• Title/Summary/Keyword: Acoustic study

Search Result 3,596, Processing Time 0.037 seconds

Laryngeal Findings and Phonetic Characteristics in Prelingually Deaf Patients (언어습득기 이전 청각장애인의 후두소견 및 음성학적 특성)

  • Kim, Seong-Tae;Yoon, Tae-Hyun;Kim, Sang-Yoon;Choi, Seung-Ho;Nam, Soon-Yuhl
    • Journal of the Korean Society of Laryngology, Phoniatrics and Logopedics
    • /
    • v.20 no.1
    • /
    • pp.57-62
    • /
    • 2009
  • Background and Objectives : There are few studies reported that specifically examine the laryngeal function in patients with profound hearing loss or deafness, This study was designed to examine videostroboscopic findings and phonetic characteristics in adult patients with prelingually deaf. Materials and Method: Sixteen patients (seven males, nine females) diagnosed as prelingually deaf aged from 19 to 54 years, and were compared with a 20 normal control group with no laryngeal pathology and normal hearing group, Videostroboscopic evaluations were rated by experienced judges on various parameters describing the structure and function of the laryngeal mechanism during comfortable pitch and loudness phonations. Acoustic analysis test were done, and a nasalance test performed to measure rabbit, baby, and mother passage. CSL were measured to determine the first and two formant frequencies of vowels /a/, /i/, /u/, Statistical analysis was done using Mann-Whitney U or Wilcoxon signed ranks test. Results: Videostroboscopic findings showed phase symmetry but significantly more occurrences decrement in the amplitude of vibration, mucosal wave, irregularity of the vibration and increased glottal gap size during the closed phase of phonation, In addition, group of prelingually deaf patients were observed to have significantly more occurrences of abnormal supraglottic activities during phonation. The percentage of shimmer in the group of prelingually deaf patients were higher than in the control group. Characteristics of vowels were lower of the second formant of the vowel /i/. Nasalance in prelingually deaf patients showed normal nasality for all passages, Conclusion: Prelingually deaf patients show stroboscopic abnormal findings without any mucosal lesion, suggesting that they have considerable functional voice disorder. We suggest that prelingually deaf adults should perform vocal training for normalized laryngeal function after cochlear implantation.

  • PDF

Differentiation of Adductor-Type Spasmodic Dysphonia from Muscle Tension Dysphonia Using Spectrogram (스펙트로그램을 이용한 내전형 연축성 발성 장애와 근긴장성 발성 장애의 감별)

  • Noh, Seung Ho;Kim, So Yean;Cho, Jae Kyung;Lee, Sang Hyuk;Jin, Sung Min
    • Journal of the Korean Society of Laryngology, Phoniatrics and Logopedics
    • /
    • v.28 no.2
    • /
    • pp.100-105
    • /
    • 2017
  • Background and Objectives : Adductor type spasmodic dysphonia (ADSD) is neurogenic disorder and focal laryngeal dystonia, while muscle tension dysphonia (MTD) is caused by functional voice disorder. Both ADSD and MTD may be associated with excessive supraglottic contraction and compensation, resulting in a strained voice quality with spastic voice breaks. The aim of this study was to determine the utility of spectrogram analysis in the differentiation of ADSD from MTD. Materials and Methods : From 2015 through 2017, 17 patients of ADSD and 20 of MTD, underwent acoustic recording and phonatory function studies, were enrolled. Jitter (frequency perturbation), Shimmer (amplitude perturbation) were obtained using MDVP (Multi-dimensional Voice Program) and GRBAS scale was used for perceptual evaluation. The two speech therapist evaluated a wide band (11,250 Hz) spectrogram by blind test using 4 scales (0-3 point) for four spectral findings, abrupt voice breaks, irregular wide spaced vertical striations, well defined formants and high frequency spectral noise. Results : Jitter, Shimmer and GRBAS were not found different between two groups with no significant correlation (p>0.05). Abrupt voice breaks and irregular wide spaced vertical striations of ADSD were significantly higher than those of MTD with strong correlation (p<0.01). High frequency spectral noise of MTD were higher than those of ADSD with strong correlation (p<0.01). Well defined formants were not found different between two groups. Conclusion : The wide band spectrograms provided visual perceptual information can differentiate ADSD from MTD. Spectrogram analysis is a useful diagnostic tool for differentiating ADSD from MTD where perceptual analysis and clinical evaluation alone are insufficient.

  • PDF

Cardiovascular response to surprise stimulus (놀람 자극에 대한 심혈관 반응)

  • Eom, Jin-Sup;Park, Hye-Jun;Noh, Ji-Hye;Sohn, Jin-Hun
    • Science of Emotion and Sensibility
    • /
    • v.14 no.1
    • /
    • pp.147-156
    • /
    • 2011
  • Basic emotions such as happiness, sadness, anger, fear, and disgust have been widely used to investigate emotion-specific autonomic nervous system activity in many studies. On the contrary, surprise emotion, Suggested also as one of the basic emotions suggested by Ekman et al. (1983), has been least investigated. The purpose of this study was to provide a description of cardiovascular responses on surprise stimulus using electrocardiograph (ECG) and photoplethysmograph (PPG). ECG and PPG were recorded from 76 undergraduate students, as they were exposed to a visuo-acoustic surprise stimulus. Heart rate (HR), standard deviation of R-R interval (SD-RR), root mean square of successive R-R interval difference (RMSSD-RR), respiratory sinus arrhythmia (RSA), finger blood volume pulse amplitude (FBVPA), and finger pulse transit time (FPTT) were calculated before and after the stimulus presentation. Results show significant increase in HR, SD-RR, and RMSSD-RR, decreased FBVPA, and shortened FPTT. Evidence suggests that surprise emotion can be characterized by vasoconstriction and accelerated heart rate, sympathetic activation, and increased heart rate variability, parasympathetic activation. These results can be useful in developing an emotion theory, or profiling surprise-specific physiological responses, as well as establishing the basis for emotion recognition system in human-computer interaction.

  • PDF

The Effect of Triamcinolone Injection on the Vocal cord during Laryngeal Microsurgery in the Patient of the Vocal Polyp (성대용종환자에서 후두미세수술시에 수술부위에 Triamcinolone 국소주입이 음성에 미치는 영향에 대한 연구)

  • Yoo, Jun;Oh, Kyung Ho;Yoon, Hee Chul;Lee, Doh Young;Woo, Jeung soo;Baek, Seung Kuk;Jung, Kwang Yoon;Kwon, Soon Young
    • Journal of the Korean Society of Laryngology, Phoniatrics and Logopedics
    • /
    • v.26 no.2
    • /
    • pp.122-126
    • /
    • 2015
  • Background and Objective : Laryngeal microscopic surgery (LMS) is popular method to treat for vocal polyp. There is not always the improvement of the voice after operation. Many methods have been developed for better outcome of the surgery. The purpose of this study is to investigate the effect of the triamcinolone injection at vocal cord during LMS. Materials and Methods : The medical records of 28 patients, received LMS under diagnosis of vocal polyp, were retrospectively reviewed. The patients were divided into two groups depending on whether triamcinolone injected or not (case group : Triamcinolone-injected group, control group : Triamcinolone-not injected group). The quality of voice was evaluated by GRBAS scale, fundamental frequency (Fo), jitter, shimmer and NHR (Noise to harmonic ratio) at previous operation, 4 weeks after operation, 8 weeks after operation. Each voice analysis factor was compared between case group and control group by Independent t-test. Results : The mean differences of each voice analysis factor. The mean difference of Jitter, Shimmer, NHR in case group were lower than in control group, and mean difference of GRBAS scale in case group were higher than in control group. These differences were not significant (p>0.05). Conclusion : Though there was a tendency of better voice outcome in patients of triamcinolone-injection, it may not be concluded that the triamcinolone injection is helpful for better voice outcome in surgery of vocal polyp due to statistical insignificance.

  • PDF

A Comparison of Acoustic Parameters between Vocal Fold Bowing and Vocal Fold Polyp (궁형성대와 성대폴립 간의 음성 비교)

  • Kang, Young-Ae;Yoon, Yeo-Hoon;Yoon, Kyu-Chul;Seong, Cheol-Jae
    • Journal of the Korean Society of Laryngology, Phoniatrics and Logopedics
    • /
    • v.22 no.1
    • /
    • pp.40-46
    • /
    • 2011
  • Background and Objectives : Vocal fold bowing is an organic voice disorder that is associated with an abnormal structure of the vocal folds whereas vocal fold polyp is a functional voice disorder caused by an abnormal use of the vocal folds. Both types of vocal folds share a common property in that they make one's voice breathy or strained. The purpose of this study is to compare voice from two types of vocal folds and to offer information of clinical importance. Materials and Method: Vocal fold bowing and vocal fold polyp groups consisted of 7 male subjects, respectively. All subjects recorded /a/ in the state of measuring MPT (maximum phonation time), repeating 3 times, by a voice recorder (48 kHz sampling rate; 24 bit quantization). They answered the questions of K-VHI. Time domain parameters (such as perturbation parameters including HNR, Jitter, etc.) were calculated for the whole duration of /a/ and those of the frequency domain were measured in initial 40 ms and stable 40 ms of /a/, respectively. Mann-Whitney V-test was used for the time domain parameters and K-VHI survey, and Wilcoxon signed rank test was applied to the frequency domain parameters (H1, H2, H1-H2). Results: For K-VHI survey and the time domain analysis, there was no significant difference between bowing and polyp group. For frequency domain analysis, H1 and H2 showed a significantly different result between two groups. Vocal fold bowing group has longer duration and lower intensity than that of vocal fold polyp group in the 'aspirated interval', which could be observable prior to ordinary vowel oscillation. Conclusion: Both groups seem to show breathy voice. This could be referred on the basis of the value of H1-H2. The K-VHI survey says that subjects with vocal fold bowing feel more uncomfortable than subjects with vocal fold polyp.

  • PDF

Computational Analysis on the Noise Characteristics of Ship Large Duct (선박용 대형 덕트의 소음 특성 전산해석 연구)

  • Song, Jee-Hun;Hong, Suk-Yoon;Lee, Yi-Soo;Kwon, Hyun-Wung
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.21 no.6
    • /
    • pp.751-758
    • /
    • 2015
  • Noise prediction for HVAC(Heating, Ventilating and Air Conditioning) systems are normally performed by empirical method suggested by NEBB(National Environmental Balancing Bureau, 1994). However, the method is not suitable for large ducts in ships. In this paper, computational analysis methods are used to develop a noise prediction method for the large ducts in ships. To develop regression formula of attenuation of sound pressure level in large ducts, Boundary Element Method(BEM) is used. BEM and Computational Fluid Dynamics(CFD) are applied to the analysis of flow-induced noise in ducts with stiffeners inside. Loud noise above 100 dB can be generated in some cases. Breakout noises of large ducts are also analyzed by using BEM and Finite Element Method(FEM). The acoustic pressure level shows about 10-15dB difference between inside and outside of the duct. Utilizing the results of this study, it is expected that shipyard planners can predict noise of the HVAC system for ships.

Measurement and Analysis for the Upper Side Flow Boundary Layer of a High Speed Train Using Wind Tunnel Experiments with a Scaled Model (축소모형 풍동시험을 이용한 고속열차의 유동 상부경계층 측정 및 분석)

  • Oh, Hyuck Keun;Kwon, Hyeok-bin;Kwak, Minho;Kim, Seogwon;Park, Choonsoo
    • Journal of the Korean Society for Railway
    • /
    • v.19 no.1
    • /
    • pp.11-19
    • /
    • 2016
  • The flows around a high speed train are very important because they could affect the aerodynamic characteristics such as drag and acoustic noise. Especially the boundary layer of flows could represent the characteristic of flows around the high speed train. Most previous studies have focused on the boundary layer region along the train length direction for the side of the train and underbody. The measurement and analysis of the boundary layer for the roof side is also very important because it could determine the flow inlet condition for the pantograph. In this study, the roof boundary layer was measured with a 1/20 scaled model of the next generation high speed train, and the results were compared with full-scaled computational fluid dynamics results to confirm their validity. As a result, it was confirmed that the flow inlet condition for the pantograph is about 85% of the train speed. Additionally, the characteristics of the boundary layer, which increases along the train direction, was also analyzed.

Sound Insulation Properties of Polymer Soundproof Panels (폴리머 계열 방음패널의 차음특성 비교 분석)

  • Lee, Woo-Mi;Lee, Ju Haeng;Son, Jin-Hee;Kim, Il-Ho;Park, Jae-Roh;Kim, Kwang Soo
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.35 no.8
    • /
    • pp.592-597
    • /
    • 2013
  • It is widely known that the sound insulation of soundproof panel is highly correlated to two factors, surface density of material and the frequency of noise. Accordingly, the character of traffic noise released in actual situation is important requisite for determining thickness to determine surface density and material of soundproof panel. This present study selected polymer panel with advantage of light weight and workability and evaluates according to frequency of traffic noise. Polypropylene (PP) and high-density polyethylene (HDPE) were selected as subjects based on economic valuation and efficiency. The sound transmission loss of selected polymer panels were compared with the currently used panels such as polycarbonate (PC) and polymethyl methacrylate (PMMA) depending on thickness and materials. As a result, PC showed the highest sound transmission loss followed by PMMA, HDPE, and PP in range of mass law. In terms of acoustic performance on thickness, the transmission loss increased with thickness of soundproof panel meanwhile coincidence dip was observed in lower frequency where had reduced transmission loss. Therefore, it is suggested that after determining target frequency, the kind of materials and thickness of soundproof panel need to be designed so that traffic noise can be more efficiently reduced.

Effect of Irradiation Temperature on Physicochemical and Sensory Properties of Tarakjuk (Milk Porridge) (방사선 조사 온도가 타락죽의 이화학적 및 관능적 품질 특성에 미치는 영향)

  • Han, In-Jun;Song, Beom-Seok;Lee, Ju-Woon;Kim, Jae-Hun;Choi, Kap-Sung;Park, Jeong-Ro;Chun, Soon-Sil
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.40 no.9
    • /
    • pp.1307-1313
    • /
    • 2011
  • This study was conducted to evaluate the effects of irradiation temperature on the physicochemical and sensory properties of Tarakjuk, milk porridge. Tarakjuk was gamma-irradiated at different temperatures of $25^{\circ}C$ (in room), $4^{\circ}C$ (in ice), and $-20^{\circ}C$ (in dry ice) at a dose of 10 kGy, and then autoclaved at $120^{\circ}C$ for 15 min for comparison. pH and Hunter's color value of Tarakjuk were not changed by irradiation regardless of the temperature. However, the TBA (2-thiobarbituric acid) value decreased as irradiation temperature was decreased. The viscosity of Tarakjuk irradiated in dry ice was significantly higher than that irradiated at room temperature and in ice (p<0.05). For the sensory evaluation, there were no significant differences in overall acceptability between non-treated Tarakjuk and that irradiated in dry ice. Flavor pattern analysis using an electronic nose with a SAW (surface acoustic wave) sensor determined that the main peaks at retention times 3.88 and 7.34 sec were related with off-flavor induced by irradiation and unique flavor of Tarakjuk, respectively. These results indicated that irradiation at freezing temperature improved quality deterioration of Tarakjuk by gamma irradiation. However, sensory quality of Tarakjuk irradiated at freezing temperature was still lower than that of non-irradiated Tarakjuk. Therefore, further research is needed to improve the quality of Tarakjuk using combined treatment such as addition of antioxidants and vacuum packaging method.

Feasibility Calculation of FaSTMECH for 2D Velocity Distribution Simulation in Meandering Channel (사행하천의 2차원 유속분포 모의를 위한 FaSTMECH 모형의 적용성 검토)

  • Son, Geunsoo;You, Hojun;Kim, Dongsu
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.34 no.6
    • /
    • pp.1753-1764
    • /
    • 2014
  • Numerical flow simulation models in the riverine environments have been widely utilized for analyzing flow dynamics in various degrees in researches and practical applications. However, most of the simulated results have been validated based on the data from indoor experimental models or very limited in-situ measurements. Therefore, it has been required to more accurately validate the performance of the numerical models in terms of the detailed field observations. In particular, it was also hard to validate the performances of the existing numerical models in the real meandered river channels that encompass more sophisticated flow and geometric structures. Recently, advancements of the modern flow measuring instrumentations such as acoustic Doppler current profilers (ADCPs) enabled us to efficiently acquire the detailed flow field in the broad range of river channels, thus that it became to be possible to accurately validate any numerical models with the field observations. In this study, based on the detailed flow measurements in a actual meandered river channel using ADCP, we validated FaSTMECH model in iRIC in terms of water surface elevation, which is relatively new but began to get highlighted in the research areas. As the validation site, a meandering channel in River Experiment Center of KICT was chosen, which has 6.5 m of width, 0.38m of flow depth, 1.54 m3/s of flow discharge, 0.61 m/s of mean flow velocity, and 1.2 of sinuosity. As results, whereas the FaSTMECH precisely simulated water surface elevation, simulated velocity field in the bend did not match well with ADCP dataset.