• 제목/요약/키워드: Acrylic resin system

검색결과 73건 처리시간 0.032초

Strain gauge를 사용한 임플랜트 인상법의 정확도 비교 (A COMPARATIVE ANALYSIS OF THE ACCURACY OF IMPLANT IMPRESSION TECHNIQUES BY USING STRAIN GAUGE)

  • 한인택;김영수;김창회
    • 대한치과보철학회지
    • /
    • 제33권3호
    • /
    • pp.539-549
    • /
    • 1995
  • The purpose of this study was to determine the accuracy of 3 implant impression methods by using strain gauge. The models used for this study were partially edentulous mandibular acrylic resin casts Model A, with two abutment analogs in #46,47 extraction site, represented two implant parallel to to the adjacent natural tooth. Model B represent an anterior implant parallel to the adjacene natural tooth and a posterior implant exhibiting a 15-degree lingual inclination. Master framework were fabricated on the master model, and 3 strain gauges were attached to a master framwork to determine the passivity of fit of the framework to sample casts made by the three impression techniques. The master framework was attached to each sample cast with gold screws, which were tightened with the torque driver to ensure a consistent toque application of 10 Ncm. Universal Digital Measuring System UCAM-5BT was used for strain measuring. Impression techniques studid were : 1. unsplinted tapered impression coping, polyvinyl siloxane, stock tray 2. unsplinted squared impression coping, polyether, custom tray 3. squared impression coping splinted with Duralay resin, polyether, custom tray Through analysis on data from this study, the following conclusions were obtained. 1. There were no statistically significant differences between the mean strain recorded from the sample casts made with the tree impression. But only strain values of model A(parallel group) Y-axis was signifcantly differed between Technique 1 and 3(P<0.05). 2. There was no statistically significant difference between model A(parallel group) and model B(15-degree divergent group).

  • PDF

인공 다공질체를 이용한 석조문화재 강화제의 처리효과 (Effect of Consolidation using Artificial Porous Material for Stone Cultural Property)

  • 이재만;이명성;김재환;이미혜
    • 보존과학회지
    • /
    • 제26권3호
    • /
    • pp.325-334
    • /
    • 2010
  • 이 연구에서는 석조문화재 강화제의 처리 효과를 정량적으로 규명하기 위해 화강석분과 포틀랜드시멘트를 이용하여 강도가 낮은 인공 다공질 시료를 제작하고, 여기에 4종의 알콕시실란계 강화제와 아크릴수지, 에폭시수지 등 상업화 된 6종의 강화제를 적용하여 처리 전과 후의 특성을 비교 분석하였다. 실험 결과, Silres BS OH 100은 밀도 및 표면 경도 향상에 효과적이며, 발수성의 SS-101과 친수성의 Site SX-RO는 염풍화에 대해 향상된 내구성을 보였다. Araldite 2020은 물리적 기능 향상에 가장 효과적이나, Syton HT-50 및 Paraloid B72는 낮은 침투율로 인해 표면 일부에 처리효과가 집중되어 전체적으로는 풍화에 취약한 것으로 나타났다.

복합 레진으로 수복된 세 가지 첨와형태 와동의 파절 저항성에 관한 연구 (FRACTURE RESISTANCE OF THE THREE TYPES OF UNDERMINED CAVITY FILLED WITH COMPOSITE RESIN)

  • 최훈수;신동훈
    • 대한치과보존학회:학술대회논문집
    • /
    • 대한치과보존학회 2008년도 Spring Scientific Meeting(the 129th) of Korean Academy if Conservative Dentistry
    • /
    • pp.177-183
    • /
    • 2008
  • 심미성 복합레진은 자연 치질을 보존시키며 나아가 잔존 치질의 강도를 강화시켜 준다. 복합레진 수복시 더 많은 치질을 남기기 위해 첨와 (undercut) 형태의 교합면 치질을 남긴 채 복합레진으로 수복하는 경우가 많으나, 어느 정도 강도가 복원되는지에 대해서는 잘 알려져 있지 않다. 이에 본 연구에서는 첨와 형태의 와동을 잔존치질의 두께 (법랑질 /법랑질과 상아질)에 따라 형성하고 복합레진으로 충전한 경우, 수복된 치아의 파절 저항성을 손상이 없는 자연치와 비교 평가하였다. 상악 대구치 40개의 교합면을 편평하게 삭제한 후 방사선 사진에서 치수각의 위치를 확인하였다. 대상 치아를 각 10개씩 4개군으로 분류하였으며, $1{\sim}3$군은 실험군으로 모두 협측에 깊이 7 mm, 근원심 폭경 5 mm의 첨와 형태 와동을 형성하였고, 와동저에서 치수각까지의 거리를 약 0.5 mm로 유지하였으며 교합면쪽의 치질 두께를 달리하였다. 1군은 법랑질과 소량의 상아질로 구성된 치질 두께를 1 mm, 2군은 법랑질과 상아질의 두께를 1.5 mm, 3군은 법랑질과 상아질의 두께를 2 mm가 되도록 하였고, 4군은 건전한 자연치를 와동형성 없이 대조군으로 사용하였다. 두께 측정은 방사선 사진을 스캔한 후 길이 확대 프로그램을 이용하였다. 각 와동을 37% 인산으로 산부식한 다음 단일병 접착제 Single $Bond^{TM}$ (3M/ESPE, USA)를 적용하였고 혼합형 복합레진 Filtek $Z-250^{TM}$ (3M/ESPE, USA)을 사용하여 적층 충전하였다. 치아를 실온에서 증류수에 24시간 동안 보관한 다음 Sof-Lex system (3M/ESPE, USA)을 사용하여 연마하였다. 이후 자가중합형 레진에 교합면을 기저부에 평행한 상태로 치근부를 매몰한 다음 Universal testing machine (Zwick Z010, Germany)에서 지름 3 mm의 staineless steel rod를 1 mm/min의 cross-head speed로 하중을 가하여 파절 강도를 측정하였다. 통계 분석은 95% 유의 수준의 One-way ANOVA와 Tukey test를 이용하였으며 다음과 같은 결과를 얻었다. 1. 와동 형성 후 복합레진을 수복한 군들은 대조군에 비해 약 75%의 파절 강도를 보였다. 2. 교합면쪽 잔존 치질의 두께에 따른 파절 저항은 유의한 차이를 보이지 않았다 (p > 0.05). 복합레진을 이용하여 첨와 형태의 와동을 수복한 후 파절 강도를 측정한 결과 건전 치아보다는 강도가 낮았지만, 상부의 잔존 치질이 대부분 법랑질로 이루어진 경우에도 복합 레진으로 수복하면 건전 치아 파절 강도의 75%까지 유지할 수 있다는 결론을 얻었다.

  • PDF

복합 레진으로 수복된 세 가지 첨와형태 와동의 파절 저항성에 관한 연구 (FRACTURE RESISTANCE OF THE THREE TYPES OF UNDERMINED CAVITY FILLED WITH COMPOSITE RESIN)

  • 최훈수;신동훈
    • Restorative Dentistry and Endodontics
    • /
    • 제33권3호
    • /
    • pp.177-183
    • /
    • 2008
  • 심미성 복합레진은 자연 치질을 보존시키며 나아가 잔존 치질의 강도를 강화시켜 준다. 복합레진 수복시 더 많은 치질을 남기기 위해 첨와 (undercut) 형태의 교합면 치질을 남긴 채 복합레진으로 수복하는 경우가 많으나, 어느 정도 강도가 복원되는지에 대해서는 잘 알려져 있지 않다. 이에 본 연구에서는 첨와 형태의 와동을 잔존 치질의 두께 (법랑질 / 법랑질과 상아질)에 따라 형성하고 복합레진으로 충전한 경우, 수복된 치아의 파절 저항성을 손상이 없는 자연치와 비교평가하였다. 상악 대구치 40개의 교합면을 편평하게 삭제한 후 방사선 사진에서 치수각의 위치를 확인하였다. 대상 치아를 각 10개씩 4개군으로 분류하였으며, 1$\sim$3군은 실험군으로 모두 협측에 깊이 7 mm, 근원심 폭경 5 mm의 첨와 형태 와동을 형성하였고, 와동저에서 치수각까지의 거리를 약 0.5 mm로 유지하였으며 교합면쪽의 치질 두께를 달리하였다. 1군은 법랑질과 소량의 상아질로 구성된 치질 두께를 1 mm, 2군은 법랑질과 상아질의 두께를 1.5 mm, 3군은 법랑질과 상아질의 두께를 2 mm가 되도록 하였고, 4군은 건전한 자연치를 와동형성 없이 대조군으로 사용하였다. 두께 측정은 방사선 사진을 스캔한 후 길이 확대 프로그램을 이용하였다. 각 와동을 37% 인산으로 산부식한 다음 단일병 접착제 Single $Bond^{TM}$ (3M/ESPE, USA)를 적용하였고 혼합형 복합레진 Filtek $SZ-250^{TM}$ (3M/ESPE, USA)을 사용하여 적층 충전하였다. 치아를 실온에서 증류수에 24시간 동안 보관한 다음 Sof-Lex system (3M/ESPE, USA)을 사용하여 연마하였다. 이후 자가중합형 레진에 교합면을 기저부에 평행한 상태로 치근부를 매몰한 다음 Universal testing machine (Zwick Z010, Germany)에서 지름 3 mm의 staineless steel rod를 1 mm/min의 cross-head speed로 하중을 가하여 파절 강도를 측정하였다. 통계 분석은 95% 유의 수준의 One-way ANOVA와 Tukey test를 이용하였으며 다음과 같은 결과를 얻었다. 1. 와동 형성 후 복합레진을 수복한 군들은 대조군에 비해 약 75%의 파절 강도를 보였다. 2. 교합면쪽 잔존 치질의 두께에 따른 파절 저항은 유의한 차이를 보이지 않았다 (p > 0.05). 복합레진을 이용하여 첨와 형태의 와동을 수복한 후 파절 강도를 측정한 결과 건전 치아보다는 강도가 낮았지만, 상부의 잔존 치질이 대부분 법랑질로 이루어진 경우에도 복합 레진으로 수복하면 건전 치아 파절 강도의 75%까지 유지할 수 있다는 결론을 얻었다.

STRAIN AND TEMPERATURE CHANGES DURING THE POLYMERIZATION OF AUTOPOLYMERIZING ACRYLIC RESINS

  • Ahn Hyung-Jun;Kim Chang-Whe;Kim Yung-Soo
    • 대한치과보철학회지
    • /
    • 제39권6호
    • /
    • pp.709-734
    • /
    • 2001
  • The aims of this experiment were to investigate the strain and temperature changes simultaneously within autopolymerzing acrylic resin specimens. A computerized data acquisition system with an electrical resistance strain gauge and a thermocouple was used over time periods up to 180 minutes. The overall strain kinetics, the effects of stress relaxation and additional heat supply during the polymerization were evaluated. Stone mold replicas with an inner butt-joint rectangular cavity ($40.0{\times}25.0mm$, 5.0mm in depth) were duplicated from a brass master mold. A strain gauge (AE-11-S50N-120-EC, CAS Inc., Korea) and a thermocouple were installed within the cavity, which had been connected to a personal computer and a precision signal conditioning amplifier (DA1600 Dynamic Strain Amplifier, CAS Inc., Korea) so that real-time recordings of both polymerization-induced strain and temperature changes were performed. After each of fresh resin mixture was poured into the mold replica, data recording was done up to 180 minutes with three-second interval. Each of two poly(methyl methacrylate) products (Duralay, Vertex) and a vinyl ethyl methacrylate product (Snap) was examined repeatedly ten times. Additionally, removal procedures were done after 15, 30 and 60 minutes from the start of mixing to evaluate the effect of stress relaxation after deflasking. Six specimens for each of nine conditions were examined. After removal from the mold, the specimen continued bench-curing up to 180 minutes. Using a waterbath (Hanau Junior Curing Unit, Model No.76-0, Teledyne Hanau, New York, U.S.A.) with its temperature control maintained at $50^{\circ}C$, heat-soaking procedures with two different durations (15 and 45 minutes) were done to evaluate the effect of additional heat supply on the strain and temperature changes within the specimen during the polymerization. Five specimens for each of six conditions were examined. Within the parameters of this study the following results were drawn: 1. The mean shrinkage strains reached $-3095{\mu}{\epsilon},\;-1796{\mu}{\epsilon}$ and $-2959{\mu}{\epsilon}$ for Duralay, Snap and Vertex, respectively. The mean maximum temperature rise reached $56.7^{\circ}C,\;41.3^{\circ}C$ and $56.1^{\circ}C$ for Duralay, Snap, and Vertex, respectively. A vinyl ethyl methacrylate product (Snap) showed significantly less polymerization shrinkage strain (p<0.01) and significantly lower maximum temperature rise (p<0.01) than the other two poly(methyl methacrylate) products (Duralay, Vertex). 2. Mean maximum shrinkage rate for each resin was calculated to $-31.8{\mu}{\epsilon}/sec,\;-15.9{\mu}{\epsilon}/sec$ and $-31.8{\mu}{\epsilon}/sec$ for Duralay, Snap and Vertex, respectively. Snap showed significantly lower maximum shrinkage rate than Duralay and Vertex (p<0.01). 3. From the second experiment, some expansion was observed immediately after removal of specimen from the mold, and the amount of expansion increased as the removal time was delayed. For each removal time, Snap showed significantly less strain changes than the other two poly(methyl methacrylate) products (p<0.05). 4. During the external heat supply for the resins, higher maximum temperature rises were found. Meanwhile, the maximum shrinkage rates were not different from those of room temperature polymerizations. 5. From the third experiment, the external heat supply for the resins during polymerization could temporarily decrease or even reverse shrinkage strains of each material. But, shrinkage re-occurred in the linear nature after completion of heat supply. 6. Linear thermal expansion coefficients obtained from the end of heat supply continuing for an additional 5 minutes, showed that Snap exhibited significantly lower values than the other two poly(methyl methacrylate) products (p<0.01). Moreover, little difference was found between the mean linear thermal expansion coefficients obtained from two different heating durations (p>0.05).

  • PDF

Creating a digitized database of maxillofacial prostheses (obturators): A pilot study

  • Elbashti, Mahmoud;Hattori, Mariko;Sumita, Yuka;Aswehlee, Amel;Yoshi, Shigen;Taniguchi, Hisashi
    • The Journal of Advanced Prosthodontics
    • /
    • 제8권3호
    • /
    • pp.219-223
    • /
    • 2016
  • PURPOSE. This study aimed to create a digitized database of fabricated obturators to be kept for patients' potential emergency needs. MATERIALS AND METHODS. A chairside intraoral scanner was used to scan the surfaces of an acrylic resin obturator. The scanned data was recorded and saved as a single standard tessellation language file using a three-dimensional modeling software. A simulated obturator model was manufactured using fused deposition modeling technique in a three-dimensional printer. RESULTS. The entire obturator was successfully scanned regardless of its structural complexity, modeled as three-dimensional data, and stored in the digital system of our clinic at a relatively small size (19.6 MB). A simulated obturator model was then accurately manufactured from these data. CONCLUSION. This study provides a proof-of-concept for the use of digital technology to create a digitized database of obturators for edentulous maxillectomy patients.

ENHANCED BIOAVAILABILITY OF NIFEDIPINE USING COATED DRY ELIXIR

  • Park, Jae-Yoon;Kim, Chong-Kook
    • 한국응용약물학회:학술대회논문집
    • /
    • 한국응용약물학회 1996년도 춘계학술대회
    • /
    • pp.282-282
    • /
    • 1996
  • The purpose of this study was to prepare the nifedipine dry elixir (NDE) and coated nifedipine dry elixir (CNDE) containing nifedipine ethanol solution for improving the dissolution rate and bioavailability of nifedipine. NDE containing nifedipine and ethanol in wall materials of dextrin was prepared using a spray-dryer and then NDE was coated with eudragit acrylic resin to make CNDE. Shape and size of the NDE and CNDE were monitored by scanning electron micrograph and laser particle size analyzer In vitro dissolution tests were performed in simulated gastric and intestinal fluid. Bioavailability of NDE and CNDE were compared with drug powder suspension and commercial soft capsule after oral administration of the preparations to rats. NDE and CNDE are spherical in shape. Cross-sectional view of dry elixirs indicates the large inter cavity containing ethanolic drug solution in shell. Geometric mean diameter of NDE and CNDE is about 6.64 and 8.70 $\mu\textrm{m}$, respectively. Drug dissolution rate within first 5 min from NDE increased dramatically irrespective of dissolution medium. However, CNDE showed a particularly retarded dissolution rate in pH 1.2 simulated gastric fluid compared with NDE. The bioavailability of nifedipine in the NDE was increased dramatically compared with drug powder suspension. CNDE reduced initial burst-out plasma peak compared with NDE. CNDE as a sustained release delivery system could reduce the initial burst-out plasma peak due to controlling the release rate of nifedipine from NDE and maintain the effective plasma level over a longer period within therapeutic window with enhanced bioavailability of nifedipine.

  • PDF

노즐 오리피스 형상 및 형상비가 디젤과 바이오디젤 연료의 노즐 내부 및 외부 유동특성에 미치는 영향 (Effect of Nozzle Orifice Shape and Nozzle Length-to-Diameter Ratio on Internal and External Flow Characteristics of Diesel and Biodiesel Fuel)

  • 박수한;서현규;이창식
    • 대한기계학회논문집B
    • /
    • 제31권3호
    • /
    • pp.264-272
    • /
    • 2007
  • The aim of this study is to investigate the effects of nozzle orifice shapes and the nozzle length-to-diameter ratio(L/D) on the nozzle cavitation formation inside the orifice and the external flow pattern. The nozzle used in this work was tested the taper orifice nozzle and the rectangular orifice nozzle which was made from the transparent acrylic acid resin. For studying the effect of the nozzle L/D ratio, it was used to three L/D ratios of 3.33, 10, and 20. The cavitation flow of nozzle was visualized by using the ICCD camera and optical system. This work revealed that the flow rate and discharge coefficient($C_d$) of the taper orifice nozzle was larger than those of the rectangular orifice nozzle at the same injection pressure. The cavitation flow was observed in the nozzle orifice at the low injection pressure and the breakup of liquid jet was promoted as the L/D ratio is decreased. The cavitation of biodiesel fuel was formed at the lower injection pressure than that of diesel fuel because of higher viscosity and density.

CAM Zirconia 완전도재 구조물의 정밀 적합도에 관한 연구 (A STUDY OF PRECISE FIT OF THE CAM ZIRCONIA ALL-CERAMIC FRAMEWORK)

  • 전미현;전영찬;정창모;임장섭;정희찬
    • 대한치과보철학회지
    • /
    • 제43권5호
    • /
    • pp.611-621
    • /
    • 2005
  • State of problem: Zirconia all-ceramic restoration fabricated with CAM system is on an increasing trend in dentistry. However, evaluation of the marginal and internal fits of zirconia bridge seldomly have been reported. Purpose: This study was to evaluate the at of margin and internal surface in posterior 3-unit zirconia bridge framework fabricated with CAM system(DeguDent, Germany). Material and Method: Preparations of secondary premolar and secondary molar on artificial resin model were performed for fabrication of 3-unit posterior bridge framework. Fits of 5 zirconia bridge framework were compared with 5 precious ceramo-metal alloy framework(V-GnathosPlus, Metalor, Switzerland), and prepared margins were designed to chamfer and shoulder finishing line. Each framework was cemented to epoxy resin model with reinforced glass ionomer(FujiCEM, GC Co., Japan), embedded in acrylic resin and sectioned in two planes, mesio-distal and buccolingual. Samples were divided into six pieces by sectioning and had two pieces of each surface(i.e mesial, distal, buccal and lingual surface) per abutment, so there were eight measuring points in each abutment. External gap was measured at the margin and internal gaps were measured at the margin, axial and occlusal surface. Gaps were observed under the measuring microscope(Compact measuring microscope STM5; Olympus, Japan) at a magnification of $\times100$. T-test were used to determine the statistic significance of the different gaps between zirconia and metal framework. Results and Conclusion: 1. External and internal marginal gaps of zirconia and metal framework were in clinically acceptable range. External marginal gaps were not different significantly between zirconia$(81.9{\mu}m)$ and metal $(81.3{\mu}m)$ framework and internal marginal gaps of zirconia $(44.6{\mu}m)$ were smaller than those of metal framework $(58.6{\mu}m)$. 2. Internal axial gaps of zirconia framework$(96.7{\mu}m)$ were larger than those of metal frame-work$(78.1{\mu}m)$ significantly and adversely, internal occlusal gaps of zirconia frame-work$(89.4{\mu}m)$ were smaller than those of metal framework $(104.9{\mu}m)$ significantly. 3. There were no significant differences in external and internal marginal gaps between chamfer and shoulder finish line when zirconia frameworks were fabricated.

Micro-computed tomographic evaluation of a new system for root canal filling using calcium silicate-based root canal sealers

  • Tanomaru-Filho, Mario;Torres, Fernanda Ferrari Esteves;Pinto, Jader Camilo;Santos-Junior, Airton Oliveira;Tavares, Karina Ines Medina Carita;Guerreiro-Tanomaru, Juliane Maria
    • Restorative Dentistry and Endodontics
    • /
    • 제45권3호
    • /
    • pp.34.1-34.7
    • /
    • 2020
  • Objectives: This study evaluated by using micro-computed tomography (micro-CT) the filling ability and sealer apical extrusion promoted by a new Sealer Injection System (SIS; Angelus) with side openings needle, in comparison with the conventional injection system, associated with a new ready-to-use calcium silicate-based sealer (Bio-C Sealer). Materials and Methods: Acrylic resin models containing a main curved artificial canal and 3 simulated lateral canals in apical, middle and cervical thirds were used. The main root canals were prepared using a rotary system up to size 35.05. The canals were filled with Bio-C sealer by using a single cone technique and the conventional delivery system or SIS. Samples were scanned in micro-CT. The percentage of voids throughout the entire extension of the main root canal and in each third of the lateral canals, besides the apical extrusion of the sealer was calculated. Data were submitted to t-test (p < 0.05). Results: There was no difference between both systems in the main root canals filling. Although the volume percentage of voids was similar in the apical and middle thirds of lateral canals, SIS had the greatest filling ability of the cervical third lateral canal. Moreover, the conventional system showed the highest apical extrusion of the sealer. Conclusions: The conventional and SIS obturation systems had an appropriate filling ability of the main root canal. SIS had the best filling of the cervical third of the lateral canals, besides lower sealer apical extrusion, suggesting its clinical indication.