• Title/Summary/Keyword: Acoustic intensity

Search Result 373, Processing Time 0.024 seconds

A Study on the Noise Source Identification of Refrigerator Compressor (냉장고용 압축기 소음원 규명에 관한 연구)

  • O, Jae-Eung;Lee, Chang-Ho;Lee, Myeong-Ryeol;Yeom, Seong-Ha
    • The Journal of the Acoustical Society of Korea
    • /
    • v.6 no.1
    • /
    • pp.48-57
    • /
    • 1987
  • It is well known that the major noise source of Refrigerator is compressor, and due to the tendency of higher quality and more lighting of manufactured goods, the importance of prevention and reduction of a noise is increasing. In this paper, in order to prevent and reduce such a noise, sound pressure level and acoustic intensity are measured for compressor, and the result of these measurements, the noise radiation characteristics of compressor are reconized. And the experimental modal analysis is applied to the compressor to identify the noise sourcce. As the results of this study, we come to know that the spring, which is used to reduce vibration, does not reduce vibration efficiently, and compressor shell and its mounting system effect the noise radiation.

  • PDF

The Effects of Voice and Speech Intelligibility Improvements in Parkinson Disease by Training Loudness and Pitch: A Case Study (강도 및 음도 조절을 이용한 훈련이 파킨슨병 환자의 음성 및 발화명료도 개선에 미치는 효과: 사례연구)

  • Lee, Ok-Bun;Jeong, Ok-Ran;Ko, Do-Heung
    • Speech Sciences
    • /
    • v.8 no.3
    • /
    • pp.173-184
    • /
    • 2001
  • The purpose of this study was to examine the effects of manipulating loudness and pitch in terms of speech intelligibility and voice of a patient with Parkinson's Disease. The subject, who was diagnosed as a patient with Parkinson's disease 11 years ago, demonstrated a severely breath voice with low intensity. The accuracy of articulation in consonants was intelligible only at the single word level, and the overall intelligibility in continuous speech was low. The results showed that the subject's articulation accuracy and speech intelligibility was significantly improved after having loudness and pitch training. Habitual Fo, Jitter, Shimmer, Fo tremor, Amp tremor were decreased after training. In addition, the value of HNR also increased after training. It was shown that the changes of these acoustic parameters were closely related to the decrease of breathiness in Parkinson's voice, and this decrease of breathiness affected speech intelligibility considerably. Based on the experimental results, it was claimed that the vocal training by manipulating the loudness and pitch could be highly effective in improving the voice quality and speech intelligibility in Parkinson's Disease.

  • PDF

An Acoustical Study of English Diphthongs Produced by American Males and Females (미국인 남성과 여성이 발음한 영어이중모음의 음향적 연구)

  • Yang, Byung-Gon
    • Phonetics and Speech Sciences
    • /
    • v.2 no.2
    • /
    • pp.43-50
    • /
    • 2010
  • English vowels can be divided into monophthongs and diphthongs depending on the number of vocal tract shapes. Diphthongs are usually produced with more than one shape. This study attempts to collect acoustical data of English diphthongs published by Hillenbrand et al.(1995) online and to examine acoustic features of the diphthongs for phoneticians and English teachers. Sixty three American males and females were chosen after excluding those subjects with different target vowels or ambiguous formant tracks. The author used Praat to obtain the acoustical data systematically at eleven equidistant timepoints over the diphthongal segment. Obvious errors were corrected based on the spectrographic display of each diphthong. Results show that the formant trajectories of the diphthongs produced by the American males and females appeared quite similar. When the female formant values were uniformly normalized to those of the males, almost a perfect collapse occurred. Secondly, the diphthongal movements on the vowel space appeared not linear due to the coarticulatory gesture for the following consonant. Thirdly, the average duration of the diphthongs produced by the females was 1.156 times longer than that of the males while the pitch ratio between the two groups turned out to be 1.746 with a similar contour over measurement points. The author concludes that English diphthongs produced by various groups can be compared systematically when the acoustical values are obtained at proportional timepoints. Further studies will be desirable on the comparison of English diphthongs produced by native and nonnative speakers.

  • PDF

Mechanical Behaviors of CFRP Laminate Composites Reinforced with Aluminum Oxide Powder

  • Kwon, Oh-Heon;Yun, Yu-Seong;Ryu, Yeong-Rok
    • Journal of Power System Engineering
    • /
    • v.18 no.6
    • /
    • pp.166-173
    • /
    • 2014
  • In this study, a laminated composite material with dispersing aluminum oxide powder between the CFRP laminate plies, and also CFRP composites without aluminium oxide powder were fabricated for Mode I experiments using the DCB specimen and a tensile test. The behavior of the crack and the change of the interfacial fracture toughness were evaluated. Also in order to evaluate the damage mechanism for the crack extension, the AE sensor on the surface of the DCB test specimen was attached. AE amplitude was estimated for CFRP-alumina and CFRP composite. And the fracture toughness was evaluated by the stress intensity factor and energy release rate. The results showed that an unstable crack was propagated rapidly in CFRP composite specimen along with the interface, but crack propagation in CFRP-alumina specimen was relatively stable. From results, we show that aluminium oxide powder spreaded uniformly in the interface of the CFRP laminate carried out the role for preventing the sudden crack growth.

Correlation analysis of suspended sediment concentration and acoustic backscatter intensity (음파 후방산란강도와 부유사 농도의 상관관계 분석)

  • Park, JJi-Youn;Ryu, Hong Ryul;Kim, Dong-Ho;Hwang, Kyu-Nam
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2019.05a
    • /
    • pp.282-287
    • /
    • 2019
  • 본 연구의 목적은 음파를 이용하는 유속계로부터 관측된 후방산란강도와 실측된 부유사농도의 상관관계를 해석하여, 두 인자 사이의 관련 매개변수를 정량적으로 산정하고 관계식을 도출하는데 있다. 이를 위해 층별 유속계인 Aquadopp Profiler를 사용하여 사질 퇴적물 및 고령토 부유퇴적물 관측센서 검보정 챔버 실험을 수행하였다. 두 인자의 상관관계는 선형회귀분석을 통해 해석하였으며 그 결과로 도출된 접합곡선의 기울기는 각각 안목 A1 이 2.065, 안목 A2가 1.576, 고령토시료일 때 2.588의 값을 갖는데 이러한 차이는 시료 특성으로 설명될 수 있다. 서로 다른 입경을 갖는 시료는 후방산란 민감도에 차이가 있으며 이러한 영향으로 두 시료에서 산정된 계수 값에 차이가 발생한다. 본 연구를 통하여 도출된 측정 결과들은 후방산란강도에 미치는 수층 부유입자들의 영향이 매우 큼을 잘 보여준다. 일반적으로 수층 부유입자는 저면 퇴적물이 부유된 것으로 간주될 수 있으며, 또한 저면 퇴적물은 각 해역별로 site-specific 하다고 할 수 있다.

  • PDF

The Effect of Distance between Two Transducers on Sonochemical Reactions in Dual Irradiation Systems (이중 초음파 조사 시스템에서 진동부 사이의 거리가 초음파 화학 반응에 미치는 영향)

  • Kim, Eunkyung;Son, Younggyu
    • Journal of Soil and Groundwater Environment
    • /
    • v.18 no.5
    • /
    • pp.39-45
    • /
    • 2013
  • Many researchers have studied the effectiveness of ultrasound in chemical and environmental engineering fields including material synthesis, pollutant removal, cleaning, extraction, and disinfection. Acoustic cavitation induced by ultrasound irradiation in aqueous phase can cause various sonophysical and sonochemical reactions without any chemicals. However most of the previous studies focused only on the relationships between ultrasonic conditions and the results of sonochemical reactions in lab-scale sonoreactors. As a results of this, only a few studies have been devoted to design and optimization of industrial scale sonoreactors. In this study, the effect of the distance between two opposite transducer modules on sonochemical reactions was investigated in single and dual irradiation systems (334 kHz) for four distances including 50, 100, 150, and 200 mm using KI dosimetry. It was found that the dual irradiation systems provided higher performance in terms of the zeroth reaction coefficient and the cavitation yield compared to the single irradiation systems. The sonochemiluminescence (SCL) images for the visualization of the cavitation field showed that cavitation active zone was larger and sonochemical reaction intensity was much higher in the dual irradiation system than in the single irradiation system.

Study on Seabed Mapping using Two Sonar Devices for AUV Application (복수의 수중 소나를 활용한 수중 로봇의 3차원 지형 맵핑에 관한 연구)

  • Joe, Hangil;Yu, Son-Cheol
    • The Journal of Korea Robotics Society
    • /
    • v.16 no.2
    • /
    • pp.94-102
    • /
    • 2021
  • This study addresses a method for 3D reconstruction using acoustic data with heterogeneous sonar devices: Forward-Looking Multibeam Sonar (FLMS) and Profiling Sonar (PS). The challenges in sonar image processing are perceptual ambiguity, the loss of elevation information, and low signal to noise ratio, which are caused by the ranging and intensity-based image generation mechanism of sonars. The conventional approaches utilize additional constraints such as Lambertian reflection and redundant data at various positions, but they are vulnerable to environmental conditions. Our approach is to use two sonars that have a complementary data type. Typically, the sonars provide reliable information in the horizontal but, the loss of elevation information degrades the quality of data in the vertical. To overcome the characteristic of sonar devices, we adopt the crossed installation in such a way that the PS is laid down on its side and mounted on the top of FLMS. From the installation, FLMS scans horizontal information and PS obtains a vertical profile of the front area of AUV. For the fusion of the two sonar data, we propose the probabilistic approach. A likelihood map using geometric constraints between two sonar devices is built and a monte-carlo experiment using a derived model is conducted to extract 3D points. To verify the proposed method, we conducted a simulation and field test. As a result, a consistent seabed map was obtained. This method can be utilized for 3D seabed mapping with an AUV.

Modeling of ambient noise in ocean environment using coupled mode (연성모드법을 이용한 해양 배경소음 모델링)

  • Park, Jungyong;Kwon, Hyuckjong
    • The Journal of the Acoustical Society of Korea
    • /
    • v.41 no.4
    • /
    • pp.397-409
    • /
    • 2022
  • A model is developed for the calculation of sea surface generated ambient noise in the range dependent ocean environment. The sources are located in the horizontal plane all around and their depths are at the near-surface. The receiver array is located in the range dependent ocean waveguide. One-way coupled mode method is used to model the acoustic propagation between the sources and receiver in the range dependent waveguide, and the cross spectral density matrix of noise is derived. In simulation, noise intensity, beamforming result and coherence function are calculated from the cross spectral density matrix. These results are compared with those in the range independent environment. The modeling result shows the effect of the vertical directionality and asymmetry characteristics of the horizontal plane.

Discerning the intensity of precipitation through acoustic and vibrational analysis of rainfall via XGBoost algorithm (XGBoost 알고리즘을 활용한 강우의 음향 및 진동 분석 기반의 강우강도 산정)

  • Seunghyun Hwang;Jinwook Lee;Hyeon-Joon Kim;Jongyun Byun;Changhyun Jun
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2023.05a
    • /
    • pp.209-209
    • /
    • 2023
  • 본 연구에서는 강우 시 발생하는 음향 및 진동 신호를 기반으로 강우강도를 산정하기 위한 방법론을 제안하였다. 먼저, Raspberry Pi, 콘덴서 마이크 및 가속도 센서로 구성된 관측 기기로부터 실제 비가 내리는 환경에서의 음향 및 진동 신호를 수집하였다. 가속도 센서로부터 계측된 진동 신호를 활용하여 강우 유무에 대한 이진 분류를 수행하고, 강우가 발생한 것으로 판단된 기간에 해당하는 음향 신호에 Short-Time Fourier Transform 기술을 적용하여 주파수 영역에서 나타나는 magnitude의 평균과 표준 편차, 최고 주파수 등의 특징을 기반으로 강우강도를 산정하였다. 이를 위해 앙상블 기반의 머신러닝 학습 모델인 XGBoost 알고리즘을 사용하였으며, 광학 우적계를 통해 관측한 강우강도와 산정 결과를 비교·평가하였다. 강우강도 산정 과정에서 사용된 음향 신호의 길이를 1초, 10초, 1분으로 구분하였으며, 무강우 기간 내 음향 정보로부터 배경 음향에 의한 노이즈를 제거하고자 하였다. 최종적으로 강우 유무 이진 분류 과정의 선행 여부, 음향 신호의 길이 및 노이즈 제거 방법에 따른 강우강도 산정 결과들에 대한 성능 비교를 통해 본 연구에서 제안하고자 하는 방법론의 실효성을 평가하였다.

  • PDF

Comparison of voice range profiles of modal and falsetto register in dysphonic and non-dysphonic adult women (음성장애 성인 여성과 정상음성 성인 여성 간 진성구와 가성구의 음성범위프로파일 비교)

  • Jaeock Kim;Seung Jin Lee
    • Phonetics and Speech Sciences
    • /
    • v.14 no.4
    • /
    • pp.67-75
    • /
    • 2022
  • This study compared voice range profiles (VRPs) of modal and falsetto register in 53 dysphonic and 53 non-dysphonic adult women with gliding vowel /a/'. The results shows that maximum fundamental frequency (F0MAX), maximum intensity (IMAX), F0 range (F0RANGE), and intensity range (IRANGE) are lower in the dysphonic group than in the non-dysphonic group. F0MAX and F0RANGE are significantly higher in falsetto register than modal register in both groups. IMAX and IRANGE are significantly higher in falsetto register in the non-dysphonic group, but those are not different between two registers in the dysphonic group. There was no statistically significant difference in minimum F0 (F0MIN) and minimum intensity (IMIN) between the two groups. Modal-falsetto register transition occurred at 378.86 Hz (F4#) in the dysphonic group and 557.79 Hz (C5#) in the non-dysphonic group, which was significantly lower in the dysphonic group. It can be seen that both modal and falsetto registers in dysphonic adult women are reduced compared to non-dysphoinc adult women, indicating that the vocal folds of dysphonic adult women are not easy to vibrate in high pitches. The results of this study would be the basic data for understanding the acoustic features of voice disorders.