• 제목/요약/키워드: Active Scan

검색결과 135건 처리시간 0.024초

동상의 임상적 분석 (Clinical Analysis of Frostbite)

  • 최장규;김현철;신홍경
    • Journal of Trauma and Injury
    • /
    • 제28권3호
    • /
    • pp.158-169
    • /
    • 2015
  • Purpose: Frostbite can affect still soldiers. Initial clinical manifestations are similar for superficial and deep frostbite, so early treatment is identical. It is under-estimated by physicians. We try to identify the challenges of managing these complex tissue injuries. Methods: A retrospective analysis of 84 patients hospitalized at AFCH from 2009 to 2015 was conducted. We investigated differences of epidemiological characteristics, identification of soft tissue injury, treatment and complications between superficial (SF: 43; 51.2%) and deep (DF: 41; 48.8%) frostbite. Results: The major (94.0%) developed frostbite in dry circumstances (89.3%). Wet circumstances (66.7%) were more susceptible to DF rather than dry (46.7%). The 38 (45.2%) arrived to specialist within 7days. Most prone sites were feet, followed by hands. Toes had more deep injuries. DF presented more increased levels of ALT, CPK, CKMB, CRP. The bone scan of W+S+ was 48.3%, 87.1% and W+S- was 20.7%, 12.9%, respectively. The treatment resulted in improved or normalized perfusion scan with matching clinical improvement. It was a good tool to assess treatment response. Eighteen normal and 8 stenotic type of PCR resulted in normal with matching clinical improvement. One continuous obstructive waveform led to minor amputation. Twelve underwent both PCR and MRA. Among 6 normal PCR, 5 showed normal and one stenosis in MRA. All 5 stenosis and one obstruction showed the same findings in MRA. It was a good tool to evaluate vascular compromise. They were treated with rapid rewarming (11.6%, 22.0%), hydrotherapy (16.3%, 29.3%), respectively. Six (14.6%) underwent STSG, 2 (4.9%) had digital amputation in DF. Berasil, Ibuprofen, Trental were commonly administered. PGE1 was administered selectively for 6.8, 10.8 days, respectively. Raynaud's syndrome (16.3%), CRPS (4.7%), LOM (14.6%) and toe deformity (4.9%) were specific sequelae. Conclusion: We should recommend intensive foot care education, early rewarming and evacuation to specialized units. The bone scanning and PCR should allow for a more aggressive and active approach to the management of tissue viability.

  • PDF

경중족 절단 환자의 의족지 착용에 따른 족저압력 분포 특성 (Characteristics of Foot Pressure Distribution with or without Partial Prosthetic Foot in Transmetartarsal Amputee)

  • 성우성;양희승;성홍기;김학준
    • 대한족부족관절학회지
    • /
    • 제12권1호
    • /
    • pp.41-46
    • /
    • 2008
  • Purpose: This study was designed to evaluate characteristics of foot pressure distribution with or without partial prosthetic foot in transmetatarsal amputee. Materials and Methods: The subjects were 9 transmetatarsal amputees. Foot pressures were measured at hallux, the $1^{st}-5^{th}$ metatarsal head (MTH), mid-foot, condyle area by F-scan system in amputated or contralateral foot during active walking. Results: In amputated foot, mean peak pressure was greatest in midfoot without prosthetic foot but it was greatest in hindfoot with prosthetic foot. In unaffected foot, although mean peak pressure was higher in hallux, and $1-5^{th}$ MTH compared to amputated foot, it was greatest in hind foot both with and without prosthetic foot. However, in unaffected foot, mean peak pressure significantly decreased in hallux and $5^{th}$ MTH after wearing the prosthetic foot. There was a significant difference in mean peak pressure in hallux and $5^{th}$ MTH between amputated and unaffected foot after wearing prosthetic foot. However, other region had no significant difference with or without prosthetic foot between feet. Conclusions: The use of partial prosthetic foot tends to shift weight bearing from the heel area to forefoot and could significantly reduce hind foot peak pressure and redistributed to peak pressure. The partial prosthetic foot can also offer the peak pressure to reduction both amputated foot and unaffected foot and help to toe off during walking.

  • PDF

Analysis of Cross Sectional Ease Values for Fit Analysis from 3D Body Scan Data Taken in Working Positions

  • Nam, Jin-Hee;Branson, Donna H.;Ashdown, Susan P.;Cao, Huantian;Carnrite, Erica
    • International Journal of Human Ecology
    • /
    • 제12권1호
    • /
    • pp.87-99
    • /
    • 2011
  • Purpose- The purpose of this study was to compare the fit of two prototype liquid cooled vests using a 3D body scanner and accompanying software. The objectives of this study were to obtain quantitative measurements of ease values, and to use these data to evaluate the fit of two cooling vests in active positions and to develop methodological protocol to resolve alignment issues between the scans using software designed for the alignment of 3D objects. Design/methodology/approach- Garment treatments and body positions were two independent variables with three levels each. Quantitative dataset were dependent variables, and were manipulated in 3x3 factorial designs with repeated measures. Scan images from eight subjects were used and ease values were obtained to compare the fit. Two different types of analyses were conducted in order to compare the fit using t-test; those were radial mean distance value analysis and radial distance distribution rate analysis. Findings- Overall prototype II achieved a closer fit than prototype I with both analyses. These were consistent results with findings from a previous study that used a different approach for evaluation. Research limitations/implications- The main findings can be used as practical feedback for prototype modification/selection in the design process, making use of 3D body scanner as an evaluation tool. Originality/value- Methodological protocols that were devised to eliminate potential sources of errors can contribute to application of data from 3D body scanners.

Quantitative Measurements of 3-D Imaging with Computed Tomography using Human Skull Phantom

  • Kim, Dong-Wook;Kim, Hee-Joung;Haijo Jung;Soonil Hong;Yoo, Young-Il;Kim, Dong-Hyeon;Kim, Kee-Deog
    • 한국의학물리학회:학술대회논문집
    • /
    • 한국의학물리학회 2002년도 Proceedings
    • /
    • pp.506-508
    • /
    • 2002
  • As an advancement of medical imaging modalities and analyzing software with multi-function, active researches to acquire high contrast and high resolution image being done. In recently, development of medical imaging modalities like as Computed Tomography (CT) and Magnetic Resonance Imaging (MRI) is aiming to display anatomical structure more accuracy and faster. Thus, one of the important areas in CT today is the use of CT scanner for the quantitative evaluation of 3-D reconstruction images from 2-D tomographic images. In CT system, the effective slice thickness and the quality of 3-D reconstructed image will be influenced by imaging acquisition parameters (e.g. pitch and scan mode). In diagnosis and surgical planning, the accurate distance measurements of 3-D anatomical structures play an important role and the accuracy of distance measurements will depend on the acquisition parameters such as slice thickness, pitch, and scan mode. The skull phantom was scanned with SDCT for various acquisition parameters and acquisition slice thicknesses were 3 and 5 mm, and reconstruction intervals were 1, 2, and 3 mm to each pitch. 3-D visualizations and distance measurements were performed with PC based 3-D rendering and analyzing software. Results showed that the image quality and the measurement accuracy of 3-D SDCT images are independent to the reconstruction intervals and pitches.

  • PDF

3차원 바디 스캐너를 활용한 가상착의에 관한 인식 조사 - 업체 실무자 및 소비자를 대상으로 - (A Study of Applications of 3D Body Scanning Technology - Focused on Apparel Industry -)

  • 백경자;이정란;김미성
    • 한국생활과학회지
    • /
    • 제18권3호
    • /
    • pp.719-727
    • /
    • 2009
  • The ultimate success of commercial applications of body scan data in the apparel industry will be consumers' substantial applications such as automated custom fit, size prediction, virtual try-on, personal shopper services (Loker, S. et al., 2004). In this study, we surveyed fifty consumers and forty-seven apparel industry workers about their recognition and interest in 3D body scanning and virtual try-on. The results are as follows: 55% of the apparel industry workers has recognized 3D body scanning as a convenient technology, but do not know how to use it. To the questions regarding virtual try-on, 53% of the workers give positive answers. The consumers have a more positive view on virtual try-on than the workers do. The workers predict that the application of 3D body scan technology to the apparel industry could offer customers helpful information in their clothing selection by using virtual images of various size and style, and increase mass production of MTM(Made-To-Measure). The answers from the male consumers in their twenties indicate that virtual try-on is useful by 88% on offline shopping and by 100% on online shopping. 53% of the workers and 68% of the consumers gave answers that just by virtual try-on they could judge the quality of the apparel products and purchase them. Absolutely 3D virtual try-on is an effective tool for online shoppers. 85% of the workers anticipate applications of the 3D body scanning also in 'body measurement', 'custom pattern development' as well as 'virtual try-on' in the near future. With the positive reactions and the stimulating interests in virtual try-on, the conditions of contemporary world encourage more active researches and wide usages of the technology in apparel industry.

비정질 $MnO_2$ 전극의 전극두께에 따른 고출력 특성 변화 (High Power Characteristics of Amorphous $MnO_2$ Electrode by Variation of Electrode Thickness)

  • 성우경;김은실;이하영;김선욱
    • 전기화학회지
    • /
    • 제3권4호
    • /
    • pp.235-240
    • /
    • 2000
  • 고출력 전기화학 캐패시터를 위한 전극제조공정으로 screen printing과 doctor blade법이 연구되었다. Screen printing에 의해서 제작된 비정질 $MnO_2$전극으로 측정된 CV (cyclic voltammogram)는 이상적인 캐패시터에 가까운 특성을 보여주었다. 50mV/s의 scan rate에서의 CV로부터 계산된 비용량은 $140{\mu}m,\;24{\mu}m,\; 3{\mu}m$의 전극두께에 대해서 각각 5.8F/g과, 81.8F/g, 172.0F/g의 값을 나타내었다. Screen printing전극에서의 $MnO_2$활물질의 이용율을 $100\%$로 하였을 때, paste와 doctor blade법의 이용율은 각각 $3.4\%$$47.6\%$이었다. Screen printing은 고출력 응용을 위한 얇은 전극의 코팅 방법으로 우수한 특성을 보였다.

스캔 영상 기반의 밀리미터파(Ka 밴드) 복합모드 탐색기 표적인식 알고리즘 연구 (Target Recognition Algorithm Based on a Scanned Image on a Millimeter-Wave(Ka-Band) Multi-Mode Seeker)

  • 노경아;정준영;송성찬
    • 한국전자파학회논문지
    • /
    • 제30권2호
    • /
    • pp.177-180
    • /
    • 2019
  • 유도무기의 명중률 개선을 위해 해상 클러터 환경에서 표적을 정확하게 탐지하고 인식하는 연구가 다수 수행되고 있다. 해상 표적과 클러터의 신호가 다양하고 복잡한 특성을 보이기 때문에 능동 표적인식 기술에 대한 연구가 필수적으로 요구된다. 본 논문에서는 스캔 영상(scan image)으로 형성된 이미지에 프랙탈 차원기법(fractal dimension)인 FS(Fractal Signature) 분류기와 영상정합기법(scene matching)인 HRTI(High Resolution Target Image)을 적용하여 표적과 클러터를 구분하고 표적 간의 인식하는 알고리즘을 제안한다. 알고리즘을 적용한 시뮬레이션 수행 결과, HRTI 분류기는 표적1과 표적2를 모두 100 %, FS 분류기는 표적 1과 표적 2를 각 각 90 %, 93 % 이상 구분 및 인식한다.

Comparative clinical and radiologic evaluation between patients undergoing standard reversed shoulder arthroplasty or bony increased offset

  • Tiago Amorim-Barbosa;Ana Ribau;Helder Fonte;Luis Henrique Barros;Rui Claro
    • Clinics in Shoulder and Elbow
    • /
    • 제26권1호
    • /
    • pp.3-9
    • /
    • 2023
  • Background: Modifications of the medialized design of Grammont-type reverse shoulder arthroplasty (RSA) using a bony increased offset (BIO-RSA) has shown better clinical results and fewer complications. The aim of this study is to compare the clinical results, complications, and radiological outcomes between patients undergoing standard RSA and BIO-RSA. Methods: A retrospective review was performed of 42 RSA procedures (22 standard RSA and 20 BIO-RSA). With a minimum of 1 year of follow-up, range of motion (ROM), Constant shoulder score (CSS), visual analog scale (VAS), and subjective shoulder score (SSS) were compared. Radiographs and computed tomography (CT) scan were examined for scapular notching, glenoid and humeral fixation, and graft healing. Results: At a mean follow-up of 27.6 months (range, 12-48 months), a significant difference was found for active-internal rotation (P=0.038) and for passive-external rotation (P=0.013), with better results in BIO-RSA. No other differences were found in ROM, CSS (P=0.884), VAS score, and SSS. Graft healing and viability were verified in all patients with CT scan (n=34). The notching rate was 28% in the standard RSA group and 33% in the BIO-RSA group, but the standard RSA had more severe notching (grade 2) than BIO-RSA (P=0.039). No other significative differences were found in glenoid and humeral fixation. Conclusions: Bone-graft lateralization is associated with better internal and external rotation and with less severe scapular notching compared to the standard RSA. Integration of the bone graft occurs effectively, with no relevant changes observed on radiographic evaluation. Level of evidence: III.

Comparison of accuracy between free-hand and surgical guide implant placement among experienced and non-experienced dental implant practitioners: an in vitro study

  • Dler Raouf Hama;Bayad Jaza Mahmood
    • Journal of Periodontal and Implant Science
    • /
    • 제53권5호
    • /
    • pp.388-401
    • /
    • 2023
  • Purpose: This study investigated the accuracy of free-hand implant surgery performed by an experienced operator compared to static guided implant surgery performed by an inexperienced operator on an anterior maxillary dental model arch. Methods: A maxillary dental model with missing teeth (No. 11, 22, and 23) was used for this in vitro study. An intraoral scan was performed on the model, with the resulting digital impression exported as a stereolithography file. Next, a cone-beam computed tomography (CBCT) scan was performed, with the resulting image exported as a Digital Imaging and Communications in Medicine file. Both files were imported into the RealGUIDE 5.0 dental implant planning software. Active Bio implants were selected to place into the model. A single stereolithographic 3-dimensional surgical guide was printed for all cases. Ten clinicians, divided into 2 groups, placed a total of 60 implants in 20 acrylic resin maxillary models. Due to the small sample size, the Mann-Whitney test was used to analyze mean values in the 2 groups. Statistical analyses were performed using SAS version 9.4. Results: The accuracy of implant placement using a surgical guide was significantly higher than that of free-hand implantation. The mean difference between the planned and actual implant positions at the apex was 0.68 mm for the experienced group using the free-hand technique and 0.14 mm for the non-experienced group using the surgical guide technique (P=0.019). At the top of the implant, the mean difference was 1.04 mm for the experienced group using the free-hand technique and 0.52 mm for the non-experienced group using the surgical guide technique (P=0.044). Conclusions: The data from this study will provide valuable insights for future studies, since in vitro studies should be conducted extensively in advance of retrospective or prospective studies to avoid burdening patients unnecessarily.

리튬 2차전지용 $LiCoO_2$양극의 제조 및 특성 (Preparation and properties of $LiCoO_2$ cathode for Li rechargeable cell)

  • 문성인;정의덕;도칠훈;윤문수
    • E2M - 전기 전자와 첨단 소재
    • /
    • 제7권4호
    • /
    • pp.317-324
    • /
    • 1994
  • In this study, new preparation method of LiCoO$_{2}$ was applied to develop cathode active material for Li rechargeable cell, and followed by X-ray diffraction analysis, electrochemical properties and initial charge/discharge characteristics as function of current density. HC8A72- and CC9A24-LiCoO$_{2}$ were prepared by heating treatment of the mixture of LiOH H$_{2}$O/CoCO$_{3}$(1:1 mole ratio) and the mixture of Li$_{2}$CO$_{3}$/CoCO$_{3}$(1:2 mole ratio) at 850 and 900.deg. C, respectively. Two prepared LiCoO$_{2}$s were identified as same structure by X-ray diffraction analysis. a and c lattice constant were 2.816.angs. and 14.046.angs., respectively. The electrochemical potential of CFM-LiCoO$_{2}$(Cyprus Foote Mineral Co.'s product), HC8A72-LiCoO$_{2}$ and CC9A24 LiCoO$_{2}$ electrode were approximately between 3.32V and 3.42V vs. Li/Li reference electrode. Stable cycling behavior was obtained during the cyclic voltammetry of LiCoO$_{2}$ electrode. According as scan rate increases, cathodic capacity decreases, but redox coulombic efficiency was about 100% at potential range between 3.6V and 4.2V vs. Li/Li reference electrode. Cathodic capacity of HC8A72-LiCoO$_{2}$ was 32% higher than that of CFM-LiCoO$_{2}$ and that of CC9A24-LiCoO$_{2}$ was 47% lower than that of CFM-LiCoO$_{2}$ at 130th cycle in the condition of lmV/sec scan rate. Constant cur-rent charge/discharge characteristics of LiCoO$_{2}$/Li cell showed increasing Ah efficiency with initial charge/discharge cycle. Specific discharge capacities of CFM and HC8A72-LiCoO$_{2}$ cathode active materials were about 93mAh/g correspondent to 34% of theretical value, 110mAh/g correspondent to 40% of theretical value, respectively. In the view of reversibility, HC8A72-LiCoO$_{2}$ was also more excellent than CFM- and CC9A24-LiCoO$_{2}$.

  • PDF