• 제목/요약/키워드: Acoustic study

검색결과 3,596건 처리시간 0.035초

Study and Experimentation on Detection of Nicks inside of Porcelain with Acoustic Emission

  • Jin, Wei;Li, Fen
    • 한국멀티미디어학회논문지
    • /
    • 제9권12호
    • /
    • pp.1572-1579
    • /
    • 2006
  • An usual acoustic emission(AE) event has two widely characterized parameters in time domain, peak amplitude and event duration. But noise in AE measuring may disturb the signals with its parameters and aggrandize the signal incertitude. Experiment activity of detection of the nick inside of porcelain with AE was made and study on AE signal processing with statistic be presented in this paper in order to pick-up information expected from the signal with noise. Effort is concentrated on developing a novel arithmetic to improve extraction of the characteristic from stochastic signal and to enhance the voracity of detection. The main purpose discussed in this paper is to treat with signals on amplitudes with statistic mutuality and power density spectrum in frequency domain, and farther more to select samples for neural networks training by means of least-squares algorithm between real measuring signal and deterministic signals under laboratory condition. By seeking optimization with the algorithm, the parameters representing characteristic of the porcelain object are selected, while the stochastic interfere be weakened, then study for detection on neural networks is developed based on processing above.

  • PDF

Feasibility study of wide-band low-profile ultrasonic sensor with flexible piezoelectric paint

  • Li, Xin;Zhang, Yunfeng
    • Smart Structures and Systems
    • /
    • 제4권5호
    • /
    • pp.565-582
    • /
    • 2008
  • This paper presents a feasibility study of flexible piezoelectric paint for use in wide-band low-profile surface-mount or embeddable ultrasonic sensor for in situ structural health monitoring. Piezoelectric paint is a piezoelectric composite with 0-3 connectivity. Because of its ease of application, piezoelectric paint can be readily fabricated into sensing element with complex pattern. This study examines the characteristics of piezoelectric paint in acoustic emission signal and ultrasonic guided wave sensing. A series of ultrasonic tests including pitch catch and pencil break tests were performed to validate the ultrasonic wave sensing capability of piezoelectric paint. The results of finite element simulation of ultrasonic wave propagation, and acoustic emission generated by a pencil lead break on an aluminum plate are also presented in this paper along with corresponding experimental data. Based on the preliminary experimental results, the piezoelectric paint appears to offer a promising sensing material for use in real-time monitoring of crack initiation and propagation in both metallic and composite structures.

권선장력을 고려한 초전도 계자코일의 퀀치특성 및 AE 신호특성에 관한 연구 (A study on Quench Characteristics considering Winding Tension in Superconducting Coil using Acoustic Emission Technique)

  • 이준현;이민래;손명환;권영길
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제1권2호
    • /
    • pp.8-14
    • /
    • 1999
  • In this study, acoustic emission(AE) technique has been applied to detecting quench which is one of the serious peoblems to assure the integrity of superconducting coil at cryogenic temperature. The characteristics of AE parameters have been analyzed by correlating with the number of quenches, whinding tension of superconducting coil and charge rate of transport current. The quench localization was also performed using AE signals and there was also good correlation between quench current and AE parameters such as AE energy and AE events. In this study, it was confirmed that AE signals were mainly due to the conductor motion which caused by premature quenching. It was also found that optimized winding tension at superconducting coil was needed to prevent quench caused by conductor motion.

  • PDF

후두미세수술 전후 /아/의 음향적 특성 비교 (Comparative Study on the Acoustic Characteristics of the Korean Vowel /a/ before and after LMS)

  • 황연시;성철재
    • 대한음성학회지:말소리
    • /
    • 제67호
    • /
    • pp.33-60
    • /
    • 2008
  • The aim of this study is to show the differences in acoustic parameters between a pathological voice /a/ caused by vocal polyp and a normal voice /a/ produced after LMS (Laryngeal Microscopic Surgery). It was expected that voices of two kinds could be analyzed effectively in terms of HNR in specific frequency bands than in all frequency bands. For this study, 10 patients' voice were recorded before and after LMS and then were manipulated in terms of four acoustic parameter. It was found out that (a) frequency bands of 500Hz in the range of 1,000Hz to 4,000Hz were very useful to obtain HNR values; (b) frequency bands in the range of 1,248Hz to 5,500Hz on a log scale were very useful to obtain HNR values; (c) F0 dropped after LMS but not significantly; (d) the bandwidth of the second formant (B2) decreased significantly after LMS, while that of the first formant (B1) decreased after LMS but not significantly.

  • PDF

An Acoustic Study of the Perceptual Significance of F2 Transition of /w/ in English and Korean

  • Kang, Hyun-Sook
    • 음성과학
    • /
    • 제13권4호
    • /
    • pp.7-21
    • /
    • 2006
  • The intent of the present study is to investigate the acoustic properties of Korean /w/ in various phonological contexts, compare them with those of English /w/, and attempt to explain why English /w/'s are perceived differently by Korean speakers depending on the phonological contexts. Experiments 1 and 2 present the acoustic measure of F2 of Korean /w/ in various linguistic positions and show that unlike English /w/, Korean /w/ shows quite a strong coarticulation with the following vowel. Based on these experiments, Experiment 3 investigates why English /w/ is adapted differently into Korean. Specifically, it discusses why English /wain/ is adapted as /wain/ whereas English /twin/ is adapted into Korean as $/t^{h_i}win/$ with an extra vowel. This study argues that the different perception of English /w/ by Korean and English speakers is due to the different F2 transitional pattern of /w/ in Korean and English in various phonological contexts. It also argues that the F2 transitional pattern is an important factor in the perception of /w/.

  • PDF

2차원 절삭시의 각종 파라메터와 음향 방출 신호와의 상호 관계에 관한 연구 (A Study on the Correlation of Orthogonal Cutting all sorts Parameter and Acoustic Emission Signal)

  • 김재열;심재기;박환규;오환교
    • 한국정밀공학회지
    • /
    • 제8권1호
    • /
    • pp.74-83
    • /
    • 1991
  • A study on the Correlation of Orthogonal Cutting Parameter (Cutting speed, Depth of cut, Feed Rate) and Acoustic Emission Signal. It is well known that acoustic emission (AE) is the emission of elastic wave resulting from the deformation and fracture of materials. This study estabished correlation of orthogonal cutting parameter and AE signal, and researched into in-process monitoring of tool wear and failure. The results are as follow; 1. AE RMS was under the influence of cutting speed but hardly influenced by depth of cut and feed rate. 2. AE RMS was under the influence of flank wear. 3. AE count rate increased by increased cutting speed. 4. AE RMS value was rapidly increased in 130 m flank wear.

  • PDF

저소음 저배압을 위한 다중모드 지능제어 배기계에 관한 연구 -음향관 모델의 모델차수 결정방법- (The study on the multi-mode muffler by intelligent control for low noise and low backpressure)

  • 손동구;김흥섭;오재응
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 1996년도 추계학술대회논문집; 한국과학기술회관, 8 Nov. 1996
    • /
    • pp.142-147
    • /
    • 1996
  • For prediction and control of sound, acoustic systems must be modeled. Because sound systems like exhaust systems are very difficult to calculate mathematically, this study presents a method to determine experimentally the order of poles by transfer function. When designing a control system by traditional methods the exact model order and coefficient of the system to be controlled must be determined. But in acoustic systems, where systems to be controlled are very complex, mathematical interpretation is almost always impossible. Therefore transversal filters using trial and error methods to determine model order of a system are used to design a system. Compared to mathematical models with poles, transversal filters, in which the model order becomes relatively large, have the disadvantage of prolonged processing time and marked time delay. This study presents a method to determine experimentally the order of poles in a system model with poles and zeroes. Also, the validity of this method was verified mathematically and confirmed by application in general simple models and acoustic tube simulators.

  • PDF

입자 영상 유속계를 이용한 초음파 수직진동에 의해 유도된 공진상태에서의 음향유동에 관한 연구 (Study of Acoustic Streaming at Resonance by Longitudinal Ultrasonic Vibration Using Particle Imaging Velocimetry)

  • 노병국;이동렬
    • 한국음향학회지
    • /
    • 제23권5호
    • /
    • pp.340-352
    • /
    • 2004
  • 28.5 ㎑의 초음파의 미세 수직진동에 의해서 유도된 음향유동 (acoustic streaming)을 레이저를 이용한 입자 영상. 유속계에 의하여 고정 유리 평판과 초음파 진동자의 사이에서의 공기 유동을 가시화 하였다. 음향유동에 의한 공기의 유동 속도의 증가를 측정하기 위해 고정 유리 평판과 초음파 진동자의 사이에서의 속도변화를 실시간으로 측정하였다. 진동자와 고정 평판의 사이의 gap에 따른 음향유동의 세기의 변화를 정량적인 공기의 유동 속도의 변화에 의해 관찰되었고 고정판과 초음파 진동자 사이의 gap에서 공진 상태를 야기시키는 공진 Gap (H=18, 24, 30, 36㎜)중에서 공진 Gap (H)이 18m일 때 최대의 음향속도가 존재함을 알 수 있었고 진동자 표면부근에서부터 고정평판사이까지의 국소 최대 난류강도의 축 방향 위치에 따른 변화는 gap의 크기에 따라 8%∼70% 이었다. 전단응력값은 반경방향 위치의 중심영역에서 최대전단응력을 가지며 와도 분포도 반경방향 위치에서 진동자 중심영역에 최대 및 최소와도 값을 가짐을 알 수 있었다.

Influencing Factors Analysis of Facial Nerve Function after the Microsurgical Resection of Acoustic Neuroma

  • Hong, WenMing;Cheng, HongWei;Wang, XiaoJie;Feng, ChunGuo
    • Journal of Korean Neurosurgical Society
    • /
    • 제60권2호
    • /
    • pp.165-173
    • /
    • 2017
  • Objective : To explore and analyze the influencing factors of facial nerve function retainment after microsurgery resection of acoustic neurinoma. Methods : Retrospective analysis of our hospital 105 acoustic neuroma cases from October, 2006 to January 2012, in the group all patients were treated with suboccipital sigmoid sinus approach to acoustic neuroma microsurgery resection. We adopted researching individual patient data, outpatient review and telephone followed up and the House-Brackmann grading system to evaluate and analyze the facial nerve function. Results : Among 105 patients in this study group, complete surgical resection rate was 80.9% (85/105), subtotal resection rate was 14.3% (15/105), and partial resection rate 4.8% (5/105). The rate of facial nerve retainment on neuroanatomy was 95.3% (100/105) and the mortality rate was 2.1% (2/105). Facial nerve function when the patient is discharged from the hospital, also known as immediate facial nerve function which was graded in House-Brackmann : excellent facial nerve function (House-Brackmann I-II level) cases accounted for 75.2% (79/105), facial nerve function III-IV level cases accounted for 22.9% (24/105), and V-VI cases accounted for 1.9% (2/105). Patients were followed up for more than one year, with excellent facial nerve function retention rate (H-B I-II level) was 74.4% (58/78). Conclusion : Acoustic neuroma patients after surgery, the long-term (${\geq}1year$) facial nerve function excellent retaining rate was closely related with surgical proficiency, post-operative immediate facial nerve function, diameter of tumor and whether to use electrophysiological monitoring techniques; while there was no significant correlation with the patient's age, surgical approach, whether to stripping the internal auditory canal, whether there was cystic degeneration, tumor recurrence, whether to merge with obstructive hydrocephalus and the length of the duration of symptoms.

전자기 음향 공진을 이용한 강선의 표면 미세 결함 탐상 타당성 연구 (Feasibility Study on Surface Microcrack Detection of the Steel Wire Rods Using Electromagnetic Acoustic Resonance)

  • 허태훈;조승현;안봉영;임종수
    • 비파괴검사학회지
    • /
    • 제33권1호
    • /
    • pp.7-13
    • /
    • 2013
  • 철강 생산 제품 중 강선 (steel wire rod)은 제조 과정 중 종방향으로 미세한 표면 결함이 매우 빈번하게 발생하는데 이중 깊이가 수 십 마이크로미터 이상인 결함들은 최종 생산품의 불량을 유발하는 심각한 원인이 되고 있다. 이와 같은 이유로 강선의 제조 단계에서 표면의 미세 결함의 깊이를 평가하는 방법의 개발이 절실히 요구된다. 표면 미세 결함을 평가할 수 있는 여러 가지 방법 중에서, 본 연구에서는, 전자기 음향공진법의 적용 가능성을 고찰하고자 한다. 전자기 음향 공진 (electromagnetic acoustic resonance, EMAR)은 전자기 음향 트랜스듀서 (electromagnetic acoustic transducer, EMAT)을 이용하여 시편의 공진 특성을 측정하는 방법으로서, 대상의 작은 변화에도 민감하게 반응하고 비접촉 측정이 가능하여 현장 적용에 용이하다는 장점이 있다. 전자기 음향 공진 실험을 통하여 표면 미세결함과 잔향특성의 변화를 관찰하여 깊이 약 100 마이크로미터 내외의 결함은 탐상 가능함을 확인하였다.