• Title/Summary/Keyword: Active Mixer

Search Result 69, Processing Time 0.029 seconds

Design of A Self Oscillating and Mixing Frequency Down-Converter Using A DGS (DGS 구조를 이용한 자기발진혼합형 주파수 하향변환기 설계)

  • 정명섭;박준석;김형석;임재봉
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.52 no.11
    • /
    • pp.536-543
    • /
    • 2003
  • In this paper, we describe a unique self oscillating and mixing (SOM) down-converter design using a modified defected ground structure (DGS). The proposed SOM converter is consisted of self-oscillator, which can produce negative resistance and select resonance frequency, RF matching circuit, and IF low pass filter. As the advantage of this SOM converter can mix LO and RF signals as well as inducing LO signal with only one active device. it is designed as a simple structure and the low cost. Also, there is easy advantage to be applied in RFIC/MMIC technology because it offers excellent phase noise performance in spite of using micro-strip structure. The LO signal for the proposed SOM converter is designed at 1㎓ and RF frequency was chosen to be 800MHz. The achieved conversion loss and phase noise performances of the implemented SOM converter are 15㏈ and -95dBc/Hz at 100KHz offset frequency respectively. The equivalent circuit parameters for DGS are extracted by using a three dimensional EM simulator and simple circuit analysis method.

A Retro-Directive Array System for Reduction of Electromagnetic Wave Reflection (전자기파 반사 감소를 위한 역지향 배열 안테나 시스템)

  • Ha, Jungje;Jang, Sunghoon;Lee, Yongshik
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.26 no.1
    • /
    • pp.113-118
    • /
    • 2015
  • In this paper, a cancellation technique for electromagnetic waves is realized based on a retrodirective antenna array system. The system re-transmits a signal to the direction of the incoming signal, with the same frequency and opposite phase. For the experimental verification, a $2{\times}2$ retrodirective array system is designed and fabricated. Experimental results for a metallic cylinder show as much as 26-dB reduction in reflection.

Design Considerations of K-band Front-End Module for Dynamic Range (Dynamic Range를 고려한 K-band Front-End Module 설계)

  • Han, Geon-Hee;Jang, Youn-Gil;Rhee, Young-Chul
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.7 no.1
    • /
    • pp.15-20
    • /
    • 2012
  • In this paper, we designed and analysed K-band front-end module for digital microwave communication system receiver which improvement of dynamic range. We also suggested method of minimum amplified input signal level used to minimize noise figure of low-noise amplifier for High dynamic range. The designed modules consist of active mixer with conversions gain and PL-DRO with high stability and quality factor. The designed modules performance is that has the characteristics of over 54dB conversion gain, 1.3dB noise figure.

Exposure Assessment of Apple Orchard Workers to the Insecticide Imidacloprid Using Whole Body Dosimetry During Mixing/Loading and Application (전신복장법을 이용한 농약 조제 및 살포 과정 중 살충제 Imidacloprid에 대한 사과 과수원 농작업자의 노출 평가)

  • Lee, Jae Yun;Noh, Hyun Ho;Park, Hyo Kyoung;Jeong, Hye Rim;Jin, Me Jee;Park, Kyung-Hun;Kim, Jeong-Han;Kyung, Kee Sung
    • The Korean Journal of Pesticide Science
    • /
    • v.20 no.3
    • /
    • pp.271-279
    • /
    • 2016
  • To evaluate exposure characteristics of the insecticide imidacloprid to apple orchard workers during treatment on orchard fields and evaluate its potential risk using a whole body dosimetry (WBD) method, 1,000-time diluted acephate+imidacloprid 25(20+5)% solutions were sprayed on 10 apple orchard fields in Cheongju with a speed sprayer at a rate of 3,000 L/ha/person, after put on clothes such as inner/outer clothes, personal air pump with a IOM sampler, nitrile glove and mask. Exposure test included mixing, loading and application steps. The test pesticide imidacloprid residues in the collected samples were analyzed with a HPLC-DAD. Recoveries ranged from 81.5 to 108.6% for analytical method validation and from 73.8 to 86.7% for field recovery. Total exposed amounts to mixer/loader and applicator were found to be 0.0014-0.0279% of total applied active ingredient of imidacloprid. Glove exposure of both mixer/loader and applicator was higher than the other parts. Margins of safety of mixer/loader and applicator were calculated to be 97-355 and 46-196, respectively, indicating that exposure risk of imidacloprid to apple orchard workers by spraying with a speed sprayer was very low.

Development of RF IC, Signal Processing IC and Software for Portable GPS Receiver (휴대 GPS 수신기용 RF IC, 신호처리 IC 및 소프트웨어 개발)

  • Ryum, Byung R.;Koo, Kyung Heon;Song, Ho Jun;Jee, Gyu In
    • Journal of Advanced Navigation Technology
    • /
    • v.1 no.1
    • /
    • pp.23-34
    • /
    • 1997
  • A multi-channel digital GPS receiver has been developed including a RF-to-IF engine (engine 1), a digital signal processing engine (engine 2) with a microprocessor interfacing, and a navigation software. A high speed SiGe heterojunction bipolar transistor (HBT) as a active device has been mounted on chip-on-board (COB) type hybrid ICs such as LNA, mixer, and VCO in RF front-end of the engine 1 board. A 6-channel digital correlator together with a real-time clock and a microprocessor interface has been realized using an Altera Flex 10K FPGA as well as ASIC technology. Navigation software controlling the correlator for GPS signal tracking, retrieval and storing a message retrieval, and position calculation has been implemented. The GPS receiver was tested using a single channel STR2770 simulator. Successful navigation message retrieval and position determination was confirmed.

  • PDF

Real-Time Respiration and Heartbeat Detector Using a Compact 1.6 GHz Single-Channel Doppler Sensor (소형화된 1.6 GHz 단일 채널 도플러 센서를 이용한 실시간 호흡 및 심장 박동 감지기)

  • Lee, Hyun-Woo;Park, Il-Ho;Kim, Dong-Wook
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.18 no.4 s.119
    • /
    • pp.379-388
    • /
    • 2007
  • This paper presents a real-time respiration and heartbeat detector comprised of a 1.6 GHz single-channel Doppler sensor and analog/digital signal processing block for remote vital sign detection. The RF front end of the Doppler sensor consists of an oscillator, mixer, low noise amplifier, branch-line hybrid and patch antenna. We apply artificial transmission lines(ATLs) to the branch-line hybrid, which leads to a size reduction of 40 % in the hybrid, while its performance is very comparable to that of a conventional hybrid. The analog signal conditioning block is implemented using second order Sallen-Key active filters and the digital signal processing block is realized with a LabVIEW program on a computer. The respiration and heartbeat detection is demonstrated at a distance of 50 cm using the developed system.

A Study on RF Receiver Design and Analysis of Digital Radar Receiver (디지털 레이더 수신기의 RF-수신단 설계 및 분석)

  • Lim, Eun-Jae;Hwang, Hee-Geun;Rhee, Young-Chul
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.25 no.3
    • /
    • pp.282-288
    • /
    • 2014
  • In this paper, we have analyzed and designed a digital RF receiver based on the optimization of the dynamic range parameter to secure the wideband characteristics and linearity of digital radar receivers. To improve the wideband characteristics and dynamic range, a low noise amplifier is matching design with a noise source to minimize the noise figure in 1 GHz bandwidth and we improved the linearity of RF-receiver by securing the conversion gain characteristics of receiver through the design of active mixer. RF receiver is designed to give gain 63 dB, noise figure 1.2 dB and dynamic range of RF receiver has 75.8 dB in a wide band of 8.8~9.8 GHz. It is shown to be applicable to X-band digital radar receiver.

Miniaturized DBS Downconverter MMIC Showing a Low Noise and Low Power Dissipation Characteristic (저잡음ㆍ저소비전력 특성을 가지는 위성방송 수신용 초소형 다운컨버터 MMIC)

  • Yun, Young
    • Journal of Navigation and Port Research
    • /
    • v.27 no.4
    • /
    • pp.443-447
    • /
    • 2003
  • In this work. using 0.2 GaAs modulation doped FET(MODFET), a high performance DBS downconverter MMIC was developed for direct broadcasting satellite (DBS) application. Without LNA, the downconverter MMIC showed a very low noise of 4.8 dB, which is lower by 3 dB than conventional ones. A low LO power of -10 dBm was required for the normal DBS operation of the downconverter MMIC. which reduced the power consumption via a removal of LO amplifier on MMIC. It required only a low power consumption of 175 mW, which is lower than 70 percent of conventional ones. The LO leakage power at IF output was suppressed to a lower level than 30 dBm, which removes a bulky LO rejection filter on a board. The fabricated chip, which include a mixer, If amplifiers. LO rejection filter, and active balun, exhibited a small size of $0.84{\times}0.9\textrm{mm}^2$.

Risk Assessment of Agricultural Worker's Exposure to Fungicide Thiophanate-methyl during Treatment in Green Pepper, Cucumber and Apple Fields (고추, 오이 및 사과 재배 중 살균제 Thiophanate-methyl 살포 시 농작업자의 노출 및 위해 평가)

  • Choi, Hoon;Kim, Jeong-Han
    • Journal of Applied Biological Chemistry
    • /
    • v.57 no.1
    • /
    • pp.73-81
    • /
    • 2014
  • The present study was carried out to assess exposure and risk to thiophanate-methyl wettable powder for agricultural worker during mixing/loading and application with power sprayer in green pepper, cucumber and apple fields. Dermal exposure was measured with patches, gloves, socks and masks, while inhalation exposure was evaluated with personal air pump and solid sorbent. Those methods were full validated before experiment. During mixing/loading, dermal exposure amount in green pepper, cucumber and apple fields was $24.0{\pm}6.7$, $4.5{\pm}1.5$ and $18.5{\pm}0.6mg$, corresponding to mean 0.007, 0.001 and 0.005% of prepared active ingredient, respectively. The major exposed part for mixer/loader was hands (78-92%). Dermal exposure amount for applicator in green pepper, cucumber and apple fields was $84.9{\pm}14.0$, $34.0{\pm}20.8$ and $30.7{\pm}9.1mg$, corresponding to mean 0.024, 0.016 and 0.013% of applied active ingredient, respectively. The main body parts of exposure in apple field were hands, while thighs and shins in other fields. Inhalation exposure amount in green pepper, cucumber and apple fields was $1.5{\pm}2.2$, $52.7{\pm}48.9$ and $4.0{\pm}4.9{\mu}g$ during mixing/loading and $0.2{\pm}0.1$, $23.2{\pm}12.4$ and $0.4{\pm}0.6{\mu}g$ for applicator, respectively. These results were suggested that main factors affecting dermal exposure were contact frequency to the plants, foliage density, hygienic behavior, work type, and working environment, while inhalation exposure was affected mainly by working environment, especially wind. In risk assessment, margin of safety for thiophanate-methyl in all cases was over 1. However, during application in green pepper field, margin of safety was close to 1.