• Title/Summary/Keyword: Acoustic intensity

Search Result 376, Processing Time 0.031 seconds

Aerodynamic Study in Korean Western Classical Singers (서양음악을 전공으로 하는 성악인에서의 공기역학적 검사)

  • 정성민
    • Journal of the Korean Society of Laryngology, Phoniatrics and Logopedics
    • /
    • v.9 no.2
    • /
    • pp.109-114
    • /
    • 1998
  • Background and Objectives : Aerodynamic investigation is valuable information about the efficiency of the larynx in translating air pressure to acoustic signal. The normal data of the Korean has been reported, but there is no basic data of professional western classical singers who have learned how to control the flow of expiratory air for singing. The purpose of this study was to investigate the normal aerodynamic data of korean professional western classical singers and compare this with that of the Korean Materials and Methods : 50 Korean western classical singers were studied. Expiratory lung pressure combined with measurements of the mean air flow rate, voice frequency and intensity were measured with the aerodynamic test using airway interruption method. These data were compared with normal data of untrained normal adults. Results and Conclusions : The voice frequency and the voice intensity were increased in the western classic singers, but the mean air flow rate and the expiratory air pressure of the classical singers were within the same range of the untrained normal adults. This result means that western classical singers can change the loudness and pitch with a little increased or decreasing the mean air flow and the expiratory air pressure.

  • PDF

Prosodic pattern of the children with high-functioning autism spectrum disorder according to sentence type (문장유형에 따른 고기능 자폐스펙트럼장애 아동의 운율 특성)

  • Shin, Hee Baek;Choi, Jieun;Lee, YoonKyoung
    • Phonetics and Speech Sciences
    • /
    • v.8 no.2
    • /
    • pp.65-71
    • /
    • 2016
  • The purpose of this study is to examine the prosodic pattern of the children with high functioning autism spectrum disorder(HFASD) according to sentence type. The participants were 18 children aged from 7 - 9 years; 9 children with HFASD and 9 typical development children(TD) of the same chronological age with HFASD children. Sentence reading tasks were conducted in this study. Seven interrogative sentences and 7 declarative sentences were presented to the participants and were asked to read the sentences three times. Mean values of F0, F0 range, intensity, speech rate and pitch contour were measured for each sentence. The results showed that for F0 range, significant main effect and interaction effect were observed in the subject group and sentence type. There were significant differences in intensity, mean F0, speech rate, pitch contour across sentence types. The results of this study indicated that HFASD showed no difference in intonation across sentence types. Speakers' intention may have a negative effect on pragmatic aspects. These results suggest that the assessment and intervention of prosody be important for HFASD.

A study on speech analysis of person with presbycusis (노인성 난청인의 음성특성에 관한 연구)

  • Lee, S.M.;Song, C.G.;Woo, H.C.;Lee, Y.M.;Kim, W.K.
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1997 no.11
    • /
    • pp.67-70
    • /
    • 1997
  • In this paper, we evaluated the character of speech of hearing impaired person (HIP) who acquire his hearing loss after the youth. It is usually observed that severe HIP decreased not only speech perception but also vocalization. so there is a need for sensitive and quantitative measures or the assesment of the speech of the HIP to serve both diagnostic and prognosic purposes, 7 HIP and 12 normal hearing person(NHP) were studied with pure tone test and speaking test using word/sentence table which consists of vowel(a:), mono and two syllables and a sentence. we analyzed formant frequency, pitch, sound intensity, speech duration of HIP and NHP speech. According to the results, in the HIP's speech we find that formant frequency was shifted, first-formant prominence was reduced, the dynamic range of sound intensity was decreased, speech duration was prolonged. In the next, we expect the correlation between hearing and speech character of HIP is cleared through analysis of more acoustic parameters and precise selection of HIP group.

  • PDF

The Distribution of Chironomids by flow Mechanisms - Numerical Computation - (흐름 메카니즘에 의한 깔따구의 분포(II) - 수치계산 -)

  • Lee, Sang-Ho;Lee, Jung-Min;Kim, Tae-Won;Park, Jong-Pyo
    • Journal of Korean Society on Water Environment
    • /
    • v.22 no.1
    • /
    • pp.159-165
    • /
    • 2006
  • Numerical simulation of turbulence flow in a circulating channel was performed. The RNG $k-\varepsilon$ model and Reynolds stress model of the FLUENT was used for evaluating the flow mechanisms. The simulation results were compared with the experimental data measured by a ADV (Acoustic Doppler Velocitmeter). The distribution of chironomids was analyzed by the computational results. They distributed at the region of lower velocities and lower turbulence intensity. In the case of a hemisphere structure being located on the straight section, chironomids lived in the upstream and downstream area of the hemisphere. The secondary currents also affected the distribution of chironomids. In conclusion, the computational fluid dynamic techniques can be inexpensively applied for analysing the relationship between flow characteristics and distribution of benthic macroinvertebrates.

An experimental study of the overall characteristics in an aero-valved pulsating combustor (空氣밸브型 脈動燃燒器의 特性에 관한 實驗的 硏究)

  • 오상헌;최병륜;임광열
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.11 no.2
    • /
    • pp.271-278
    • /
    • 1987
  • The experimental study was carried out to investigate the pressure fluctuation, operating frequency, noise emission and combustion characteristics in an aero-valved pulsating combustor. Measurements of the pressure fluctuation, mean temperature and ion current inside the combustion chamber indicate that combustion phenomena are characteristically similar to those in the diffusion flame. The measured frequency schedue indicates that the acoustic theory of the quarter wave tube can be approximated to give the operating frequency, but correction factor must be involved to estimate the correct operating frequency. The spectral behavior of the noise emission exhibits that frequency bands with high noise intensity are narrowly restricted to the neighborhood of the operating frequency signalling the low-frequency combustion characteristics of the pulsating combustor. Measurements of the operating characteristics as variation of the fuel nozzle diameter and injection angle with 4 fuel nozzles have been made, and it was found that the system produced the stable operating conditions up to the turn down ratio of 3 when the fuel nozzle diameter is 1.2mm, and the optimum fuel injection angle is thought to be in the neighborhood of 30.deg. radially.

Magnetic Resonance-Guided Focused Ultrasound in Neurosurgery: Taking Lessons from the Past to Inform the Future

  • Jung, Na Young;Chang, Jin Woo
    • Journal of Korean Medical Science
    • /
    • v.33 no.44
    • /
    • pp.279.1-279.16
    • /
    • 2018
  • Magnetic resonance-guided focused ultrasound (MRgFUS) is a new emerging neurosurgical procedure applied in a wide range of clinical fields. It can generate high-intensity energy at the focal zone in deep body areas without requiring incision of soft tissues. Although the effectiveness of the focused ultrasound technique had not been recognized because of the skull being a main barrier in the transmission of acoustic energy, the development of hemispheric distribution of ultrasound transducer phased arrays has solved this issue and enabled the performance of true transcranial procedures. Advanced imaging technologies such as magnetic resonance thermometry could enhance the safety of MRgFUS. The current clinical applications of MRgFUS in neurosurgery involve stereotactic ablative treatments for patients with essential tremor, Parkinson's disease, obsessive-compulsive disorder, major depressive disorder, or neuropathic pain. Other potential treatment candidates being examined in ongoing clinical trials include brain tumors, Alzheimer's disease, and epilepsy, based on MRgFUS abilities of thermal ablation and opening the blood-brain barrier. With the development of ultrasound technology to overcome the limitations, MRgFUS is gradually expanding the therapeutic field for intractable neurological disorders and serving as a trail for a promising future in noninvasive and safe neurosurgical care.

Efficacy of intensive treatment of dysarthria for people with multiple system atrophy (다계통위축증 환자를 대상으로 한 마비말장애 집중 치료의 효과)

  • Park, Youngmi
    • Phonetics and Speech Sciences
    • /
    • v.10 no.4
    • /
    • pp.163-171
    • /
    • 2018
  • A mixed dysarthria with combinations of hypokinetic, ataxic, and spastic components is a common clinical feature of multiple system atrophy (MSA). Due to the rapid progress of dysarthria after diagnosis, people with MSA experience difficulty with verbal communication, which eventually affects their quality of life negatively. In this study, SPEAK $OUT!^{(R)}$, an intensive 1:1 treatment of dysarthria for improving functional communicative ability, was provided to twelve people with MSA. To evaluate the efficacy of SPEAK $OUT!^{(R)}$ in people with MSA, aerodynamic, acoustic, and perceptual analyses were conducted. Pre-and post-therapy data included maximum phonation time, vocal intensity, and fundamental frequency during /a/ sustained phonation and passage reading; frequency range between high /a/ and low /a/ phonation; jitter, shimmer, and HNR for vocal quality; speech rate during passage reading; and perceptual evaluation scores for articulation precision and intonation. The participants achieved statistically significant improvement in vocal intensity, pitch range, vocal quality, speech rate, and speech intelligibility. In conclusion, SPEAK $OUT!^{(R)}$ is a feasible treatment for people with MSA to efficaciously improve their speech ability.

A Study on The Multi-point Signal and It's Directivity detection of FBG Hydrophone Using Hopper WDM be in The Making (Hopper WDM을 이용한 FBG(Fiber Bragg Grating) 하이드로폰(Hydrophone)의 다중점신호검출 및 지향성 연구)

  • Kim, Kyung Bok
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.52 no.11
    • /
    • pp.156-163
    • /
    • 2015
  • In the using of FBG(Fiber Bragg Grating) developed in home land, we designed and manufactured united FBG acoustic transducers the first in Korea. they are being applied to multi-point signal detection of FBG Hydrophone used Hopper WDM(national patent NO 10-1502954) in the underwater. On united FBG transducers manufactured, we made an demonstrated on respective frequency response peculiarities in the underwater and analyzed the special characters. As the experimental result on frequency response peculiarities, we made it possible underwater acoustic detection on united FBG acoustic transducers type to maximum 30Hz~2.5KHz. it's the optimum conditions of 1.2KHz frequency in detection. And for the purpose of realization on multi-point signal detection on wide scope in the underwater, in the using of WDM(Wavelength Division Multiplexing) method and passive band-pass filter system, established arrays system and succeeded in multi-point underwater acoustic signal detection to the frequency 200Hz~1.3KHz out of the two united type FBG transducers. Additionally, it would be possible directivity detection for the object of its source as the intensity of detection signal varies with the sound source's direction and angle. From now on we prepared a new moment on the practical use study on FBG hydrophone in the future.

The Effect of An Increase of Closed Quotient on Improvement of Voice Quality after Type I Thyroplasty in Patients with Unilateral Vocal Cord Paralysis (일측 성대마비 환자에서 성대내전술 후 성대접촉율의 증가가 음질 개선에 미치는 영향)

  • Kim, Han-Su;Choi, Seung-Hee;Lim, Jae-Yol;Choi, Hong-Shik
    • Journal of the Korean Society of Laryngology, Phoniatrics and Logopedics
    • /
    • v.15 no.1
    • /
    • pp.16-20
    • /
    • 2004
  • Purpose : To assess perceptual, acoustic and aerodynamic measure of voice quality in patients with unilateral vocal cord paralysis before and after type I thyroplasty. Methods : The clinical records of patients operated type I thyroplasty in the Departement of otorhinoalryngolgy, Yongdong Severance hospital from November 2001 to November 2003 were reviewed. All patients uderwent a vocal function evaluation including perceptual, acoustic and aerodynamic measures of voice preoperative and on $60^{th}$ postoperative day. The perceptual and acoustic measures were obtained from recording of patients' reading a 'Sanchak' passage. The perceptual evaluation was performed by 2 speech pathologist using a 4-point rating scale. Acoustic parameters(voice range profile low(RAL), voice range profile high(RAH), average fundamental frequency(AFX), closed quotient, harmonic to noise ratio, jitter and shimmer) were investigated by Lx speech studio. Mean flow rate(MFR), subglottic pressure(Psub) and intensity were measured using the Phonatory function analyzer. The maximum phonation time was also measured. The data were statistically analyzed. A paired t-test (p<0.1) was used to compare preoperative and postoperative results. And multiple regression test was used to find which parameter was most correlated to improvement of postoperative voice quality. Results : Among aerodynamic parameters, Psub $(88.11mmH_2O{\rightarrow}58.7mmH_2O)$, MPT(7.87sec${\rightarrow}$12.53sec), MFR (359.8ml/sec${\rightarrow}$161.06ml/sec) were statistically improved. AFx(205.5Hz${\rightarrow}$163.27Hz), AQx(23.9%${\rightarrow}$48.3%), RAL, RAH. Jotter and shimmer were improved. In multiple regression test, AFx and AQx was noted as the two meost correlated parameters to improvement of postoperative breathiness. But general grade of voice quality was more correlated to Psub and shimmer. Conclusion : Vocal fold medialization procedures effectively reduce glottic gap. Increasing of contact area of both vocal folds induced improvement in aerodynamic parameters and leaded stabilizing of vocal fold vibration. That effect results in improvement in acoustic parameters (shimmer, jitter, signal-to-noise ratio, voice range profile) and voice quality.

  • PDF

Optimum Monitoring Parameters for the Safety of Mechanical Seals (미캐니컬 씰의 안전운용 감시를 위한 최적 계측인자)

  • Soon-Jae Lim;Man-Yong Choi
    • Journal of the Korean Society of Safety
    • /
    • v.12 no.4
    • /
    • pp.214-219
    • /
    • 1997
  • The mechanical seals, which are installed in rotating machines like pump and compressor, are generally used as sealing devices in the many fields of industries. The failure of mechanical seals such as leakage, crack, breakage, fast and severe wear, excessive torque, and squeaking results in big problems. To identify abnormal phenomena on mechanical seals and to propose the proper monitoring parameter for the failure of mechanical seals, sliding wear experiments were conducted. Acoustic emission, torque, and temperature were measured during experiments. Optical microstructure was observed for the wear processing after every 10 minute sliding at rotation speed of 1750 rpm and scanning electron microscopy was also observed. Except for the initial part of every experiment, the variation of acoustic emission was well coincided with torque variation during the experiments. This study concludes that acoustic emission and torque are proper monitoring parameters for the failure of mechanical seals. The intensity of acoustic emission signals is measured in root mean square voltage. Temperature of sealing face will be used as a parallel parameter for increasing the reliability of monitoring system.

  • PDF