• Title/Summary/Keyword: Active Power Control

Search Result 1,399, Processing Time 0.034 seconds

Development of An Active Magnetic Bearing-based Motor-Generator System (자기베어링 지지 모터-발전기 시스템 개발)

  • Kim, Jong-Moon;Kim, Choon-Kyung;Kim, Kook-Hun
    • Proceedings of the KIEE Conference
    • /
    • 1997.07a
    • /
    • pp.127-129
    • /
    • 1997
  • In this paper, an active magnetic bearing-based motor-generator(M-G) system is designed and controlled by using DSP devices. Several experiments including start-up test, impulse test, whirl test, and generator load test are conducted using digital PID algorithm and AC power of about 58Hz, 100V, 0.8A can be generated from the M-G set.

  • PDF

Control of Grid-Connected Power Conversion Systems using an Active NPC Inverter (Active NPC 인버터를 적용한 계통연계 전력변환 시스템의 제어)

  • Kim, Sung-Won;Seo, Dong-Woo;Lee, Kyo-Beum
    • Proceedings of the KIPE Conference
    • /
    • 2018.11a
    • /
    • pp.155-156
    • /
    • 2018
  • This paper presents a control method for grid-connected Active-NPC inverter systems. NPC (Neutral Point Clamped) is widely used in power conversion systems. NPC has a loss of switching elements and voltage imbalance. Active NPC has been proposed to overcome these drawbacks. ANPC changed the neutral diode to IGBT to reduce the switching loss. This paper modeled a grid-connected Acitve-NPC inverter systems and analyzed its performance. DSOGI PLL was used as a phase control method for precise control of grid link voltage. The proposed method is verified by PSIM simulation.

  • PDF

Phase Shift Control for Series Active Voltage Quality Regulators

  • Xiao, Guochun;Teng, Guofei;Chen, Beihai;Zhang, Jixu
    • Journal of Power Electronics
    • /
    • v.12 no.4
    • /
    • pp.664-676
    • /
    • 2012
  • A phase shift algorithm based on the closed-loop control of dc-link voltage implemented on a series active voltage quality regulator (AVQR) is proposed in this paper. To avoid pumping-up the dc-link voltage, a general phase shift compensation strategy is applied. The relationships among the operation variables are discussed in detail, which is very important for guiding the design of both the main circuit and the control system. Then on the basis of an investigation of the dc-link voltage pumping-up from viewpoint of the active power flow, a novel phase shift control method based on the closed-loop of the dc-link voltage is proposed. This method can adjust the phase of the output voltage gradually and automatically according to the dc-link voltage variation without introducing a phase jump. The effectiveness of the proposed strategy is verified through simulations of a single-phase 5kVA prototype and laboratory experiments on both a single-phase 5kVA and a three-phase 15kVA prototype.

Single Phase PWM Converters with Active Filter Functions Both on AC-Input and DC-Output Sides

  • MATSUI, Mikihiko;KITANO, Tatsuya
    • Proceedings of the KIPE Conference
    • /
    • 1998.10a
    • /
    • pp.258-263
    • /
    • 1998
  • A comparative study of single-phase PWM converters having active filtering functions both on ac-input and dc-output sides have been carried out. Based on the function of the dc-output side active filter, two types of configurations, the RPM (ripple power managing) type and the APM (average power managing) type are compared to show their contrastive characteristics. The prototype system using DSP based control algorithms, i.e. deadbeet current control and voltage sensor-less technique using full-order observer, show the availability of the proposed system.

  • PDF

A Study on a 3-phase Active Power Filter Under Unbalanced Input Voltage (불평형 전원시스템을 고려한 3상 능동전력 필터에 관한 연구)

  • 이승요;조준석;최규하;목형수;박영길;신우석
    • Proceedings of the KIPE Conference
    • /
    • 1997.07a
    • /
    • pp.233-238
    • /
    • 1997
  • An important assumption for the active power filter design using instantaneous power theory and the d-q transformation method in a 3-phase power system is based on balanced 3-phase system. However, under pratical conditions, the 3-phase power system can not be continuously balanced due to unbalanced loading. In this paper, a method to control the 3-phase active power filer using instantaneous power theory and the d-q transformation under unbalanced power system is presented and the theoretical results are verified by simulated results.

  • PDF

A Predictive control technique of Series Active Power Filter for Harmonic Reduction in Power System (전력 계통 시스템에서 고조파 저감을 위한 직렬형 능동 전력 필터의 예측형 제어 기법)

  • Kim, Myung-Bok;Moon, Gun-Woo;Youn, Myung-Joon
    • Proceedings of the KIEE Conference
    • /
    • 2001.10a
    • /
    • pp.187-191
    • /
    • 2001
  • A predictive control scheme, as a new control scheme, of series active power filter is presented and analyzed in this paper. It is composed of cascaded control scheme. Its validity is proved through simulations using PSIM.

  • PDF

A simplified method for the determination of the optimal operating patterns in system voltage-reactive power control (전압.무효전력제어에 있어서의 최적운전 목표상태의 간략결정법)

  • 송길영
    • 전기의세계
    • /
    • v.15 no.3
    • /
    • pp.1-7
    • /
    • 1966
  • The past several years have strongly anticipated the advent of a more integrated system control combining active power and voltage-reactive power controls. This paper presents a new approach to the intergrated system control with primary emphasis on the development of a new control method which combines the conventional economical load dispatching(ELD) and voltage-reactive power controls. The control method, in its fundamental principle, first determines the optimal active power allocation in accordance with the conventional ELD controller. By a proper manipulation of the remaining reactive power sources in the system, the control method then reduces the transmission losses of the system by the adjustment of system voltage distribution and also by the proper allotment of reactive power flows.

  • PDF

Active Voltage-balancing Control Methods for the Floating Capacitors and DC-link Capacitors of Five-level Active Neutral-Point-Clamped Converter

  • Li, Junjie;Jiang, Jianguo
    • Journal of Power Electronics
    • /
    • v.17 no.3
    • /
    • pp.653-663
    • /
    • 2017
  • Multilevel active neutral-point-clamped (ANPC) converter combines the advantages of three-level ANPC converter and multilevel flying capacitor (FC) converter. However, multilevel ANPC converter often suffers from capacitor voltage balancing problems. In order to solve the capacitor voltage balancing problems for five-level ANPC converter, phase-shifted pulse width modulation (PS-PWM) is used, which generally provides natural voltage balancing ability. However, the natural voltage balancing ability depends on the load conditions and converter parameters. In order to eliminate voltage deviations under steady-state and dynamic conditions, the active voltage-balancing control (AVBC) methods of floating capacitors and dc-link capacitors based on PS-PWM are proposed. First, the neutral-point current is regulated to balance the neutral-point voltage by injecting zero-sequence voltage. After that, the duty cycles of the redundant switch combinations are adjusted to balance the floating-capacitor voltages by introducing moderating variables for each of the phases. Finally, the effectiveness of the proposed AVBC methods is verified by experimental results.

Adaptive MR damper cable control system based on piezoelectric power harvesting

  • Guan, Xinchun;Huang, Yonghu;Li, Hui;Ou, Jinping
    • Smart Structures and Systems
    • /
    • v.10 no.1
    • /
    • pp.33-46
    • /
    • 2012
  • To reduce the vibration of cable-stayed bridges, conventional magnetorheological (MR) damper control system (CMRDS), with separate power supply, sensors and controllers, is widely investigated. In this paper, to improve the reliability and performance of the control system, one adaptive MR damper control system (AMRDS) consisting of MR damper and piezoelectric energy harvester (PEH) is proposed. According to piezoelectric effect, PEH can produce energy for powering MR damper. The energy is proportional to the product of the cable displacement and velocity. Due to the damping force changing with the energy, the new system can be adjustable to reduce the cable vibration. Compared with CMRDS, the new system is structurally simplified, replacing external sensor, power supply and controller with PEH. In the paper, taking the N26 cable of Shandong Binzhou Yellow River Bridge as example, the design method for the whole AMRDS is given, and simple formulas for PEH are derived. To verify the effectiveness of the proposed adaptive control system, the performance is compared with active control case and simple Bang-Bang semi-active control case. It is shown that AMRDS is better than simple Bang-Bang semi-active control case, and still needed to be improved in comparison with active control case.

DC Power Control for 3-Level Converter. (3-레벨 컨버터에 의한 직류전력제어)

  • 정연택;이사영;함년근
    • Proceedings of the KIPE Conference
    • /
    • 1996.06a
    • /
    • pp.126-129
    • /
    • 1996
  • This paper study on the control method of 3-level converter. The control of converter is composed of active power control for controlling a output voltage and of reactive power control for high power factor drives. And also, output central voltage is controlled by sensing a each condensor voltage of bank connected the part of dc.

  • PDF