power Service Charges using the Reactive Power Market

  • Ro, Kyoung-Soo;Park, Sung-Jin
    • KIEE International Transactions on Power Engineering
    • /
    • 제4A권4호
    • /
    • pp.262-267
    • /
    • 2004
  • With the advent of electric power systems moving from a vertically integrated structure to a deregulated environment, calculating reactive power service charges has become a new and challenging theme for market operators. This paper examines various methods for reactive power management adopted throughout various deregulated foreign and domestic markets and then proposes an innovative method to calculate reactive power service charges using a reactive power market in a wholesale electricity market. The reactive power market is operated based on bids from the generating sources and it settles on uniform prices by running the reactive OPF programs of the day-ahead electricity market. The proposed method takes into account recovering not only the costs of installed capacity but also the lost opportunity costs incurred by reducing active power output to increase reactive power production. Based on the result of the reactive OPF program, the generators that produce reactive power within the obligatory range do not make payments whereas the generators producing reactive power beyond the obligatory range receive compensation by the price determined in the market. A numerical sample study is carried out to illustrate the processes and appropriateness of the proposed method.

Graphical Representation of the Instantaneous Compensation Power Flow for Single-Phase Active Power Filters

  • Jung, Young-Gook
    • Journal of Electrical Engineering and Technology
    • /
    • 제8권6호
    • /
    • pp.1380-1388
    • /
    • 2013
  • The conventional graphical representation of the instantaneous compensation power flow for single-phase active power filters(APFs) simply represents the active power flow and the reactive power flow which flowing between the power source and the active filter / the load. But, this method does not provide the information about the rectification mode and the compensation mode of APFs, especially, the loss for each mode was not considered at all. This is very important to understand the compensation operation characteristics of APFs. Therefore, this paper proposes the graphical representation of the instantaneous compensation power flow for single-phase APFs considering the instantaneous rectification mode and the instantaneous inversion mode. Three cases are verified in this paper - without compensation, with compensation of the active power 'p' and the fundamental reactive power 'q', and with compensation of only the distorted power 'h'. To ensure the validity of the proposed approach, PSIM simulation is achieved. As a result, we could confirm that the proposed approach was easy to explain the instantaneous compensation power flow considering the instantaneous rectification mode and the instantaneous inversion mode of APFs, also, Total Harmonic Distortion(THD)/Power Factor (P.F) and Fast Fourier Transform(FFT) analysis were compared for each case.

Control Strategy and Characteristic Analysis of Hybrid Active Power Filters with the Resonant Impedance Principle

  • Fang, Lu;Xu, Xian-Yong;Luo, An;Li, Yan;Tu, Chun-Ming;Fang, Hou-Hui
    • Journal of Power Electronics
    • /
    • 제12권6호
    • /
    • pp.935-946
    • /
    • 2012
  • A new kind of resonant impedance type hybrid active filter (RITHAF) is proposed for dynamic harmonic current suppression and high capacity reactive compensation in medium and high voltage systems. This paper analyzed the different performance of the RITHAF when the active part of the RITHAF is controlled as a current source and as a voltage source, respectively. The harmonic suppression function is defined in this paper. The influences of the changes caused by the grid impedance and the detuning of the passive power filter on the compensating characteristics of the RITHAF are studied by analyzing the suppression function. Simulation and industrial application results show that the RITHAF has excellent performances in harmonic suppression and reactive compensation, which is suitable for medium and high voltage systems.