• 제목/요약/키워드: Active Period

검색결과 1,583건 처리시간 0.028초

Formulating for efficacy

  • Johann W. Wiechers;Caroline L. Kelly;Trevor G. Blease;Chris Dederen
    • 대한화장품학회:학술대회논문집
    • /
    • 대한화장품학회 2003년도 IFSCC Conference Proceeding Book I
    • /
    • pp.457-468
    • /
    • 2003
  • Active ingredients have been around in cosmetics for a long time but have they really resulted in active cosmetic products\ulcorner In order to achieve this, the right active needs to be delivered to the right location at the right concentration for the correct period of time. And the extent (and therefore the concentration) of this delivery depends on the formulation. From a rather theoretical approach based on the polarity of the active ingredient, the stratum corneum and the oil phase, the Relative Polarity Index was established that enables the selection of a suitable emollient for ensuring skin penetration of the active ingredient. Practical examples subsequently show the validity of this approach that demonstrates that one can regulate the delivery of an active molecule (and therefore the efficacy of a cosmetic formulation) by selection and control of the emollient system. Cosmetic formulations are generally quite complex mixtures and subsequent experiments using different emulsifier systems indicated that this component of a cosmetic formulation could also have an impact on steering the active ingredient to the right layer of the skin, although it is too early to be able to derive general rules from this.

  • PDF

Experiment of an ABS-type control strategy for semi-active friction isolation systems

  • Lu, Lyan-Ywan;Lin, Ging-Long;Lin, Chen-Yu
    • Smart Structures and Systems
    • /
    • 제8권5호
    • /
    • pp.501-524
    • /
    • 2011
  • Recent studies have discovered that a conventional passive isolation system may suffer from an excessive isolator displacement when subjected to a near-fault earthquake that usually has a long-period velocity pulse waveform. Semi-active isolation using variable friction dampers (VFD), which requires a suitable control law, may provide a solution to this problem. To control the VFD in a semi-active isolation system more efficiently, this paper investigates experimentally the possible use of a control law whose control logic is similar to that of the anti-lock braking systems (ABS) widely used in the automobile industry. This ABS-type controller has the advantages of being simple and easily implemented, because it only requires the measurement of the isolation-layer velocity and does not require system modeling for gain design. Most importantly, it does not interfere with the isolation period, which usually decides the isolation efficiency. In order to verify its feasibility and effectiveness, the ABS-type controller was implemented on a variable-friction isolation system whose slip force is regulated by an embedded piezoelectric actuator, and a seismic simulation test was conducted for this isolation system. The experimental results demonstrate that, as compared to a passive isolation system with various levels of added damping, the semi-active isolation system using the ABS-type controller has the better overall performance when both the far-field and the near-fault earthquakes with different PGA levels are considered.

행인약침(杏仁藥鍼)이 항알레르기에 미치는 영향 (Study on the Anti-allergic Effect of Armeniacae Semen Herbal Acupuncture Solution)

  • 김유승;송춘호
    • Korean Journal of Acupuncture
    • /
    • 제24권4호
    • /
    • pp.151-162
    • /
    • 2007
  • Objectives : The purpose of this study was to examine the anti-allergic effect in vivo, and to observe single toxicity in mice of Armeniacae Semen herbal acupuncture solution (ASHA). Methods : We investigated anti DNP IgE-mediated passive cutaneous anaphylaxis in rodents and compound 48/80-induced active systemic anaphylatic shock in mice after treatment at both BL13 with ASHA of 25 ${\mu}{\ell}$(mice) or 50 ${\mu}{\ell}$(rats) 3 times for 5 days. To ascertain safety and toxicity of ASHA, we examined single toxicity test. In single test, three groups were treated with different dosages of ASHA (ASHA250, ASHA500 and ASHA1000) according to on Korean Food and Drug Administration, respectively. We observed attentively motality, abnormal clinical sign, body weight change, and organ weight of mice after ASHA treatment. Results : ASHA inhibited passive cutaneous anaphylaxis and active systemic anaphylatic shock by oral administration. During toxicity experiment period, there was no difference in body weight change, and organ weight among different dose groups. Death were not found in single test i.p. group. (ASHA250, ASHA500 and ASHA1000). Several individuals of single test i.p. group were observed yellow brown discharge around anus in early period after administration. Conclusions : These results indicate that ASHA have inhibition effects on passive cutaneous anaphylaxis and active systemic anaphylatic shock, and suggest that has some toxicity in high dosage.

  • PDF

Deadbeat Control with a Repetitive Predictor for Three-Level Active Power Filters

  • He, Yingjie;Liu, Jinjun;Tang, Jian;Wang, Zhaoan;Zou, Yunping
    • Journal of Power Electronics
    • /
    • 제11권4호
    • /
    • pp.583-590
    • /
    • 2011
  • Three-level NPC inverters have been put into practical use for years especially in high voltage high power grids. This paper researches three-level active power filters (APFs). In this paper a mathematical model in the d-q coordinates is presented for 3-phase 3-wire NPC APFs. The deadbeat control scheme is obtained by using state equations. Canceling the delay of one sampling period and providing the predictive value of the harmonic current is a key problem of the deadbeat control. Based on this deadbeat control, the predictive output current value is obtained by the state observer. The delay of one sampling period is remedied in this digital control system by the state observer. The predictive harmonic command current value is obtained by the repetitive predictor synchronously. The repetitive predictor can achieve a better prediction of the harmonic current with the same sampling frequency, thus improving the overall performance of the system. The experiment results indicate that the steady-state accuracy and the dynamic response are both satisfying when the proposed control scheme is implemented.

Development of a Dynamic Collision Avoidance Algorithm for Indoor Tracking System Based on Active RFID

  • Han, Se-Kyung;Choi, Yeon-Suk;Iwai, Masayuki;Sezaki, Kaoru
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • 제4권5호
    • /
    • pp.736-752
    • /
    • 2010
  • We propose a novel collision-avoidance algorithm for the active type RFID regarding an indoor tracking system. Several well-known collision avoidance algorithms are analyzed considering the adequacy for the indoor tracking system. We prove the superiority of the slotted ALOHA in comparison with CSMA for short and fixed length packets like an ID message in RFID. Observed results show that they are not applicable for active type RFID in terms of energy efficiency. Putting these all together, we propose a dedicated collision avoidance algorithm considering the unique features of the indoor tracking system. The proposed method includes a scheduled tag access period (STAP) as well as a random tag access period (RTAP) to address both of the static and dynamic characteristics of the system. The system parameters are determined through a quantitative analysis of the throughput and energy efficiency. Especially, some mathematical techniques have been deployed to obtain the optimal slot count for RTAP. Finally, simulation results are provided to illustrate the performance of the proposed method with variations of the parameters.

Robust Deadbeat Current Control Method for Three-Phase Voltage-Source Active Power Filter

  • Nishida, Katsumi;Ahmed, Tarek;Nakaoka, Mutsuo
    • Journal of Power Electronics
    • /
    • 제4권2호
    • /
    • pp.102-111
    • /
    • 2004
  • This paper is concerned with a deadbeat current control implementation of shunt-type three-phase active power filter (APF). Although the one-dimensional deadbeat control method can attain time-optimal response of APF compensating current, one sampling period is actually required fur its settling time. This delay is a serious drawback for this control technique. To cancel such a delay and one more delay caused by DSP execution time, the desired APF compensating current has to be predicted two sampling periods ahead. Therefore an adaptive predictor is adopted for the purpose of both predicting the control error of two sampling periods ahead and bringing the robustness to the deadbeat current control system. By adding the adaptive predictor output as an adjustment term to the reference value of half a source voltage period before, settling time is made short in a transient state. On the other hand, in a steady state, THD (total harmonic distortion) of the utility grid side AC source current can be reduced as much as possible, compared to the case that ideal identification of controlled system could be made.

Study on the Sulfide Corrosion to the Internal Surface of Transportation Pipeline

  • Zhang, Yiling;Qi, Ping;Kong, Dehong
    • Corrosion Science and Technology
    • /
    • 제7권4호
    • /
    • pp.193-196
    • /
    • 2008
  • This article briefly tests and analyzes the sulfur content and the distribution of active sulfur in the crude oil of Kurkow Kazakhstan and Siberian Russian, and discusses the relationship between active sulfur content and total sulfur content, active sulfur and corrosion. At the same time, it measures the open circuit potential of X70 steel and X60 steel witch have been immerged in the above two kind of crude oil for a period of time, discusses the sulfur corrosion to metal.

능동 블리더 회로를 적용한 조광기 호환용 LED 구동회로에 관한 연구 (A Study on LED Driver Compatible with Triac-dimmer Employing Active Bleeder)

  • 염봉호;홍성수;김택우
    • 전력전자학회논문지
    • /
    • 제19권4호
    • /
    • pp.297-302
    • /
    • 2014
  • In this paper, a LED driver compatible with TRIAC-dimmer applying active bleeder is proposed. If TRIAC-dimmer is connected with LED driver, flicker phenomenon occurs by TRIAC malfunction. In order to prevent this problem, a current over holding current must flow into TRIAC. Therefore, additional circuit compatible with TRIAC-dimmer is required to provide enough current. Passive bleeder has power loss in whole operation period. The proposed circuit apply a valley-fill circuit for power-factor-correction and a novel active bleeder detecting malfunction point of TRIAC. Therefore, it prevent malfunction of TRIAC-dimmer and have advantage of higher efficiency than passive bleeder. To verify the validity of proposed circuit, 13W-lighting LED driver prototype has been proposed.

Deadbeat Direct Active and Reactive Power Control of Three-phase PWM AC/DC Converters

  • Gandomkar, Ali;Seok, Jul-Ki
    • Journal of Power Electronics
    • /
    • 제18권6호
    • /
    • pp.1634-1641
    • /
    • 2018
  • This study focuses on a high-performance direct active and reactive power controller design that is successfully applicable to three-phase pulse width modulation (PWM) AC/DC converters used in renewable distributed energy generation systems. The proposed controller can overcome the sluggish transient dynamic response of conventional controllers to rapid power command changes. Desired active and reactive powers can be thoroughly obtained at the end of each PWM period through a deadbeat solution. The proposed controller achieves an exact nonlinear cross-coupling decoupling of system power without using a predefined switching table or bang/bang hysteresis control. A graphical and analytical analysis that naturally leads to a control voltage vector selection is provided to confirm the finding. The proposed control strategy is evaluated on a 3 kW PWM AC/DC converter in the simulation and experiment.

Bycatch Reduction by Experimental Shaking Codend Attached with Canvas in a Bottom Trawl

  • Kim, Yonghae
    • Fisheries and Aquatic Sciences
    • /
    • 제18권3호
    • /
    • pp.325-332
    • /
    • 2015
  • An active stimulating method for juvenile fishes to drive escaping from mesh of the codend was examined by shaking canvas in the bottom trawl followed by shrimp beam trawl. Field fishing trials by a bottom trawl were carried out between the Geomoondo and Jejudo in west of South sea, Korea by conver-net methods to examine the effect on the reduction of juvenile fish as a discard catch by generating a shaking movement of the codend using two pieces of asymmetrical semi-circular canvas. The mean period of the shaking motion with the round canvas was 10-15 s, and the range of amplitude as a vertical depth change was up to 0.4-0.6 m when towing speed 3.4-4.3 k't as estimated by peak event analysis. The escape rate of juvenile fish in conver-net by total juvenile bycatch (codend and cover-net) in 14 trials increased from 20% in a steady codend to 34% using a shaking codend in the bottom trawl, while the marketing catch or total bycatch was similar between steady and shaking cod ends. There was no difference in the body size of the fish and species composition between the steady and shaking cod ends. Above results demonstrate a new method for bycatch reduction actually up to 18% using an active stimulating device, although further experiments are needed to increase an effective shaking motion of the codend in amplitude and period for more bycatch reduction.