• 제목/요약/키워드: Active & reactive power

검색결과 460건 처리시간 0.031초

직병렬 임피던스 보상을 통한 계통 연계 분산전원 인버터의 PCC 무효전력 제어 알고리즘 (Reactive Power Control Algorithm of Grid-Connected Inverter at the Point of Common Coupling With Compensation of Series and Parallel Impedances)

  • 허철영;송승호;김용래
    • 전력전자학회논문지
    • /
    • 제27권2호
    • /
    • pp.92-99
    • /
    • 2022
  • Due to space and geographical constraints, the power source may be located outside the island area, resulting in the considerable length of transmission line. In these cases, when an active power is transmitted, unexpected reactive power is generated at a point of common coupling (PCC). Unlike the power transmitted from the power generation source, the reactive power adversely affects the system. This study proposes a new algorithm that controls reactive power at PCC. Causes of reactive power errors are separated into parallel and series components, which allows the algorithm to compensate the reactive current of the inverter output and control reactive power at the PCC through calculations from the impedance, voltage, and current. The proposed algorithm has economic advantages by controlling the reactive power with the inverter of the power source itself, and can flexibly control power against voltage and output variations. Through the simulation, the algorithm was verified by implementing a power source of 3 [kVA] capacity connected to the low voltage system and of 5 [MVA] capacity connected to the extra-high voltage system. Furthermore, a power source of 3 [kVA] capacity inverter is configured and connected to a mock grid, then confirmed through experiments.

능동전력필터를 위한 확장된 전류 동기 검출법 (The Expanded Current Synchronous Detection for Active Power Filters)

  • 정영국;김우용;임영철
    • 전력전자학회논문지
    • /
    • 제6권4호
    • /
    • pp.341-347
    • /
    • 2001
  • 전류 동기 검출법은 3상이 불평형된 전원 시스템 하에서도 전원전류를 평형된 정현파로 보상해 줄 뿐 만 아니라 순시전력이론에 비해서 단상에도 적용가능한 이론이다. 그러나 종전의 전류 동기 검출법은 능동전력필터가 고조파 성분과 기본파 무효성분을 독립 제어하는 하이브리드형 능동전력필터 시스템 등에는 적용하기 곤란하다. 따라서 본 연구에서는 불평형 전원 시스템 하에서도 비선형 부하전류를 유효성분, 기본파 무효성분 그리고 왜형성분으로 분해하여 독립제어 가능한 확장된 전류 동기 검출법을 제시하였다. 본 연구에서 제시한 방법의 타당성을 입증하기 위해, 불평형 교류 전원 하에서 평균전력이론, 동기 전류 검출법 그리고 제안된 방법을 실험에 의하여 비교검토하였다.

  • PDF

전압형 능동필터에 의한 교류고조파제거와 무효전력보상 (AC harmonic elimination and reactive power compensation by voltage-type active filter)

  • 김한성;최규하;신우석;이제필
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 1988년도 한국자동제어학술회의논문집(국내학술편); 한국전력공사연수원, 서울; 21-22 Oct. 1988
    • /
    • pp.688-692
    • /
    • 1988
  • The active filter system for harmonic current compensation is presented in this paper. The active filter, composed of a three-phase voltage-type PWM inverter and the capacitor, compensates both the harmonic currents and the reactive power by injecting the PWM current to the ac line. This paper describes the principle of harmonic current compensation, the calculation circuits for the harmonic currents to be injected, the several compensation characteristics. Also the experimental results are shown to verify the theory proposed in this paper.

  • PDF

FUNDAMENTAL RESEARCH OF A NOVEL 3/1 PHASE CONVERTER FOR ELECTRIFIED RAILROAD

  • Farshad, Siamak;Rongtai, Hao
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 1998년도 Proceedings ICPE 98 1998 International Conference on Power Electronics
    • /
    • pp.955-960
    • /
    • 1998
  • Electrified railroads inject large amount of harmonics, negative sequence and reactive currents to electric supply systems. This paper introduces application of active filter as a 3/1 phase converter for electrified railroad. In this system active filter compensate harmonics, negative sequence and reactive currents and electric railroad and active filter together act as a balance three-phase load with power factor 1

  • PDF

계통 연계형 태양광 발전 시스템의 부하 무효전력 보상이 적용된 단독운전 인지법 (The Anti-Islanding Method with Compensation of Load Reactive Power for Grid-connected Photovoltaic Generation System)

  • 정진범;신동현;김희준
    • 전기학회논문지
    • /
    • 제57권1호
    • /
    • pp.58-64
    • /
    • 2008
  • In this paper, we present an active anti-islanding method with a load monitoring system using reactive power control. The proposed method, which is based on reactive power control, has fewer harmonics components than those in conventional methods, and it can minimize the reactive power component of the grid because it compensates the reactive power component with the load monitoring. The proposed quick islanding detection method was confirmed from the experimental results with an inverter for a 3kW photovoltaic system.

전력조류추적법을 이용한 무효전력요금 책정방법의 개선 (The Improvement of Calculating Reactive Power Tariffs by Using Power Flow Tracing)

  • 박성철;노경수
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2001년도 하계학술대회 논문집 A
    • /
    • pp.533-535
    • /
    • 2001
  • This paper proposes a methodology to compute the servicing price of reactive power in electrical power market of competitive environment. The result of proposed method is proved by a 6-bus sample test system. In this paper we propose the real-time pricing method assigning to variable charges, the downstream power flow tracing assigning to fixed charges. The reactive power will be active by the proposed method through competitive electrical power market.

  • PDF

DVR을 이용한 전력품질 개선 (Power Quality Improvement using DVR)

  • 김성환
    • 전기전자학회논문지
    • /
    • 제25권3호
    • /
    • pp.462-466
    • /
    • 2021
  • DVR은 배전선로의 전압 변동을 보상하는 장치로 일반적으로 계통의 무효전력 보상, 역률개선 문제를 해결하는 장치와 결합하여 사용된다. 이러한 결합보상기기는 상대적으로 제어가 어렵고 부피가 커지는 단점을 갖는다. 본 논문에서는 DVR의 전력위상제어(Power Angle Contorl)방법을 적용하여 부가적인 보상기기의 결합이 없이 DVR 단독으로 배전선로의 무효전력과 전압변동을 동시에 보상하기 위해 보상 전압의 최대 크기와, 위상, 보상 가능한 무효전력 및 유효전력에 대한 수학적 해석을 수행하였다. 유효전력을 배터리에 충전하고 전압 변동시 저장된 에너지를 공급하기 위한 제어알고리즘을 개발하고 Matlab 시뮬레이션을 통해 결과를 확인하였다.

계통 연계형 인버터의 무효전력 공급을 고려한 Stack 설계 (The Stack Design Considering The Reactive Power Supply of Grid-Connected Inverter)

  • 고광수;오필경;김희중;김영민
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2016년도 전력전자학술대회 논문집
    • /
    • pp.453-454
    • /
    • 2016
  • The ESS(Energy Storage System) connected with distributed generation is drawing attention due to improving the quality load leveling, peak shaving for enhancing reliability of the power grid. The grid-connected inverter makes frequency adjustment to the active power's charge discharge according to the load variation. In addition, the inverter is possible to act as a reactive power compensation device to eliminate harmonic operates as power factor change inhibiting, anti-transient voltage fluctuation, active filter. In this paper, we propose a design method of igbt stack considering the reactive power supply capacity to improve the quality and reliability of the inverter. Moreover, the grid-connected inverter considering the four-quadrant rated operation designed stack and verified the feasibility of the design through a thermal analysis.

  • PDF

발전기 무효전력 성능시험 절차 개발 (Development of Generator Reactive Capability Test Method in Generation Stations)

  • 신만수;정태원
    • 전기학회논문지
    • /
    • 제60권5호
    • /
    • pp.936-941
    • /
    • 2011
  • Generation cooperations have focused on active power directly related to economic value. So, utility cooperation have taken expense to stabilize power system, although generator has responded quickly with variation of power system voltage and is controlled at real time. As a reactive power source, it is necessary for generator's capabilities to be verified. But domestic generators scarcely have been tested and operated to reactive power capability. In case of power system fault, operators would not quickly take a follow-up actions about reactive power disturbance. Therefore generator reactive power capability verification strategy must be developed, several generators is tested as examples since 2004. This paper is extracted from the test results.

능동 전력 필터의 새로운 제어 방법 (A New Control Strategy of The Active Power Filter)

  • 유완식;김남정;조규민;인치각
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2000년도 하계학술대회 논문집 B
    • /
    • pp.1174-1176
    • /
    • 2000
  • This paper presents a new control strategy of the active power filter to compensate the fundamental and high order reactive power. Using the proposed control strategy, the calculation of active and reactive power of the load is not required. So the system configurations and the controller can be constructed very simply. To decrease the load of active power filter, the LC passive filter bank can be used without any additional strategy. In this paper, the algorithm of the proposed new control strategy is discussed and the experimental results are shown.

  • PDF