• Title/Summary/Keyword: Activated energy

Search Result 987, Processing Time 0.03 seconds

Gas and particle removal characteristics of a novel electrostatic precipitation type air cleaner using an activated carbon filter as an electrode (활성탄 섬유 필터를 전극으로 활용한 정전 방식의 공기정화장치의 가스 및 입자 제거 특성 분석)

  • Lim, Gi-Taek;Kim, Yong-Jin;Han, Bangwoo;Woo, Chang Gyu;Shin, Weon Gyu;Kim, Hak-Joon
    • Particle and aerosol research
    • /
    • v.14 no.1
    • /
    • pp.9-16
    • /
    • 2018
  • We have developed an electrostatic precipitation (ESP) type air cleaner for indoor air quality and investigated its performances regarding CADR (Clean air delivery rate), single-pass efficiency and gas removal efficiency. The ESP air cleaner used an ACF (Activated carbon fiber) filter for gas removal and the ACF as a high voltage electrode for particle removal. The ESP air cleaner was tested in a chamber with the volume of $1m^3$ regarding CADR and gas removal efficiency. The applied CADR area of the ESP was $1.8m^2$. Gas removal efficiency was tested with 3 gases (Acetaldehyde, Acetic acid, Ammonia). As the results of the gas removal efficiency, the ESP air cleaner shows the removal efficiencies of 90, 98 and 85% for acetaldehyde, acetic acid and ammonia, respectively.

Operating Mode of Thermally Activated Building System (TABS) for Residential Buildings According to their Cooling Load Profile (주거건물의 냉방 부하 패턴에 따른 구체축열시스템 운전 방안)

  • Park, Sang-Hoon;Yeo, Myoung-Souk;Yoo, Mi-Hye;Lee, Yu-Ji;Chung, Woong-June;Kim, Kwang-Woo
    • Journal of the Korean housing association
    • /
    • v.23 no.2
    • /
    • pp.99-106
    • /
    • 2012
  • Compared to Packaged Terminal Air Conditioning Systems, Radiant Cooling Systems have the advantage of energy saving and thermal comfort. Thermally Activated Building System (TABS) is one of the radiant heating and cooling systems. The main difference between TABS and other radiant systems lies in the usage of the time-lag effect of storing heat energy in the concrete. Current energy usage in summer time is concentrated within a specific time by using Packaged Terminal Air-Conditioner (PTAC). Due to the time-lag effect of TABS, energy usage can be distributed to other time zones. To maximize this effect, it is important to determine the appropriate operating mode, which for TABS is dependent upon the cooling load generated by the occupancy schedule. In this study, occupancy schedules are determined for various residential types. The operating modes of TABS for these residential types are estimated by using a dynamic computational simulation method. The results indicate that the operating modes of TABS can be determined by residential type and occupancy schedule. The load handled ratio by TABS is set up differently according to the cooling load profile obtained from residential type and occupancy schedule. By using TABS, energy consumption could be reduced by 20% compared to PTAC.

Specific Capacitance Characteristics of Electric Double Layer Capacitors with Phenol Based Activated Carbon Fiber Electrodes and Organic Electrolytes (페놀계 활성탄소섬유 전극과 유기성 전해질을 사용하는 전기이중층 캐패시터의 비축전용량 특성)

  • An, Kay Hyeok;Kim, Jong Huy;Shin, Kyung Hee;Noh, Kun Ae;Kim, Tae Hwan
    • Applied Chemistry for Engineering
    • /
    • v.10 no.6
    • /
    • pp.822-827
    • /
    • 1999
  • The specific capacitance characteristics which were of the electric double layer capacitors(ELDC) made of phenol based activated carbon fiber(ACF) electrodes and organic electrolytes has been investigated with respect to different specific surface area of electrodes and different kinds of organic electrolytes. Throughout charge-discharge cell tests, it has been found that larger surface area and larger pore diameter of electrodes contribute to increase the specific capacitance. Binary mixture of organic solvent with propylene cabonate(PC) and tetrahydrofuran(THF) for 1 M-$LiClO_4$ electrolyte has a higher specific capacitance than single solvent of PC or mixed solvent with PC and diethyl cabonate(DEC). Also, even though 1 M-tetraethylamonium perchlorate(TEAPC) of organic electrolyte shows higher specific capacitance, it has longer charge time because of its lower ion mobility.

  • PDF

Ultrasonic and Alkaline Pre-treatments of Waste Activated Sludge for Enhancing Anaerobic Digestion (혐기성 소화를 위한 폐활성슬러지의 초음파와 알칼리 전처리)

  • Park, In Geun;Son, Han Hyung;Lee, Chae Young
    • Journal of the Korea Organic Resources Recycling Association
    • /
    • v.26 no.2
    • /
    • pp.53-63
    • /
    • 2018
  • The hydrolysis of organic solid waste, such as sludge, is the rate-limiting step of the anaerobic digestion. The longer rate-limiting step lead to decrease of treatment efficiency and increase hydraulic retention time and anaerobic digester. Therefore, the pre-treatment has been applied for accelerating the hydrolysis step. This study was investigated the effects of pre-treatment of waste activated sludge using ultrasonic and alkaline integrated treatment simultaneously. The results showed the cumulative methane production and the methane production rate increased while the lag phase decreased. Therefore ultrasonic and alkaline integrated pre-treatment of waste activated sludge resulted in acceleration of hydrolysis step in anaerobic digestion.

Adsorption and Desorption Characteristics of Binary-component Volatile Organic compounds (Toluene-MEK) on Activated Carbon (이성분 휘발성유기화합물(Toluene-MEK)의 활성탄 흡착 및 탈착 특성)

  • Yu, Seon A;Cho, Jong Hoon;Park, Ji Yun;Rhee, Young Woo
    • Clean Technology
    • /
    • v.23 no.4
    • /
    • pp.421-428
    • /
    • 2017
  • In this study, we have investigated the characteristics of adsorption and desorption of toluene, methyl ethyl ketone (MEK) and their binary component using activated carbon. The BET analysis was performed to identify the characteristics of the activated carbon, and the desorption characteristics with temperature were examined to find out an optimum desorption temperature. Ten cyclic experiments of adsorption-desorption were performed, where each adsorption temperature was maintained at room temperature and desorption temperature at upto $120^{\circ}C$. In case of single component cyclic test, the efficiencies of adsorption and desorption decreased as the cycle increased. MEK which has lower affinity with activated carbon than toluene showed lower efficiencies of adsorption and desorption. In case of binary component cyclic test, a typical roll-up phenomenon was observed during adsorption process, where MEK reaches at breakpoint first and then was swept out by toluene.

Thoracic Irradiation Recruit M2 Macrophage into the Lung, Leading to Pneumonitis and Pulmonary Fibrosis

  • Park, Hae-Ran;Jo, Sung-Kee;Jung, Uhee
    • Journal of Radiation Protection and Research
    • /
    • v.42 no.4
    • /
    • pp.177-188
    • /
    • 2017
  • Background: Radiation-induced pneumonitis and pulmonary fibrosis are common dose-limiting complications in patients receiving radiotherapy for lung, breast, and lymphoid cancers. In this study, we investigated the characteristics of effective immune cells related to pneumonitis and fibrosis after irradiation. Materials and Methods: After anesthesia, the whole thorax of C57BL/6 mice was irradiated at 14 Gy. The lung tissue and bronchoalveolar lavage fluid were collected at defined time points post-irradiation for the determination of histological and immunohistochemical analysis and inflammatory cell population infiltrated into the lung. Results and Discussion: Whole thoracic irradiation increased the deposition of extracellular matrix (ECM), lung weight, and pleural effusions, which started to die from 4 months later. At 4 months after irradiation, the numbers of macrophages and lymphocytes as well as neutrophils were increased dramatically in the lung. Interestingly, the macrophages that were recruited into the lung after irradiation had an enlarged foamy morphology. In addition, the expressions of chemokines (CCL-2, CCL-3, CXCL-10) for the attraction of macrophages and T cells were higher in the lung of irradiated mice. The high expressions of these chemokines were sustained up to 6 months following irradiation. In thoracic irradiated mice, infiltrated macrophages into the lung had the high levels of Mac-3 antigens on their surface and upregulated the hallmarks of alternatively activated macrophages such as arginase-1 and CD206. Furthermore, the levels of IL-4 and IL-13 were higher in a BAL fluid of irradiated mice. Conclusion: All results show that thoracic irradiation induces to infiltrate various inflammation-related immune cells, especially alternatively activated macrophages, through enhancing the expression of chemokines, suggesting that alternatively activated macrophages are most likely important for leading to pulmonary fibrosis.

Adsorption of heavy metal ions onto a surface treated with granular activated carbon and activated carbon fibers (표면 처리에 따른 입상활성탄 및 활성탄소섬유의 중금속 흡착)

  • Kang, Kwang Cheol;Kwon, Soo Han;Kim, Seung Soo;Choi, Jong Won;Chun, Kwan Sik
    • Analytical Science and Technology
    • /
    • v.19 no.4
    • /
    • pp.285-289
    • /
    • 2006
  • In this study, the effect of an acidic treatment on granular activated carbon (GAC) and activated carbon fibers (ACF) was investigated for a $Pb^{2+}$ and $Ni^{2+}$ ion adsorption. 1.0 M nitric acid solution was used as the acid solution for the surface treatment. Surface properties of the GAC and ACF were characterized by the pH, elemental analysis and pHpzc (pH of the point of zero charge). Their specific surface area and the pore structure were also evaluated by the nitrogen adsorption data at 77K. As a result, the acidic treatment led to an increase of the oxygen-containing functional groups. Furthermore, the adsorption capacity of the acid-treated GAC and ACF was improved in the order of acidic-ACF > untreated-ACF > acidic-GAC > untreated-GAC, though the decrease in specific surface area induced by a pore blocking of the functional groups was observed.

Novel anti-obesity effects of alpha-lipoic acid mediated by suppression of hypothalamic AMP-activated protein kinase

  • Lee, Ki-Up
    • Proceedings of the Korean Society of Applied Pharmacology
    • /
    • 2003.11a
    • /
    • pp.3-4
    • /
    • 2003
  • Body weight is maintained at a relatively constant level over days and months despite variability in food intake and physical activity. To achieve energy homeostasis, the hypothalamus receives information related to energy surplus or shortage from the periphery and controls food intake and energy expenditure. Leptin, an adipocyte derived hormone, is a principal mediator that signals the brain about the stored energy status. Increased leptin signaling in the brain prevents excess energy stores by suppressing food intake and increasing energy expenditure. In addition, insulin and nutrients themselves, such as glucose and free fatty acids, also regulate food intake.

  • PDF

Comparative Study on Adsorptive Characteristics of Diazinon in Water by Various Adsorbents

  • Ryoo, Keon Sang;Jung, Sun Young;Sim, Hun;Choi, Jong-Ha
    • Bulletin of the Korean Chemical Society
    • /
    • v.34 no.9
    • /
    • pp.2753-2759
    • /
    • 2013
  • The aim of the present study is to explore the possibility of utilizing fly ash and loess, as alternative to activated carbon, for the adsorption of diazinon in water. Batch adsorption experiment was performed to evaluate the influences of various factors like initial concentration, contact time and temperature on the adsorption of diazinon. The adsorption data shows that fly ash is not effective for the adsorption of diazinon. The equilibrium data for both activated carbon and loess were fitted well to the Freundlich isotherm model. The pseudo-second-order kinetic model appeared to be the better-fitting model because it has higher $R^2$ compared to the pseudo-first-order kinetic model. The thermodynamic parameters such as free energy (${\Delta}G$), the enthalpy (${\Delta}H$) and the entropy (${\Delta}S$) were calculated. Contrary to loess, the ${\Delta}G$ values of activated carbon were negative at the studied temperatures. It indicates that the adsorption of diazinon by activated carbon is a favorable and spontaneous process. The positive ${\Delta}H$ values of activated carbon and loess suggest that the diazinon adsorption process is endothermic in nature. In addition, the positive ${\Delta}S$ values show that increased randomness occurs at the solid/solution surface during the adsorption of diazinon.