• 제목/요약/키워드: Acrylic resin system

검색결과 73건 처리시간 0.025초

임상적 방법을 이용한 내부연결 임플랜트에서 고정체수준 인상법의 정확도 평가 (EVALUATION OF THE ACCURACY OF FIXTURE-LEVEL IMPRESSION TECHNIQUE FOR INTERNAL CONNECTION IMPLANT USING CLINICAL METHODS)

  • 최정한
    • 대한치과보철학회지
    • /
    • 제44권4호
    • /
    • pp.421-431
    • /
    • 2006
  • Statement of problem : Accurate impression is essential to success of implant prostheses. But there have been few studies about the accuracy of fixture-level impression technique in internal connection implant system. Purpose: This study evaluated the accuracy of splinted fixture-level impression technique using clinical methods and the effect of internal hex on fit of superstructure in internal connection implant system (Astra Tech). Material and method : Two metal master frameworks made from two abutments (Cast-to Abutment ST) each for parallel and divergent conditions and a corresponding. passively fitting, dental stone master cast with four future replicas (Fixture Replica ST) were fabricated. Ten dental stone casts were made with vinyl polysiloxane impressions from the master cast by acrylic resin splinted fixture-level impression technique. To evaluate the accuracy of impression technique, the fit of master frameworks for test models was evaluated using screw resistance test (SRT) and one-screw test. The results of SRT were recorded as SRT values from grade 1 to grade 5 by 1/4 turn. And to evaluate the effect of hex on fit of superstructure, the same tests were performed after removing hexes of master frameworks. Results: 1. There was only one case (2.5%) showing SRT value of test model below ade 2 in total before and after removing hexes of master frameworks. And, by removing hexes. SRT values decreased in only one test model (5%) and did not change in 17 test models (85%). 2. SRT values of the 1$^{st}$ screws were grade 2 in 80% of cases before, and grade 1 in 80% of cases after removing hexes. And, by removing hexes, SRT values decreased in 72.5% of cases. 3. SRT values of the 2$^{nd}$ screws were grade 3 in 85% of cases before, and grade 3 in 95% of cases after removing hexes. And, by removing hexes, SRT values did not change in 85% of cases. 4. There were only 2 cases regarded as acceptable fit by one-screw test, and SRT values of 2$^{nd}$ screws of both cases were grade 2. Conclusion. Within the limitations of this study, future-level impression of internal connection implant system is considered to obtain inaccurate working cast, even using acrylic resin splinted impression technique. And, it is considered to be unable improve the fit to remove the hexes of implant restoration.

도료용 폴리올 종류에 따른 폴리이소시아네이트와의 물성 (The Properties of Different Polyols for Paint to Polyisocyanate)

  • 서석환;서차수;박진환
    • 공업화학
    • /
    • 제19권5호
    • /
    • pp.547-553
    • /
    • 2008
  • 도막의 기능은 피도물의 노출 환경 및 요구되는 물성에 따라 수지종류와 경화제는 적절하게 설계되어야 그 기능을 충분히 발휘할 수 있다. 본 연구에서는 동일한 OH 함량을 가진 알키드 폴리올, 폴리에스테르 폴리올, 폴리에스테르 변성아크릴 폴리올 등과 $T_g$ 및 OH 함량이 다른 아크릴 폴리올 수지 등 6가지 폴리올수지를 사용하고, 경화제는 알리파틱 이소시아네트와 아로마틱 이소시아네트를 사용하였다. 총 12종류의 투명도료를 제조 후, 화학적, 기계적 물성시험과 DMA 및 Rheometer를 이용하여 폴리올 수지타입 및 경화제 타입에 따른 폴리우레탄 도료의 종류별 도막물성 및 작업성을 관찰하였다. 그 결과 폴리올수지에 있어서 각각 다른 물리적, 화학적 성질을 가지는 도료개발 및 도장작업성의 개선 시 적절한 폴리올수지 종류 및 경화제를 선택하여 상 하도의 물성 및 도장 시스템에 합리적으로 응용할 수 있는 결과를 얻었다.

의치상용 레진의 전입 방법에 따른 중합체적변화와 굴곡강도에 관한 연구 (DIMENSIONAL CHANGE AND FLEXURAL STRENGTH IN COMPLETE DENTURES FABRICATED BY INJECTION MOLDING AND CONVENTIONAL COMPRESSION PROCESSING)

  • 최훈달;권긍록;김형섭;최대균
    • 대한치과보철학회지
    • /
    • 제43권4호
    • /
    • pp.478-486
    • /
    • 2005
  • Statement of problem : Fracture and dimensional change of an acrylic resin denture are a rather common occurrence. Purpose : The purpose of this study was to compare differences in dimensional changes and flexural strength of separate maxillary complete dentures after immediate deflasking by injection molding and conventional compression processing. Material and method: To evaluate dimensional stability, the maxillary dentures were fabricated by using different materials and methods. Lucitone 199(Dentsply Trubyte. york, pennsylvania, USA) and Vertex(Dentimex, zeist, Netherlands) were used as materials. Compression and injection packing methods were used as processing methods. The impression surface of the dentures was measured by 3D Scann-ing System(PERCEPTRON USA) and overlapped original impression surface of the master cast. To evaluate flexural strength, resin specimens were made according to the different materials, powder/liquid ratio and processing methods. Flexural strength of the complete resin specimens (64mm$\times$10mm$\times$3.3mm) were measured by INSTRON 4467. (INSTRON, England) The data was analyzed by ANOVA, t-test and Tukey test. (p<.05 level of significance) Result: The results were as follows 1. There was no significant differences between master model and denture base for each group in overall dimensional changes. 2. Palatal area was more stable than flange or alveolar area in dimensional stability. but. there was no significant differences among each area. 3. Materials and power/liquid ratio had an effect on flexural strength. (P<.05) Especially materials was most effective. (P<.05) 4. Lucitone 199(powder/liquid ratio followed by manufacturer's direction) showed higher flexural strength than Vertex. Conclusion : Dimensional stability or flexural strength are affected by materials rather than packing techniques.

콘포멀 스프레이 코팅으로 형성한 EMI 차단막의 차폐효과 개선 (Improvement for Shielding Effectiveness of EMI Shield Layers using Conformal Spray Coating Scheme)

  • 허정;이원희
    • 한국인터넷방송통신학회논문지
    • /
    • 제18권6호
    • /
    • pp.107-112
    • /
    • 2018
  • 콘포멀 스프레이 코팅으로 형성한 EMI 차단막으로 차폐효과(SE)를 얼마나 개선할 수 있는지 연구하였다. 차단막을 형성하는데 사용한 재료는 도체 분말을 아크릴계 바인더에 혼합한 금속-레진 복합재료이며, 금속분말로는 은(Ag)과 니켈(Ni)을 비교하였다. 재료의 점도는 400 cPs와 100 cPs에서 차폐성능을 비교하였다. 차단막의 두께는, 은의 경우 20 um에서 50 um, 니켈의 경우 60 um에서 120 um로 만들어 비교하였다. 차폐효과의 측정은 동축형 표준 측정기를 이용하여 ASTM D4935 방법으로 수행하였다. 니켈 시료보다 은 시료의 차폐효과가 우수했다. 차폐효과는 차단막 두께와 비례해 증가하지만 35 um 이상에서 더 이상 증가하지 않는다는 사실도 관찰하였다. 가장 차폐효과가 좋은 경우는 35 um 두께 은 시료 차단막으로, 63 dB의 차폐효과가 측정되었다.

A modified device for intraoral radiography to assess the distal osseous defects of mandibular second molar after impacted third molar surgery

  • Ana, Faria-Inocencio;Mercedes, Gallas-Torreira
    • Imaging Science in Dentistry
    • /
    • 제41권3호
    • /
    • pp.115-121
    • /
    • 2011
  • Purpose : This article is to describe a modified device for intraoral radiography which was developed to obtain reproducible radiographic images for assessment of distal osseous defects of the mandibular second molar (2 Mm) after impacted third molar (3 Mm) surgery. Materials and Methods : A commercial available alignment system for posterior region was modified by adding a reference gauge pin (millimetric) and threading a hollow acrylic cylinder at the ring of the radiographic positioner to attach the X-ray collimator. The design included customized resin acrylic stent for the occlusal surface of the 2Mm in maximum intercuspal position, individualizing the biteblock positioner. Periapical radiographs were taken before and after surgical extraction of 3 Mm, employing the radiographic technique of parallelism described by Kugelberg (1986) with this modified film holder and inserting the gauge pin on the deepest bone probing depth point. Results : This technique permitted to obtain standardized periapical radiographs with a moderate to high resolution, repeatability, and accuracy. There was no difference between the measurements on the pre- and post-operative radiographs. This technique allowed better maintenance of the same geometric position compared with conventional one. The insertion of the gauge pin provided the same reference point and localized the deepest osseous defect on the two-dimensional radiographs. Conclusion : This technique allowed better reproducibility in posterior radiographic records (distal surface of 2 Mm) and more accurate measurements of radiographic bone level by the use of a millimetric pin.

입자영상유속계와 컴퓨터 시뮬레이션을 이용한 분기관내 유동해석 (Flow Analyses in the Bifurcated Duct with PIV System and Computer Simulation)

  • 서상호;최을;노형운;도덕희
    • 대한기계학회논문집B
    • /
    • 제23권1호
    • /
    • pp.123-130
    • /
    • 1999
  • The objective of the current study is to understand steady 3-dimensional flow phenomena in a bifurcated duct experimentally. A bifurcation model is fabricated with transparent acrylic resin to visualize the whole flow field with the PIV system. The gray level cross-correlation method is applied to the image processing algorithm. The subpixel and the area interpolation methods are used to obtain the final velocity vectors. The finite volume predictions are used to analyze the flow patterns in the bifurcation model. The results of the computer simulation and the PIV experiment for three-dimensional flow show the recirculation zone and the formation of the paired secondary flow distal to the apex of the bifurcation model. The results obtained with the two methods also show that the branch flow strongly strikes the inner wall due to the inertial effect and accompanied helical motion as it flows toward the outer wall.

산부식처리(酸腐蝕處理) 치아법랑질(齒牙琺瑯質) 표면(表面)의 조도(粗度)에 관(關)한 실험적(實驗的) 연구(硏究) (AN EXPERIMFNENTAL STUDY ON THE SURFACE ROUGHNESS OF ACID ETCHING ENAMEL SURFACE IN HUMAN TEETH)

  • 이은구
    • Restorative Dentistry and Endodontics
    • /
    • 제5권1호
    • /
    • pp.13-18
    • /
    • 1979
  • The purpose of this study was to measure the roughness on the acid -etching surface. The etching agents of three-kinds composite resins were used to etch the tooth surface. Newly extracted I5-anterior teeth were invested with self-curing acrylic resin, and the labial surface was exposed. The exposed labial side was polished with abrasive papers and finally polished on polishing machine with zinc oxide powder. After the teeth were polished, the specimens were washed by water and dried by air. Surface roughness tester, Taylor-Habson's Taly Surf-10, (Fig-1) was used to measure roughness of this unetched tooth surface. And that, the specimens were divided into three groups. The first group was etched with Restodent etchant, the second group was etched with Nuva-system etchant, and Hi-pol etching agent was used in the third group. And the surface roughness tester was used to measure roughness of the etching teeth surface. The results obtained were as follows. 1. The roughness of acid-etched enamel were increased $2{\mu}m$ to $6{\mu}m$. 2. Hi-pol etchant produced the smoothest surface($2.3{\mu}m$). 3. Restodent etchant($3.8{\mu}m$) and Nuva-system etchant($3.7{\mu}m$) produced rougher surface than Hi-pol.

  • PDF

변형된 임플란트 임시 지대주의 물성에 대한 연구 (The Study on the Physical Property of Provisional Prosthesis using Modified Temporary Abutment)

  • 양병덕;윤태호;최운재;박주미
    • 구강회복응용과학지
    • /
    • 제22권4호
    • /
    • pp.329-340
    • /
    • 2006
  • Statement of problem: Damping of the peak force transmitted to implants has been reported by in vitro studies using impact forces on resin-veneered superstructures. Theoretical assumptions suggest that use of acrylic resin for the occlusal surfaces of a prosthesis would protect the connection between implant and bone. Therefore, the relationship between prosthesis materials and the force transmitted through the implant system also needs to be investigated under conditions that resemble the intraoral mechanical environment. Purpose: The purpose of this study was to analyze the fracture strength and modes of temporary prosthesis when a flange or occlusally extended structure were connected on the top of the abutment. Material and method: Modified abutments of winged and bulk design were made by casting the desired wax pattern which is made on the UCLA type plastic cylinder. Temporary crowns were made using templates on the modified abutments, and its fracture toughness and strain were compared to the traditional temporary prosthesis. To evaluate the effect of aging, 5.000 times of thermocycling were performed, and their result was compared to the 24hours specimen result. Results: The following conclusions were drawn from this study: 1. In the fracture toughness test, temporary crown's fracture line located next to the screw hole while modified designs with metal support showed fracture line on the metal and its propagation along the metal-resin interface. 2. Wing and bulk structure didn't show significant difference in the fracture toughness (p>0.05), but wing structure showed stress concentration on the screw hole area compared to bulk structure which showed even stress distribution. 3. In the fracture toughness test after thermocycling, wing and bulk structure showed increased or similar results in metal supported area while off-metal area and temporary crown showed decreased results. 4. In the strain measurement after thermocycling, its value increased in the temporary and bulk structure. However, wing structure showed decreased value in the loading point while increased value in the screw hole area. Conclusion: Wing type design showed compatible result to the bulk type that its application with composite resin prosthesis to the implant dentistry is considered promising.

A SHEAR BOND STRENGTH OF RESIN CEMENT BONDED TO HUMAN UNCUT ENAMEL, CUT ENAMEL, AND DENTIN IN VITRO

  • Lee Jong-Yeop
    • 대한치과보철학회지
    • /
    • 제41권3호
    • /
    • pp.319-324
    • /
    • 2003
  • Statement of problem. Adhesives in dentistry playa major role in the success of restorative treatments. In the treatment of all ceramic restoration it is needed to find the adequate bond strength between enamel and dentin. Purpose. The purpose of this study was to evaluate shear bond strength of resin cement bonded to extracted human uncut enamel, cut enamel, and dentin in vitro. Material and methods. Ten freshly extracted anterior teeth without any previous restorative treatments were chosen. The extracted teeth were embedded in PMMA cold acrylic in the shape of a cylinder, 25 mm in diameter by 25 mm in height. The bonding system used was as follow: Uni-Etch (32% phosphoric acid), One-Step adhesive, Duolink resin cement. The specimens were acid etched and rinsed with water. Two layers of One-Step adhesive were coated with a disposable brush on the uncut enamel. VIP curing light at $500mV/cm^2$ was used to cure the adhesive. For cut enamel shear bond test, the specimen used for uncut enamel was further reduced approximately $0.3{\sim}0.5mm$ using a laminate preparation diamond bur (0.3 mm in depth). The specimens were subsequently treated with 320-grit SiC paper followed by 600-grit SiC paper and cleaned with distilled water. The bonding procedure on the cut enamel was same as uncut enamel bonding procedure. For dentin bonding test, the specimen used for cut enamel was further reduced approximately $0.5mm{\sim}1.0mm$ using a laminate preparation diamond bur (0.5 mm in depth of diamond cutting). The amount of reduction was evaluated with the silicone mold. The specimens were subsequently treated with 320-grit SiC paper followed by 600-grit silicon carbon paper and cleaned in distilled water. The bonding procedure on the dentin was same as uncut enamel bonding procedure. All samples were mounted and secured on the Ultradent shear bond test sample holder, and Ultradent restricted shear bond testing device was used with Universal Instron machine until fracture. Analysis of variance (ANOVA) test was performed comparing the result at P<0.05. Multiple comparison (Tukey) was used to compare each groups. Result. The result showed that the mean value in shear bond strength of resin cement bonded to uncut enamel, cut enamel and dentin were 27.04 Mpa, 30.25 Mpa and 26.39 Mpa with respect. Conclusion. Within the limitation of this study, the mean value of the shear bond strength of cut enamel was higher than those of uncut enamel or dentin. However there existed no statistical differences between three different human dentition substrates due to increased adhesive characteristics.

All-in-one 접착제에서 초음파진동이 법랑질과 상아질의 결합강도와 레진침투에 미치는 영향 (EFFECT OF ULTRASONIC VIBRATION ON ENAMEL AND DENTIN BOND STRENGTH AND RESIN INFILTRATION IN ALL-IN-ONE ADHESIVE SYSTEMS)

  • 이범의;장기택;이상훈;김종철;한세현
    • 대한소아치과학회지
    • /
    • 제31권1호
    • /
    • pp.66-78
    • /
    • 2004
  • 초기의 접착 시스템은 여러 단계의 술식을 필요로 하였으며 술자의 기술과 재료의 성질에 크게 좌우되었으나 최근 산부식, priming, adhesive를 한번에 적용할 수 있는 all-in-one adhesive system이 등장하였다. 치과에서의 vibration의 이용은 치석의 제거 및 접착제의 점도를 낮추는데 이용되어왔으며 vibration은 접착제의 흐름성을 향상시켜 film thickness를 낮추어 수복물 주위의 미세누출을 줄이는데 도움을 준다. 이에 저자들은 all-in-one adhesive system에서 vibration이 법랑질과 상아질의 접착강도와 레진침투에 미치는 효과를 알아보고자 하였다. 법랑질 시편은 발거 후 실온에서 0.1% thymol 용액에서 보관된 30개의 건전한 사람의 대구치를 무작위로 10개씩 세군으로 나누고 근원심 방향으로 두 부분으로 분리하여 각각은 같은 접착제를 사용하고 초음파진동여부를 다르게 하였고, 아크릴레진을 이용하여 직경 1-inch의 PVC관에 매몰한 후 협설면이 아크릴봉과 동일한 높이가 되도록 220-, 600-grit 연마지로 순차적으로 연마하였고 군당 10개씩 여섯 군으로 분류하였다. 1군과 2군은 Prompt L-Pop(3M-ESPE, Seefeld, Germany), 3군과 4군은 One-Up Bond F(Tokuyama Corp., Tokyo, Japan), 5군과 6군은 AQ bond(Sun Medical Co., Kyoto, Japan)를 제조사의 지시에 따라 도포하였다. 2군, 4군, 6군은 초음파 치석제거기를 이용하여 치면에 대고 15초간 진동을 가한 후 광중합하였다. 상아질 시편은 치관부 법랑질을 제거한 후 상아질면을 아크릴 봉과 동일한 높이가 되도록 하고 법랑질 시편과 동일하게 처리하였다. 이후 직경 2mm, 높이 3mm의 Teflon mold(Ultradent, U.S.A.)를 이용하여 복합레진을 충전한 후 40초씩 두 번에 나누어 광중합한 후 24시간동안 실온에서 증류수에 보관하였다. 열순환 시행한 후, 만능측정기(Instron 4465)로 전단결합강도를 측정하였으며 Resin tag의 양상을 비교하기 위해 각 군의 시편의 치질을 완전히 용해시킨 후 표면을 주사전자현미경사진으로 관찰하여 다음과 같은 결과를 얻었다. 1 법랑질에서 초음파 진동을 가한 군(2, 4, 6군)은 가하지 않은 군(1, 3, 5군)에 비해 평균 전단결합강도가 높게 나타났다. 그 차이는 Ad bond 군을 제외하고 통계적으로 유의하였다(p<0.05). 2. 상아질에서 초음파 진동을 가한 군(2, 4, 6군)은 가하지 않은 군(1, 3, 5군)에 비해 평균 전단결합강도가 높게 나타났다. 그러나 그 차이는 One-Up Bond F군을 제외하고는 통계적으로 유의한 차이가 없었다. 3. 전자 현미경 관찰에서 초음파 진동을 가한 군에서 더 많은 법랑질의 소실과 상아질에서 resin tag의 길이가 길었고 lateral branch의 수도 많이 관찰되었다.

  • PDF