• Title/Summary/Keyword: Acoustic parameters

Search Result 849, Processing Time 0.026 seconds

A Study on the Effects of Parameter Sensitivity on Matched Field Processing

  • Park, Cheolsoo;Woojae Seong;Park, Hang-Soon;Lee, Kyu-Yeul
    • The Journal of the Acoustical Society of Korea
    • /
    • v.20 no.1E
    • /
    • pp.31-37
    • /
    • 2001
  • Matched Field Processing (MFP) is a successive process of correcting mismatches between true and assumed parameters by matching the measured acoustic field data with numerically simulated data which we call replica. The MFP is widely used both in geo-acoustic parameter inversions and in source localizations. Whether a certain parameter can be inverted effectively or whether a source can be localized correctly depends on the amount of the influence that a parameter has on the acoustic field during the matching process. Sensitive parameters can be better estimated than the less sensitive ones in MFP. On the contrary, the sensitive parameters affect adversely on the source localization results when they have uncertainties. In this paper, a sensitivity index is defined based upon the field variation resulting from the perturbed parameters. Numerical test results show that the index behaves in accordance with the results of source localization under a mismatched environment and also with the inversion solutions.

  • PDF

Acoustic Characteristics of the Voices of Korean Normal Adults by Gender on MDVP (성별에 따른 한국 정상 성인 음성의 음향학적 평가 기준치)

  • Kim, Jae-Ock
    • Phonetics and Speech Sciences
    • /
    • v.1 no.4
    • /
    • pp.147-157
    • /
    • 2009
  • The purpose of the study is to develop the normal voice database and to analyze the acoustic characteristics of Korean adults' voices by gender using MDVP. Eight categories in the 34 parameters of MDVP were analyzed in the voices of 170 Korean normal adults taken from /a/ vowel. Among them, Fundamental Frequency Parameters and Frequency Perturbation Parameters were significantly different by gender. In addition, Fundamental Frequency Parameters of our data were remarkably different from the data suggested in the MDVP program which currently used in clinics. Therefore, the data obtained from the current study can be effectively used for the diagnosis of voice disorders of Korean adults as the standard parameter values of MDVP.

  • PDF

A Study on the Diagnosis of Laryngeal Diseases by Acoustic Signal Analysis (음향신호의 분석에 의한 후두질환의 진단에 관한 연구)

  • Jo, Cheol-Woo;Yang, Byong-Gon;Wang, Soo-Geon
    • Speech Sciences
    • /
    • v.5 no.1
    • /
    • pp.151-165
    • /
    • 1999
  • This paper describes a series of researches to diagnose vocal diseases using the statistical method and the acoustic signal analysis method. Speech materials are collected at the hospital. Using the pathological database, the basic parameters for the diagnosis are obtained. Based on the statistical characteristics of the parameters, valid parameters are chosen and those are used to diagnose the pathological speech signal. Cepstrum is used to extract parameters which represents characteristics of pathological speech. 3 layered neural network is used to train and classify pathological speech into normal, benign and malignant case.

  • PDF

Study on Acoustic Characteristics of the Watermelon (수박의 음향특성에 관한 연구)

  • 김만수;최동수;이영희;조영길
    • Journal of Biosystems Engineering
    • /
    • v.23 no.1
    • /
    • pp.57-66
    • /
    • 1998
  • This study was conducted to investigate the relationships between parameters affecting internal quality of watermelon and its acoustic characteristics. The measuring and analyzing system was established to study the acoustic characteristics of watermelon. Algorithms for analyzing sound signals were developed. Sound signals which was detected with the microphone were filtered, and their spectrum was computed by means of the Fast Fourier Transform. As watermelon changed from the unripe stage to ripe, acoustic waves in time domain became complicated, and several components appeared in frequency domain. The correlationship was investigated between some parameters affecting internal quality of the watermelon and several peak frequencies. Results indicated that weight, density and sugar content had high correlations with several frequencies(the first peak frequency, the second peak frequency, and the third peak frequency). And the sugar content and the volume of the watermelon were highly correlated with the third peak frequency.

  • PDF

A Performance Improvement of Ultrasonic Diagnosis Transducer by Transient Acoustic Field Analysis (과도음장 해석을 통한 초음파 진단 탐촉자의 성능 개선)

  • 박은주;송행용;김무준;김동현;이수성;하강열
    • The Journal of the Acoustical Society of Korea
    • /
    • v.21 no.8
    • /
    • pp.744-756
    • /
    • 2002
  • The transient acoustic fields formed by a 3.5 ㎒ curved linear array transducer which is commonly used in ultrasonic medical imaging system for diagnosis of abdomen are systematically analyzed to obtain new design parameters for the better acoustic image. In the analysis with an assumption of radiating waveform, element size, radius of curvature, amplitude apodization are considered as parameters giving constitutive relations with the fields. As simulation results, appropriate new parameters with the reduced curvature and elevation aperture and the apodization of Hamming window, which make an improved acoustic beam with lower side lobe levels than a conventional typical transducer, are obtained.

Investigation of the Preferred Acoustic Characteristics in Concert Halls (콘서트 홀에서 선호되는 음향특성에 관한 연구)

  • Choi Young-Ji
    • The Journal of the Acoustical Society of Korea
    • /
    • v.24 no.2
    • /
    • pp.111-116
    • /
    • 2005
  • This study deals with a subjective assessment to investigate the preferred acoustic conditions and determine the important acoustical parameters in concert halls. A subjective test was carried out using dummy head recorded sounds made in actual halls in Australia (referred to as Hall A and Hall B) to evaluate the acoustic performance of two halls. The results of subjective tests were then correlated with measured acoustical parameters to investigate the significant determinants for the preference judgements. The listeners show a stronger Preference for seats in the Hall B than those in the Hall A. The low preferences for seats in the Hall A are in agreement with live performance ratings assessed by musicians. It is found that the sound level is the most significant acoustical parameter for evaluating the overall acoustic preference in the two halls.

Room Acoustic Measurement System Using Impulse Response (임펄스응답을 이용한 실내음향 측정 시스템)

    • The Journal of the Acoustical Society of Korea
    • /
    • v.18 no.5
    • /
    • pp.63-67
    • /
    • 1999
  • Recently, a method of measuring impulse response is widely used for a room acoustic evaluation instead of measuring reverberation time by white noise excitation. Comparing with the traditional reverberation time measurement, this method has many advantages such as good repeatability and the ability to extract various room acoustic parameters at one measurement. In this study, the author developed a measuring system that can extract mono-aural room acoustic parameters from an impulse response measured with MLS (Maximum Length Sequence) signal excitation. These room acoustic parameters include reverberation times(EDT, RT), speech intelligibilities(C50, C80, D, U50, U80, AI) and sound strength(G). This paper introduces the configuration of the developed measuring system, test results and discussions for the measurements at several rooms.

  • PDF

An Aerodynamic and Acoustic Analysis of the Breathy Voice of Thyroidectomy Patients (갑상선 수술 후 성대마비 환자의 기식 음성에 대한 공기역학적 및 음향적 분석)

  • Kang, Young-Ae;Yoon, Kyu-Chul;Kim, Jae-Ock
    • Phonetics and Speech Sciences
    • /
    • v.4 no.2
    • /
    • pp.95-104
    • /
    • 2012
  • Thyroidectomy patients may have vocal paralysis or paresis, resulting in a breathy voice. The aim of this study was to investigate the aerodynamic and acoustic characteristics of a breathy voice in thyroidectomy patients. Thirty-five subjects who have vocal paralysis after thyroidectomy participated in this study. According to perceptual judgements by three speech pathologists and one phonetic scholar, subjects were divided into two groups: breathy voice group (n = 21) and non-breathy voice group (n = 14). Aerodynamic analysis was conducted by three tasks (Voicing Efficiency, Maximum Sustained Phonation, Vital Capacity) and acoustic analysis was measured during Maximum Sustained Phonation task. The breathy voice group had significantly higher subglottal pressure and more pathological voice characteristics than the non breathy voice group. Showing 94.1% classification accuracy in result logistic regression of aerodynamic analysis, the predictor parameters for breathiness were maximum sound pressure level, sound pressure level range, phonation time of Maximum Sustained Phonation task and Pitch range, peak air pressure, and mean peak air pressure of Voicing Efficiency task. Classification accuracy of acoustic logistic regression was 88.6%, and five frequency perturbation parameters were shown as predictors. Vocal paralysis creates air turbulence at the glottis. It fluctuates frequency-related parameters and increases aspiration in high frequency areas. These changes determine perceptual breathiness.

Acoustic Analysis of Voice Change According to Extent of Thyroidectomy (갑상선 수술범위에 따른 음성의 음향적 분석)

  • Kang, Young Ae;Koo, Bon Seok
    • Phonetics and Speech Sciences
    • /
    • v.7 no.4
    • /
    • pp.77-83
    • /
    • 2015
  • Voice complication without the laryngeal nerve injury can occur after thyroidectomy. The purpose of this study is to investigate voice changes according to extent of thyroidectomy with acoustic analysis. Thirty-five female patients with papillary thyroid carcinoma took voice evaluation at before and 1 month, and 3 months after thyroidectomy. Acoustic analysis parameters were speaking fundamental frequency(SFF), min $F_0$, max $F_0$, dynamic range $F_0$, jitter, shimmer, noise-to-harmonic ratio(NHR), and Cepstral prominence peak(CPP). Repeated-measured analysis of variance was applied. Time-related voice changes showed significant differences in all parameters except NHR. At 1 month after surgery, voice quality was worse and pitch was decreasing, but voice quality and pitch were improving at 3-month follow-up. Voice changes according to the extent of surgery were in SFF, max $F_0$, and dynamic range $F_0$. Time by surgery-related voice change existed only in min $F_0$. The result showed that the severity of voice complication depended on the extend of thyroidectomy which had a negative impact on $F_0$-related parameters. The deterioration of voice quality at 1 month after thyroidectomy may be affected by the loss of thyroid hormone in the blood. The descent of $F_0$-related parameters may be impacted by laryngeal fixation of surgical site adhesion.

Enhanced Approach Using Computational and Experimental Method for the Analysis of Loudspeaker System

  • Park Seok-Tae
    • The Journal of the Acoustical Society of Korea
    • /
    • v.24 no.3E
    • /
    • pp.90-98
    • /
    • 2005
  • Enhanced approach using computational and experimental method is proposed and performed to describe very well the behavior of loudspeaker than conventional method. Proposed procedure is composed of four parts. First, Thiele-Small parameters for test loudspeaker are identified by an electrical impedance method like as a delta mass method. Second part includes the processes to measure physical properties. Physical data like masses and thicknesses of loudspeaker's components are measured by an electrical precision scale and a digital vernier caliper. Third, the identified Thiele-Small parameters are proposed to be used as load boundary conditions for vibration analysis instead of electromagnetic circuit analysis to get a driving force upon bobbin part. Also, these parameters and physical data are used to modify physical properties required for computation to accommodate simulated sound pressure level with measured one for loudspeaker enclosure system. These data like as Young's modulus and thickness for a diaphragm are required for vibration analysis of loudspeaker but not measured accurately. Finally, it was investigated that simulated sound pressure level with full acoustic modeling including an acoustic port for test loudspeaker agreed with experimental result very well in the midrange frequency band(from 100 Hz to 2,000 Hz). In addition, several design parametric study is performed to grasp acoustical behaviors of loudspeaker system due to variations of diaphragm thicknesses and shapes of dust cap.