• 제목/요약/키워드: Acoustic variation

Search Result 355, Processing Time 0.024 seconds

Vibration and Acoustic Noise characteristic on SRM with compensating winding by two stage commutation (2단계 소호전압방식을 적용한 보상권선형 SRM의 진동.소음특성)

  • 오석규;이종근;최태완
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.6 no.3
    • /
    • pp.250-257
    • /
    • 2001
  • SRM drives generate large vibration and acoustic noise because it is rotated by step pulse mmf and switching commutation mechanism. The main vibration source of SRM drive is generated by rapidly variation of radial force when phase winding current is extinguished for commutation action. So the rapidly variation of radial force is repressed firstly to reduce vibrating force of SRM drive. This paper suggests an SRM excitation scheme using unidirect-short compensation winding to reduce vibration of the motor. The motor is excited by a two stage commutation method during commutation period. This paper suggests an SRM excitation scheme using unidirect-short compensation winding to reduce vibration of the motor. The motor is excited by a tow stage commutation method during commutation period. This reduction effect of vibration is verified with the result obtained in the test of prototype machine.

  • PDF

The Effect of the Treatment on the Pre- and Post Respiration and the Oral Motor for Children with Cerebral Palsy by Acoustic Analysis (음향학적 분석을 통한 뇌성마비 아동의 호흡 및 구강 운동 전.후 치료 효과)

  • Kim, Sook-Hee;Kim, Hyun-Gi;Shin, Yong-Il
    • Speech Sciences
    • /
    • v.15 no.2
    • /
    • pp.131-141
    • /
    • 2008
  • The purpose of this study was to find out the acoustic variation on the pre-and post respiration and oral motor for children with cerebral palsy. Five children with spastic CP at the age of 6 in average were practiced by a caregiver at home each for 25 minutes, in total, 45 times. The sustained of vowel /a/ and vowels /a/, /i/, /u/, /e/, /o/ were recorded on CSL and MDVP and analyzed by acoustic parameters. As a result, the maximum phonation time(MPT) was increased from 2.06 to 6.31 and the formant of vowels(F1, F2, F3) had significant differences in F1(/a, i/), F2(/i.u.o/), and F3(/a/) between the controls and the children with CP in pre-treatment. The total average value of vowels had significant differences between the pre-and post-treatment (p< .05). The energy of vowels had significant differences in the vowels /i, u, e, o/ and the total average value between the pre-and post-treatment(p< .001). The jitter percent, shimmer percent, and noise to harmonic ratio had significant differences between the pre-and post-treatment(p< .05). As the respiration and the oral motor improved MPT, voice quality, and articulation of vowel, and the variation of the formant(F1, F2, F3) showed the changes in the shape of lips, the place and the height of the tongue, the various development of therapy programs and the consistent intervention of treatment is needed for the children with cerebral palsy.

  • PDF

The Effects of Changing the Respiratory Muscles and Acoustic Parameters on the Children With Spastic Cerebral Palsy (체간 조절을 통한 앉기 자세 교정이 경직형 뇌성마비 아동들의 호흡근과 음향학적 측정치들의 변화에 미치는 효과)

  • Kim, Sun-Hee;Ahn, Jong-Bok;Seo, Hye-Jung;Kwon, Do-Ha
    • Physical Therapy Korea
    • /
    • v.16 no.2
    • /
    • pp.16-23
    • /
    • 2009
  • The purpose of this study was to investigate the effects postural changes on respiratory muscles and acoustic parameters of the children with spastic cerebral palsy. Nine children with spastic cerebral palsy who required assistance when walking were selected. The ages of the children ranged from 6 to 9 years old. The phonation of the sustained vowel /a/ and the voice qualities of each child such as fundamental frequency($F_0$; Hz), pitch variation (Jitter; %), amplitude variation (Shimmer; %) and noise to harmonic ratio (NHR) were analyzed by Multi-Dimensional Voice Program (MDVP). The muscle activity of three major respiratory muscles: pectoralis major muscle, upper trapezius muscle and rectus abdorminalis muscle, were measured by examining the root mean square (RMS) of the surface EMG to investigate the impact of changes in the adjusted sitting posture of each subject. However, the RMS of pectoralis major muscle showed a significant differences (p<.05). Secondly, there were no significant differences in $F_0$, Jitter and Shimmer between pre and post posture change, but there was a significant difference in NHR (p<.05). The data were collected in each individual; once prior and once after the sitting posture change. The data were analyzed by Wilcoxon signed ranks-test using SPSS version 14.0 for Windows. The findings of this study were as follows; Firstly, the RMS of upper trapezius and rectus abdorminalis muscle were not significant different between pre and post sitting posture changes. From the result, it is concluded that changes in the adjusted sitting posture decreases the abnormal respiratory patterns in the children with spastic cerebral palsy which is characterized by the hyperactivity of the respiratory muscles in breathing. Also, there is increased on the voice qualities in children with spastic cerebral palsy.

  • PDF

Thermal Sensitivity of the Bean Curd by Ultrasonic Irradiation (초음파 조사에 의한 두부의 열 감도)

  • 조문재;윤용현;부유천;김용태
    • The Journal of the Acoustical Society of Korea
    • /
    • v.23 no.7
    • /
    • pp.503-513
    • /
    • 2004
  • In this paper, the thermal sensitivity, i .e. the temperature rise per unit acoustic power, was newly defined and proposed as a performance parameter of a tissue mimicking material. Eatable tofu (bean curd) manufactured by a factory was selected as a sample material for the experiment. The temperature changes were measured not only with the variation of ultrasonic irradiation time, acoustic power, depth from the sample surface. and the distance from the source transducer while adjusting the frequency to 8 MHz but also with the variation of frequency while acoustic power. depth from the sample surface. and the distance from the source transducer keeping constant. As a result of a consideration for the transformation of the measured temperature changes to thermal sensitivities. the thermal sensitivity was found to be sufficient to use as a Performance parameter for tissue mimicking material. The tofu as a tissue mimicking material showed the maximum thermal sensitivity at 10 MHz, as is a significant result to imply the possibility that the thermal sensitivity of real human tissue strong1y depends on the frequency.

Optimum Monitoring Parameters for the Safety of Mechanical Seals (미캐니컬 씰의 안전운용 감시를 위한 최적 계측인자)

  • Soon-Jae Lim;Man-Yong Choi
    • Journal of the Korean Society of Safety
    • /
    • v.12 no.4
    • /
    • pp.214-219
    • /
    • 1997
  • The mechanical seals, which are installed in rotating machines like pump and compressor, are generally used as sealing devices in the many fields of industries. The failure of mechanical seals such as leakage, crack, breakage, fast and severe wear, excessive torque, and squeaking results in big problems. To identify abnormal phenomena on mechanical seals and to propose the proper monitoring parameter for the failure of mechanical seals, sliding wear experiments were conducted. Acoustic emission, torque, and temperature were measured during experiments. Optical microstructure was observed for the wear processing after every 10 minute sliding at rotation speed of 1750 rpm and scanning electron microscopy was also observed. Except for the initial part of every experiment, the variation of acoustic emission was well coincided with torque variation during the experiments. This study concludes that acoustic emission and torque are proper monitoring parameters for the failure of mechanical seals. The intensity of acoustic emission signals is measured in root mean square voltage. Temperature of sealing face will be used as a parallel parameter for increasing the reliability of monitoring system.

  • PDF

Wireless RF Sensor Structure for Non-Contact Vital Sign Monitoring

  • Kim, Sang-Gyu;Yun, Gi-Ho;Yook, Jong-Gwan
    • Journal of electromagnetic engineering and science
    • /
    • v.12 no.1
    • /
    • pp.37-44
    • /
    • 2012
  • This paper describes a compact and novel wireless vital sign sensor at 2.4 GHz that can detect heartbeat and respiration signals. The oscillator circuit incorporates a planar resonator, which functions as a series feedback element as well as a near-field radiator. The periodic movement of a human body during aerobic exercise could cause an input impedance variation of the radiator within near-field range. This variation results in a corresponding change in the oscillation frequency and this change has been utilized for the sensing of human vital signs. In addition, a surface acoustic wave (SAW) filter and power detector have been used to increase the system sensitivity and to transform the frequency variation into a voltage waveform. The experimental results show that the proposed sensor placed 20 mm away from a human body can detect the vital signs very accurately.

A Study on the Acoustic-Field Analysis of the Suction Housing using the Reverse Engineering (Reverse Engineering을 이용한 석션 하우징의 음장해석)

  • Yang, Jeong-Jik;Lee, Dong-Ju
    • Journal of the Korean Society of Manufacturing Technology Engineers
    • /
    • v.20 no.4
    • /
    • pp.464-471
    • /
    • 2011
  • We tried to analyze sound field of the interior of housing installed with an impeller using the Boundary Element Method (BEM) with the Kirchhoff-Helmholtz integral equation. In order to increase the accuracy of our analysis, reverse engineering technology, which has been developed in recent years. We measured and treated geometrical data with 3D scanning of the practical research object. After modeling by the reverse engineering, we analyzed variation of the BPF as adding vibration frequency and variation of the sound field of the interior of housing by changing the number of impeller blades. We also tried an analysis of free degree variation. Then, we proposed the analysis accuracy and noise reducing method by analysis result.

Fatigue Life Prediction for the Skin Structures of Aircraft Sensor Pod Under Acoustic Load with Mean Stress (평균 응력을 고려한 음향 하중을 받는 항공기 센서 포드 외피 구조의 내구 수명 분석)

  • Min-Hyeok Jeon;Yeon-Ju Kim;Hyun-Jun Cho;Mi-Yeon Lee;In-Gul Kim;Hansol Lee;Jae Myung Cho;Jong In Bae;Ki-Young Park
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.26 no.1
    • /
    • pp.1-9
    • /
    • 2023
  • The skin structure of sensor pod mounted on the exterior of aircraft can be exposed to the acoustic dynamic load and static load such as aerodynamic pressure and inertial load during flight. Fatigue life prediction of structural model under acoustic load should be performed and also differential stiffness of model modified by static load should be considered. The acoustic noise test spectrum of MIL-STD-810G was applied to the structural model and the stress response power spectral density (PSD) was calculated. The frequency response analysis was performed with or without prestress induced by inplane static load, and the response spectrum was compared. Time series data was generated using the calculated PSD, and the time and frequency domain fatigue life were predicted and compared. The variation of stress response spectrum due to static load and predicted fatigue life according to the different structural model considering mean stress were examined and decreasing fatigue life was observed in the model with prestress of compressive static load.

Estimation of Phase Variance of Acoustic Signals Depending on Turbulence Strength Near the Mukho Port in the East Sea of Korea (동해 묵호항 근처에서의 난류세기인자에 따른 음향수신신호의 위상분산 추정)

  • Kim, Jung-Hun;Bok, Tae-Hoon;Paeng, Dong-Guk;Shim, Tae-Bo;Kim, Young-Kyu;Park, Joung-Soo
    • The Journal of the Acoustical Society of Korea
    • /
    • v.28 no.4
    • /
    • pp.328-335
    • /
    • 2009
  • Phase variance of the acoustic signals has to be investigated with the research of the medium, because the phase of the acoustic signals carries the information of the medium. The phase compensation of the received signals is required for the signal processing of SAS (Synthetic Aperture Sonar) and underwater communication. In this paper, the phase variance of the acoustic signals was studied depending on the micro-scale-turbulence of ocean. The turbulence strength of the locally isotropic and homogeneous turbulence was calculated, and the phase variance affected by the turbulence strength was computed along the ray paths. The CTD and ADCP data were acquired from a buoy system near the Mukho port in the East Sea of Korea and the ray paths were calculated by the Bellhop algorithm. As a result, the turbulence strength was mainly determined by the variation of temperature and flow speed, changing the phase variance of the received signals. Hence, we thought the phase variance should be considered in the sonar operating system.

Changes in Acoustic Parameters According to Intensity Increase in Voice Assessment (음성질환자의 음성검사 시 강도 증가에 따른 음향학적 지표의 변화)

  • Nam, Do-Hyun;Rheem, Sung-Sue;Yun, Bo-Ram;Cho, Sun-A;Choi, Hong-Shik
    • Journal of the Korean Society of Laryngology, Phoniatrics and Logopedics
    • /
    • v.22 no.2
    • /
    • pp.143-150
    • /
    • 2011
  • Background and Objectives : Clinically, as a tool for voice assessment before and after the operation or the voice treatment, acoustic analysis is widely used. However, in clinical situations, acoustic parameters vary according to how the assessment is made. Thus, with voice disease patients as subjects, we are to investigate what influence intensity increase exerts on acoustic parameters and how to reduce variation according to the way of assessing. Material and Method : At the voice clinic of the department of otorhinolaryngology in Gangnam Severance Hospital, with 30 female voice-disease patients (40.6 years old on the average) and 23 male voice-disease patients (40.1 years old on the average) as subjects, using the Dr Speech vocal-assessment program, we statistically tested the significance of the difference in each of acoustic parameters between when the "Ah" vowel is produced with a normal voice and when the "Ah" vowel is produced with a loud voice. Results : Acoustic parameters that showed a statistically significant difference according to intensity increase were Jitter, SD F0, and NNE for females, and Jitter, SD F0, HNR, SNR, and NNE for males. Voice quality estimates showed a statistically significant difference according to intensity increase in female hoarse voice, female breathy voice, and male breathy voice. Conclusion : In this research, acoustic analysis, which is generally used for voice assessment before and after the operation or the voice treatment, showed a tendency that acoustic parameters became better under the influence of intensity increase except for the cases where a voice disease was severe. Thus, to raise the reliability of voice assessment, the range of intensity needs to be set up. This should be the topic for the future research.

  • PDF