• Title/Summary/Keyword: Active Switch

Search Result 315, Processing Time 0.028 seconds

High Efficiency Active Clamp Forward Converter with Synchronous Switch Controlled ZVS Operation (동기 스위치 제어를 통한 영전압 동작 고효율 능동 클램프 포워드 컨버터)

  • Lee, Sung-Sae;Cho, Seong-Wook;Moon, Gun-Woo
    • Proceedings of the KIPE Conference
    • /
    • 2005.07a
    • /
    • pp.266-268
    • /
    • 2005
  • A new synchronous switch controlled transient current build-up zero voltage switching (TCB-ZVS) forward converter is proposed. The proposed converter is suitable for the low-voltage and high-current applications. The features of the proposed converter are low conduction loss of magnetizing current, no additional circuit for the ZVS operation, high efficiency, high power density and low EMI noise throughout all load conditions.

  • PDF

A Study on the Design of the High Power Active Clamp ZVS Flyback Converter for Semiconductor Plasma Etching System (반도체 플라즈마 용융장치용 고출력 능동 클램프 ZVS 플라이백 컨버터 설계에 관한 연구)

  • 이우석
    • Proceedings of the KIPE Conference
    • /
    • 2000.07a
    • /
    • pp.400-403
    • /
    • 2000
  • This paper deals with the active clamp ZVS flyback converter for semiconductor plasma etching system. The proposed converter has the characteristics of the good power facter low switching noise and efficiency improvement. The characteristics are verified through simulation results. Furthermore the ringing effect due to output capacitance of the main switch can be eliminated by use of active clamp circuit.

  • PDF

Large-Signal Transient Analysis of a Self-Driven Active-Clamp Forward Converter (자기 구동 능동 클램프 포워드 컨버터의 대신호 과도 특성 해석)

  • Bong Sang-Cheol;Kim Hee-Jun
    • Proceedings of the KIEE Conference
    • /
    • summer
    • /
    • pp.1235-1238
    • /
    • 2004
  • This paper presents the large-signal transient analysis of a self-driven active-clamp forward converter, eliminating the extra drive circuit for the active clamp switch. The operation principle of the converter was presented and experiential results were used to verify the analyzed results. A 50-W prototype converter built and tested it. From the tested results, input transient response and load transient response of the converter were established.

  • PDF

Design of A 2KW Soft-Switching ZVT Power Factor Correction Converter With Active Snubbers

  • Park, Kyoung-Soo;Kim, Yoon-Ho
    • Proceedings of the KIPE Conference
    • /
    • 2001.10a
    • /
    • pp.790-794
    • /
    • 2001
  • In this paper a soft switching ZVT power factor converter using active snubbers is designed to improve efficiency and reduce voltage spike and parasitic ringing. The main switch achieves ZVT and the auxiliary switch performs with ZCS. A 2KW soft switching ZVT converter is designed with switching frequency 100kHz, output voltage 400VDC. Then the designed system is realized and experimental results show that the measured efficiency and power factor are over $97.45\%$ and 0.997 respectively with an input current THD less than $3\%$.

  • PDF

Active Resonant Snubber for Ideal Switched PWM Converter (능동형 공진 스너버)

  • Moon, Gun-Woo;Lee, Jung-Hoon;Jung, Young-Seok;Youn, Myung-Joong
    • Proceedings of the KIEE Conference
    • /
    • 1994.07a
    • /
    • pp.412-414
    • /
    • 1994
  • A new active resonant snubber (ARS) circuit providing the ideal switching conditions for PWM converter is presented. By using the proposed ARS circuit to PWM converters, the power switches can be operated to give zero-current and zero-voltage at both the instant of switch off and switch on, without increasing voltage/current stresses of the switches. Furthermore, the PWM converters employed ARS circuit has the advantage that it can operate at constant frequency, giving better definded EMI and filter ripple, and it is also suited for high-power application regardless of the semiconductor devices (such as MOSFETs or IGBTs) used as a power switches.

  • PDF

A Study on the New Control Scheme of Class-I Inverter for IH-Jar Applications with Clamped Voltage Characteristics Using Pulse frequency Modulation (주파수 변조 기법을 이용한 전압 클램프 특성을 갖는 유도가열용 Class-E 인버터의 새로운 제어에 관한 연구)

  • 이동윤;최영덕;현동석
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.52 no.3
    • /
    • pp.133-139
    • /
    • 2003
  • In this paper, a new control scheme of Class-E inverter for Induction Heating (IH) Jar applications with clamped voltage characteristics using Pulse-Frequency-Modulation (PFM) is introduced. To reduce the voltage stress of switch, the proposed PFM control scheme doesn't need any auxiliary circuit in comparison to a family of Active Clamped Class-E (ACCE) inverter. It can decrease voltage stress of switch through modulation of switching frequency. The Class-E inverter using the proposed control scheme has the advantage of not only the same output power when it is compared with a Hybrid-Active Clamped Class-E (Hybrid-ACCE) inverter but also Zero-Voltage-Switching (ZVS), which are characteristics of conventional Class-E and ACCE inverter. The control principles and analysis of proposed method are explained in detail and its validity is verified through simulation and experimental results.

Design of a 2KW Soft-Switching ZVT Power Factor Correction Converter with Active Snubbers (능동 스너버를 갖는 2KW 소프트 스위칭 ZVT 역률 보정 컨버터 설계)

  • Park, Gyeong-Su;Kim, Yun-Ho
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.50 no.9
    • /
    • pp.473-478
    • /
    • 2001
  • In this paper a soft switching ZVT(Zero Voltage Transition) power factor converter using active snubbers is designed to improve efficiency and reduce voltage spike and parasitic ringing. The main switch achieves ZVT and the auxiliary switch operates with ZCS. A 2KW soft switching ZVT converter is designed with switching frequency 100kHz, output voltage 400VDC. Then the designed system is realized and experimental results show that the measured efficiency and power factor are over 97.45% and 0.997 respectively with an input current THD less than 3%.

  • PDF

Improved ZVT AC/DC PFC Boost Converter (개선된 ZVT AC/DC PFC Boost 컨버터)

  • Ryu, Jong-Gyu;Kim, Yong;Bae, Jin-Yong;Gye, Sang-Bum;Kwon, Soon-Do
    • Proceedings of the KIEE Conference
    • /
    • 2005.04a
    • /
    • pp.172-175
    • /
    • 2005
  • Recently international regulations governing the amount of harmonic currents(e.g IEC 61000-3-2) became mandatory and active Power factor correction (PFC) pre-regulator circuit became inevitable for the AC/DC converters. Among these topologies, the boost topology represents an optimum solution for a PFC pre-regulation in a high power application. This paper propose improved ZVT(Zero Voltage Transition) AC/DC PFC Boost using the average current control employing a soft-switching technique of the auxiliary switch with a minimum number of components. The conventional ZVT PFC Boost Converter has a disadvantage that the auxiliary switch turns off hard, which influences the overall efficiency and the EMI problem. In this paper, an improved ZVT PFC Boost converter using active snubber is proposed to minimize the switching loss of the auxiliary. The prototype of 100kHz, 640W system was implemented to show the improved performance.

  • PDF

Design of A 2KW Soft-Switching ZVT Power Factor Correction Converter with Active Snubbers (능동 스너버를 갖는 2KW 소프트 스위칭 ZVT 역률 보정 컨버터 설계)

  • Park Kyoung-Soo;Kim Yoon-Ho;Park Kyoung-Soo
    • Proceedings of the KIPE Conference
    • /
    • 2001.07a
    • /
    • pp.677-680
    • /
    • 2001
  • In this paper a soft switching ZVT power factor converter using active snubbers is designed to improve efficiency and reduce voltage spike and parastic ringing. The main switch achieves ZVT and the auxiliary switch performs with ZCS. A 2KW soft switching ZVT converter is designed with switching frequency 100kHz, output voltage 400VDC. Then the designed system is realized and experimental results shows that the measured efficiency and power factor were over $97.45\%$ and 0.997 respectively with an input current THD less than $3\%$.

  • PDF

A Novel Single Phase Soft Switched PFC Converter

  • Altintas, Nihan
    • Journal of Electrical Engineering and Technology
    • /
    • v.9 no.5
    • /
    • pp.1592-1601
    • /
    • 2014
  • In this study, a novel single phase soft switched power factor correction (PFC) converter is developed with active snubber cell. The active snubber cell provides boost switch both to turn on with zero voltage transition (ZVT) and to turn off with zero current transition (ZCT). As the switching losses in the proposed converter are too low, L and C size can be reduced by increasing the operating frequency. Also, all the semiconductor devices operate with soft switching. There is no additional voltage stress in the boost switch and diode. The proposed converter has a simple structure, low cost and ease of control as well. It has a simple control loop to achieve near unity power factor with the aid of the UC3854. In this study, detailed steady state analysis of the proposed converter is presented and this theoretical analysis is verified by a prototype of 100 kHz and 500 W converter. The measured power factor and efficiency are 0.99 and 97.9% at full load.