• Title/Summary/Keyword: Activated Carbon(AC)

Search Result 214, Processing Time 0.02 seconds

Removal Characteristics of Phenol at Advanced Oxidation Process with Ozone/Activated Carbon Impregnated Metals (오존/촉매 산화공정에서 금속담지 활성탄을 이용한 페놀의 분해 특성)

  • Choi, Jae Won;Yoon, Ji Young;Park, Jin Do;Lee, Hak Sung
    • Applied Chemistry for Engineering
    • /
    • v.23 no.3
    • /
    • pp.302-307
    • /
    • 2012
  • Advanced oxidation processes (AOP) such as O3/activated carbon process and O3/catalysts process were used to compare the decomposition of phenol. Catalysts such as Pd/activated carbon (Pd/AC), Mn/activated carbon (Mn/AC), Co/activated carbon (Co/AC) and Fe/activated carbon (Fe/AC) were prepared by impregnation of Pd, Mn, Co and Fe into the activated carbon of pellet form, respectively. Based on an hour of reactions, the following descending order for the decomposition ratios of dissolved O3 to the 1.48 mg/L of saturated dissolved O3 was observed: Mn/AC (45%) > Pd/AC (42%) > Co/AC (33%) > AC (31%) > Fe/AC (27%). The removal efficiencies of phenol were also arranged in the descending order of AOP as follows: Mn/AC (89%) > Pd/AC (85%) > Co/AC (77%) > AC (76%) > Fe/AC (71%). The remaining ratios (C/Co) of TOC (total organic carbon) after an hour of experiments were arranged in the ascending order of AOP as follows : Pd/AC (0.29) < Mn/AC (0.36) < AC (0.40) < Co/AC (0.49) < Fe/AC (0.51). However, the catalytic effects in the Co/AC and the Fe/AC processes were little in comparison with O3/AC process. The maximum concentrations of intermediates such as hydroquinone and catechol formed from the decomposition of phenol were arranged in the ascending order of AOP as follows: Pd/AC < Fe/AC < Co/AC < AC < Mn/AC. In the case of Pd/AC process, these intermediates were almost disappeared after an one hour of reaction.

Effect of Two-step Surface Modification of Activated Carbon on the Adsorption Characteristics of Metal Ions in Wastewater I. Equilibrium and Batch Adsorptions

  • Park, Geun-Il;Lee, Jae-Kwang;Ryu, Seung-Kon;Kim, Joon-Hyung
    • Carbon letters
    • /
    • v.3 no.4
    • /
    • pp.219-225
    • /
    • 2002
  • The two-step surface modifications of activated carbon was carried out to improve the adsorption capacity of toxic heavy metal ions in liquid phase. Physical and chemical properties of the as-received activated carbon (AC) and two kinds of surface-modified activated carbons ($1^{st}AC$ and $2^{nd}AC$) were evaluated through the BET analysis, surface acidity, and oxides measurements. Specific surface area and pore volume did not significantly change, but surface oxide-group remarkably increased by the surface modification. Equilibrium and batch adsorptions of the various metals, such as Pb, Cd, and Cr, using AC, $1^{st}AC$, and $2^{nd}AC$ were performed at initial pH 5. The adsorption capacity and rate of $2^{nd}AC$ were higher than those of AC and $1^{st}AC$. The carboxylic/sodium carboxylate complex groups were developed from the two-step surface modification of activated carbon, which strongly affected the adsorption of metal ions.

  • PDF

Selective Removal of Cr (VI) and Cr (III) in Aqueous Solution by Surface Modified Activated Carbon

  • Lee, Jeong-Min;Kim, Min-Il;Lee, Young-Seak
    • Carbon letters
    • /
    • v.9 no.1
    • /
    • pp.23-27
    • /
    • 2008
  • The adsorption and reduction of Cr (VI) to Cr (III) by surface modified activated carbon (AC) in an aqueous solution was studied. The effects of surface modifications on the properties of the carbons were investigated by the analysis of specific surface area, carbon surface pH, acid/base surface values and functional groups. In order to understand the Cr(VI) adsorption and reduction ratio from Cr(VI) to Cr(III), the Cr adsorption capacity of AC was also measured and discussed by using inductively coupled plasma and UV spectrophotometer. The modifications bring about substantial variation in the chemical properties whereas the physical properties such as specific surface area, pore volume and pore size distribution nearly were not changed. Total Cr adsorption efficiency of as-received activated carbon (R-AC) and nitric acid treated activated carbon (N1-AC and N2-AC) were recorded on 98.2, 99.7 and 100%. Cr(III) reduction efficiency of R-AC increased largely from 0.4% to 28.3% compared to N1-AC and N2-AC.

Adsorption Efficiency of Coal Based GACs and Evaluation of Economic Efficiency (석탄계 활성탄별 흡착능 및 경제성 평가)

  • Choi, Dong-Hoon;Son, Hee-Jong;Park, Jin-Sik;Moon, Choo-Yeun;Ryu, Dong-Choon;Jang, Seong-Ho;Kwon, Ki-Won;Kim, Han-Soo
    • Journal of Environmental Science International
    • /
    • v.22 no.2
    • /
    • pp.205-213
    • /
    • 2013
  • This is made of domestic and foreign coal activated carbon of five species, physicochemical adsorption efficient about sterilize products and micro harmful substances and is a result of the economic evaluation. The most well-developed micropores bed volume 123,409 of AC-1 activate carbon appeared to be the best next AC-2, AC-3, AC-4, AC-5 followed by activated carbon was investigated. PFOA and PFOS in the BV 96,000 when evaluating foreign types of adsorption activated carbon adsorption capacity was greater when more than PFOA, PFOS showed that the adsorption well. The economic evaluation of activated carbon usage in chloroform (CUR) was most excellent as a AC-1 4.3 g/day, the next AC-2, AC-3, AC-4, AC-5 there are two types of foreign economic order appears to have appeared, but the current domestic market when applying the price AC-1, AC-3, AC-2, AC-4, AC-5 order was investigated.

Nitrogen and Fluorine Co-doped Activated Carbon for Supercapacitors

  • Kim, Juyeon;Chun, Jinyoung;Kim, Sang-Gil;Ahn, Hyojun;Roh, Kwang Chul
    • Journal of Electrochemical Science and Technology
    • /
    • v.8 no.4
    • /
    • pp.338-343
    • /
    • 2017
  • Activated carbon has lower electrical conductivity and reliability than other carbonaceous materials because of the oxygen functional groups that form during the activation process. This problem can be overcome by doping the material with heteroatoms to reduce the number of oxygen functional groups. In the present study, N, F co-doped activated carbon (AC-NF) was successfully prepared by a microwave-assisted hydrothermal method, utilizing commercial activated carbon (AC-R) as the precursor and ammonium tetrafluoroborate as the single source for the co-doping of N and F. AC-NF showed improved electrical conductivity ($3.8\;S\;cm^{-1}$) with N and F contents of 0.6 and 0.1 at%, respectively. The introduction of N and F improved the performance of the pertinent supercapacitor: AC-NF exhibited an improved rate capability at current densities of $0.5-50mA\;cm^{-2}$. The rate capability was higher compared to that of raw activated carbon because N and F codoping increased the electrical conductivity of AC-NF. The developed method for the co-doping of N and F using a single source is cost-effective and yields AC-NF with excellent electrochemical properties; thus, it has promising applications in the commercialization of energy storage devices.

Antibacterial Characteristics of Silver Nano-Particles Attached to Activated Carbon Filter (은나노를 부착한 활성탄 필터의 제균특성)

  • Heo, Ju-Yeong;Nam, Sang-Yeob;Kang, Jeong-Hee;Song, Ji-Hyeon;Kang, Byung-Ha;Han, Sung
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.21 no.10
    • /
    • pp.583-589
    • /
    • 2009
  • Activated carbon has long been used in purification processes for indoor air quality. However, the bioaerosol removal by activated carbon is not often sufficient to be used in an air control devise. In order to overcome these problems, silver nano-particles have been proposed as an antibacterial agent on the surface of activated carbon. Silver or silver ions have been known for antimicrobial activities. In this study, bioaerosol generated by using an Escherichia coli culture was introduced to a lab-scale column packed with activated carbon (AC) and silver nano-particles attached to activated carbon (Ag-AC). E. coli was almost completely removed in the Ag-AC column, whereas bioaerosol penetrated through the AC column. To determine the antibacterial effect of different filter materials in a full-scale air-handling system, another experiment was conducted using a wind tunnel equipped with a heat exchanger and three filter materials including commercial fabric, AC and Ag-AC. It was found that E. coli proliferated on the surface of the heat exchanger after 5 days, which dramatically increased bioaerosol counts in the effluent air stream. The fabric filter could not control the increased bioaerosol and most of the E. coli penetrated the filter. The bacterial removal efficiency was found to be approximately 45% in the AC filter, while the antibacterial efficiency increased to 70% using the Ag-AC filter. Consequently, the Ag-AC filter can be an effective method to control bioaerosol and improve indoor air quality.

Effect of Activated Carbon on Growth of Ginger (Zingiber officinale)

  • Choi Seong-Kyu;Park Young-Tae
    • Plant Resources
    • /
    • v.8 no.1
    • /
    • pp.44-47
    • /
    • 2005
  • Activated carbon(AC) can be utilized as a soil conditioner in agricultural crop areas. This study was conducted to investigate the effect of AC on growth and yield of Ginger(Zingiber officinale) as affected by different amounts of AC. The results obtained are summarized as follows. Growth characteristics including plant height and leaf length were the highest when activated carbon added with $5-10\%$, suggesting that optimum amount of activated carbon was ranged from 5 to $15\%$. Growth and enlargement of the root were improved by $10\%$ AC with higher rhizome length and weight.

  • PDF

Leaf and Stem Production of Angelica acutiloba by Activated Carbon in Green House

  • Choi Seong-Kyu;Park Young-Tae
    • Plant Resources
    • /
    • v.8 no.1
    • /
    • pp.71-74
    • /
    • 2005
  • Activated carbon(AC) can be utilized as a soil conditioner in agricultural crop areas. This study was conducted to investigate the effect of AC on Leaf and Stem Production of Angelica acutiloba as affected by different amounts of AC. The results obtained are summarized as follows. Growth characteristics including plant height and leaf length were the highest when activated carbon added with 10, suggesting that optimum amount of activated carbon was ranged from 10 to $20\%$. Growth and enlargement of the root were improved by $10\%$ AC.

  • PDF

Effect of Two-step Surface Modification of Activated Carbon on the Adsorption Characteristics of Metal Ions in Wastewater II. Dynamic Adsorption

  • Lee, Jae-Kwang;Park, Geun-Il;Ryu, Seung-Kon;Ki, Joon-Hyung
    • Carbon letters
    • /
    • v.4 no.1
    • /
    • pp.14-20
    • /
    • 2003
  • Based on the previous results of the equilibrium and batch adsorptions, the removal efficiency of the two-step surface-modified activated carbon ($2^{nd}AC$) for heavy metal ions such as Pb, Cd, and Cr in fixed column was evaluated by comparing with that of the as-received activated carbon (AC) and the first surface-modified activated carbon ($1^{st}AC$). The order of metal removal efficiency was found as $2^{nd}AC$ > $1^{st}AC$ $\gg$ AC, and the efficiency of the $2^{nd}AC$ maintained over 98% from the each metal solution. Increase of the removal efficiency by the second surface modification was contributed to maintain favorable pH condition of bulk solution during adsorption process. The removal of the heavy metals on the $2^{nd}AC$ was selective with Pb being removed in preference to Cr and Cd in multicomponent solutions and slightly influenced by phenol as the organic material.

  • PDF

Comparison of Surface Characteristics and Adsorption Characteristics of Activated Carbons Changed by Acid and Base Modification (산과 염기의 개질에 의해 변화된 활성탄의 표면특성과 흡착특성 비교)

  • Lee, Song-Woo;Lee, Min-Gyu;Park, Sang-Bo
    • Journal of Environmental Science International
    • /
    • v.17 no.5
    • /
    • pp.565-571
    • /
    • 2008
  • The surface properties of activated carbon modified by acids and base were studied. The influence of the surface chemistry on the adsorption of benzene and acetone vapor on modified activated carbons has been investigated The modified activated carbons were obtained by treatment with acetic acid ($CH_3COOH$), nitric acid ($HNO_3$) and sodium hydroxide (NaOH). The modified activated carbons had similar porosity but different surface chemistry and adsorption characteristics. The total surface acidity (sum of functional groups) of activated carbon (AC-AN) treated by nitric acid was 2.6 times larger than that of activated carbon (AC) before the acid treatment. Especially, carboxyl group was much developed by nitric acid treatment. The benzene equilibrium adsorption capacity of AC-AN decreased 20% more than that of AC. However, the acetone equilibrium adsorption capacity of AC-AN increased 20% more than that of AC because of the large increase of carboxyl group and acidity.