• Title/Summary/Keyword: Active Intensity

Search Result 434, Processing Time 0.027 seconds

Constrained rotary MR damper design and its application (자기 유변 유체를 이용한 각도 제한 회전 감쇠기 설계 및 응용)

  • 김상화;박영진
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1997.10a
    • /
    • pp.191-194
    • /
    • 1997
  • Passive, semi-active and active dampers have been used to dissipate energy in mechanical systems. Semi-active dampers have higher performance than passive dampers and require lower power to operate than active dampers. Its damping characteristics can be changed appropriately for varying conditions. In this paper, we developed a semi-active damper based on Magnetorheological(MR) fluid. MR fluid has a variable damping characteristics proportional for the magnetic field intensity. It has several advantages such as high strength, low viscosity, robustness in impurities and wide temperature range of operational stability. We designed a constrained rotary MR damper base on valve mode which can dissipate more energy per unit volume. The system with Bingham characteristics is obtained and proved by the experiment.

  • PDF

Optimum Design of Dye-Sensitized Solar Module for Building-Integrated Photovoltaic Systems

  • Lee, Kyu-Seok;Kang, Man Gu
    • ETRI Journal
    • /
    • v.39 no.6
    • /
    • pp.859-865
    • /
    • 2017
  • This paper presents a method for determining the optimum active-area width (OAW) of solar cells in a module architecture. The current density-voltage curve of a reference cell with a narrow active-area width is used to reproduce the current density profile in the test cell whose active area width is to be optimized. We obtained self-consistent current density and electric potential profiles from iterative calculations of both properties, considering the distributed resistance of the contact layers. Further, we determined the OAW that yields the maximum efficiency by calculating efficiency as a function of the active-area width. The proposed method can be applied to the design of the active area of a dye-sensitized solar cell in Z-type series connection modules for indoor and building-integrated photovoltaic systems. Our calculations predicted that OAW increases as the sheet resistances of the contact layers and the intensity of light decrease.

Wide Dynamic Range CMOS Image Sensor with Adjustable Sensitivity Using Cascode MOSFET and Inverter

  • Seong, Donghyun;Choi, Byoung-Soo;Kim, Sang-Hwan;Lee, Jimin;Shin, Jang-Kyoo
    • Journal of Sensor Science and Technology
    • /
    • v.27 no.3
    • /
    • pp.160-164
    • /
    • 2018
  • In this paper, a wide dynamic range complementary metal-oxide-semiconductor (CMOS) image sensor with the adjustable sensitivity by using cascode metal-oxide-semiconductor field-effect transistor (MOSFET) and inverter is proposed. The characteristics of the CMOS image sensor were analyzed through experimental results. The proposed active pixel sensor consists of eight transistors operated under various light intensity conditions. The cascode MOSFET is operated as the constant current source. The current generated from the cascode MOSFET varies with the light intensity. The proposed CMOS image sensor has wide dynamic range under the high illumination owing to logarithmic response to the light intensity. In the proposed active pixel sensor, a CMOS inverter is added. The role of the CMOS inverter is to determine either the conventional mode or the wide dynamic range mode. The cascode MOSFET let the current flow the current if the CMOS inverter is turned on. The number of pixels is $140(H){\times}180(V)$ and the CMOS image sensor architecture is composed of a pixel array, multiplexer (MUX), shift registers, and biasing circuits. The sensor was fabricated using $0.35{\mu}m$ 2-poly 4-metal CMOS standard process.

Correlation Between Physical Activity Measured by a Wearable Device and Quality of Life in Older Adults

  • Kim, Si-hyun
    • Physical Therapy Korea
    • /
    • v.28 no.4
    • /
    • pp.251-255
    • /
    • 2021
  • Background: Physical activity and quality of life (QOL) influence the health status of older adults. Recently, the use of wearable devices to monitor physical activity has increased. Objects: This study examined the relationship between the amount of physical activity, measured using a wearable device, and QOL among older adults. Methods: In total, 71 older adults (aged ≥ 65 years) were enrolled. The amount of physical activity was measured using a wearable device with a wrist strap, and daily physical activity was classified according to intensity (sedentary, light, moderate, or very active). Self-reported QOL was evaluated using the Short Form 36 (SF-36) questionnaire. Pearson and Spearman correlation analyses were conducted to analyze parametric and non-parametric variables, respectively. The relationship between amount of daily physical activity and SF-36 scores was assessed. Results: The correlation analyses revealed positive correlations between the amount of moderate-intensity and very active physical activity (minutes/day) and SF-36 scores (p < 0.05). Conclusion: Physical activity of at least moderate intensity is associated with better QOL in older adults. Further studies are required to verify the effects of increased physical activity on QOL in older adults.

A Multi-photodiode Array-based Retinal Implant IC with On/off Stimulation Strategy to Improve Spatial Resolution

  • Park, Jeong Hoan;Shim, Shinyong;Jeong, Joonsoo;Kim, Sung June
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • v.17 no.1
    • /
    • pp.35-41
    • /
    • 2017
  • We propose a novel multi-photodiode array (MPDA) based retinal implant IC with on/off stimulation strategy for a visual prosthesis with improved spatial resolution. An active pixel sensor combined with a comparator enables generation of biphasic current pulses when light intensity meets a threshold condition. The threshold is tuned by changing the discharging time of the active pixel sensor for various light intensity environments. A prototype of the 30-channel retinal implant IC was fabricated with a unit pixel area of $0.021mm^2$, and the stimulus level up to $354{\mu}A$ was measured with the threshold ranging from 400 lx to 13120 lx.

The Biopharmaceutical Studies on the Some Compunding Drugs( III ) -Antipyritic Analgesic Effect on the Aminopyrine Combined with Atropine Sulfate by Writhing Method- (배합약물(配合藥物)의 생물약제학적(生物藥劑學的) 연구(硏究) ( III ) -Aminopyrine의 해열진통작용(解熱鎭通作用)에 미치는 Atropine Sulfate의 배합효과(配合效果))

  • Park, Young-Ock;Chung, Ki-Hwa;Kim, Jae-Wan
    • Journal of Pharmaceutical Investigation
    • /
    • v.4 no.1_2
    • /
    • pp.19-24
    • /
    • 1974
  • The comparative studies were made on the analgesic antipyretic effects of aminopyrine used individually and combined with parasympathetic agents (atropine sulfate). The analgesic antipyretic effects were eximined by Writhing's method to the experimental groups(mouse), and the following effects were found : 1) The active intensity of aminopyrine by it's oral administration combined with atropine sulfate is as follows. Amiinopyrine 80 mg/kg combided with Atropine sulfate 0.005 mg/kg=Aminopyrine 100 mg/kg 2) The most active range of intensity of Atropine sulfate(adjuvant) by it's oral administration is as follows. Atropine sulfate $0.004{\sim}0.005\;mg/kg$.

  • PDF

Exothermic processes in nitric acid solutions imitating highly active raffinate

  • E.V. Belova;V.V. Kalistratova;A.S. Obedkov
    • Nuclear Engineering and Technology
    • /
    • v.55 no.10
    • /
    • pp.3808-3814
    • /
    • 2023
  • The thermal stability of nitric acid solutions after contact with non-irradiated and irradiated tributyl phosphate (TBP) and its solution in Isopar-M has been studied. It has been established that exothermic processes occur during heating due to the interaction of soluble radiolysis products and the decomposition of the extractant with nitric acid. Such processes can occur at temperatures below 100 ℃, but unlike a thermal explosion that occurs in seconds, they are longer in time and are accompanied by weak heat evolution. Their intensity depends on the composition of the extractant, the concentration of HNO3, and the volume ratio of the organic and aqueous phases. The presence of extractant degradation products in raffinates does not pose a risk of a rapid evolution of gaseous products during evaporation, however, the presence of reducing agents can significantly increase the intensity of the exothermic decomposition of raffinates.

Linear-logarithmic Active Pixel Sensor with Photogate for Wide Dynamic Range CMOS Image Sensor

  • Bae, Myunghan;Jo, Sung-Hyun;Choi, Byoung-Soo;Choi, Pyung;Shin, Jang-Kyoo
    • Journal of Sensor Science and Technology
    • /
    • v.24 no.2
    • /
    • pp.79-82
    • /
    • 2015
  • This paper proposes a novel complementary metal oxide semiconductor (CMOS) active pixel sensor (APS) and presents its performance characteristics. The proposed APS exhibits a linear-logarithmic response, which is simulated using a standard $0.35-{\mu}m$ CMOS process. To maintain high sensitivity and improve the dynamic range (DR) of the proposed APS at low and high-intensity light, respectively, two additional nMOSFETs are integrated into the structure of the proposed APS, along with a photogate. The applied photogate voltage reduces the sensitivity of the proposed APS in the linear response regime. Thus, the conversion gain of the proposed APS changes from high to low owing to the addition of the capacitance of the photogate to that of the sensing node. Under high-intensity light, the integrated MOSFETs serve as voltage-light dependent active loads and are responsible for logarithmic compression. The DR of the proposed APS can be improved on the basis of the logarithmic response. Furthermore, the reference voltages enable the tuning of the sensitivity of the photodetector, as well as the DR of the APS.

Active Shape Model-based Object Tracking using Depth Sensor (깊이 센서를 이용한 능동형태모델 기반의 객체 추적 방법)

  • Jung, Hun Jo;Lee, Dong Eun
    • Journal of Korea Society of Digital Industry and Information Management
    • /
    • v.9 no.1
    • /
    • pp.141-150
    • /
    • 2013
  • This study proposes technology using Active Shape Model to track the object separating it by depth-sensors. Unlike the common visual camera, the depth-sensor is not affected by the intensity of illumination, and therefore a more robust object can be extracted. The proposed algorithm removes the horizontal component from the information of the initial depth map and separates the object using the vertical component. In addition, it is also a more efficient morphology, and labeling to perform image correction and object extraction. By applying Active Shape Model to the information of an extracted object, it can track the object more robustly. Active Shape Model has a robust feature-to-object occlusion phenomenon. In comparison to visual camera-based object tracking algorithms, the proposed technology, using the existing depth of the sensor, is more efficient and robust at object tracking. Experimental results, show that the proposed ASM-based algorithm using depth sensor can robustly track objects in real-time.